14 changes: 11 additions & 3 deletions nibe/data/s2125.csv
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
Title Register type Register Division factor Unit Size of variable Min value Max value Default value
Title Register type Register Division factor Unit Size of variable Min value Max value Default value
Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0
Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0
Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0
Expand Down Expand Up @@ -45,8 +45,6 @@ Room average temp. clim. system 2 (BT50) MODBUS_INPUT_REGISTER 115 10 °C 2 0 0
Room average temp. clim. system 1 (BT50) MODBUS_INPUT_REGISTER 116 10 °C 2 0 0 0
External cooling supply temperature (BT25) MODBUS_INPUT_REGISTER 119 10 °C 2 0 0 0
id:193 MODBUS_INPUT_REGISTER 128 1 4 0 0 0
Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0
Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0
Oper. mode shunt climate system 8 MODBUS_INPUT_REGISTER 129 1 4 0 0 0
Oper. mode shunt climate system 7 MODBUS_INPUT_REGISTER 130 1 4 0 0 0
Oper. mode shunt climate system 6 MODBUS_INPUT_REGISTER 131 1 4 0 0 0
Expand All @@ -57,6 +55,8 @@ Fan speed (AZ30-GQ2) MODBUS_INPUT_REGISTER 135 1 % 4 0 0 0
Fan speed (AZ30-GQ3) MODBUS_INPUT_REGISTER 136 1 % 4 0 0 0
Current hot water mode controlled by MODBUS_INPUT_REGISTER 137 1 1 0 0 0
Max. compressor frequency, heating MODBUS_INPUT_REGISTER 141 100 Hz 5 0 0 0
Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0
Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0
External adjustment climate system 8 MODBUS_INPUT_REGISTER 151 1 4 0 0 0
External adjustment climate system 7 MODBUS_INPUT_REGISTER 152 1 4 0 0 0
External adjustment climate system 6 MODBUS_INPUT_REGISTER 153 1 4 0 0 0
Expand Down Expand Up @@ -446,6 +446,7 @@ Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0
Shunt controlled additional heat MODBUS_HOLDING_REGISTER 153 1 4 0 1 0
Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30
Step controlled additional heat accessory MODBUS_HOLDING_REGISTER 158 1 4 0 1 0
DM start step controlled additional heat MODBUS_HOLDING_REGISTER 159 1 DM 2 -2000 -30 -400
Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2
Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10
Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30
Expand All @@ -454,6 +455,7 @@ Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 30
Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1
Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1
Permit cooling MODBUS_HOLDING_REGISTER 182 1 4 0 1 1
Auto mode, start temperature for cooling MODBUS_HOLDING_REGISTER 183 10 °C 2 150 400 250
Auto mode, stop temperature for heating MODBUS_HOLDING_REGISTER 184 10 °C 2 -200 400 170
Auto mode, additional heat stop temperature MODBUS_HOLDING_REGISTER 185 10 °C 2 -250 400 50
Auto mode filter time MODBUS_HOLDING_REGISTER 186 1 h 4 0 48 24
Expand Down Expand Up @@ -525,6 +527,7 @@ id:4710 MODBUS_HOLDING_REGISTER 5279 1 4 0 1 0
Input AUX6 MODBUS_HOLDING_REGISTER 767 1 4 0 68 0
Operating mode circulation pump heating heat pump 1 MODBUS_HOLDING_REGISTER 783 1 4 0 1 1
Operating mode circulation pump hot water heat pump 1 MODBUS_HOLDING_REGISTER 799 1 4 0 1 1
Speed circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 823 1 % 4 1 100 70
Operating mode circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 832 1 4 0 1 1
Speed circulation pump waiting mode heat pump 1 MODBUS_HOLDING_REGISTER 841 1 % 4 1 100 30
Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 1 100 30
Expand Down Expand Up @@ -608,6 +611,7 @@ Flow sensor activated X22 MODBUS_HOLDING_REGISTER 1049 1 4 0 1 0
Max. internal additional heat SG Ready MODBUS_HOLDING_REGISTER 1052 100 kW 2 0 900 900
Limit humidity in the room, cooling climate system 1 MODBUS_HOLDING_REGISTER 1063 1 1 0 1 0
Hysteresis (OPT) MODBUS_HOLDING_REGISTER 1066 1 2 10 2000 100
Activated (EME10) MODBUS_HOLDING_REGISTER 1068 1 4 0 1 0
PV panel affects heating (EME) MODBUS_HOLDING_REGISTER 1069 1 4 0 1 0
PV panel affects hot water (EME) MODBUS_HOLDING_REGISTER 1070 1 4 0 1 0
Delay timer EME MODBUS_HOLDING_REGISTER 1071 1 5 0 0 0
Expand Down Expand Up @@ -665,6 +669,7 @@ Start day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTE
End day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1281 1 4 1 31 31
Start month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1282 1 4 1 12 1
End month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1283 1 4 1 12 12
Prioritise additional heat (AXC40) MODBUS_HOLDING_REGISTER 1320 1 4 0 1 0
Max difference, SES priority 1 energy source MODBUS_HOLDING_REGISTER 1326 10 °C 2 10 250 100
Max difference, SES lower priority energy source MODBUS_HOLDING_REGISTER 1327 10 °C 2 10 250 70
Installed (EB101) MODBUS_HOLDING_REGISTER 1550 1 4 0 1 1
Expand Down Expand Up @@ -772,6 +777,7 @@ Factor MODBUS_HOLDING_REGISTER 3033 1 4 1 10 5
id:10881 MODBUS_HOLDING_REGISTER 3062 1 4 0 1 0
id:10890 MODBUS_HOLDING_REGISTER 3063 1 4 0 1 0
Hot water start (BT5) MODBUS_INPUT_REGISTER 2014 10 °C 2 0 0 0
Pump: Heating medium (GP6) MODBUS_INPUT_REGISTER 2128 1 4 0 0 0
id:12332 MODBUS_HOLDING_REGISTER 2767 1 2 -32768 32767 -32768
id:12333 MODBUS_HOLDING_REGISTER 2768 1 2 -32768 32767 -32768
id:12334 MODBUS_HOLDING_REGISTER 2769 1 2 -32768 32767 -32768
Expand Down Expand Up @@ -1472,6 +1478,8 @@ id:55082 MODBUS_HOLDING_REGISTER 2883 1 4 0 1 0
id:55083 MODBUS_HOLDING_REGISTER 2884 1 4 0 1 0
Immersion heater power, emergency mode MODBUS_HOLDING_REGISTER 3028 100 kW 2 0 4500 600
Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 3986 1 4 0 1 0
Return line (AZ2-BT69) MODBUS_INPUT_REGISTER 2190 10 °C 2 0 0 0
Supply line (AZ2-BT68) MODBUS_INPUT_REGISTER 2191 10 °C 2 0 0 0
"EEV Control Mode (EB101)" MODBUS_INPUT_REGISTER 2413 1 4 0 0 0
"EEV State (EB101)" MODBUS_INPUT_REGISTER 2421 1 4 0 0 0
id:55495 MODBUS_HOLDING_REGISTER 5550 1 4 0 1 0
Expand Down
97 changes: 85 additions & 12 deletions nibe/data/s2125.json
Original file line number Diff line number Diff line change
Expand Up @@ -263,18 +263,6 @@
"size": "s16",
"name": "external-cooling-supply-temperature-bt25-30120"
},
"30143": {
"title": "Inverter alarm code",
"factor": 1,
"size": "u16",
"name": "inverter-alarm-code-30143"
},
"30144": {
"title": "Inverter alarm code",
"factor": 1,
"size": "u16",
"name": "inverter-alarm-code-30144"
},
"30130": {
"title": "Oper. mode shunt climate system 8",
"factor": 1,
Expand Down Expand Up @@ -332,6 +320,18 @@
"size": "u16",
"name": "max-compressor-frequency-heating-30142"
},
"30143": {
"title": "Inverter alarm code",
"factor": 1,
"size": "u16",
"name": "inverter-alarm-code-30143"
},
"30144": {
"title": "Inverter alarm code",
"factor": 1,
"size": "u16",
"name": "inverter-alarm-code-30144"
},
"30152": {
"title": "External adjustment climate system 8",
"factor": 1,
Expand Down Expand Up @@ -3071,6 +3071,17 @@
"name": "step-controlled-additional-heat-accessory-40159",
"write": true
},
"40160": {
"title": "DM start step controlled additional heat",
"factor": 1,
"unit": "DM",
"size": "s16",
"min": -2000.0,
"max": -30.0,
"default": -400.0,
"name": "dm-start-step-controlled-additional-heat-40160",
"write": true
},
"40166": {
"title": "Waiting time cooling/heating",
"factor": 1,
Expand Down Expand Up @@ -3155,6 +3166,17 @@
"name": "permit-cooling-40183",
"write": true
},
"40184": {
"title": "Auto mode, start temperature for cooling",
"factor": 10,
"unit": "\u00b0C",
"size": "s16",
"min": 150.0,
"max": 400.0,
"default": 250.0,
"name": "auto-mode-start-temperature-for-cooling-40184",
"write": true
},
"40185": {
"title": "Auto mode, stop temperature for heating",
"factor": 10,
Expand Down Expand Up @@ -3693,6 +3715,17 @@
"name": "operating-mode-circulation-pump-hot-water-heat-pump-1-40800",
"write": true
},
"40824": {
"title": "Speed circulation pump cooling heat pump 1",
"factor": 1,
"unit": "%",
"size": "u8",
"min": 1.0,
"max": 100.0,
"default": 70.0,
"name": "speed-circulation-pump-cooling-heat-pump-1-40824",
"write": true
},
"40833": {
"title": "Operating mode circulation pump cooling heat pump 1",
"factor": 1,
Expand Down Expand Up @@ -4495,6 +4528,16 @@
"name": "hysteresis-opt-41067",
"write": true
},
"41069": {
"title": "Activated (EME10)",
"factor": 1,
"size": "u8",
"min": 0.0,
"max": 1.0,
"default": 0.0,
"name": "activated-eme10-41069",
"write": true
},
"41070": {
"title": "PV panel affects heating (EME)",
"factor": 1,
Expand Down Expand Up @@ -5059,6 +5102,16 @@
"name": "end-month-tariff-ext-step-add-heat-smart-energy-source-41284",
"write": true
},
"41321": {
"title": "Prioritise additional heat (AXC40)",
"factor": 1,
"size": "u8",
"min": 0.0,
"max": 1.0,
"default": 0.0,
"name": "prioritise-additional-heat-axc40-41321",
"write": true
},
"41327": {
"title": "Max difference, SES priority 1 energy source",
"factor": 10,
Expand Down Expand Up @@ -5689,6 +5742,12 @@
"size": "s16",
"name": "hot-water-start-bt5-32015"
},
"32129": {
"title": "Pump: Heating medium (GP6)",
"factor": 1,
"size": "u8",
"name": "pump-heating-medium-gp6-32129"
},
"43089": {
"title": "Period",
"factor": 1,
Expand Down Expand Up @@ -7220,6 +7279,20 @@
"name": "disable-emergency-restart-gp1-43987",
"write": true
},
"32191": {
"title": "Return line (AZ2-BT69)",
"factor": 10,
"unit": "\u00b0C",
"size": "s16",
"name": "return-line-az2-bt69-32191"
},
"32192": {
"title": "Supply line (AZ2-BT68)",
"factor": 10,
"unit": "\u00b0C",
"size": "s16",
"name": "supply-line-az2-bt68-32192"
},
"32414": {
"title": "EEV Control Mode (EB101)",
"factor": 1,
Expand Down