DA\_Ephys
---------

- Support stimsets with per-sweep ITI. This also changes how the ITI is
calculated for a set of sweeps, as now only the active sets are taken into
account and not all sets in range anymore.
- Complain if the calculated number of sweeps in the set is zero
- Check free disc space before acquisition
- Add minimum sampling interval table for ITC16/ITC16USB
- Complain better on known ITC issues for first time users
- Fix acquisition order when changing tabs during DAQ with indexing turned on
- Avoid indexing errors when changing Repeat Sets/Lists during DAQ
- Apply on mode switch: Fix cases where the headstage and the DA/AD
numerical values don't match
- Apply on mode switch: Fix some edge cases with indexing
- Make TPStorage resizing faster
- Testpulse Multi Device: Try selecting the device first
This handles some edge case experiments better which have the TP stored as
running and are then reopened.

ExperimentConfig
----------------

- Changed I-Clamp primary gain to 5 from 1
- Recursively create the folders to save the experiment

General
-------

- Support stopping Igor Pro via `Quit/N` while the testpulse is running. We
now don't crash anymore.
- Save and clear: Delete Databrowser, Cache and reset history capturing

ITC XOP 2
----------

- Use current version of ITCXOP2 for IP8 as well

MCC XOP
-------
- The XOP now works on a real 32bit Windows

MIESUtils XOP
-------------

- New function MU_GetFreeDiskSpace

Labnotebook
-----------

New numerical keys
~~~~~~~~~~~~~~~~

- Digitizer Hardware Type

Pressure Control
----------------

- Make breakin work again with NI hardware
- P_SetAndGetPressure now returns the real psi and not the calibrated one

WaveBuilder
-----------

- Reorganize controls and add per sweep ITI controls
- Due to the new per-sweep ITI the version of the stimset wave note has changed as well
- Create a newly saved stimset in the stimset folder so that it can be used
immediately without the need to recreate it.
- Speedup delta calculation

Internal
--------

- Fix the bitrotted sampling interval calculation code
- Documentation: Don't syntax highlight verbatim blocks
- Enhance the debug panel
- DEBUGPRINT/DEBUGPRINTw: Add support for outputting waves
- Updated BackgroundWatchdog: New Panel Design, works with any background task
shows up to 15 tasks

Tango
-----

- Changed the delimiter character from ; to | for the cmdID passing