From f89e3ab6729c1e1df0d519cedf5c489392eb0fe6 Mon Sep 17 00:00:00 2001 From: Martijn Russchen Date: Thu, 23 Jan 2025 21:39:38 +0100 Subject: [PATCH 1/3] Updates for S2125 --- nibe/data/s2125.csv | 397 +++++++++++++++++++++++++++++------------ nibe/data/s2125.json | 409 +++++++++++++------------------------------ 2 files changed, 406 insertions(+), 400 deletions(-) diff --git a/nibe/data/s2125.csv b/nibe/data/s2125.csv index c8c5b9c..810bfbc 100755 --- a/nibe/data/s2125.csv +++ b/nibe/data/s2125.csv @@ -1,4 +1,4 @@ -Title Register type Register Division factor Unit Size of variable Min value Max value Default value +Title Register type Register Division factor Unit Size of variable Min value Max value Default value Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0 Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0 Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0 @@ -7,13 +7,11 @@ Supply line (BT2) MODBUS_INPUT_REGISTER 5 10 °C 2 0 0 0 Return line (BT3) MODBUS_INPUT_REGISTER 7 10 °C 2 0 0 0 Hot water top (BT7) MODBUS_INPUT_REGISTER 8 10 °C 2 0 0 0 Hot water charging (BT6) MODBUS_INPUT_REGISTER 9 10 °C 2 0 0 0 -Roomsensor 1-1 MODBUS_INPUT_REGISTER 26 10 °C 2 0 0 0 Temperature limiter (EB100-FD1) MODBUS_INPUT_REGISTER 36 1 2 0 0 0 Average temperature (BT1) MODBUS_INPUT_REGISTER 37 10 °C 2 0 0 0 Boiler temperature (BT52) MODBUS_INPUT_REGISTER 38 10 °C 2 0 0 0 Flow sensor (BF1) MODBUS_INPUT_REGISTER 40 10 l/m 2 0 0 0 Electrical anode (EB100-FR1) MODBUS_INPUT_REGISTER 41 1 2 0 0 0 -Current (BE3) MODBUS_INPUT_REGISTER 46 10 A 6 0 0 0 - MODBUS_INPUT_REGISTER 60 10 °C 2 0 0 0 - MODBUS_INPUT_REGISTER 61 10 °C 2 0 0 0 - MODBUS_INPUT_REGISTER 62 10 °C 2 0 0 0 @@ -55,8 +53,6 @@ Fan speed (AZ30-GQ2) MODBUS_INPUT_REGISTER 135 1 % 4 0 0 0 Fan speed (AZ30-GQ3) MODBUS_INPUT_REGISTER 136 1 % 4 0 0 0 Current hot water mode controlled by MODBUS_INPUT_REGISTER 137 1 1 0 0 0 Max. compressor frequency, heating MODBUS_INPUT_REGISTER 141 100 Hz 5 0 0 0 -Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 -Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 External adjustment climate system 8 MODBUS_INPUT_REGISTER 151 1 4 0 0 0 External adjustment climate system 7 MODBUS_INPUT_REGISTER 152 1 4 0 0 0 External adjustment climate system 6 MODBUS_INPUT_REGISTER 153 1 4 0 0 0 @@ -84,22 +80,6 @@ Available compressors heating MODBUS_INPUT_REGISTER 317 1 4 0 0 0 Available compressors hot water MODBUS_INPUT_REGISTER 318 1 4 0 0 0 Available compressors pool 1 MODBUS_INPUT_REGISTER 319 1 4 0 0 0 Available compressors cooling MODBUS_INPUT_REGISTER 321 1 4 0 0 0 -+Adjust, port MODBUS_INPUT_REGISTER 327 1 4 0 0 0 -+Adjust, operating mode MODBUS_INPUT_REGISTER 328 1 4 0 0 0 -+Adjust, comfort MODBUS_INPUT_REGISTER 329 1 4 0 0 0 -+Adjust, parallel adjustment MODBUS_INPUT_REGISTER 330 1 1 0 0 0 -+Adjust, humidity MODBUS_INPUT_REGISTER 331 10 %RH 2 0 0 0 -+Adjust, indoor temperature MODBUS_INPUT_REGISTER 332 10 °C 2 0 0 0 -+Adjust, outdoor temperature MODBUS_INPUT_REGISTER 333 10 °C 2 0 0 0 -+Adjust, version MODBUS_INPUT_REGISTER 334 1 5 0 0 0 -+Adjust, active MODBUS_INPUT_REGISTER 335 1 4 0 0 0 -+Adjust, demand MODBUS_INPUT_REGISTER 336 1 4 0 0 0 -+Adjust, parallel factor MODBUS_HOLDING_REGISTER 1 1 1 1 10 5 -+Adjust, Parallel (min-max) MODBUS_HOLDING_REGISTER 2 1 1 1 100 100 -Humidity (BM1) MODBUS_INPUT_REGISTER 323 10 % 2 0 0 0 -Temperature (BM1) MODBUS_INPUT_REGISTER 324 10 °C 2 0 0 0 -Pressure (BM1) MODBUS_INPUT_REGISTER 325 10 kPa 2 0 0 0 -Dew point (BM1) MODBUS_INPUT_REGISTER 326 10 °C 2 0 0 0 Supply temperature (BT64) MODBUS_INPUT_REGISTER 337 10 °C 2 0 0 0 Heat pump functionality 2 MODBUS_INPUT_REGISTER 338 1 6 0 0 0 Status (S135) MODBUS_INPUT_REGISTER 344 1 4 0 0 0 @@ -108,8 +88,6 @@ Status, demand, fan speed (S135) MODBUS_INPUT_REGISTER 346 1 4 0 0 0 Status, solenoid (S135) MODBUS_INPUT_REGISTER 347 1 4 0 0 0 Status, compressor, heater(S135) MODBUS_INPUT_REGISTER 348 1 4 0 0 0 Status, compressor, demand (S135) MODBUS_INPUT_REGISTER 350 1 4 0 0 0 -No. of starts (S135) MODBUS_INPUT_REGISTER 351 1 6 0 9999999 0 -Operating time (S135) MODBUS_INPUT_REGISTER 353 1 h 6 0 9999999 0 Degree minutes MODBUS_HOLDING_REGISTER 11 10 DM 3 -30000 30000 0 Blocking (ERS 1) MODBUS_INPUT_REGISTER 358 1 4 0 0 0 AZ30-EB17 MODBUS_INPUT_REGISTER 359 1 4 0 0 0 @@ -141,7 +119,7 @@ Max fan speed (EB101) MODBUS_INPUT_REGISTER 402 1 rpm 5 0 0 0 Min fan speed (EB101) MODBUS_INPUT_REGISTER 403 1 rpm 5 0 0 0 Max compressor speed (EB101) MODBUS_INPUT_REGISTER 404 10 Hz 5 0 0 0 Min compressor speed (EB101) MODBUS_INPUT_REGISTER 405 10 Hz 5 0 0 0 -Generated power (EB101) MODBUS_INPUT_REGISTER 406 10 kW 5 0 0 0 +Generated power heating (EB101) MODBUS_INPUT_REGISTER 406 10 kW 5 0 0 0 Time to defrosting (EB101) MODBUS_INPUT_REGISTER 407 1 min 5 0 0 0 Defrosting index (EB101) MODBUS_INPUT_REGISTER 408 1 5 0 0 0 Superheat reference EEV (EB101) MODBUS_INPUT_REGISTER 409 10 °C 2 0 0 0 @@ -173,7 +151,6 @@ Fan status (EB101-EP14) MODBUS_INPUT_REGISTER 556 1 4 0 0 0 Fan rpm (EB101-EP14) MODBUS_INPUT_REGISTER 557 1 rpm 5 0 0 0 High condenser out alarm (S135) MODBUS_INPUT_REGISTER 575 1 5 0 0 0 High condenser in alarm (S135) MODBUS_INPUT_REGISTER 576 1 5 0 0 0 -Average current (EME 10) MODBUS_INPUT_REGISTER 578 10 A 2 0 0 0 Operating mode PV panels MODBUS_INPUT_REGISTER 579 1 4 0 0 0 EME lux mode without EME MODBUS_INPUT_REGISTER 581 1 4 0 0 0 Timer (EME) MODBUS_INPUT_REGISTER 582 60 min 5 0 0 0 @@ -242,7 +219,7 @@ Max fan speed (EB100) MODBUS_INPUT_REGISTER 937 1 rpm 5 0 0 0 Min fan speed (EB100) MODBUS_INPUT_REGISTER 938 1 rpm 5 0 0 0 Max compressor speed (EB100) MODBUS_INPUT_REGISTER 939 10 Hz 5 0 0 0 Min compressor speed (EB100) MODBUS_INPUT_REGISTER 940 10 Hz 5 0 0 0 -Generated power (EB100) MODBUS_INPUT_REGISTER 941 10 kW 5 0 0 0 +Generated power heating (EB100) MODBUS_INPUT_REGISTER 941 10 kW 5 0 0 0 Time to defrosting (EB100) MODBUS_INPUT_REGISTER 942 1 min 5 0 0 0 Defrosting index (EB100) MODBUS_INPUT_REGISTER 943 1 5 0 0 0 Superheat reference (EEV)(EB100) MODBUS_INPUT_REGISTER 944 10 °C 2 0 0 0 @@ -308,7 +285,7 @@ Docked compressors pool 1 MODBUS_INPUT_REGISTER 1110 1 4 0 0 0 Reversing valve hot water (QN10) MODBUS_INPUT_REGISTER 2196 1 4 0 0 0 Operating mode step controlled additional heat MODBUS_INPUT_REGISTER 1115 1 4 0 0 0 Relay status, base board (EB100-EP14) MODBUS_INPUT_REGISTER 1117 1 4 0 0 0 -Relay status, imm. heat. board (EB100-EP14) MODBUS_INPUT_REGISTER 1119 1 4 0 0 0 +Relay status, imm. heat. board (EB100-EP14) MODBUS_INPUT_REGISTER 1119 1 5 0 0 0 Current status MODBUS_INPUT_REGISTER 1120 1 6 0 0 0 Functionality, heat pump (EP14) MODBUS_INPUT_REGISTER 1122 1 6 0 0 0 Active heat pumps MODBUS_INPUT_REGISTER 1124 1 5 0 0 0 @@ -329,7 +306,7 @@ Compressor, time to start (EB101-EP14) MODBUS_INPUT_REGISTER 1485 1 min 4 0 0 0 Compressor, number of starts (EB101-EP14) MODBUS_INPUT_REGISTER 1489 1 6 0 2147483647 0 Compressor, oper. time, total (EB101-EP14) MODBUS_INPUT_REGISTER 1491 1 h 6 0 2147483647 0 Compressor, oper. time, hot water (EB101-EP14) MODBUS_INPUT_REGISTER 1493 1 h 6 0 2147483647 0 -Alarm number (EB101-EP14) MODBUS_INPUT_REGISTER 1495 1 5 0 0 0 +Alarm number (EB101) MODBUS_INPUT_REGISTER 1495 1 5 0 0 0 Heat pump type (EB100) MODBUS_INPUT_REGISTER 1497 1 4 0 0 0 Compressor size (EB100) MODBUS_INPUT_REGISTER 1498 1 4 0 0 0 Compressor, requested (EB101-EP14) MODBUS_INPUT_REGISTER 1556 1 4 0 0 0 @@ -339,8 +316,7 @@ Blocked compressors MODBUS_INPUT_REGISTER 2174 1 6 0 0 0 Cooling degree minutes MODBUS_HOLDING_REGISTER 20 10 DM 2 -30000 30000 0 Calculated cooling supply climate system 1 MODBUS_INPUT_REGISTER 1567 10 °C 2 0 0 0 id:2728 MODBUS_HOLDING_REGISTER 3099 1 3 0 9999999 0 -Speed (GP12) MODBUS_INPUT_REGISTER 1589 1 % 4 0 0 0 -Cooling pump manual speed MODBUS_HOLDING_REGISTER 21 1 % 1 1 100 70 +Cooling pump manual speed MODBUS_HOLDING_REGISTER 21 1 % 4 1 100 70 Outdoor temperature (EB101-BT28) MODBUS_INPUT_REGISTER 1621 10 °C 2 0 0 0 Evaporator (EB101-BT16) MODBUS_INPUT_REGISTER 1622 10 °C 2 0 0 0 Heating medium pump speed (GP1) MODBUS_INPUT_REGISTER 1636 1 % 4 0 0 0 @@ -366,7 +342,6 @@ Current sensor (EB101-EP14) MODBUS_INPUT_REGISTER 1903 10 A 2 0 0 0 Operating mode (SG Ready) MODBUS_INPUT_REGISTER 1911 1 4 0 0 0 SG ready, input A MODBUS_INPUT_REGISTER 1912 1 4 0 0 0 SG ready, input B MODBUS_INPUT_REGISTER 1913 1 4 0 0 0 -Heating offset (SPA) MODBUS_INPUT_REGISTER 1914 10 1 0 0 0 Hot water comfort mode (SPA) MODBUS_INPUT_REGISTER 1915 1 1 0 0 0 Pool offset (SPA) MODBUS_INPUT_REGISTER 1916 1 1 0 0 0 Cooling offset (SPA) MODBUS_INPUT_REGISTER 1917 1 1 0 0 0 @@ -399,13 +374,13 @@ Point offset MODBUS_HOLDING_REGISTER 47 1 °C 1 -10 10 0 External adjustment climate system 1 MODBUS_HOLDING_REGISTER 51 1 1 -10 10 0 External adjustment with room sensor climate system 1 MODBUS_HOLDING_REGISTER 55 10 °C 2 50 300 200 Hot water demand mode MODBUS_HOLDING_REGISTER 56 1 1 0 4 1 -Start temperature HW high temperature MODBUS_HOLDING_REGISTER 58 10 °C 2 50 700 440 -Start temperature HW normal temperature MODBUS_HOLDING_REGISTER 59 10 °C 2 50 700 410 -Start temperature HW low temperature MODBUS_HOLDING_REGISTER 60 10 °C 2 50 700 380 +Start temperature HW high temperature MODBUS_HOLDING_REGISTER 58 10 °C 2 50 700 530 +Start temperature HW normal temperature MODBUS_HOLDING_REGISTER 59 10 °C 2 50 700 480 +Start temperature HW low temperature MODBUS_HOLDING_REGISTER 60 10 °C 2 50 700 430 Stop temperature HW periodic increase MODBUS_HOLDING_REGISTER 61 10 °C 2 550 700 550 -Stop temperature HW high temperature MODBUS_HOLDING_REGISTER 62 10 °C 2 50 700 480 -Stop temperature HW normal temperature MODBUS_HOLDING_REGISTER 63 10 °C 2 50 700 450 -Stop temperature HW low temperature MODBUS_HOLDING_REGISTER 64 10 °C 2 50 700 420 +Stop temperature HW high temperature MODBUS_HOLDING_REGISTER 62 10 °C 2 50 700 550 +Stop temperature HW normal temperature MODBUS_HOLDING_REGISTER 63 10 °C 2 50 700 510 +Stop temperature HW low temperature MODBUS_HOLDING_REGISTER 64 10 °C 2 50 700 480 Periodic hot water MODBUS_HOLDING_REGISTER 65 1 1 0 1 1 Periodic hot water interval MODBUS_HOLDING_REGISTER 66 1 days 1 1 90 7 Start time periodic hot water MODBUS_HOLDING_REGISTER 67 1 - - - - @@ -419,9 +394,9 @@ DM start heating MODBUS_HOLDING_REGISTER 97 1 DM 2 -1000 -30 -60 DM between additional heat step MODBUS_HOLDING_REGISTER 100 1 DM 2 10 1000 100 Max. internal additional heat MODBUS_HOLDING_REGISTER 102 100 kW 2 0 4500 900 Fuse MODBUS_HOLDING_REGISTER 103 1 A 5 1 400 16 -id:3826 MODBUS_HOLDING_REGISTER 2747 1 4 1 128 4 -id:3827 MODBUS_HOLDING_REGISTER 2746 1 4 1 128 2 -id:3828 MODBUS_HOLDING_REGISTER 2745 1 4 1 128 1 +Phase Order L3 MODBUS_HOLDING_REGISTER 2747 1 4 1 128 4 +Phase Order L2 MODBUS_HOLDING_REGISTER 2746 1 4 1 128 2 +Phase Order L1 MODBUS_HOLDING_REGISTER 2745 1 4 1 128 1 Floor drying MODBUS_HOLDING_REGISTER 120 1 4 0 1 0 Floor drying period 7 MODBUS_HOLDING_REGISTER 121 1 days 4 0 30 2 Floor drying period 6 MODBUS_HOLDING_REGISTER 122 1 days 4 0 30 2 @@ -446,7 +421,6 @@ Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0 Shunt controlled additional heat MODBUS_HOLDING_REGISTER 153 1 4 0 1 0 Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30 Step controlled additional heat accessory MODBUS_HOLDING_REGISTER 158 1 4 0 1 0 -DM start step controlled additional heat MODBUS_HOLDING_REGISTER 159 1 DM 2 -2000 -30 -400 Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2 Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10 Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30 @@ -455,7 +429,6 @@ Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 30 Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1 Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1 Permit cooling MODBUS_HOLDING_REGISTER 182 1 4 0 1 1 -Auto mode, start temperature for cooling MODBUS_HOLDING_REGISTER 183 10 °C 2 150 400 250 Auto mode, stop temperature for heating MODBUS_HOLDING_REGISTER 184 10 °C 2 -200 400 170 Auto mode, additional heat stop temperature MODBUS_HOLDING_REGISTER 185 10 °C 2 -250 400 50 Auto mode filter time MODBUS_HOLDING_REGISTER 186 1 h 4 0 48 24 @@ -477,16 +450,16 @@ Room sensor factor climate system 4 MODBUS_HOLDING_REGISTER 207 10 4 0 60 20 Room sensor factor climate system 3 MODBUS_HOLDING_REGISTER 208 10 4 0 60 20 Room sensor factor climate system 2 MODBUS_HOLDING_REGISTER 209 10 4 0 60 20 Room sensor factor climate system 1 MODBUS_HOLDING_REGISTER 210 10 4 0 60 20 -Input AUX5 MODBUS_HOLDING_REGISTER 211 1 4 0 67 0 -Input AUX4 MODBUS_HOLDING_REGISTER 212 1 4 0 67 0 -Input AUX3 MODBUS_HOLDING_REGISTER 213 1 4 0 67 0 -Input AUX2 MODBUS_HOLDING_REGISTER 214 1 4 0 67 0 -Input AUX1 MODBUS_HOLDING_REGISTER 215 1 4 0 67 0 +Input AUX5 MODBUS_HOLDING_REGISTER 211 1 4 0 68 0 +Input AUX4 MODBUS_HOLDING_REGISTER 212 1 4 0 68 0 +Input AUX3 MODBUS_HOLDING_REGISTER 213 1 4 0 68 0 +Input AUX2 MODBUS_HOLDING_REGISTER 214 1 4 0 68 0 +Input AUX1 MODBUS_HOLDING_REGISTER 215 1 4 0 68 0 Output AUX1 MODBUS_HOLDING_REGISTER 216 1 4 0 30 0 id:3968 MODBUS_HOLDING_REGISTER 2752 1 5 1 3600 5 Preset flow setting for climate system MODBUS_HOLDING_REGISTER 223 1 4 0 3 1 id:3977 MODBUS_HOLDING_REGISTER 2753 1 4 21 22 22 -More hot water MODBUS_HOLDING_REGISTER 225 1 5 0 0 0 +More hot water (Number of minutes) MODBUS_HOLDING_REGISTER 225 1 5 0 0 0 id:4045 MODBUS_HOLDING_REGISTER 5245 1 °C 1 1 40 8 id:4046 MODBUS_HOLDING_REGISTER 5247 1 °C 1 0 40 4 id:4049 MODBUS_HOLDING_REGISTER 5249 1 4 0 1 0 @@ -510,7 +483,7 @@ id:4617 MODBUS_HOLDING_REGISTER 5257 1 1 0 1 0 Period time cooling MODBUS_HOLDING_REGISTER 736 1 min 4 0 180 30 Cooling delta temp. 20°C MODBUS_HOLDING_REGISTER 738 1 °C 1 3 10 3 Cooling delta temp. 40°C MODBUS_HOLDING_REGISTER 739 1 °C 1 3 20 6 -Operating mode charge pump climate system 1 MODBUS_HOLDING_REGISTER 748 1 4 0 1 1 +Operating mode charge pump (EB101) MODBUS_HOLDING_REGISTER 748 1 4 0 1 1 id:4660 MODBUS_HOLDING_REGISTER 5267 1 4 0 0 0 Shunted brine, accessory MODBUS_HOLDING_REGISTER 5268 1 4 0 1 0 Shunted brine max. temp. MODBUS_HOLDING_REGISTER 5271 1 °C 4 0 30 20 @@ -524,18 +497,19 @@ id:4707 MODBUS_HOLDING_REGISTER 5276 1 4 0 1 0 id:4708 MODBUS_HOLDING_REGISTER 5277 1 4 0 1 0 id:4709 MODBUS_HOLDING_REGISTER 5278 1 4 0 1 0 id:4710 MODBUS_HOLDING_REGISTER 5279 1 4 0 1 0 -Input AUX6 MODBUS_HOLDING_REGISTER 767 1 4 0 67 0 +Input AUX6 MODBUS_HOLDING_REGISTER 767 1 4 0 68 0 Operating mode circulation pump heating heat pump 1 MODBUS_HOLDING_REGISTER 783 1 4 0 1 1 Operating mode circulation pump hot water heat pump 1 MODBUS_HOLDING_REGISTER 799 1 4 0 1 1 -Speed circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 823 1 % 4 1 100 70 Operating mode circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 832 1 4 0 1 1 Speed circulation pump waiting mode heat pump 1 MODBUS_HOLDING_REGISTER 841 1 % 4 1 100 30 Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 1 100 30 Activated (Smart Price Adaption) MODBUS_HOLDING_REGISTER 843 1 4 0 1 0 +(SPA), heating activated (SPA) MODBUS_HOLDING_REGISTER 844 1 4 0 3 1 +(SPA), hot water activated MODBUS_HOLDING_REGISTER 846 1 4 0 3 1 (SPA), cooling activated MODBUS_HOLDING_REGISTER 849 1 4 0 1 1 -(SPA), area MODBUS_HOLDING_REGISTER 851 1 4 0 254 23 +(SPA), area MODBUS_HOLDING_REGISTER 851 1 4 0 255 255 Max. speed controlled charge pump (EB101) MODBUS_HOLDING_REGISTER 867 1 % 4 80 100 100 -Operating mode charge pump, cooling climate system 1 MODBUS_HOLDING_REGISTER 875 1 4 0 1 1 +Operating mode charge pump, cooling (EB101) MODBUS_HOLDING_REGISTER 875 1 4 0 1 1 External adjustment climate system 8 MODBUS_HOLDING_REGISTER 893 1 1 -10 10 0 External adjustment climate system 7 MODBUS_HOLDING_REGISTER 894 1 1 -10 10 0 External adjustment climate system 6 MODBUS_HOLDING_REGISTER 895 1 1 -10 10 0 @@ -609,7 +583,6 @@ Flow sensor activated X22 MODBUS_HOLDING_REGISTER 1049 1 4 0 1 0 Max. internal additional heat SG Ready MODBUS_HOLDING_REGISTER 1052 100 kW 2 0 900 900 Limit humidity in the room, cooling climate system 1 MODBUS_HOLDING_REGISTER 1063 1 1 0 1 0 Hysteresis (OPT) MODBUS_HOLDING_REGISTER 1066 1 2 10 2000 100 -Activated (EME10) MODBUS_HOLDING_REGISTER 1068 1 4 0 1 0 PV panel affects heating (EME) MODBUS_HOLDING_REGISTER 1069 1 4 0 1 0 PV panel affects hot water (EME) MODBUS_HOLDING_REGISTER 1070 1 4 0 1 0 Delay timer EME MODBUS_HOLDING_REGISTER 1071 1 5 0 0 0 @@ -667,7 +640,6 @@ Start day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTE End day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1281 1 4 1 31 31 Start month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1282 1 4 1 12 1 End month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1283 1 4 1 12 12 -Prioritise additional heat (AXC40) MODBUS_HOLDING_REGISTER 1320 1 4 0 1 0 Max difference, SES priority 1 energy source MODBUS_HOLDING_REGISTER 1326 10 °C 2 10 250 100 Max difference, SES lower priority energy source MODBUS_HOLDING_REGISTER 1327 10 °C 2 10 250 70 Installed (EB101) MODBUS_HOLDING_REGISTER 1550 1 4 0 1 1 @@ -723,6 +695,7 @@ Power at DOT, manual value MODBUS_HOLDING_REGISTER 4200 1 4 0 1 0 Blocking actions (ERS 3) MODBUS_HOLDING_REGISTER 4100 1 4 0 2 2 Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 4101 1 4 0 2 2 id:7048 MODBUS_HOLDING_REGISTER 5227 1 4 0 1 0 +id:7111 MODBUS_HOLDING_REGISTER 5233 1 Hz 4 25 120 120 id:7122 MODBUS_INPUT_REGISTER 2401 10 V 1 0 0 0 id:7123 MODBUS_INPUT_REGISTER 2402 10 V 1 0 0 0 id:7124 MODBUS_INPUT_REGISTER 2403 10 V 1 0 0 0 @@ -751,9 +724,10 @@ id:7943 MODBUS_INPUT_REGISTER 2399 10 % 5 0 0 0 id:7944 MODBUS_INPUT_REGISTER 2400 10 % 5 0 0 0 id:8002 MODBUS_HOLDING_REGISTER 1996 1 % 1 -15 10 -3 id:8003 MODBUS_HOLDING_REGISTER 1997 1 % 4 1 254 65 +Silent mode, max. frequency 2 (EB101) MODBUS_HOLDING_REGISTER 5343 1 Hz 4 25 120 120 Minimum permitted speed (EB101 GP12) MODBUS_HOLDING_REGISTER 5352 1 % 4 1 50 1 Start fan de-icing (EB101) MODBUS_HOLDING_REGISTER 5360 1 1 0 1 0 -id:8060 MODBUS_HOLDING_REGISTER 5368 1 1 0 1 0 +Defrost Requested EB101 MODBUS_HOLDING_REGISTER 5368 1 1 0 1 0 System 1 (RMU) MODBUS_HOLDING_REGISTER 176 1 4 0 1 0 System 2 (RMU) MODBUS_HOLDING_REGISTER 177 1 4 0 1 0 System 3 (RMU) MODBUS_HOLDING_REGISTER 178 1 4 0 1 0 @@ -773,7 +747,6 @@ Factor MODBUS_HOLDING_REGISTER 3033 1 4 1 10 5 id:10881 MODBUS_HOLDING_REGISTER 3062 1 4 0 1 0 id:10890 MODBUS_HOLDING_REGISTER 3063 1 4 0 1 0 Hot water start (BT5) MODBUS_INPUT_REGISTER 2014 10 °C 2 0 0 0 -Pump: Heating medium (GP6) MODBUS_INPUT_REGISTER 2128 1 4 0 0 0 id:12332 MODBUS_HOLDING_REGISTER 2767 1 2 -32768 32767 -32768 id:12333 MODBUS_HOLDING_REGISTER 2768 1 2 -32768 32767 -32768 id:12334 MODBUS_HOLDING_REGISTER 2769 1 2 -32768 32767 -32768 @@ -905,46 +878,46 @@ id:12709 MODBUS_HOLDING_REGISTER 3978 1 6 0 0 0 id:12710 MODBUS_HOLDING_REGISTER 3980 1 6 0 0 0 id:12711 MODBUS_HOLDING_REGISTER 3982 1 6 0 0 0 id:12712 MODBUS_HOLDING_REGISTER 3984 1 6 0 0 0 -id:12801 MODBUS_HOLDING_REGISTER 2505 10 °C 3 50 300 200 -id:12802 MODBUS_HOLDING_REGISTER 2507 10 °C 3 50 300 200 -id:12803 MODBUS_HOLDING_REGISTER 2509 10 °C 3 50 300 200 -id:12804 MODBUS_HOLDING_REGISTER 2511 10 °C 3 50 300 200 -id:12805 MODBUS_HOLDING_REGISTER 2513 10 °C 3 50 300 200 -id:12806 MODBUS_HOLDING_REGISTER 2515 10 °C 3 50 300 200 -id:12807 MODBUS_HOLDING_REGISTER 2517 10 °C 3 50 300 200 -id:12808 MODBUS_HOLDING_REGISTER 2519 10 °C 3 50 300 200 -id:12809 MODBUS_HOLDING_REGISTER 2521 10 °C 3 50 300 200 -id:12810 MODBUS_HOLDING_REGISTER 2523 10 °C 3 50 300 200 -id:12811 MODBUS_HOLDING_REGISTER 2525 10 °C 3 50 300 200 -id:12812 MODBUS_HOLDING_REGISTER 2527 10 °C 3 50 300 200 -id:12813 MODBUS_HOLDING_REGISTER 2529 10 °C 3 50 300 200 -id:12814 MODBUS_HOLDING_REGISTER 2531 10 °C 3 50 300 200 -id:12815 MODBUS_HOLDING_REGISTER 2533 10 °C 3 50 300 200 -id:12816 MODBUS_HOLDING_REGISTER 2535 10 °C 3 50 300 200 -id:12817 MODBUS_HOLDING_REGISTER 2537 10 °C 3 50 300 200 -id:12818 MODBUS_HOLDING_REGISTER 2539 10 °C 3 50 300 200 -id:12819 MODBUS_HOLDING_REGISTER 2541 10 °C 3 50 300 200 -id:12820 MODBUS_HOLDING_REGISTER 2543 10 °C 3 50 300 200 -id:12821 MODBUS_HOLDING_REGISTER 2545 10 °C 3 50 300 200 -id:12822 MODBUS_HOLDING_REGISTER 2547 10 °C 3 50 300 200 -id:12823 MODBUS_HOLDING_REGISTER 2549 10 °C 3 50 300 200 -id:12824 MODBUS_HOLDING_REGISTER 2551 10 °C 3 50 300 200 -id:12825 MODBUS_HOLDING_REGISTER 2553 10 °C 3 50 300 200 -id:12826 MODBUS_HOLDING_REGISTER 2555 10 °C 3 50 300 200 -id:12827 MODBUS_HOLDING_REGISTER 2557 10 °C 3 50 300 200 -id:12828 MODBUS_HOLDING_REGISTER 2559 10 °C 3 50 300 200 -id:12829 MODBUS_HOLDING_REGISTER 2561 10 °C 3 50 300 200 -id:12830 MODBUS_HOLDING_REGISTER 2563 10 °C 3 50 300 200 -id:12831 MODBUS_HOLDING_REGISTER 2565 10 °C 3 50 300 200 -id:12832 MODBUS_HOLDING_REGISTER 2567 10 °C 3 50 300 200 -id:12833 MODBUS_HOLDING_REGISTER 2569 10 °C 3 50 300 200 -id:12834 MODBUS_HOLDING_REGISTER 2571 10 °C 3 50 300 200 -id:12835 MODBUS_HOLDING_REGISTER 2573 10 °C 3 50 300 200 -id:12836 MODBUS_HOLDING_REGISTER 2575 10 °C 3 50 300 200 -id:12837 MODBUS_HOLDING_REGISTER 2577 10 °C 3 50 300 200 -id:12838 MODBUS_HOLDING_REGISTER 2579 10 °C 3 50 300 200 -id:12839 MODBUS_HOLDING_REGISTER 2581 10 °C 3 50 300 200 -id:12840 MODBUS_HOLDING_REGISTER 2583 10 °C 3 50 300 200 +id:12801 MODBUS_HOLDING_REGISTER 2505 10 °C 3 50 350 200 +id:12802 MODBUS_HOLDING_REGISTER 2507 10 °C 3 50 350 200 +id:12803 MODBUS_HOLDING_REGISTER 2509 10 °C 3 50 350 200 +id:12804 MODBUS_HOLDING_REGISTER 2511 10 °C 3 50 350 200 +id:12805 MODBUS_HOLDING_REGISTER 2513 10 °C 3 50 350 200 +id:12806 MODBUS_HOLDING_REGISTER 2515 10 °C 3 50 350 200 +id:12807 MODBUS_HOLDING_REGISTER 2517 10 °C 3 50 350 200 +id:12808 MODBUS_HOLDING_REGISTER 2519 10 °C 3 50 350 200 +id:12809 MODBUS_HOLDING_REGISTER 2521 10 °C 3 50 350 200 +id:12810 MODBUS_HOLDING_REGISTER 2523 10 °C 3 50 350 200 +id:12811 MODBUS_HOLDING_REGISTER 2525 10 °C 3 50 350 200 +id:12812 MODBUS_HOLDING_REGISTER 2527 10 °C 3 50 350 200 +id:12813 MODBUS_HOLDING_REGISTER 2529 10 °C 3 50 350 200 +id:12814 MODBUS_HOLDING_REGISTER 2531 10 °C 3 50 350 200 +id:12815 MODBUS_HOLDING_REGISTER 2533 10 °C 3 50 350 200 +id:12816 MODBUS_HOLDING_REGISTER 2535 10 °C 3 50 350 200 +id:12817 MODBUS_HOLDING_REGISTER 2537 10 °C 3 50 350 200 +id:12818 MODBUS_HOLDING_REGISTER 2539 10 °C 3 50 350 200 +id:12819 MODBUS_HOLDING_REGISTER 2541 10 °C 3 50 350 200 +id:12820 MODBUS_HOLDING_REGISTER 2543 10 °C 3 50 350 200 +id:12821 MODBUS_HOLDING_REGISTER 2545 10 °C 3 50 350 200 +id:12822 MODBUS_HOLDING_REGISTER 2547 10 °C 3 50 350 200 +id:12823 MODBUS_HOLDING_REGISTER 2549 10 °C 3 50 350 200 +id:12824 MODBUS_HOLDING_REGISTER 2551 10 °C 3 50 350 200 +id:12825 MODBUS_HOLDING_REGISTER 2553 10 °C 3 50 350 200 +id:12826 MODBUS_HOLDING_REGISTER 2555 10 °C 3 50 350 200 +id:12827 MODBUS_HOLDING_REGISTER 2557 10 °C 3 50 350 200 +id:12828 MODBUS_HOLDING_REGISTER 2559 10 °C 3 50 350 200 +id:12829 MODBUS_HOLDING_REGISTER 2561 10 °C 3 50 350 200 +id:12830 MODBUS_HOLDING_REGISTER 2563 10 °C 3 50 350 200 +id:12831 MODBUS_HOLDING_REGISTER 2565 10 °C 3 50 350 200 +id:12832 MODBUS_HOLDING_REGISTER 2567 10 °C 3 50 350 200 +id:12833 MODBUS_HOLDING_REGISTER 2569 10 °C 3 50 350 200 +id:12834 MODBUS_HOLDING_REGISTER 2571 10 °C 3 50 350 200 +id:12835 MODBUS_HOLDING_REGISTER 2573 10 °C 3 50 350 200 +id:12836 MODBUS_HOLDING_REGISTER 2575 10 °C 3 50 350 200 +id:12837 MODBUS_HOLDING_REGISTER 2577 10 °C 3 50 350 200 +id:12838 MODBUS_HOLDING_REGISTER 2579 10 °C 3 50 350 200 +id:12839 MODBUS_HOLDING_REGISTER 2581 10 °C 3 50 350 200 +id:12840 MODBUS_HOLDING_REGISTER 2583 10 °C 3 50 350 200 id:12841 MODBUS_HOLDING_REGISTER 2585 10 °C 3 50 350 250 id:12842 MODBUS_HOLDING_REGISTER 2587 10 °C 3 50 350 250 id:12843 MODBUS_HOLDING_REGISTER 2589 10 °C 3 50 350 250 @@ -1095,7 +1068,7 @@ Time between filter replacement MODBUS_HOLDING_REGISTER 2728 1 4 1 24 3 Time between filter replacement MODBUS_HOLDING_REGISTER 2729 1 4 1 24 3 Time between filter replacement MODBUS_HOLDING_REGISTER 2730 1 4 1 24 3 Time between filter replacement MODBUS_HOLDING_REGISTER 2731 1 4 1 24 3 -AUX from Modbus MODBUS_HOLDING_REGISTER 2740 1 4 0 67 0 +AUX from Modbus MODBUS_HOLDING_REGISTER 2740 1 4 0 68 0 AUX from Modbus MODBUS_HOLDING_REGISTER 2741 1 2 0 0 0 Heat pump test - Silent mode (EB101/EB102) MODBUS_HOLDING_REGISTER 5101 1 4 0 1 0 Last defrost, heat pump 1 MODBUS_INPUT_REGISTER 2158 1 4 0 255 255 @@ -1133,7 +1106,7 @@ Fan mode 7 MODBUS_INPUT_REGISTER 2170 1 % 4 0 0 0 Fan mode 8 MODBUS_INPUT_REGISTER 2171 1 % 4 0 0 0 Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 5392 1 4 0 1 0 Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 5025 1 4 0 1 0 -id:24483 MODBUS_HOLDING_REGISTER 5008 1 4 0 1 0 +Modbus external control MODBUS_HOLDING_REGISTER 5008 1 4 0 1 0 id:24484 MODBUS_HOLDING_REGISTER 5009 10 °C 2 50 800 450 id:24485 MODBUS_HOLDING_REGISTER 5010 10 °C 2 50 800 450 id:24486 MODBUS_HOLDING_REGISTER 5011 10 °C 2 50 800 450 @@ -1256,20 +1229,214 @@ id:27818 MODBUS_HOLDING_REGISTER 5459 1 4 0 1 0 id:27819 MODBUS_HOLDING_REGISTER 5460 1 4 0 1 0 id:27854 MODBUS_HOLDING_REGISTER 5078 1 4 0 1 0 id:27855 MODBUS_HOLDING_REGISTER 5079 1 4 0 100 0 -id:28034 MODBUS_INPUT_REGISTER 5461 10 °C 2 0 0 0 -id:28035 MODBUS_INPUT_REGISTER 5462 10 °C 2 0 0 0 -id:28036 MODBUS_INPUT_REGISTER 5463 10 °C 2 0 0 0 -id:28037 MODBUS_INPUT_REGISTER 5464 10 °C 2 0 0 0 -id:28038 MODBUS_INPUT_REGISTER 5465 10 °C 2 0 0 0 -id:28039 MODBUS_INPUT_REGISTER 5466 10 °C 2 0 0 0 -id:28040 MODBUS_INPUT_REGISTER 5467 10 °C 2 0 0 0 -id:28041 MODBUS_INPUT_REGISTER 5468 10 °C 2 0 0 0 -id:28042 MODBUS_INPUT_REGISTER 5469 10 °C 2 0 0 0 -Temperature: HTS 1 MODBUS_INPUT_REGISTER 2800 10 °C 3 0 0 0 -Humidity: HTS 1 MODBUS_INPUT_REGISTER 3130 10 %RH 3 0 0 0 -Input AUX7 MODBUS_HOLDING_REGISTER 1555 1 4 0 67 0 -Input AUX8 MODBUS_HOLDING_REGISTER 1556 1 4 0 67 0 -Input AUX9 MODBUS_HOLDING_REGISTER 1557 1 4 0 67 0 +id:28034 MODBUS_INPUT_REGISTER 2445 10 °C 2 0 0 0 +id:28035 MODBUS_INPUT_REGISTER 2446 10 °C 2 0 0 0 +id:28036 MODBUS_INPUT_REGISTER 2447 10 °C 2 0 0 0 +id:28037 MODBUS_INPUT_REGISTER 2448 10 °C 2 0 0 0 +id:28038 MODBUS_INPUT_REGISTER 2449 10 °C 2 0 0 0 +id:28039 MODBUS_INPUT_REGISTER 2450 10 °C 2 0 0 0 +id:28040 MODBUS_INPUT_REGISTER 2451 10 °C 2 0 0 0 +id:28041 MODBUS_INPUT_REGISTER 2452 10 °C 2 0 0 0 +id:28042 MODBUS_INPUT_REGISTER 2453 10 °C 2 0 0 0 +Boiler temperature (BT52) MODBUS_INPUT_REGISTER 3800 10 °C 2 0 0 0 +id:28403 MODBUS_HOLDING_REGISTER 5600 1 3 -1000000 1000000 100 +id:28404 MODBUS_HOLDING_REGISTER 5602 1 3 -1000000 1000000 100 +id:28405 MODBUS_HOLDING_REGISTER 5604 1 3 -1000000 1000000 100 +id:28406 MODBUS_HOLDING_REGISTER 5606 1 3 -1000000 1000000 100 +id:28407 MODBUS_HOLDING_REGISTER 5608 1 3 -1000000 1000000 100 +id:28408 MODBUS_HOLDING_REGISTER 5610 1 3 -1000000 1000000 100 +id:28409 MODBUS_HOLDING_REGISTER 5612 1 3 -1000000 1000000 100 +id:28410 MODBUS_HOLDING_REGISTER 5614 1 3 -1000000 1000000 100 +id:28411 MODBUS_HOLDING_REGISTER 5616 1 3 -1000000 1000000 100 +id:28412 MODBUS_HOLDING_REGISTER 5618 1 3 -1000000 1000000 100 +id:28413 MODBUS_HOLDING_REGISTER 5620 1 3 -1000000 1000000 100 +id:28414 MODBUS_HOLDING_REGISTER 5622 1 3 -1000000 1000000 100 +id:28415 MODBUS_HOLDING_REGISTER 5624 1 3 -1000000 1000000 100 +id:28416 MODBUS_HOLDING_REGISTER 5626 1 3 -1000000 1000000 100 +id:28417 MODBUS_HOLDING_REGISTER 5628 1 3 -1000000 1000000 100 +id:28418 MODBUS_HOLDING_REGISTER 5630 1 3 -1000000 1000000 100 +id:28419 MODBUS_HOLDING_REGISTER 5632 1 3 -1000000 1000000 100 +id:28420 MODBUS_HOLDING_REGISTER 5634 1 3 -1000000 1000000 100 +id:28421 MODBUS_HOLDING_REGISTER 5636 1 3 -1000000 1000000 100 +id:28422 MODBUS_HOLDING_REGISTER 5638 1 3 -1000000 1000000 100 +id:28423 MODBUS_HOLDING_REGISTER 5640 1 3 -1000000 1000000 100 +id:28424 MODBUS_HOLDING_REGISTER 5642 1 3 -1000000 1000000 100 +id:28425 MODBUS_HOLDING_REGISTER 5644 1 3 -1000000 1000000 100 +id:28426 MODBUS_HOLDING_REGISTER 5646 1 3 -1000000 1000000 100 +id:28427 MODBUS_HOLDING_REGISTER 5648 1 3 -1000000 1000000 100 +id:28428 MODBUS_HOLDING_REGISTER 5650 1 3 -1000000 1000000 100 +id:28429 MODBUS_HOLDING_REGISTER 5652 1 3 -1000000 1000000 100 +id:28430 MODBUS_HOLDING_REGISTER 5654 1 3 -1000000 1000000 100 +id:28431 MODBUS_HOLDING_REGISTER 5656 1 3 -1000000 1000000 100 +id:28432 MODBUS_HOLDING_REGISTER 5658 1 3 -1000000 1000000 100 +id:28433 MODBUS_HOLDING_REGISTER 5660 1 3 -1000000 1000000 100 +id:28434 MODBUS_HOLDING_REGISTER 5662 1 3 -1000000 1000000 100 +id:28435 MODBUS_HOLDING_REGISTER 5664 1 3 -1000000 1000000 100 +id:28436 MODBUS_HOLDING_REGISTER 5666 1 3 -1000000 1000000 100 +id:28437 MODBUS_HOLDING_REGISTER 5668 1 3 -1000000 1000000 100 +id:28438 MODBUS_HOLDING_REGISTER 5670 1 3 -1000000 1000000 100 +id:28439 MODBUS_HOLDING_REGISTER 5672 1 3 -1000000 1000000 100 +id:28440 MODBUS_HOLDING_REGISTER 5674 1 3 -1000000 1000000 100 +id:28441 MODBUS_HOLDING_REGISTER 5676 1 3 -1000000 1000000 100 +id:28442 MODBUS_HOLDING_REGISTER 5678 1 3 -1000000 1000000 100 +id:28443 MODBUS_HOLDING_REGISTER 5680 1 3 -1000000 1000000 100 +id:28444 MODBUS_HOLDING_REGISTER 5682 1 3 -1000000 1000000 100 +id:28445 MODBUS_HOLDING_REGISTER 5684 1 3 -1000000 1000000 100 +id:28446 MODBUS_HOLDING_REGISTER 5686 1 3 -1000000 1000000 100 +id:28447 MODBUS_HOLDING_REGISTER 5688 1 3 -1000000 1000000 100 +id:28448 MODBUS_HOLDING_REGISTER 5690 1 3 -1000000 1000000 100 +id:28449 MODBUS_HOLDING_REGISTER 5692 1 3 -1000000 1000000 100 +id:28450 MODBUS_HOLDING_REGISTER 5694 1 3 -1000000 1000000 100 +id:28451 MODBUS_HOLDING_REGISTER 5696 1 3 -1000000 1000000 100 +id:28452 MODBUS_HOLDING_REGISTER 5698 1 3 -1000000 1000000 100 +id:28453 MODBUS_HOLDING_REGISTER 5700 1 3 -1000000 1000000 100 +id:28454 MODBUS_HOLDING_REGISTER 5702 1 3 -1000000 1000000 100 +id:28455 MODBUS_HOLDING_REGISTER 5704 1 3 -1000000 1000000 100 +id:28456 MODBUS_HOLDING_REGISTER 5706 1 3 -1000000 1000000 100 +id:28457 MODBUS_HOLDING_REGISTER 5708 1 3 -1000000 1000000 100 +id:28458 MODBUS_HOLDING_REGISTER 5710 1 3 -1000000 1000000 100 +id:28459 MODBUS_HOLDING_REGISTER 5712 1 3 -1000000 1000000 100 +id:28460 MODBUS_HOLDING_REGISTER 5714 1 3 -1000000 1000000 100 +id:28461 MODBUS_HOLDING_REGISTER 5716 1 3 -1000000 1000000 100 +id:28462 MODBUS_HOLDING_REGISTER 5718 1 3 -1000000 1000000 100 +id:28463 MODBUS_HOLDING_REGISTER 5720 1 3 -1000000 1000000 100 +id:28464 MODBUS_HOLDING_REGISTER 5722 1 3 -1000000 1000000 100 +id:28465 MODBUS_HOLDING_REGISTER 5724 1 3 -1000000 1000000 100 +id:28466 MODBUS_HOLDING_REGISTER 5726 1 3 -1000000 1000000 100 +id:28467 MODBUS_HOLDING_REGISTER 5728 1 3 -1000000 1000000 100 +id:28468 MODBUS_HOLDING_REGISTER 5730 1 3 -1000000 1000000 100 +id:28469 MODBUS_HOLDING_REGISTER 5732 1 3 -1000000 1000000 100 +id:28470 MODBUS_HOLDING_REGISTER 5734 1 3 -1000000 1000000 100 +id:28471 MODBUS_HOLDING_REGISTER 5736 1 3 -1000000 1000000 100 +id:28472 MODBUS_HOLDING_REGISTER 5738 1 3 -1000000 1000000 100 +id:28473 MODBUS_HOLDING_REGISTER 5740 1 3 -1000000 1000000 100 +id:28474 MODBUS_HOLDING_REGISTER 5742 1 3 -1000000 1000000 100 +id:28475 MODBUS_HOLDING_REGISTER 5744 1 3 -1000000 1000000 100 +id:28476 MODBUS_HOLDING_REGISTER 5746 1 3 -1000000 1000000 100 +id:28477 MODBUS_HOLDING_REGISTER 5748 1 3 -1000000 1000000 100 +id:28478 MODBUS_HOLDING_REGISTER 5750 1 3 -1000000 1000000 100 +id:28479 MODBUS_HOLDING_REGISTER 5752 1 3 -1000000 1000000 100 +id:28480 MODBUS_HOLDING_REGISTER 5754 1 3 -1000000 1000000 100 +id:28481 MODBUS_HOLDING_REGISTER 5756 1 3 -1000000 1000000 100 +id:28482 MODBUS_HOLDING_REGISTER 5758 1 3 -1000000 1000000 100 +id:28483 MODBUS_HOLDING_REGISTER 5760 1 3 -1000000 1000000 100 +id:28484 MODBUS_HOLDING_REGISTER 5762 1 3 -1000000 1000000 100 +id:28485 MODBUS_HOLDING_REGISTER 5764 1 3 -1000000 1000000 100 +id:28486 MODBUS_HOLDING_REGISTER 5766 1 3 -1000000 1000000 100 +id:28487 MODBUS_HOLDING_REGISTER 5768 1 3 -1000000 1000000 100 +id:28488 MODBUS_HOLDING_REGISTER 5770 1 3 -1000000 1000000 100 +id:28489 MODBUS_HOLDING_REGISTER 5772 1 3 -1000000 1000000 100 +id:28490 MODBUS_HOLDING_REGISTER 5774 1 3 -1000000 1000000 100 +id:28491 MODBUS_HOLDING_REGISTER 5776 1 3 -1000000 1000000 100 +id:28492 MODBUS_HOLDING_REGISTER 5778 1 3 -1000000 1000000 100 +id:28493 MODBUS_HOLDING_REGISTER 5780 1 3 -1000000 1000000 100 +id:28494 MODBUS_HOLDING_REGISTER 5782 1 3 -1000000 1000000 100 +id:28495 MODBUS_HOLDING_REGISTER 5784 1 3 -1000000 1000000 100 +id:28496 MODBUS_HOLDING_REGISTER 5786 1 3 -1000000 1000000 100 +id:28497 MODBUS_HOLDING_REGISTER 5788 1 3 -1000000 1000000 100 +id:28498 MODBUS_HOLDING_REGISTER 5790 1 3 -1000000 1000000 100 +id:28500 MODBUS_HOLDING_REGISTER 5792 1 3 -1000000 1000000 100 +id:28501 MODBUS_HOLDING_REGISTER 5794 1 3 -1000000 1000000 100 +id:28502 MODBUS_HOLDING_REGISTER 5796 1 3 -1000000 1000000 100 +id:28503 MODBUS_HOLDING_REGISTER 5798 1 3 -1000000 1000000 100 +id:28504 MODBUS_HOLDING_REGISTER 5800 1 3 -1000000 1000000 100 +id:28505 MODBUS_HOLDING_REGISTER 5802 1 3 -1000000 1000000 100 +id:28506 MODBUS_HOLDING_REGISTER 5804 1 3 -1000000 1000000 100 +id:28507 MODBUS_HOLDING_REGISTER 5806 1 3 -1000000 1000000 100 +id:28508 MODBUS_HOLDING_REGISTER 5808 1 3 -1000000 1000000 100 +id:28509 MODBUS_HOLDING_REGISTER 5810 1 3 -1000000 1000000 100 +id:28510 MODBUS_HOLDING_REGISTER 5812 1 3 -1000000 1000000 100 +id:28511 MODBUS_HOLDING_REGISTER 5814 1 3 -1000000 1000000 100 +id:28512 MODBUS_HOLDING_REGISTER 5816 1 3 -1000000 1000000 100 +id:28513 MODBUS_HOLDING_REGISTER 5818 1 3 -1000000 1000000 100 +id:28514 MODBUS_HOLDING_REGISTER 5820 1 3 -1000000 1000000 100 +id:28515 MODBUS_HOLDING_REGISTER 5822 1 3 -1000000 1000000 100 +id:28516 MODBUS_HOLDING_REGISTER 5824 1 3 -1000000 1000000 100 +id:28517 MODBUS_HOLDING_REGISTER 5826 1 3 -1000000 1000000 100 +id:28518 MODBUS_HOLDING_REGISTER 5828 1 3 -1000000 1000000 100 +id:28519 MODBUS_HOLDING_REGISTER 5830 1 3 -1000000 1000000 100 +id:28520 MODBUS_HOLDING_REGISTER 5832 1 3 -1000000 1000000 100 +id:28521 MODBUS_HOLDING_REGISTER 5834 1 3 -1000000 1000000 100 +id:28522 MODBUS_HOLDING_REGISTER 5836 1 3 -1000000 1000000 100 +id:28523 MODBUS_HOLDING_REGISTER 5838 1 3 -1000000 1000000 100 +id:28524 MODBUS_HOLDING_REGISTER 5840 1 3 -1000000 1000000 100 +id:28525 MODBUS_HOLDING_REGISTER 5842 1 3 -1000000 1000000 100 +id:28526 MODBUS_HOLDING_REGISTER 5844 1 3 -1000000 1000000 100 +id:28527 MODBUS_HOLDING_REGISTER 5846 1 3 -1000000 1000000 100 +id:28528 MODBUS_HOLDING_REGISTER 5848 1 3 -1000000 1000000 100 +id:28529 MODBUS_HOLDING_REGISTER 5850 1 3 -1000000 1000000 100 +id:28530 MODBUS_HOLDING_REGISTER 5852 1 3 -1000000 1000000 100 +id:28531 MODBUS_HOLDING_REGISTER 5854 1 3 -1000000 1000000 100 +id:28532 MODBUS_HOLDING_REGISTER 5856 1 3 -1000000 1000000 100 +id:28533 MODBUS_HOLDING_REGISTER 5858 1 3 -1000000 1000000 100 +id:28534 MODBUS_HOLDING_REGISTER 5860 1 3 -1000000 1000000 100 +id:28535 MODBUS_HOLDING_REGISTER 5862 1 3 -1000000 1000000 100 +id:28536 MODBUS_HOLDING_REGISTER 5864 1 3 -1000000 1000000 100 +id:28537 MODBUS_HOLDING_REGISTER 5866 1 3 -1000000 1000000 100 +id:28538 MODBUS_HOLDING_REGISTER 5868 1 3 -1000000 1000000 100 +id:28539 MODBUS_HOLDING_REGISTER 5870 1 3 -1000000 1000000 100 +id:28540 MODBUS_HOLDING_REGISTER 5872 1 3 -1000000 1000000 100 +id:28541 MODBUS_HOLDING_REGISTER 5874 1 3 -1000000 1000000 100 +id:28542 MODBUS_HOLDING_REGISTER 5876 1 3 -1000000 1000000 100 +id:28543 MODBUS_HOLDING_REGISTER 5878 1 3 -1000000 1000000 100 +id:28544 MODBUS_HOLDING_REGISTER 5880 1 3 -1000000 1000000 100 +id:28545 MODBUS_HOLDING_REGISTER 5882 1 3 -1000000 1000000 100 +id:28546 MODBUS_HOLDING_REGISTER 5884 1 3 -1000000 1000000 100 +id:28547 MODBUS_HOLDING_REGISTER 5886 1 3 -1000000 1000000 100 +id:28548 MODBUS_HOLDING_REGISTER 5888 1 3 -1000000 1000000 100 +id:28549 MODBUS_HOLDING_REGISTER 5890 1 3 -1000000 1000000 100 +id:28550 MODBUS_HOLDING_REGISTER 5892 1 3 -1000000 1000000 100 +id:28551 MODBUS_HOLDING_REGISTER 5894 1 3 -1000000 1000000 100 +id:28552 MODBUS_HOLDING_REGISTER 5896 1 3 -1000000 1000000 100 +id:28553 MODBUS_HOLDING_REGISTER 5898 1 3 -1000000 1000000 100 +id:28554 MODBUS_HOLDING_REGISTER 5900 1 3 -1000000 1000000 100 +id:28555 MODBUS_HOLDING_REGISTER 5902 1 3 -1000000 1000000 100 +id:28556 MODBUS_HOLDING_REGISTER 5904 1 3 -1000000 1000000 100 +id:28557 MODBUS_HOLDING_REGISTER 5906 1 3 -1000000 1000000 100 +id:28558 MODBUS_HOLDING_REGISTER 5908 1 3 -1000000 1000000 100 +id:28559 MODBUS_HOLDING_REGISTER 5910 1 3 -1000000 1000000 100 +id:28560 MODBUS_HOLDING_REGISTER 5912 1 3 -1000000 1000000 100 +id:28561 MODBUS_HOLDING_REGISTER 5914 1 3 -1000000 1000000 100 +id:28562 MODBUS_HOLDING_REGISTER 5916 1 3 -1000000 1000000 100 +id:28563 MODBUS_HOLDING_REGISTER 5918 1 3 -1000000 1000000 100 +id:28564 MODBUS_HOLDING_REGISTER 5920 1 3 -1000000 1000000 100 +id:28565 MODBUS_HOLDING_REGISTER 5922 1 3 -1000000 1000000 100 +id:28566 MODBUS_HOLDING_REGISTER 5924 1 3 -1000000 1000000 100 +id:28567 MODBUS_HOLDING_REGISTER 5926 1 3 -1000000 1000000 100 +id:28568 MODBUS_HOLDING_REGISTER 5928 1 3 -1000000 1000000 100 +id:28569 MODBUS_HOLDING_REGISTER 5930 1 3 -1000000 1000000 100 +id:28570 MODBUS_HOLDING_REGISTER 5932 1 3 -1000000 1000000 100 +id:28571 MODBUS_HOLDING_REGISTER 5934 1 3 -1000000 1000000 100 +id:28572 MODBUS_HOLDING_REGISTER 5936 1 3 -1000000 1000000 100 +id:28573 MODBUS_HOLDING_REGISTER 5938 1 3 -1000000 1000000 100 +id:28574 MODBUS_HOLDING_REGISTER 5940 1 3 -1000000 1000000 100 +id:28575 MODBUS_HOLDING_REGISTER 5942 1 3 -1000000 1000000 100 +id:28576 MODBUS_HOLDING_REGISTER 5944 1 3 -1000000 1000000 100 +id:28577 MODBUS_HOLDING_REGISTER 5946 1 3 -1000000 1000000 100 +id:28578 MODBUS_HOLDING_REGISTER 5948 1 3 -1000000 1000000 100 +id:28579 MODBUS_HOLDING_REGISTER 5950 1 3 -1000000 1000000 100 +id:28580 MODBUS_HOLDING_REGISTER 5952 1 3 -1000000 1000000 100 +id:28581 MODBUS_HOLDING_REGISTER 5954 1 3 -1000000 1000000 100 +id:28582 MODBUS_HOLDING_REGISTER 5956 1 3 -1000000 1000000 100 +id:28583 MODBUS_HOLDING_REGISTER 5958 1 3 -1000000 1000000 100 +id:28584 MODBUS_HOLDING_REGISTER 5960 1 3 -1000000 1000000 100 +id:28585 MODBUS_HOLDING_REGISTER 5962 1 3 -1000000 1000000 100 +id:28586 MODBUS_HOLDING_REGISTER 5964 1 3 -1000000 1000000 100 +id:28587 MODBUS_HOLDING_REGISTER 5966 1 3 -1000000 1000000 100 +id:28588 MODBUS_HOLDING_REGISTER 5968 1 3 -1000000 1000000 100 +id:28589 MODBUS_HOLDING_REGISTER 5970 1 3 -1000000 1000000 100 +id:28590 MODBUS_HOLDING_REGISTER 5972 1 3 -1000000 1000000 100 +id:28591 MODBUS_HOLDING_REGISTER 5974 1 3 -1000000 1000000 100 +id:28592 MODBUS_HOLDING_REGISTER 5976 1 3 -1000000 1000000 100 +id:28593 MODBUS_HOLDING_REGISTER 5978 1 3 -1000000 1000000 100 +id:28594 MODBUS_HOLDING_REGISTER 5980 1 3 -1000000 1000000 100 +id:28595 MODBUS_HOLDING_REGISTER 5982 1 3 -1000000 1000000 100 +id:29258 MODBUS_HOLDING_REGISTER 5984 1 kW 5 0 65535 0 +Temperature: RMU S40 MODBUS_INPUT_REGISTER 2800 10 °C 3 0 0 0 +Humidity: RMU S40 MODBUS_INPUT_REGISTER 3130 10 %RH 3 0 0 0 +Input AUX7 MODBUS_HOLDING_REGISTER 1555 1 4 0 68 0 +Input AUX8 MODBUS_HOLDING_REGISTER 1556 1 4 0 68 0 +Input AUX9 MODBUS_HOLDING_REGISTER 1557 1 4 0 68 0 id:55076 MODBUS_HOLDING_REGISTER 2877 1 4 0 1 0 id:55077 MODBUS_HOLDING_REGISTER 2878 1 4 0 1 0 id:55078 MODBUS_HOLDING_REGISTER 2879 1 4 0 1 0 @@ -1280,7 +1447,7 @@ id:55082 MODBUS_HOLDING_REGISTER 2883 1 4 0 1 0 id:55083 MODBUS_HOLDING_REGISTER 2884 1 4 0 1 0 Immersion heater power, emergency mode MODBUS_HOLDING_REGISTER 3028 100 kW 2 0 4500 600 Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 3986 1 4 0 1 0 -Return line (AZ2-BT69) MODBUS_INPUT_REGISTER 2190 10 °C 2 0 0 0 -Supply line (AZ2-BT68) MODBUS_INPUT_REGISTER 2191 10 °C 2 0 0 0 "EEV Control Mode (EB101)" MODBUS_INPUT_REGISTER 2413 1 4 0 0 0 "EEV State (EB101)" MODBUS_INPUT_REGISTER 2421 1 4 0 0 0 +id:55495 MODBUS_HOLDING_REGISTER 5550 1 4 0 1 0 +id:55496 MODBUS_HOLDING_REGISTER 5207 10 °C 2 0 0 0 diff --git a/nibe/data/s2125.json b/nibe/data/s2125.json index d700a8c..0f50c2a 100644 --- a/nibe/data/s2125.json +++ b/nibe/data/s2125.json @@ -55,13 +55,6 @@ "size": "s16", "name": "hot-water-charging-bt6-30010" }, - "30027": { - "title": "Roomsensor 1-1", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "roomsensor-1-1-30027" - }, "30037": { "title": "Temperature limiter (EB100-FD1)", "factor": 1, @@ -95,13 +88,6 @@ "size": "s16", "name": "electrical-anode-eb100-fr1-30042" }, - "30047": { - "title": "Current (BE3)", - "factor": 10, - "unit": "A", - "size": "u32", - "name": "current-be3-30047" - }, "30073": { "title": "Additional heat (BT63)", "factor": 10, @@ -320,18 +306,6 @@ "size": "u16", "name": "max-compressor-frequency-heating-30142" }, - "30143": { - "title": "Inverter alarm code", - "factor": 1, - "size": "u16", - "name": "inverter-alarm-code-30143" - }, - "30144": { - "title": "Inverter alarm code", - "factor": 1, - "size": "u16", - "name": "inverter-alarm-code-30144" - }, "30152": { "title": "External adjustment climate system 8", "factor": 1, @@ -504,117 +478,6 @@ "size": "u8", "name": "available-compressors-cooling-30322" }, - "30328": { - "title": "+Adjust, port", - "factor": 1, - "size": "u8", - "name": "adjust-port-30328" - }, - "30329": { - "title": "+Adjust, operating mode", - "factor": 1, - "size": "u8", - "name": "adjust-operating-mode-30329" - }, - "30330": { - "title": "+Adjust, comfort", - "factor": 1, - "size": "u8", - "name": "adjust-comfort-30330" - }, - "30331": { - "title": "+Adjust, parallel adjustment", - "factor": 1, - "size": "s8", - "name": "adjust-parallel-adjustment-30331" - }, - "30332": { - "title": "+Adjust, humidity", - "factor": 10, - "unit": "%RH", - "size": "s16", - "name": "adjust-humidity-30332" - }, - "30333": { - "title": "+Adjust, indoor temperature", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "adjust-indoor-temperature-30333" - }, - "30334": { - "title": "+Adjust, outdoor temperature", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "adjust-outdoor-temperature-30334" - }, - "30335": { - "title": "+Adjust, version", - "factor": 1, - "size": "u16", - "name": "adjust-version-30335" - }, - "30336": { - "title": "+Adjust, active", - "factor": 1, - "size": "u8", - "name": "adjust-active-30336" - }, - "30337": { - "title": "+Adjust, demand", - "factor": 1, - "size": "u8", - "name": "adjust-demand-30337" - }, - "40002": { - "title": "+Adjust, parallel factor", - "factor": 1, - "size": "s8", - "min": 1.0, - "max": 10.0, - "default": 5.0, - "name": "adjust-parallel-factor-40002", - "write": true - }, - "40003": { - "title": "+Adjust, Parallel (min-max)", - "factor": 1, - "size": "s8", - "min": 1.0, - "max": 100.0, - "default": 100.0, - "name": "adjust-parallel-min-max-40003", - "write": true - }, - "30324": { - "title": "Humidity (BM1)", - "factor": 10, - "unit": "%", - "size": "s16", - "name": "humidity-bm1-30324" - }, - "30325": { - "title": "Temperature (BM1)", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "temperature-bm1-30325" - }, - "30326": { - "title": "Pressure (BM1)", - "factor": 10, - "unit": "kPa", - "size": "s16", - "name": "pressure-bm1-30326" - }, - "30327": { - "title": "Dew point (BM1)", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "dew-point-bm1-30327" - }, "30338": { "title": "Supply temperature (BT64)", "factor": 10, @@ -664,25 +527,6 @@ "size": "u8", "name": "status-compressor-demand-s135-30351" }, - "30352": { - "title": "No. of starts (S135)", - "factor": 1, - "size": "u32", - "min": 0.0, - "max": 9999999.0, - "default": 0.0, - "name": "no-of-starts-s135-30352" - }, - "30354": { - "title": "Operating time (S135)", - "factor": 1, - "unit": "h", - "size": "u32", - "min": 0.0, - "max": 9999999.0, - "default": 0.0, - "name": "operating-time-s135-30354" - }, "40012": { "title": "Degree minutes", "factor": 10, @@ -863,11 +707,11 @@ "name": "min-compressor-speed-eb101-30406" }, "30407": { - "title": "Generated power (EB101)", + "title": "Generated power heating (EB101)", "factor": 10, "unit": "kW", "size": "u16", - "name": "generated-power-eb101-30407" + "name": "generated-power-heating-eb101-30407" }, "30408": { "title": "Time to defrosting (EB101)", @@ -1058,13 +902,6 @@ "size": "u16", "name": "high-condenser-in-alarm-s135-30577" }, - "30579": { - "title": "Average current (EME 10)", - "factor": 10, - "unit": "A", - "size": "s16", - "name": "average-current-eme-10-30579" - }, "30580": { "title": "Operating mode PV panels", "factor": 1, @@ -1490,11 +1327,11 @@ "name": "min-compressor-speed-eb100-30941" }, "30942": { - "title": "Generated power (EB100)", + "title": "Generated power heating (EB100)", "factor": 10, "unit": "kW", "size": "u16", - "name": "generated-power-eb100-30942" + "name": "generated-power-heating-eb100-30942" }, "30943": { "title": "Time to defrosting (EB100)", @@ -1920,7 +1757,7 @@ "31120": { "title": "Relay status, imm. heat. board (EB100-EP14)", "factor": 1, - "size": "u8", + "size": "u16", "name": "relay-status-imm-heat-board-eb100-ep14-31120" }, "31121": { @@ -2061,10 +1898,10 @@ "name": "compressor-oper-time-hot-water-eb101-ep14-31494" }, "31496": { - "title": "Alarm number (EB101-EP14)", + "title": "Alarm number (EB101)", "factor": 1, "size": "u16", - "name": "alarm-number-eb101-ep14-31496" + "name": "alarm-number-eb101-31496" }, "31498": { "title": "Heat pump type (EB100)", @@ -2120,18 +1957,11 @@ "size": "s16", "name": "calculated-cooling-supply-climate-system-1-31568" }, - "31590": { - "title": "Speed (GP12)", - "factor": 1, - "unit": "%", - "size": "u8", - "name": "speed-gp12-31590" - }, "40022": { "title": "Cooling pump manual speed", "factor": 1, "unit": "%", - "size": "s8", + "size": "u8", "min": 1.0, "max": 100.0, "default": 70.0, @@ -2290,12 +2120,6 @@ "size": "u8", "name": "sg-ready-input-b-31914" }, - "31915": { - "title": "Heating offset (SPA)", - "factor": 10, - "size": "s8", - "name": "heating-offset-spa-31915" - }, "31916": { "title": "Hot water comfort mode (SPA)", "factor": 1, @@ -2584,7 +2408,7 @@ "size": "s16", "min": 50.0, "max": 700.0, - "default": 440.0, + "default": 530.0, "name": "start-temperature-hw-high-temperature-40059", "write": true }, @@ -2595,7 +2419,7 @@ "size": "s16", "min": 50.0, "max": 700.0, - "default": 410.0, + "default": 480.0, "name": "start-temperature-hw-normal-temperature-40060", "write": true }, @@ -2606,7 +2430,7 @@ "size": "s16", "min": 50.0, "max": 700.0, - "default": 380.0, + "default": 430.0, "name": "start-temperature-hw-low-temperature-40061", "write": true }, @@ -2628,7 +2452,7 @@ "size": "s16", "min": 50.0, "max": 700.0, - "default": 480.0, + "default": 550.0, "name": "stop-temperature-hw-high-temperature-40063", "write": true }, @@ -2639,7 +2463,7 @@ "size": "s16", "min": 50.0, "max": 700.0, - "default": 450.0, + "default": 510.0, "name": "stop-temperature-hw-normal-temperature-40064", "write": true }, @@ -2650,7 +2474,7 @@ "size": "s16", "min": 50.0, "max": 700.0, - "default": 420.0, + "default": 480.0, "name": "stop-temperature-hw-low-temperature-40065", "write": true }, @@ -2785,6 +2609,36 @@ "name": "fuse-40104", "write": true }, + "42748": { + "title": "Phase Order L3", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 128.0, + "default": 4.0, + "name": "phase-order-l3-42748", + "write": true + }, + "42747": { + "title": "Phase Order L2", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 128.0, + "default": 2.0, + "name": "phase-order-l2-42747", + "write": true + }, + "42746": { + "title": "Phase Order L1", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 128.0, + "default": 1.0, + "name": "phase-order-l1-42746", + "write": true + }, "40121": { "title": "Floor drying", "factor": 1, @@ -3041,17 +2895,6 @@ "name": "step-controlled-additional-heat-accessory-40159", "write": true }, - "40160": { - "title": "DM start step controlled additional heat", - "factor": 1, - "unit": "DM", - "size": "s16", - "min": -2000.0, - "max": -30.0, - "default": -400.0, - "name": "dm-start-step-controlled-additional-heat-40160", - "write": true - }, "40166": { "title": "Waiting time cooling/heating", "factor": 1, @@ -3136,17 +2979,6 @@ "name": "permit-cooling-40183", "write": true }, - "40184": { - "title": "Auto mode, start temperature for cooling", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "min": 150.0, - "max": 400.0, - "default": 250.0, - "name": "auto-mode-start-temperature-for-cooling-40184", - "write": true - }, "40185": { "title": "Auto mode, stop temperature for heating", "factor": 10, @@ -3368,7 +3200,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux5-40212", "write": true @@ -3378,7 +3210,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux4-40213", "write": true @@ -3388,7 +3220,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux3-40214", "write": true @@ -3398,7 +3230,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux2-40215", "write": true @@ -3408,7 +3240,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux1-40216", "write": true @@ -3434,10 +3266,10 @@ "write": true }, "40226": { - "title": "More hot water", + "title": "More hot water (Number of minutes)", "factor": 1, "size": "u16", - "name": "more-hot-water-40226", + "name": "more-hot-water-number-of-minutes-40226", "write": true }, "40238": { @@ -3608,13 +3440,13 @@ "write": true }, "40749": { - "title": "Operating mode charge pump climate system 1", + "title": "Operating mode charge pump (EB101)", "factor": 1, "size": "u8", "min": 0.0, "max": 1.0, "default": 1.0, - "name": "operating-mode-charge-pump-climate-system-1-40749", + "name": "operating-mode-charge-pump-eb101-40749", "write": true }, "45269": { @@ -3660,7 +3492,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux6-40768", "write": true @@ -3685,17 +3517,6 @@ "name": "operating-mode-circulation-pump-hot-water-heat-pump-1-40800", "write": true }, - "40824": { - "title": "Speed circulation pump cooling heat pump 1", - "factor": 1, - "unit": "%", - "size": "u8", - "min": 1.0, - "max": 100.0, - "default": 70.0, - "name": "speed-circulation-pump-cooling-heat-pump-1-40824", - "write": true - }, "40833": { "title": "Operating mode circulation pump cooling heat pump 1", "factor": 1, @@ -3738,6 +3559,26 @@ "name": "activated-smart-price-adaption-40844", "write": true }, + "40845": { + "title": "(SPA), heating activated (SPA)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 3.0, + "default": 1.0, + "name": "spa-heating-activated-spa-40845", + "write": true + }, + "40847": { + "title": "(SPA), hot water activated", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 3.0, + "default": 1.0, + "name": "spa-hot-water-activated-40847", + "write": true + }, "40850": { "title": "(SPA), cooling activated", "factor": 1, @@ -3753,8 +3594,8 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 254.0, - "default": 23.0, + "max": 255.0, + "default": 255.0, "name": "spa-area-40852", "write": true }, @@ -3770,13 +3611,13 @@ "write": true }, "40876": { - "title": "Operating mode charge pump, cooling climate system 1", + "title": "Operating mode charge pump, cooling (EB101)", "factor": 1, "size": "u8", "min": 0.0, "max": 1.0, "default": 1.0, - "name": "operating-mode-charge-pump-cooling-climate-system-1-40876", + "name": "operating-mode-charge-pump-cooling-eb101-40876", "write": true }, "40894": { @@ -4478,16 +4319,6 @@ "name": "hysteresis-opt-41067", "write": true }, - "41069": { - "title": "Activated (EME10)", - "factor": 1, - "size": "u8", - "min": 0.0, - "max": 1.0, - "default": 0.0, - "name": "activated-eme10-41069", - "write": true - }, "41070": { "title": "PV panel affects heating (EME)", "factor": 1, @@ -5052,16 +4883,6 @@ "name": "end-month-tariff-ext-step-add-heat-smart-energy-source-41284", "write": true }, - "41321": { - "title": "Prioritise additional heat (AXC40)", - "factor": 1, - "size": "u8", - "min": 0.0, - "max": 1.0, - "default": 0.0, - "name": "prioritise-additional-heat-axc40-41321", - "write": true - }, "41327": { "title": "Max difference, SES priority 1 energy source", "factor": 10, @@ -5492,6 +5313,17 @@ "name": "night-cooling-diff-42944", "write": true }, + "45344": { + "title": "Silent mode, max. frequency 2 (EB101)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "min": 25.0, + "max": 120.0, + "default": 120.0, + "name": "silent-mode-max-frequency-2-eb101-45344", + "write": true + }, "45353": { "title": "Minimum permitted speed (EB101 GP12)", "factor": 1, @@ -5513,6 +5345,16 @@ "name": "start-fan-de-icing-eb101-45361", "write": true }, + "45369": { + "title": "Defrost Requested EB101", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "defrost-requested-eb101-45369", + "write": true + }, "40177": { "title": "System 1 (RMU)", "factor": 1, @@ -5671,12 +5513,6 @@ "size": "s16", "name": "hot-water-start-bt5-32015" }, - "32129": { - "title": "Pump: Heating medium (GP6)", - "factor": 1, - "size": "u8", - "name": "pump-heating-medium-gp6-32129" - }, "43089": { "title": "Period", "factor": 1, @@ -6721,7 +6557,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "aux-from-modbus-42741", "write": true @@ -6964,6 +6800,16 @@ "name": "disable-emergency-restart-gp1-45026", "write": true }, + "45009": { + "title": "Modbus external control", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "modbus-external-control-45009", + "write": true + }, "30001": { "title": "Relay status", "factor": 1, @@ -7126,26 +6972,33 @@ "size": "u32", "name": "hot-water-including-int-add-heat-31576" }, + "33801": { + "title": "Boiler temperature (BT52)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "boiler-temperature-bt52-33801" + }, "32801": { - "title": "Temperature: HTS 1", + "title": "Temperature: RMU S40", "factor": 10, "unit": "\u00b0C", "size": "s32", - "name": "temperature-hts-1-32801" + "name": "temperature-rmu-s40-32801" }, "33131": { - "title": "Humidity: HTS 1", + "title": "Humidity: RMU S40", "factor": 10, "unit": "%RH", "size": "s32", - "name": "humidity-hts-1-33131" + "name": "humidity-rmu-s40-33131" }, "41556": { "title": "Input AUX7", "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux7-41556", "write": true @@ -7155,7 +7008,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux8-41557", "write": true @@ -7165,7 +7018,7 @@ "factor": 1, "size": "u8", "min": 0.0, - "max": 67.0, + "max": 68.0, "default": 0.0, "name": "input-aux9-41558", "write": true @@ -7191,20 +7044,6 @@ "name": "disable-emergency-restart-gp1-43987", "write": true }, - "32191": { - "title": "Return line (AZ2-BT69)", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "return-line-az2-bt69-32191" - }, - "32192": { - "title": "Supply line (AZ2-BT68)", - "factor": 10, - "unit": "\u00b0C", - "size": "s16", - "name": "supply-line-az2-bt68-32192" - }, "32414": { "title": "EEV Control Mode (EB101)", "factor": 1, From 688a263a7c875dd7b241d04d717040526ff44b16 Mon Sep 17 00:00:00 2001 From: Martijn Russchen Date: Fri, 24 Jan 2025 11:48:26 +0100 Subject: [PATCH 2/3] Revert first set of deletions --- nibe/data/s2125.csv | 25 ++++++ nibe/data/s2125.json | 176 +++++++++++++++++++++++++++++++++++++++++++ 2 files changed, 201 insertions(+) diff --git a/nibe/data/s2125.csv b/nibe/data/s2125.csv index 810bfbc..85cee3f 100755 --- a/nibe/data/s2125.csv +++ b/nibe/data/s2125.csv @@ -7,11 +7,13 @@ Supply line (BT2) MODBUS_INPUT_REGISTER 5 10 °C 2 0 0 0 Return line (BT3) MODBUS_INPUT_REGISTER 7 10 °C 2 0 0 0 Hot water top (BT7) MODBUS_INPUT_REGISTER 8 10 °C 2 0 0 0 Hot water charging (BT6) MODBUS_INPUT_REGISTER 9 10 °C 2 0 0 0 +Roomsensor 1-1 MODBUS_INPUT_REGISTER 26 10 °C 2 0 0 0 Temperature limiter (EB100-FD1) MODBUS_INPUT_REGISTER 36 1 2 0 0 0 Average temperature (BT1) MODBUS_INPUT_REGISTER 37 10 °C 2 0 0 0 Boiler temperature (BT52) MODBUS_INPUT_REGISTER 38 10 °C 2 0 0 0 Flow sensor (BF1) MODBUS_INPUT_REGISTER 40 10 l/m 2 0 0 0 Electrical anode (EB100-FR1) MODBUS_INPUT_REGISTER 41 1 2 0 0 0 +Current (BE3) MODBUS_INPUT_REGISTER 46 10 A 6 0 0 0 - MODBUS_INPUT_REGISTER 60 10 °C 2 0 0 0 - MODBUS_INPUT_REGISTER 61 10 °C 2 0 0 0 - MODBUS_INPUT_REGISTER 62 10 °C 2 0 0 0 @@ -43,6 +45,8 @@ Room average temp. clim. system 2 (BT50) MODBUS_INPUT_REGISTER 115 10 °C 2 0 0 Room average temp. clim. system 1 (BT50) MODBUS_INPUT_REGISTER 116 10 °C 2 0 0 0 External cooling supply temperature (BT25) MODBUS_INPUT_REGISTER 119 10 °C 2 0 0 0 id:193 MODBUS_INPUT_REGISTER 128 1 4 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 Oper. mode shunt climate system 8 MODBUS_INPUT_REGISTER 129 1 4 0 0 0 Oper. mode shunt climate system 7 MODBUS_INPUT_REGISTER 130 1 4 0 0 0 Oper. mode shunt climate system 6 MODBUS_INPUT_REGISTER 131 1 4 0 0 0 @@ -80,6 +84,22 @@ Available compressors heating MODBUS_INPUT_REGISTER 317 1 4 0 0 0 Available compressors hot water MODBUS_INPUT_REGISTER 318 1 4 0 0 0 Available compressors pool 1 MODBUS_INPUT_REGISTER 319 1 4 0 0 0 Available compressors cooling MODBUS_INPUT_REGISTER 321 1 4 0 0 0 ++Adjust, port MODBUS_INPUT_REGISTER 327 1 4 0 0 0 ++Adjust, operating mode MODBUS_INPUT_REGISTER 328 1 4 0 0 0 ++Adjust, comfort MODBUS_INPUT_REGISTER 329 1 4 0 0 0 ++Adjust, parallel adjustment MODBUS_INPUT_REGISTER 330 1 1 0 0 0 ++Adjust, humidity MODBUS_INPUT_REGISTER 331 10 %RH 2 0 0 0 ++Adjust, indoor temperature MODBUS_INPUT_REGISTER 332 10 °C 2 0 0 0 ++Adjust, outdoor temperature MODBUS_INPUT_REGISTER 333 10 °C 2 0 0 0 ++Adjust, version MODBUS_INPUT_REGISTER 334 1 5 0 0 0 ++Adjust, active MODBUS_INPUT_REGISTER 335 1 4 0 0 0 ++Adjust, demand MODBUS_INPUT_REGISTER 336 1 4 0 0 0 ++Adjust, parallel factor MODBUS_HOLDING_REGISTER 1 1 1 1 10 5 ++Adjust, Parallel (min-max) MODBUS_HOLDING_REGISTER 2 1 1 1 100 100 +Humidity (BM1) MODBUS_INPUT_REGISTER 323 10 % 2 0 0 0 +Temperature (BM1) MODBUS_INPUT_REGISTER 324 10 °C 2 0 0 0 +Pressure (BM1) MODBUS_INPUT_REGISTER 325 10 kPa 2 0 0 0 +Dew point (BM1) MODBUS_INPUT_REGISTER 326 10 °C 2 0 0 0 Supply temperature (BT64) MODBUS_INPUT_REGISTER 337 10 °C 2 0 0 0 Heat pump functionality 2 MODBUS_INPUT_REGISTER 338 1 6 0 0 0 Status (S135) MODBUS_INPUT_REGISTER 344 1 4 0 0 0 @@ -88,6 +108,8 @@ Status, demand, fan speed (S135) MODBUS_INPUT_REGISTER 346 1 4 0 0 0 Status, solenoid (S135) MODBUS_INPUT_REGISTER 347 1 4 0 0 0 Status, compressor, heater(S135) MODBUS_INPUT_REGISTER 348 1 4 0 0 0 Status, compressor, demand (S135) MODBUS_INPUT_REGISTER 350 1 4 0 0 0 +No. of starts (S135) MODBUS_INPUT_REGISTER 351 1 6 0 9999999 0 +Operating time (S135) MODBUS_INPUT_REGISTER 353 1 h 6 0 9999999 0 Degree minutes MODBUS_HOLDING_REGISTER 11 10 DM 3 -30000 30000 0 Blocking (ERS 1) MODBUS_INPUT_REGISTER 358 1 4 0 0 0 AZ30-EB17 MODBUS_INPUT_REGISTER 359 1 4 0 0 0 @@ -151,6 +173,7 @@ Fan status (EB101-EP14) MODBUS_INPUT_REGISTER 556 1 4 0 0 0 Fan rpm (EB101-EP14) MODBUS_INPUT_REGISTER 557 1 rpm 5 0 0 0 High condenser out alarm (S135) MODBUS_INPUT_REGISTER 575 1 5 0 0 0 High condenser in alarm (S135) MODBUS_INPUT_REGISTER 576 1 5 0 0 0 +Average current (EME 10) MODBUS_INPUT_REGISTER 578 10 A 2 0 0 0 Operating mode PV panels MODBUS_INPUT_REGISTER 579 1 4 0 0 0 EME lux mode without EME MODBUS_INPUT_REGISTER 581 1 4 0 0 0 Timer (EME) MODBUS_INPUT_REGISTER 582 60 min 5 0 0 0 @@ -316,6 +339,7 @@ Blocked compressors MODBUS_INPUT_REGISTER 2174 1 6 0 0 0 Cooling degree minutes MODBUS_HOLDING_REGISTER 20 10 DM 2 -30000 30000 0 Calculated cooling supply climate system 1 MODBUS_INPUT_REGISTER 1567 10 °C 2 0 0 0 id:2728 MODBUS_HOLDING_REGISTER 3099 1 3 0 9999999 0 +Speed (GP12) MODBUS_INPUT_REGISTER 1589 1 % 4 0 0 0 Cooling pump manual speed MODBUS_HOLDING_REGISTER 21 1 % 4 1 100 70 Outdoor temperature (EB101-BT28) MODBUS_INPUT_REGISTER 1621 10 °C 2 0 0 0 Evaporator (EB101-BT16) MODBUS_INPUT_REGISTER 1622 10 °C 2 0 0 0 @@ -342,6 +366,7 @@ Current sensor (EB101-EP14) MODBUS_INPUT_REGISTER 1903 10 A 2 0 0 0 Operating mode (SG Ready) MODBUS_INPUT_REGISTER 1911 1 4 0 0 0 SG ready, input A MODBUS_INPUT_REGISTER 1912 1 4 0 0 0 SG ready, input B MODBUS_INPUT_REGISTER 1913 1 4 0 0 0 +Heating offset (SPA) MODBUS_INPUT_REGISTER 1914 10 Hot water comfort mode (SPA) MODBUS_INPUT_REGISTER 1915 1 1 0 0 0 Pool offset (SPA) MODBUS_INPUT_REGISTER 1916 1 1 0 0 0 Cooling offset (SPA) MODBUS_INPUT_REGISTER 1917 1 1 0 0 0 diff --git a/nibe/data/s2125.json b/nibe/data/s2125.json index 0f50c2a..c24dd6d 100644 --- a/nibe/data/s2125.json +++ b/nibe/data/s2125.json @@ -55,6 +55,13 @@ "size": "s16", "name": "hot-water-charging-bt6-30010" }, + "30027": { + "title": "Roomsensor 1-1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "roomsensor-1-1-30027" + }, "30037": { "title": "Temperature limiter (EB100-FD1)", "factor": 1, @@ -88,6 +95,13 @@ "size": "s16", "name": "electrical-anode-eb100-fr1-30042" }, + "30047": { + "title": "Current (BE3)", + "factor": 10, + "unit": "A", + "size": "u32", + "name": "current-be3-30047" + }, "30073": { "title": "Additional heat (BT63)", "factor": 10, @@ -249,6 +263,18 @@ "size": "s16", "name": "external-cooling-supply-temperature-bt25-30120" }, + "30143": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30143" + }, + "30144": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30144" + }, "30130": { "title": "Oper. mode shunt climate system 8", "factor": 1, @@ -478,6 +504,117 @@ "size": "u8", "name": "available-compressors-cooling-30322" }, + "30328": { + "title": "+Adjust, port", + "factor": 1, + "size": "u8", + "name": "adjust-port-30328" + }, + "30329": { + "title": "+Adjust, operating mode", + "factor": 1, + "size": "u8", + "name": "adjust-operating-mode-30329" + }, + "30330": { + "title": "+Adjust, comfort", + "factor": 1, + "size": "u8", + "name": "adjust-comfort-30330" + }, + "30331": { + "title": "+Adjust, parallel adjustment", + "factor": 1, + "size": "s8", + "name": "adjust-parallel-adjustment-30331" + }, + "30332": { + "title": "+Adjust, humidity", + "factor": 10, + "unit": "%RH", + "size": "s16", + "name": "adjust-humidity-30332" + }, + "30333": { + "title": "+Adjust, indoor temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "adjust-indoor-temperature-30333" + }, + "30334": { + "title": "+Adjust, outdoor temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "adjust-outdoor-temperature-30334" + }, + "30335": { + "title": "+Adjust, version", + "factor": 1, + "size": "u16", + "name": "adjust-version-30335" + }, + "30336": { + "title": "+Adjust, active", + "factor": 1, + "size": "u8", + "name": "adjust-active-30336" + }, + "30337": { + "title": "+Adjust, demand", + "factor": 1, + "size": "u8", + "name": "adjust-demand-30337" + }, + "40002": { + "title": "+Adjust, parallel factor", + "factor": 1, + "size": "s8", + "min": 1.0, + "max": 10.0, + "default": 5.0, + "name": "adjust-parallel-factor-40002", + "write": true + }, + "40003": { + "title": "+Adjust, Parallel (min-max)", + "factor": 1, + "size": "s8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "adjust-parallel-min-max-40003", + "write": true + }, + "30324": { + "title": "Humidity (BM1)", + "factor": 10, + "unit": "%", + "size": "s16", + "name": "humidity-bm1-30324" + }, + "30325": { + "title": "Temperature (BM1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-bm1-30325" + }, + "30326": { + "title": "Pressure (BM1)", + "factor": 10, + "unit": "kPa", + "size": "s16", + "name": "pressure-bm1-30326" + }, + "30327": { + "title": "Dew point (BM1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "dew-point-bm1-30327" + }, "30338": { "title": "Supply temperature (BT64)", "factor": 10, @@ -527,6 +664,25 @@ "size": "u8", "name": "status-compressor-demand-s135-30351" }, + "30352": { + "title": "No. of starts (S135)", + "factor": 1, + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "no-of-starts-s135-30352" + }, + "30354": { + "title": "Operating time (S135)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "operating-time-s135-30354" + }, "40012": { "title": "Degree minutes", "factor": 10, @@ -902,6 +1058,13 @@ "size": "u16", "name": "high-condenser-in-alarm-s135-30577" }, + "30579": { + "title": "Average current (EME 10)", + "factor": 10, + "unit": "A", + "size": "s16", + "name": "average-current-eme-10-30579" + }, "30580": { "title": "Operating mode PV panels", "factor": 1, @@ -1957,6 +2120,13 @@ "size": "s16", "name": "calculated-cooling-supply-climate-system-1-31568" }, + "31590": { + "title": "Speed (GP12)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "speed-gp12-31590" + }, "40022": { "title": "Cooling pump manual speed", "factor": 1, @@ -2120,6 +2290,12 @@ "size": "u8", "name": "sg-ready-input-b-31914" }, + "31915": { + "title": "Heating offset (SPA)", + "factor": 10, + "size": "u16", + "name": "heating-offset-spa-31915" + }, "31916": { "title": "Hot water comfort mode (SPA)", "factor": 1, From 3bc31ff1aa229676fa04e5e3dafb066833e87cc0 Mon Sep 17 00:00:00 2001 From: Martijn Russchen Date: Fri, 24 Jan 2025 11:53:33 +0100 Subject: [PATCH 3/3] More restores --- nibe/data/s2125.csv | 14 +++++-- nibe/data/s2125.json | 97 ++++++++++++++++++++++++++++++++++++++------ 2 files changed, 96 insertions(+), 15 deletions(-) diff --git a/nibe/data/s2125.csv b/nibe/data/s2125.csv index 85cee3f..c0ded7e 100755 --- a/nibe/data/s2125.csv +++ b/nibe/data/s2125.csv @@ -1,4 +1,4 @@ -Title Register type Register Division factor Unit Size of variable Min value Max value Default value +Title Register type Register Division factor Unit Size of variable Min value Max value Default value Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0 Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0 Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0 @@ -45,8 +45,6 @@ Room average temp. clim. system 2 (BT50) MODBUS_INPUT_REGISTER 115 10 °C 2 0 0 Room average temp. clim. system 1 (BT50) MODBUS_INPUT_REGISTER 116 10 °C 2 0 0 0 External cooling supply temperature (BT25) MODBUS_INPUT_REGISTER 119 10 °C 2 0 0 0 id:193 MODBUS_INPUT_REGISTER 128 1 4 0 0 0 -Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 -Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 Oper. mode shunt climate system 8 MODBUS_INPUT_REGISTER 129 1 4 0 0 0 Oper. mode shunt climate system 7 MODBUS_INPUT_REGISTER 130 1 4 0 0 0 Oper. mode shunt climate system 6 MODBUS_INPUT_REGISTER 131 1 4 0 0 0 @@ -57,6 +55,8 @@ Fan speed (AZ30-GQ2) MODBUS_INPUT_REGISTER 135 1 % 4 0 0 0 Fan speed (AZ30-GQ3) MODBUS_INPUT_REGISTER 136 1 % 4 0 0 0 Current hot water mode controlled by MODBUS_INPUT_REGISTER 137 1 1 0 0 0 Max. compressor frequency, heating MODBUS_INPUT_REGISTER 141 100 Hz 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 External adjustment climate system 8 MODBUS_INPUT_REGISTER 151 1 4 0 0 0 External adjustment climate system 7 MODBUS_INPUT_REGISTER 152 1 4 0 0 0 External adjustment climate system 6 MODBUS_INPUT_REGISTER 153 1 4 0 0 0 @@ -446,6 +446,7 @@ Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0 Shunt controlled additional heat MODBUS_HOLDING_REGISTER 153 1 4 0 1 0 Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30 Step controlled additional heat accessory MODBUS_HOLDING_REGISTER 158 1 4 0 1 0 +DM start step controlled additional heat MODBUS_HOLDING_REGISTER 159 1 DM 2 -2000 -30 -400 Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2 Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10 Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30 @@ -454,6 +455,7 @@ Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 30 Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1 Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1 Permit cooling MODBUS_HOLDING_REGISTER 182 1 4 0 1 1 +Auto mode, start temperature for cooling MODBUS_HOLDING_REGISTER 183 10 °C 2 150 400 250 Auto mode, stop temperature for heating MODBUS_HOLDING_REGISTER 184 10 °C 2 -200 400 170 Auto mode, additional heat stop temperature MODBUS_HOLDING_REGISTER 185 10 °C 2 -250 400 50 Auto mode filter time MODBUS_HOLDING_REGISTER 186 1 h 4 0 48 24 @@ -525,6 +527,7 @@ id:4710 MODBUS_HOLDING_REGISTER 5279 1 4 0 1 0 Input AUX6 MODBUS_HOLDING_REGISTER 767 1 4 0 68 0 Operating mode circulation pump heating heat pump 1 MODBUS_HOLDING_REGISTER 783 1 4 0 1 1 Operating mode circulation pump hot water heat pump 1 MODBUS_HOLDING_REGISTER 799 1 4 0 1 1 +Speed circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 823 1 % 4 1 100 70 Operating mode circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 832 1 4 0 1 1 Speed circulation pump waiting mode heat pump 1 MODBUS_HOLDING_REGISTER 841 1 % 4 1 100 30 Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 1 100 30 @@ -608,6 +611,7 @@ Flow sensor activated X22 MODBUS_HOLDING_REGISTER 1049 1 4 0 1 0 Max. internal additional heat SG Ready MODBUS_HOLDING_REGISTER 1052 100 kW 2 0 900 900 Limit humidity in the room, cooling climate system 1 MODBUS_HOLDING_REGISTER 1063 1 1 0 1 0 Hysteresis (OPT) MODBUS_HOLDING_REGISTER 1066 1 2 10 2000 100 +Activated (EME10) MODBUS_HOLDING_REGISTER 1068 1 4 0 1 0 PV panel affects heating (EME) MODBUS_HOLDING_REGISTER 1069 1 4 0 1 0 PV panel affects hot water (EME) MODBUS_HOLDING_REGISTER 1070 1 4 0 1 0 Delay timer EME MODBUS_HOLDING_REGISTER 1071 1 5 0 0 0 @@ -665,6 +669,7 @@ Start day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTE End day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1281 1 4 1 31 31 Start month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1282 1 4 1 12 1 End month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1283 1 4 1 12 12 +Prioritise additional heat (AXC40) MODBUS_HOLDING_REGISTER 1320 1 4 0 1 0 Max difference, SES priority 1 energy source MODBUS_HOLDING_REGISTER 1326 10 °C 2 10 250 100 Max difference, SES lower priority energy source MODBUS_HOLDING_REGISTER 1327 10 °C 2 10 250 70 Installed (EB101) MODBUS_HOLDING_REGISTER 1550 1 4 0 1 1 @@ -772,6 +777,7 @@ Factor MODBUS_HOLDING_REGISTER 3033 1 4 1 10 5 id:10881 MODBUS_HOLDING_REGISTER 3062 1 4 0 1 0 id:10890 MODBUS_HOLDING_REGISTER 3063 1 4 0 1 0 Hot water start (BT5) MODBUS_INPUT_REGISTER 2014 10 °C 2 0 0 0 +Pump: Heating medium (GP6) MODBUS_INPUT_REGISTER 2128 1 4 0 0 0 id:12332 MODBUS_HOLDING_REGISTER 2767 1 2 -32768 32767 -32768 id:12333 MODBUS_HOLDING_REGISTER 2768 1 2 -32768 32767 -32768 id:12334 MODBUS_HOLDING_REGISTER 2769 1 2 -32768 32767 -32768 @@ -1472,6 +1478,8 @@ id:55082 MODBUS_HOLDING_REGISTER 2883 1 4 0 1 0 id:55083 MODBUS_HOLDING_REGISTER 2884 1 4 0 1 0 Immersion heater power, emergency mode MODBUS_HOLDING_REGISTER 3028 100 kW 2 0 4500 600 Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 3986 1 4 0 1 0 +Return line (AZ2-BT69) MODBUS_INPUT_REGISTER 2190 10 °C 2 0 0 0 +Supply line (AZ2-BT68) MODBUS_INPUT_REGISTER 2191 10 °C 2 0 0 0 "EEV Control Mode (EB101)" MODBUS_INPUT_REGISTER 2413 1 4 0 0 0 "EEV State (EB101)" MODBUS_INPUT_REGISTER 2421 1 4 0 0 0 id:55495 MODBUS_HOLDING_REGISTER 5550 1 4 0 1 0 diff --git a/nibe/data/s2125.json b/nibe/data/s2125.json index c24dd6d..7a1c26c 100644 --- a/nibe/data/s2125.json +++ b/nibe/data/s2125.json @@ -263,18 +263,6 @@ "size": "s16", "name": "external-cooling-supply-temperature-bt25-30120" }, - "30143": { - "title": "Inverter alarm code", - "factor": 1, - "size": "u16", - "name": "inverter-alarm-code-30143" - }, - "30144": { - "title": "Inverter alarm code", - "factor": 1, - "size": "u16", - "name": "inverter-alarm-code-30144" - }, "30130": { "title": "Oper. mode shunt climate system 8", "factor": 1, @@ -332,6 +320,18 @@ "size": "u16", "name": "max-compressor-frequency-heating-30142" }, + "30143": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30143" + }, + "30144": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30144" + }, "30152": { "title": "External adjustment climate system 8", "factor": 1, @@ -3071,6 +3071,17 @@ "name": "step-controlled-additional-heat-accessory-40159", "write": true }, + "40160": { + "title": "DM start step controlled additional heat", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": -2000.0, + "max": -30.0, + "default": -400.0, + "name": "dm-start-step-controlled-additional-heat-40160", + "write": true + }, "40166": { "title": "Waiting time cooling/heating", "factor": 1, @@ -3155,6 +3166,17 @@ "name": "permit-cooling-40183", "write": true }, + "40184": { + "title": "Auto mode, start temperature for cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 150.0, + "max": 400.0, + "default": 250.0, + "name": "auto-mode-start-temperature-for-cooling-40184", + "write": true + }, "40185": { "title": "Auto mode, stop temperature for heating", "factor": 10, @@ -3693,6 +3715,17 @@ "name": "operating-mode-circulation-pump-hot-water-heat-pump-1-40800", "write": true }, + "40824": { + "title": "Speed circulation pump cooling heat pump 1", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-circulation-pump-cooling-heat-pump-1-40824", + "write": true + }, "40833": { "title": "Operating mode circulation pump cooling heat pump 1", "factor": 1, @@ -4495,6 +4528,16 @@ "name": "hysteresis-opt-41067", "write": true }, + "41069": { + "title": "Activated (EME10)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "activated-eme10-41069", + "write": true + }, "41070": { "title": "PV panel affects heating (EME)", "factor": 1, @@ -5059,6 +5102,16 @@ "name": "end-month-tariff-ext-step-add-heat-smart-energy-source-41284", "write": true }, + "41321": { + "title": "Prioritise additional heat (AXC40)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "prioritise-additional-heat-axc40-41321", + "write": true + }, "41327": { "title": "Max difference, SES priority 1 energy source", "factor": 10, @@ -5689,6 +5742,12 @@ "size": "s16", "name": "hot-water-start-bt5-32015" }, + "32129": { + "title": "Pump: Heating medium (GP6)", + "factor": 1, + "size": "u8", + "name": "pump-heating-medium-gp6-32129" + }, "43089": { "title": "Period", "factor": 1, @@ -7220,6 +7279,20 @@ "name": "disable-emergency-restart-gp1-43987", "write": true }, + "32191": { + "title": "Return line (AZ2-BT69)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-az2-bt69-32191" + }, + "32192": { + "title": "Supply line (AZ2-BT68)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-az2-bt68-32192" + }, "32414": { "title": "EEV Control Mode (EB101)", "factor": 1,