28 changes: 28 additions & 0 deletions nibe/data/s735.csv
Original file line number Diff line number Diff line change
Expand Up @@ -21,6 +21,9 @@ Average temperature (BT1) MODBUS_INPUT_REGISTER 37 10 °C 2 0 0 0
Boiler temperature (BT52) MODBUS_INPUT_REGISTER 38 10 °C 2 0 0 0
Flow sensor (BF1) MODBUS_INPUT_REGISTER 40 10 l/m 2 0 0 0
Electrical anode (EB100-FR1) MODBUS_INPUT_REGISTER 41 1 2 0 0 0
Current (BE3) MODBUS_INPUT_REGISTER 46 10 A 6 0 0 0
Current (BE2) MODBUS_INPUT_REGISTER 48 10 A 6 0 0 0
Current (BE1) MODBUS_INPUT_REGISTER 50 10 A 6 0 0 0
- MODBUS_INPUT_REGISTER 60 10 °C 2 0 0 0
- MODBUS_INPUT_REGISTER 61 10 °C 2 0 0 0
- MODBUS_INPUT_REGISTER 62 10 °C 2 0 0 0
Expand Down Expand Up @@ -83,6 +86,7 @@ Climate system 8 MODBUS_INPUT_REGISTER 156 1 4 0 0 0
Climate system 7 MODBUS_INPUT_REGISTER 157 1 4 0 0 0
Climate system 6 MODBUS_INPUT_REGISTER 158 1 4 0 0 0
Climate system 5 MODBUS_INPUT_REGISTER 159 1 4 0 0 0
Compressor, total time cooling, main unit (EP14) MODBUS_INPUT_REGISTER 279 1 h 6 0 2147483647 0
Heat pump 8 requested compressor frequency MODBUS_INPUT_REGISTER 294 1 Hz 4 0 0 0
Heat pump 7 requested compressor frequency MODBUS_INPUT_REGISTER 295 1 Hz 4 0 0 0
Heat pump 6 requested compressor frequency MODBUS_INPUT_REGISTER 296 1 Hz 4 0 0 0
Expand Down Expand Up @@ -616,6 +620,11 @@ Exhaust air fan speed 3 MODBUS_HOLDING_REGISTER 106 1 % 4 0 100 80
Exhaust air fan speed 2 MODBUS_HOLDING_REGISTER 107 1 % 4 0 100 30
Exhaust air fan speed 1 MODBUS_HOLDING_REGISTER 108 1 % 4 0 100 0
Exhaust air fan speed normal MODBUS_HOLDING_REGISTER 109 1 % 4 0 100 65
Supply air fan speed 4 MODBUS_HOLDING_REGISTER 110 1 % 4 0 100 90
Supply air fan speed 3 MODBUS_HOLDING_REGISTER 111 1 % 4 0 100 70
Supply air fan speed 2 MODBUS_HOLDING_REGISTER 112 1 % 4 0 100 25
Supply air fan speed 1 MODBUS_HOLDING_REGISTER 113 1 % 4 0 100 0
Supply air fan speed normal MODBUS_HOLDING_REGISTER 114 1 % 4 0 100 60
Return time fan 4 MODBUS_HOLDING_REGISTER 115 1 h 4 1 24 4
Return time fan 3 MODBUS_HOLDING_REGISTER 116 1 h 4 1 24 4
Return time fan 2 MODBUS_HOLDING_REGISTER 117 1 h 4 1 24 4
Expand Down Expand Up @@ -647,6 +656,9 @@ Climate system 3 MODBUS_HOLDING_REGISTER 143 1 4 0 1 0
Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0
Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30
Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2
Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10
Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30
Cooling with room sensors MODBUS_HOLDING_REGISTER 170 10 4 0 41 0
Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 30
Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1
Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1
Expand Down Expand Up @@ -686,13 +698,17 @@ id:3968 MODBUS_HOLDING_REGISTER 2752 1 5 1 3600 5
Preset flow setting for climate system MODBUS_HOLDING_REGISTER 223 1 4 0 3 1
id:3977 MODBUS_HOLDING_REGISTER 2753 1 4 21 22 22
More hot water MODBUS_HOLDING_REGISTER 225 10 - - - -
Fan sync. mode MODBUS_HOLDING_REGISTER 3103 1 4 0 1 0
Night cooling 1 MODBUS_HOLDING_REGISTER 227 1 4 0 1 0
Start temperature night cooling 1 MODBUS_HOLDING_REGISTER 228 1 °C 4 20 30 25
Min diff. for night cooling 1 MODBUS_HOLDING_REGISTER 229 1 °C 4 3 10 6
id:4045 MODBUS_HOLDING_REGISTER 4041 1 °C 1 1 40 8
id:4046 MODBUS_HOLDING_REGISTER 4043 1 °C 1 0 40 4
id:4049 MODBUS_HOLDING_REGISTER 4045 1 4 0 1 0
id:4050 MODBUS_HOLDING_REGISTER 4046 1 4 0 1 0
id:4051 MODBUS_HOLDING_REGISTER 4047 1 4 0 1 0
Oper. mode MODBUS_HOLDING_REGISTER 237 1 4 0 0 0
Cooling heat sensor set point value MODBUS_HOLDING_REGISTER 681 10 2 50 400 210
Manual heating medium pump speed MODBUS_HOLDING_REGISTER 695 1 % 1 0 1 0
More hot water MODBUS_HOLDING_REGISTER 697 1 1 0 0 0
Supp. air curve SAM, outd. temp. (T3) MODBUS_HOLDING_REGISTER 711 10 °C 2 -400 200 150
Expand All @@ -702,12 +718,14 @@ Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T3) MODBUS_HO
Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T2) MODBUS_HOLDING_REGISTER 715 10 °C 2 160 220 180
Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T1) MODBUS_HOLDING_REGISTER 716 10 °C 2 160 220 180
id:4591 MODBUS_HOLDING_REGISTER 4052 1 1 5 80 30
Cooling connected, climate system 1 MODBUS_HOLDING_REGISTER 726 1 4 0 1 1
id:4617 MODBUS_HOLDING_REGISTER 4053 1 1 0 1 0
SCA40/41/42 MODBUS_HOLDING_REGISTER 735 1 4 0 1 0
Max speed, regulator, charge/heating medium pump (EB100) MODBUS_HOLDING_REGISTER 740 1 % 4 50 100 100
id:4660 MODBUS_HOLDING_REGISTER 4063 1 4 0 0 0
Shunted brine, accessory MODBUS_HOLDING_REGISTER 4064 1 4 0 1 0
Shunted brine max. temp. MODBUS_HOLDING_REGISTER 4067 1 °C 4 0 30 20
Additional heat after reversing valve MODBUS_HOLDING_REGISTER 758 1 4 0 0 0
Heating (SG Ready) MODBUS_HOLDING_REGISTER 760 1 4 0 1 1
id:4703 MODBUS_HOLDING_REGISTER 4068 1 4 0 1 0
id:4704 MODBUS_HOLDING_REGISTER 4069 1 4 0 1 0
Expand All @@ -721,6 +739,9 @@ id:4711 MODBUS_HOLDING_REGISTER 0 1 4 0 0 0
Input AUX5 MODBUS_HOLDING_REGISTER 767 1 4 0 65 0
Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 0 0 0
Activated (Smart Price Adaption) MODBUS_HOLDING_REGISTER 843 1 4 0 1 0
(SPA), heating activated (SPA) MODBUS_HOLDING_REGISTER 844 1 4 0 3 1
(SPA), heating influence MODBUS_HOLDING_REGISTER 845 1 1 1 10 5
(SPA), hot water activated MODBUS_HOLDING_REGISTER 846 1 4 0 3 1
(SPA), cooling activated MODBUS_HOLDING_REGISTER 849 1 4 0 1 1
(SPA), area MODBUS_HOLDING_REGISTER 851 1 4 0 254 23
Automatic speed heating medium pump, hot water MODBUS_HOLDING_REGISTER 852 1 % 1 0 1 1
Expand Down Expand Up @@ -1231,6 +1252,7 @@ AUX (EME20) MODBUS_HOLDING_REGISTER 2675 1 4 0 1 0
id:14052 MODBUS_HOLDING_REGISTER 2670 1 kW 6 1 999 1
id:14061 MODBUS_HOLDING_REGISTER 2672 1 4 0 1 0
Temperature, Overload, pool MODBUS_HOLDING_REGISTER 0 1 °C 4 1 50 1
Pump speed (AZ20-GP6) MODBUS_HOLDING_REGISTER 2674 1 % 4 0 0 0
EME20 API MODBUS_HOLDING_REGISTER 2107 1 4 0 1 0
EME20 API Include own consumption MODBUS_HOLDING_REGISTER 2108 1 4 0 1 0
EME20 API Available power MODBUS_HOLDING_REGISTER 2109 1 5 0 65535 0
Expand Down Expand Up @@ -1291,12 +1313,17 @@ Input on ECS1 affects ECS6 MODBUS_HOLDING_REGISTER 2444 1 4 0 1 0
Input on ECS1 affects ECS7 MODBUS_HOLDING_REGISTER 2445 1 4 0 1 0
Input on ECS1 affects ECS8 MODBUS_HOLDING_REGISTER 2446 1 4 0 1 0
External setting for adjustment migrated MODBUS_HOLDING_REGISTER 2503 1 4 0 1 0
Fan speed (AZ20-GQ3) MODBUS_HOLDING_REGISTER 2673 1 % 4 0 0 0
Time between filter replacement MODBUS_HOLDING_REGISTER 2676 1 4 1 24 3
Time between filter replacement MODBUS_HOLDING_REGISTER 2677 1 4 1 24 3
Time between filter replacement MODBUS_HOLDING_REGISTER 2678 1 4 1 24 3
Time between filter replacement MODBUS_HOLDING_REGISTER 2679 1 4 1 24 3
Pressure 1 (SFT10) MODBUS_INPUT_REGISTER 2012 1 5 0 0 0
Pressure 2 (SFT10) MODBUS_INPUT_REGISTER 2123 1 5 0 0 0
Supply line (AZ20-BT68) MODBUS_INPUT_REGISTER 2137 10 °C 2 0 0 0
Outd temperature (AZ20-BT23) MODBUS_INPUT_REGISTER 2139 10 °C 2 0 0 0
Supply air (AZ20-BT22) MODBUS_INPUT_REGISTER 2138 10 °C 2 0 0 0
Return line (AZ20-BT69) MODBUS_INPUT_REGISTER 2140 10 °C 2 0 0 0
Diff. pr. airflow (BP15) MODBUS_INPUT_REGISTER 2130 10 Pa 2 0 0 0
Unfiltered air flow (BP16) MODBUS_INPUT_REGISTER 2131 10 m³/h 2 0 0 0
id:21077 MODBUS_HOLDING_REGISTER 3020 1 4 0 0 0
Expand Down Expand Up @@ -1347,6 +1374,7 @@ Fan mode 5 MODBUS_INPUT_REGISTER 2168 1 % 4 0 0 0
Fan mode 6 MODBUS_INPUT_REGISTER 2169 1 % 4 0 0 0
Fan mode 7 MODBUS_INPUT_REGISTER 2170 1 % 4 0 0 0
Fan mode 8 MODBUS_INPUT_REGISTER 2171 1 % 4 0 0 0
Fan sync operation at high outdoor temperature MODBUS_HOLDING_REGISTER 2762 1 4 0 1 0
id:23462 MODBUS_HOLDING_REGISTER 3101 1 4 0 1 0
id:24408 MODBUS_INPUT_REGISTER 2201 10 m³/h 2 0 0 0
Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 4204 1 4 0 1 0
Expand Down