Skip to content

Conversation

HatsyRei
Copy link
Member

WI: AB#2918589

Discovered an issue with Bluefin ethernet interface not detecting link up/down correctly due to missing PHY enumeration. Specifying PHY for both ports resolves this issue.

Testing: Deployed kernel changes on 9189, verify that ethernet functionality and link status correctness based on presence of ethernet connection to both ports.

Marvell 88E6341 'Topaz' ethernet switch on Bluefin hardware has 6 ports,
of which port 1 to 4 PHYs are mapped at SMI addresses from 0x11 to 0x14.
Specify and bind them to the exposed ports on Bluefin devices.

Signed-off-by: HatsyRei <[email protected]>
@gratian gratian requested a review from a team March 26, 2025 15:19
@gratian gratian merged commit 068c975 into ni:nilrt/master/6.6 Mar 26, 2025
1 check passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment