TBDDocument
-
Building
-
Zone
tbdZone.Length: This is the maximum length between two edges in the Zone. This is an internal value and is used internally for checking geometry. tbdZone.facadeLength: This value is the exposed length of the façade at a height of 1.1m and is defined in the NCM document. It is used for the Criterion 3 Solar gain check to calculate the limiting solar value. tbdZone.exposedPerimeter: This is the exposed length of the perimeter of the Zone at a height of 0m. If the Zone is on the ground floor and the ground construction has an F-factor this length is used to calculate the additional heat loss.
-
ZoneSurfaces
Number Orientation GUID Area BuildingElement.Name
-
RoomSurfaces
Area Perimeter Face Polygon Hole
-
Polygon Point
-
Point
Here is explanation about Constructions: each ZoneSurfaces - have assigned Building Element
- Building Element (only 1 per building element .ghost it is null)
- Construction
- Material Layers