heater: 5 sec stabilization time after switching to closed loop #222
base: master
Are you sure you want to change the base?
Conversation
have a log? |
Or maybe this is caused by rapidly increased heater PWM? Unlikely. |
That’s pretty strange. It makes me question the accuracy of the ESR measurement… |
What happens if you postpone activating the pump until the sensor is fully warm? |
I'll do some testing later. |
Pump control enabled only after sensor reaches |
seems like at least worth a comment explaining that finding |
|
So it seems the same bump up in ESR is still there on 4.9, but not as severe, so it doesn't trip underheat. |
@mck1117 this was rebased please revisit this PR (fails same as master, will rebase on master when master gets green) |
LSU4.2 falls to Underheated state right after switch to closed loop due to rise of sensorEsr (due to applied pump current?)
LSU4.2 falls to Underheated state right after switch to closed loop due to rise of sensorEsr (due to applied pump current?)