Updated OfflineRecordingExplained.md for Polar 360
Browse files Browse the repository at this point in the history
Document was too focused on Verity Sense implementation. Improved the product table to mark which feature are available for each product and what the memory limits values are.
  • Loading branch information
jimmyzumthurm authored Nov 20, 2024
1 parent 97bd59f commit f88f094
Showing 1 changed file with 13 additions and 12 deletions.
25 changes: 13 additions & 12 deletions documentation/OfflineRecordingExplained.md
Original file line number Diff line number Diff line change
Expand Up @@ -33,27 +33,28 @@ Triggers are the way to automatically start the offline recording. The options a

The API `setOfflineRecordingTrigger` is used to setup the trigger. When the offline recording is automatically started by the trigger the recording will end in two conditions, either recording is stopped by `stopOfflineRecording` or user switch off the device. To disable the trigger the `setOfflineRecordingTrigger` function is called with the option `TRIGGER_DISABLED`

## Memory management

The device does not automatically erase offline recordings to make space for new ones. If there is less than 2 MB of memory left when a new recording is started, the device will respond with the `DISK_FULL` error when `startOfflineRecording` is subscribed. Similarly, the same 2 MB memory limit prevents the setting of new triggers with `setOfflineRecordingTrigger`.
**Security**

In addition, please note that the device will automatically stop the offline recording when there is less than 300 kB of free space remaining. At this point, all offline recording triggers will also be disabled.
The offline record saved in device memory can be encrypted by providing the 128bit AES key as parameter for `startOfflineRecording` request. If providing the key with the `startOfflineRecording` request, the exact same key must be provided in `getOfflineRecord` to be able to read out the offline record. Each of the started recoding may be started with different key. The key management is not provided by the SDK, but the application developer shall implement the key management. It is recommended the security option is used, otherwise it might be possible by others to read out recordings in VeritySense.

## Memory management

## Security
The device does not automatically erase offline recordings to make space for new ones. There are 2 different memory limits :

The offline record saved in device memory can be encrypted by providing the 128bit AES key as parameter for `startOfflineRecording` request. If providing the key with the `startOfflineRecording` request, the exact same key must be provided in `getOfflineRecord` to be able to read out the offline record. Each of the started recoding may be started with different key. The key management is not provided by the SDK, but the application developer shall implement the key management. It is recommended the security option is used, otherwise it might be possible by others to read out recordings in VeritySense.
- Memory limit 1 : Once free space is below that limit, attemping to start a recording or enable any trigger will return `ERROR_DISK_FULL` error.
- Memory limit 2 : Once free space is below that limit, all active offline recordings are automatically stopped and triggered recordings are disabled.

## Availability
To anticipate this scenario, the disk space can be queried to the device by calling `getDiskSpace` function at any time.

| Device | Version onwards |
|:-------------------|:---------------:|
| Polar Verity Sense |2.1.0 |
| Polar 360 |1.0 |
## Product specific availability and details

| Device | From ver. onwards | Offline recording triggers | Security | Memory limit 1 | Memory limit 2 |
|:-------------------|:-----------------:|:--------------------------:|:--------:|:--------------:|:--------------:|
| Polar Verity Sense |2.1.0 | Yes | Yes | 2 MB | 300 KB
| Polar 360 |1.0 | No | No | 2 MB | 2 MB

## Considerations

The online streaming and offline recording do not work same time for the same data type. For example if either accelerometer offline recording or the accelerometer online streaming is started, the attempt to start the online streaming or offline recording at this state will return the error ERROR_ALREADY_IN_STATE.
The online streaming and offline recording do not work same time for the same data type. For example if either accelerometer offline recording or the accelerometer online streaming is started, the attempt to start the online streaming or offline recording at this state will return the error `ERROR_ALREADY_IN_STATE`.

The offline recording read `getOfflineRecord` and delete `removeOfflineRecord` can be called while the offline recording is recording, but that is not recommended. It is recommended to stop the offline recording by `stopOfflineRecording` before trying to access the recording with `getOfflineRecord` or `removeOfflineRecord` functions.