# New Naming conventions | ||
|
||
1) Country codes: 3 characters | ||
|
||
2) Fuel codes: 6 characters (Except from the intermediate fuels for NG pipeline) | ||
|
||
^^^___: first three characters 01-03 represent country code | ||
|
||
___^^^: last three characters 04-06 | ||
- list of fuels: ETH, CO1, CO2, BIO, COA, LFO, GAS, HFO, SOL, WIN, URN, CHA, WA1, WA2, EL1, HE2, EL2, FW3, HE3, EL3, HF3, LF3, CH3, GA3, CO3, BO3, CR3, DEL, DLG, DNG | ||
- the fuels that have number 3 at the end represent the final energy demand = FW3, HE3, EL3, HF3, LF3, CH3, GA3, CO3, BO3, CR3 | ||
- the fuels that have the description GASP at the end represent the intermediate fuels for NG pipeline | ||
|
||
** Note: CO1, CO2, CO3, BO3 the first two are characters and only the last one is a number | ||
|
||
3) Tech codes: 12 characters | ||
|
||
I) Not following any coding: BACKSTOP | ||
|
||
II) Power generation technologies/Power plants: | ||
|
||
^^^_________: first three characters 01-03 represent country code | ||
|
||
___^^^______: character 04-06 represent the type of fuel (BIO, COA, CHA, CO1, CO2, EL1, EL2, ETH, GEO, HE2, HFO, HYD, LFO, NGA, BIO, URN, SOL, WA2, WIN, LNG) | ||
*LNG is not in the list of fuels but it has been added as a code in the technologies to distinguish between natural gas imports and LNG imports. | ||
|
||
______^^____: character 07-08 represent the type of technology (CH: biomass CHP plant, SC:Superctritical coal, CV: conventional geothermal, GC: gas cycle, LS: large size hydro, MS: medium size hydro, SS: small size hydro, SA: stand alone, RC: ... LFO, CC: combined cycle, PW: pressurized water reactor (nuclear), CN: CSP (without storage), CS: CSP (with storage), PU: PV(utility), PR: PV(roof top), PS: PV (with storage), ON: onshore (wind), OF: offshore (wind) | ||
|
||
________^___: character 09 represent if the technology includes CCS or not. (P: its a power generation tech. without CCS, C: its a power generation tech. with CCS) | ||
|
||
_________^^_: character 10-11 represent the cooling type (00: means that the cooling type is not one of the following; 01-04: AIR, MDT, NDT, OTF/OTS. | ||
|
||
Hint: If its 00 then that means that a cooling type of the following: AIR, MDT, NDT, OTF/OTS has not been assigned to the power generation technology (example: hydro, wind). In example Solar PV has 00 as cooling type but a water factor has been assigned to that technology. | ||
|
||
___________^: character 12 represent if the power plant is Old (code: O) or New (code: N) or if there is no distinction (code: X) | ||
|
||
III) Extraction/import/export technologies: | ||
|
||
^^^_________: first three characters 01-03 represent country code | ||
|
||
___^^^______: character 04-06 represent the type of fuel (BIO, COA, CHA, CO1, CO2, EL1, EL2, ETH, GEO, HE2, HFO, HYD, LFO, NGA, BIO, URN, SOL, WA2, WIN, LNG) | ||
|
||
______^^____: character 07-08 represent the type of technology (IM: imports, PR: production, EX: exports). | ||
Hint: Exports are represented in a different way in this model | ||
|
||
________^___: character 09 will be P in this case. | ||
|
||
_________^^_: character 10-11 represent the cooling type, so code:00 since a cooling type has not been assigned to the technology | ||
|
||
___________^: character 12 since there is no distinction (code: X) | ||
|
||
|
||
IV) Transmission & distribution, Process: | ||
|
||
^^^_________: first three characters 01-03 represent country code | ||
|
||
___^^^______: character 04-06 represent the type of fuel (BIO, COA, CHA, CO1, CO2, EL1, EL2, ETH, GEO, HE2, HFO, HYD, LFO, NGA, BIO, URN, SOL, WA2, WIN, LNG) | ||
|
||
______^^____: character 07-08 represent the type of technology (TR: transmission, DI: distribution) | ||
Hint: the process technologies have DI as code. | ||
|
||
________^___: character 09 will be P in this case. | ||
|
||
_________^^_: character 10-11 represent the cooling type, so code:00 since a cooling type has not been assigned to the technology | ||
|
||
___________^: character 12, since there is no distinction the code: X | ||
|
||
|
||
V) Conversion technologies (new naming ???): | ||
|
||
(old) CRUDPROX --> (new) CO1?????? = Crude oil refinery capacity | ||
(old) CRUDRE1X --> (new) CO2?????? = Crude oil refinery 1 | ||
(old) CRUDRE2X --> (new) CO2?????? = Crude oil refinery 2 | ||
|
||
VI) Trade links ((new naming ???): | ||
1) Exports_EL | ||
(old) ^^EL^^BP00: where ^^ country codes | ||
(new) ^^^EL1EX???? | ||
|
||
## Country codes: 3 characters | ||
|
||
## Fuel codes: 6 characters (Except from the intermediate fuels for NG pipeline) | ||
|
||
|
||
`^^^___`: first three characters 01-03 represent country code | ||
|
||
`___^^^`: last three characters 04-06 | ||
- list of fuels: `ETH, CO1, CO2, BIO, COA, LFO, GAS, HFO, SOL, WIN, URN, CHA, WA1, WA2, EL1, HE2, EL2, FW3, HE3, EL3, HF3, LF3, CH3, GA3, CO3, BO3, CR3, DEL, DLG, DNG` | ||
- the fuels that have number `3` at the end represent the final energy demand `FW3, HE3, EL3, HF3, LF3, CH3, GA3, CO3, BO3, CR3` | ||
- the fuels that have the description `GASP` at the end represent the intermediate fuels for NG pipeline | ||
|
||
** Note: `CO1, CO2, CO3, BO3` the first two are characters and only the last one is a number | ||
|
||
## Tech codes: 12 characters | ||
|
||
### Currently not following any coding | ||
|
||
`BACKSTOP` | ||
|
||
### Power generation technologies/Power plants: | ||
|
||
`^^^_________`: first three characters 01-03 represent country code | ||
|
||
`___^^^______`: character 04-06 represent the type of fuel (`BIO, COA, CHA, CO1, CO2, EL1, EL2, | ||
ETH, GEO, HE2, HFO, HYD, LFO, NGA, BIO, URN, SOL, WA2, WIN, LNG`) . Note `LNG` is not in the list of fuels but it has been added as a code in the technologies to distinguish between natural gas imports and LNG imports. | ||
|
||
`______^^____`: character 07-08 represent the type of technology (`CH`: biomass CHP plant, `SC`:Superctritical coal, `CV`: conventional geothermal, `GC`: gas cycle, `LS`: large size hydro, `MS`: medium size hydro, `SS`: small size hydro, `SA`: stand alone, `RC`: LFO, `CC`: combined cycle, `PW`: pressurized water reactor (nuclear), `CN`: CSP (without storage), `CS`: CSP (with storage), `PU`: PV(utility), `PR`: PV(roof top), `PS`: PV (with storage), `ON`: onshore (wind), `OF`: offshore (wind) | ||
|
||
`________^___`: character 09 represent if the technology includes CCS or not. (`P`: its a power | ||
generation tech. without CCS, `C`: its a power generation tech. with CCS) | ||
|
||
`_________^^_`: character 10-11 represent the cooling type (`00`: means that the cooling type is not one of the following; `01`-`04`: `AIR, MDT, NDT, OTF/OTS`. | ||
|
||
Hint: If it is `00` then that means that a cooling type of the following: AIR, MDT, NDT, OTF/OTS has | ||
not been assigned to the power generation technology (example: hydro, wind). | ||
In example Solar PV has `00` as cooling type but a water factor has been assigned to that technology. | ||
|
||
`___________^`: character 12 represent if the power plant is Old (code: O) or New (code: N) or if there is no distinction (code: X) | ||
|
||
### Extraction/import/export technologies: | ||
|
||
`^^^_________`: first three characters 01-03 represent country code | ||
|
||
`___^^^______`: character 04-06 represent the type of fuel (BIO, COA, CHA, CO1, CO2, EL1, EL2, ETH, GEO, HE2, HFO, HYD, LFO, NGA, BIO, URN, SOL, WA2, WIN, LNG) | ||
|
||
`______^^____`: character 07-08 represent the type of technology (IM: imports, PR: production, EX: exports). | ||
Hint: Exports are represented in a different way in this model | ||
|
||
`________^___`: character 09 will be P in this case. | ||
|
||
`_________^^_`: character 10-11 represent the cooling type, so code:00 since a cooling type has not been assigned to the technology | ||
|
||
`___________^`: character 12 since there is no distinction (code: X) | ||
|
||
|
||
### Transmission & distribution, Process: | ||
|
||
`^^^_________`: first three characters 01-03 represent country code | ||
|
||
`___^^^______`: character 04-06 represent the type of fuel (`BIO, COA, CHA, CO1, CO2, EL1, EL2, ETH, GEO, HE2, HFO, HYD, LFO, NGA, BIO, URN, SOL, WA2, WIN, LNG`) | ||
|
||
`______^^____`: character 07-08 represent the type of technology ( | ||
`TR`: transmission, `DI`: distribution) | ||
Hint: the process technologies have `DI` as code. | ||
|
||
`________^___`: character 09 will be `P` in this case. | ||
|
||
`_________^^_`: character 10-11 represent the cooling type, so code: `00` since a cooling type has not been assigned to the technology | ||
|
||
`___________^`: character 12, since there is no distinction the code: `X` | ||
|
||
|
||
### Conversion technologies (new naming ???): | ||
|
||
- (old) `CRUDPROX` --> (new) `CO1??????` = Crude oil refinery capacity | ||
- (old) `CRUDRE1X` --> (new) `CO2??????` = Crude oil refinery 1 | ||
- (old) `CRUDRE2X` --> (new) `CO2??????` = Crude oil refinery 2 | ||
|
||
## Trade links (new naming ?): | ||
|
||
### Exports_EL | ||
|
||
(old) `^^EL^^BP00`: where ^^ country codes | ||
(new) `^^^EL1EX????` | ||
|
||
2) Exports_NG | ||
(old) ^^NG^^BP00: where ^^ country codes | ||
(new) ^^^NGAEX???? | ||
(old) `^^NG^^BP00`: where ^^ country codes | ||
(new) `^^^NGAEX????` | ||
|
||
VII) Intermediate_NG: | ||
(old)^^NG00IPIX: where ^^ country codes | ||
(new)^^^NGA?????? | ||
(old)`^^NG00IPIX`: where ^^ country codes | ||
(new)`^^^NGA??????` | ||
|
||
|
||
## Emission factors: 6 characters | ||
|
||
`^^^___`: first three characters 01-03 represent country code | ||
|
||
`___^^^`: last three characters represent `CO2`, `REN`. | ||
*the other emission factors have not been used. | ||
|
||
## Timeslices: 4 characters | ||
|
||
4) Emission factors: 6 characters | ||
|
||
^^^___: first three characters 01-03 represent country code | ||
`^^__`: first two characters represent season (S1-S4) | ||
|
||
___^^^: last three characters represent CO2, REN. | ||
*the other emission factors have not been used. | ||
`__^^`: last two characters represent dayparts (D1,D2) | ||
|
||
5) Timeslices: 4 characters | ||
^^__: first two characters represent season (S1-S4) | ||
__^^: last two characters represent dayparts (D1,D2) | ||
|
||
# Old Naming conventions | ||
|
||
# Old Naming conventions (Vignesh has already the scripts to read the technologies/fuels --> to be checked) | ||
(Vignesh has already the scripts to read the technologies/fuels --> to be checked) | ||
|