From 5f0f5e3e7ece9923dad0242e466db145e4e890f0 Mon Sep 17 00:00:00 2001 From: Joakim Plate Date: Fri, 2 Dec 2022 21:41:42 +0100 Subject: [PATCH 1/4] Add s2125 --- nibe/data/s2125.csv | 1181 ++++++++ nibe/data/s2125.json | 6746 ++++++++++++++++++++++++++++++++++++++++++ nibe/heatpump.py | 2 + 3 files changed, 7929 insertions(+) create mode 100644 nibe/data/s2125.csv create mode 100644 nibe/data/s2125.json diff --git a/nibe/data/s2125.csv b/nibe/data/s2125.csv new file mode 100644 index 0000000..20ebd9d --- /dev/null +++ b/nibe/data/s2125.csv @@ -0,0 +1,1181 @@ +Title Register type Register Division factor Unit Size of variable Min value Max value Default value +Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0 +Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0 +Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0 +Supply line (EP21-BT2) MODBUS_INPUT_REGISTER 4 10 °C 2 0 0 0 +Supply line (BT2) MODBUS_INPUT_REGISTER 5 10 °C 2 0 0 0 +Return line (BT3) MODBUS_INPUT_REGISTER 7 10 °C 2 0 0 0 +Hot water top (BT7) MODBUS_INPUT_REGISTER 8 10 °C 2 0 0 0 +Hot water charging (BT6) MODBUS_INPUT_REGISTER 9 10 °C 2 0 0 0 +Roomsensor 1-1 MODBUS_INPUT_REGISTER 26 10 °C 2 0 0 0 +Temperature limiter (EB100-FD1) MODBUS_INPUT_REGISTER 36 1 2 0 0 0 +Average temperature (BT1) MODBUS_INPUT_REGISTER 37 10 °C 2 0 0 0 +Boiler temperature (BT52) MODBUS_INPUT_REGISTER 38 10 °C 2 0 0 0 +Flow sensor (BF1) MODBUS_INPUT_REGISTER 40 10 l/m 2 0 0 0 +Electrical anode (EB100-FR1) MODBUS_INPUT_REGISTER 41 1 2 0 0 0 +Current (BE3) MODBUS_INPUT_REGISTER 46 10 A 6 0 0 0 +- MODBUS_INPUT_REGISTER 60 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 61 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 62 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 63 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 64 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 65 10 °C 2 0 0 0 +Additional heat (BT63) MODBUS_INPUT_REGISTER 72 10 °C 2 0 0 0 +Return line (EP23-BT3) MODBUS_INPUT_REGISTER 75 10 °C 2 0 0 0 +Return line (EP22-BT3) MODBUS_INPUT_REGISTER 76 10 °C 2 0 0 0 +Return line (EP21-BT3) MODBUS_INPUT_REGISTER 77 10 °C 2 0 0 0 +Return line (EP15-BT3) MODBUS_INPUT_REGISTER 78 10 °C 2 0 0 0 +Outgoing hot water (BT70) MODBUS_INPUT_REGISTER 87 10 °C 2 0 0 0 +Supply line (EP47-BT2) MODBUS_INPUT_REGISTER 94 10 °C 2 0 0 0 +Supply line (EP46-BT2) MODBUS_INPUT_REGISTER 95 10 °C 2 0 0 0 +Supply line (EP45-BT2) MODBUS_INPUT_REGISTER 96 10 °C 2 0 0 0 +Supply line (EP44-BT2) MODBUS_INPUT_REGISTER 97 10 °C 2 0 0 0 +Return line (EP47-BT3) MODBUS_INPUT_REGISTER 98 10 °C 2 0 0 0 +Return line (EP46-BT3) MODBUS_INPUT_REGISTER 99 10 °C 2 0 0 0 +Return line (EP45-BT3) MODBUS_INPUT_REGISTER 100 10 °C 2 0 0 0 +Return line (EP44-BT3) MODBUS_INPUT_REGISTER 101 10 °C 2 0 0 0 +id:149 MODBUS_INPUT_REGISTER 108 10 °C 2 0 0 0 +Room average temp. clim. system 8 (BT50) MODBUS_INPUT_REGISTER 109 10 °C 2 0 0 0 +Room average temp. clim. system 7 (BT50) MODBUS_INPUT_REGISTER 110 10 °C 2 0 0 0 +Room average temp. clim. system 6 (BT50) MODBUS_INPUT_REGISTER 111 10 °C 2 0 0 0 +Room average temp. clim. system 5 (BT50) MODBUS_INPUT_REGISTER 112 10 °C 2 0 0 0 +Room average temp. clim. system 4 (BT50) MODBUS_INPUT_REGISTER 113 10 °C 2 0 0 0 +Room average temp. clim. system 3 (BT50) MODBUS_INPUT_REGISTER 114 10 °C 2 0 0 0 +Room average temp. clim. system 2 (BT50) MODBUS_INPUT_REGISTER 115 10 °C 2 0 0 0 +Room average temp. clim. system 1 (BT50) MODBUS_INPUT_REGISTER 116 10 °C 2 0 0 0 +External cooling supply temperature (BT25) MODBUS_INPUT_REGISTER 119 10 °C 2 0 0 0 +id:193 MODBUS_INPUT_REGISTER 128 1 4 0 0 0 +Oper. mode shunt climate system 8 MODBUS_INPUT_REGISTER 129 1 4 0 0 0 +Oper. mode shunt climate system 7 MODBUS_INPUT_REGISTER 130 1 4 0 0 0 +Oper. mode shunt climate system 6 MODBUS_INPUT_REGISTER 131 1 4 0 0 0 +Oper. mode shunt climate system 5 MODBUS_INPUT_REGISTER 132 1 4 0 0 0 +id:246 MODBUS_INPUT_REGISTER 133 1 4 0 0 0 +Relay status (ERS 1) MODBUS_INPUT_REGISTER 134 1 4 0 0 0 +Fan speed (AZ30-GQ2) MODBUS_INPUT_REGISTER 135 1 % 4 0 0 0 +Fan speed (AZ30-GQ3) MODBUS_INPUT_REGISTER 136 1 % 4 0 0 0 +Current hot water mode controlled by MODBUS_INPUT_REGISTER 137 1 1 0 0 0 +Max. compressor frequency, heating MODBUS_INPUT_REGISTER 141 100 Hz 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 +External adjustment climate system 8 MODBUS_INPUT_REGISTER 151 1 4 0 0 0 +External adjustment climate system 7 MODBUS_INPUT_REGISTER 152 1 4 0 0 0 +External adjustment climate system 6 MODBUS_INPUT_REGISTER 153 1 4 0 0 0 +External adjustment climate system 5 MODBUS_INPUT_REGISTER 154 1 4 0 0 0 +Climate system 8 MODBUS_INPUT_REGISTER 156 1 4 0 0 0 +Climate system 7 MODBUS_INPUT_REGISTER 157 1 4 0 0 0 +Climate system 6 MODBUS_INPUT_REGISTER 158 1 4 0 0 0 +Climate system 5 MODBUS_INPUT_REGISTER 159 1 4 0 0 0 +Hot water comfort return (BT82) MODBUS_INPUT_REGISTER 174 10 °C 2 0 0 0 +Hot water comfort heater (BT83) MODBUS_INPUT_REGISTER 175 10 °C 2 0 0 0 +id:599 MODBUS_INPUT_REGISTER 267 1 h 6 -2147483648 2147483647 0 +id:600 MODBUS_INPUT_REGISTER 269 1 h 6 -2147483648 2147483647 0 +id:601 MODBUS_INPUT_REGISTER 271 1 h 6 -2147483648 2147483647 0 +Compressor, total time cooling, main unit (EP14) MODBUS_INPUT_REGISTER 279 1 h 6 -2147483648 2147483647 0 +Compressor, total time pool, main unit (EP14) MODBUS_INPUT_REGISTER 281 1 h 6 -2147483648 2147483647 0 +Compressor, total time pool 2, main unit (EP14) MODBUS_INPUT_REGISTER 283 1 h 6 -2147483648 2147483647 0 +Heat pump 1 requested compressor frequency MODBUS_INPUT_REGISTER 301 1 Hz 4 0 0 0 +Main unit, requested compressor freq MODBUS_INPUT_REGISTER 302 1 Hz 4 0 0 0 +Frost protection heat exchanger, main unit MODBUS_INPUT_REGISTER 310 1 4 0 0 0 +Status (OPT) MODBUS_INPUT_REGISTER 311 1 4 0 0 0 +Version (OPT) MODBUS_INPUT_REGISTER 312 1 5 0 0 0 +OPT relay, modulation level MODBUS_INPUT_REGISTER 313 10 % 2 0 0 0 +OPT operating time MODBUS_INPUT_REGISTER 315 1 h 5 0 0 0 +Available compressors heating MODBUS_INPUT_REGISTER 317 1 4 0 0 0 +Available compressors hot water MODBUS_INPUT_REGISTER 318 1 4 0 0 0 +Available compressors pool 1 MODBUS_INPUT_REGISTER 319 1 4 0 0 0 +Available compressors cooling MODBUS_INPUT_REGISTER 321 1 4 0 0 0 ++Adjust, port MODBUS_INPUT_REGISTER 327 1 4 0 0 0 ++Adjust, operating mode MODBUS_INPUT_REGISTER 328 1 4 0 0 0 ++Adjust, comfort MODBUS_INPUT_REGISTER 329 1 4 0 0 0 ++Adjust, parallel adjustment MODBUS_INPUT_REGISTER 330 1 1 0 0 0 ++Adjust, humidity MODBUS_INPUT_REGISTER 331 10 %RH 2 0 0 0 ++Adjust, indoor temperature MODBUS_INPUT_REGISTER 332 10 °C 2 0 0 0 ++Adjust, outdoor temperature MODBUS_INPUT_REGISTER 333 10 °C 2 0 0 0 ++Adjust, version MODBUS_INPUT_REGISTER 334 1 5 0 0 0 ++Adjust, active MODBUS_INPUT_REGISTER 335 1 4 0 0 0 ++Adjust, demand MODBUS_INPUT_REGISTER 336 1 4 0 0 0 ++Adjust, parallel factor MODBUS_HOLDING_REGISTER 1 1 1 1 10 5 ++Adjust, Parallel (min-max) MODBUS_HOLDING_REGISTER 2 1 1 1 100 100 +Supply temperature (BT64) MODBUS_INPUT_REGISTER 337 10 °C 2 0 0 0 +Heat pump functionality 2 MODBUS_INPUT_REGISTER 338 1 6 0 0 0 +Status (S135) MODBUS_INPUT_REGISTER 344 1 4 0 0 0 +Status, demand, pump speed (S135) MODBUS_INPUT_REGISTER 345 1 4 0 0 0 +Status, demand, fan speed (S135) MODBUS_INPUT_REGISTER 346 1 4 0 0 0 +Status, solenoid (S135) MODBUS_INPUT_REGISTER 347 1 4 0 0 0 +Status, compressor, heater(S135) MODBUS_INPUT_REGISTER 348 1 4 0 0 0 +Status, compressor, demand (S135) MODBUS_INPUT_REGISTER 350 1 4 0 0 0 +No. of starts (S135) MODBUS_INPUT_REGISTER 351 1 6 0 9999999 0 +Operating time (S135) MODBUS_INPUT_REGISTER 353 1 h 6 0 9999999 0 +Degree minutes MODBUS_HOLDING_REGISTER 11 10 DM 3 -30000 30000 0 +Blocking (ERS 1) MODBUS_INPUT_REGISTER 358 1 4 0 0 0 +AZ30-EB17 MODBUS_INPUT_REGISTER 359 1 4 0 0 0 +Supply line (S135-BT12) MODBUS_INPUT_REGISTER 360 10 °C 2 0 0 0 +Return line (S135-BT13) MODBUS_INPUT_REGISTER 361 10 °C 2 0 0 0 +Evaporator (S135-BT16) MODBUS_INPUT_REGISTER 362 10 °C 2 0 0 0 +Defrosting sensor (S135-BT76) MODBUS_INPUT_REGISTER 363 10 °C 2 0 0 0 +Incoming air (S135-BT77) MODBUS_INPUT_REGISTER 364 10 °C 2 0 0 0 +Alarm number (S135) MODBUS_INPUT_REGISTER 365 1 5 0 0 0 +Defrosting (S135) MODBUS_INPUT_REGISTER 366 1 4 0 0 0 +Status, relay 5 (S135) MODBUS_INPUT_REGISTER 367 1 4 0 0 0 +Status, relay 4 (S135) MODBUS_INPUT_REGISTER 368 1 4 0 0 0 +Status, relay 3 (S135) MODBUS_INPUT_REGISTER 369 1 4 0 0 0 +Status, relay 2 (S135) MODBUS_INPUT_REGISTER 370 1 4 0 0 0 +Status, relay 1 (S135) MODBUS_INPUT_REGISTER 371 1 4 0 0 0 +Status, relay 0 (S135) MODBUS_INPUT_REGISTER 372 1 4 0 0 0 +Pump speed (S135) MODBUS_INPUT_REGISTER 373 1 % 4 0 0 0 +Selected fan speed MODBUS_INPUT_REGISTER 374 1 % 4 0 0 0 +Version (S135) MODBUS_INPUT_REGISTER 376 1 5 0 0 0 +id:803 MODBUS_INPUT_REGISTER 377 1 6 0 2147483647 0 +id:804 MODBUS_INPUT_REGISTER 379 1 6 0 0 0 +id:805 MODBUS_INPUT_REGISTER 381 1 6 0 2147483647 0 +id:806 MODBUS_INPUT_REGISTER 383 1 6 0 0 0 +Seconds of blank time left, charge pump 1 MODBUS_INPUT_REGISTER 392 1 4 0 0 0 +Seconds of blank time left, charge pump 0 MODBUS_INPUT_REGISTER 393 1 4 0 0 0 +Alarm number from outdoor air heat pump (EB101) MODBUS_INPUT_REGISTER 400 1 4 0 0 0 +Fan speed (EB101) MODBUS_INPUT_REGISTER 401 1 rpm 5 0 0 0 +Max fan speed (EB101) MODBUS_INPUT_REGISTER 402 1 rpm 5 0 0 0 +Min fan speed (EB101) MODBUS_INPUT_REGISTER 403 1 rpm 5 0 0 0 +Max compressor speed (EB101) MODBUS_INPUT_REGISTER 404 10 Hz 5 0 0 0 +Min compressor speed (EB101) MODBUS_INPUT_REGISTER 405 10 Hz 5 0 0 0 +Power (EB101) MODBUS_INPUT_REGISTER 406 10 kW 5 0 0 0 +Time to defrosting (EB101) MODBUS_INPUT_REGISTER 407 1 min 5 0 0 0 +Defrosting index (EB101) MODBUS_INPUT_REGISTER 408 1 5 0 0 0 +Superheat reference EEV (EB101) MODBUS_INPUT_REGISTER 409 10 °C 2 0 0 0 +Superheat EEV (EB101) MODBUS_INPUT_REGISTER 410 10 °C 2 0 0 0 +EEV-ssh-error (EB101) MODBUS_INPUT_REGISTER 411 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB101) MODBUS_INPUT_REGISTER 412 10 °C 2 0 0 0 +Set point value EEV (EB101) MODBUS_INPUT_REGISTER 413 10 °C 2 0 0 0 +EEV PV (EB101) MODBUS_INPUT_REGISTER 414 10 °C 2 0 0 0 +EEV-te-error average open (EB101) MODBUS_INPUT_REGISTER 415 10 °C 2 0 0 0 +Degree of opening EEV (EB101) MODBUS_INPUT_REGISTER 416 1 5 0 0 0 +Superheat reference EVI (EB101) MODBUS_INPUT_REGISTER 417 10 °C 2 0 0 0 +Superheat EVI (EB101) MODBUS_INPUT_REGISTER 418 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB101) MODBUS_INPUT_REGISTER 419 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB101) MODBUS_INPUT_REGISTER 420 10 °C 2 0 0 0 +Set point value EVI (EB101) MODBUS_INPUT_REGISTER 421 10 °C 2 0 0 0 +EVI PV (EB101) MODBUS_INPUT_REGISTER 422 10 °C 2 0 0 0 +EEV-te-error average open in (EVI)(EB101) MODBUS_INPUT_REGISTER 423 10 °C 2 0 0 0 +Degree of opening EVI (EB101) MODBUS_INPUT_REGISTER 424 1 5 0 0 0 +id:859 MODBUS_INPUT_REGISTER 426 10 %RH 2 0 0 0 +id:861 MODBUS_INPUT_REGISTER 427 1 6 0 0 0 +id:862 MODBUS_INPUT_REGISTER 429 1 5 0 0 0 +Low press (EB101 BP8 dew) MODBUS_INPUT_REGISTER 550 10 °C 2 0 0 0 +Hi press (EB101 BP9 dew) MODBUS_INPUT_REGISTER 551 10 °C 2 0 0 0 +Injection (EB101-BT81) MODBUS_INPUT_REGISTER 552 10 °C 2 0 0 0 +Pressure sensor, injection (EB101-BP11) MODBUS_INPUT_REGISTER 553 10 2 0 0 0 +EVI pressure (EB101-EP14-BP11 dew) MODBUS_INPUT_REGISTER 554 10 °C 2 0 0 0 +Evaporator (EB101-BT84) MODBUS_INPUT_REGISTER 555 10 °C 2 0 0 0 +Fan status (EB101-EP14) MODBUS_INPUT_REGISTER 556 1 4 0 0 0 +Fan rpm (EB101-EP14) MODBUS_INPUT_REGISTER 557 1 rpm 5 0 0 0 +High condenser out alarm (S135) MODBUS_INPUT_REGISTER 575 1 5 0 0 0 +High condenser in alarm (S135) MODBUS_INPUT_REGISTER 576 1 5 0 0 0 +Average current (EME 10) MODBUS_INPUT_REGISTER 578 10 A 2 0 0 0 +Operating mode PV panels MODBUS_INPUT_REGISTER 579 1 4 0 0 0 +EME lux mode without EME MODBUS_INPUT_REGISTER 581 1 4 0 0 0 +Timer (EME) MODBUS_INPUT_REGISTER 582 60 min 5 0 0 0 +Fan mode 4 MODBUS_INPUT_REGISTER 590 1 % 4 0 0 0 +Fan mode 3 MODBUS_INPUT_REGISTER 591 1 % 4 0 0 0 +Fan mode 2 MODBUS_INPUT_REGISTER 592 1 % 4 0 0 0 +Is the compressor accessible MODBUS_INPUT_REGISTER 593 1 4 0 0 0 +Prio, hot water (OPT) MODBUS_INPUT_REGISTER 604 1 4 0 0 0 +Permit (undefined) MODBUS_INPUT_REGISTER 683 1 4 0 0 0 +Permit (undefined) MODBUS_INPUT_REGISTER 684 1 4 0 0 0 +Permit (undefined) MODBUS_INPUT_REGISTER 685 1 4 0 0 0 +Permit (OPT 10) additional heat MODBUS_INPUT_REGISTER 686 1 4 0 0 0 +Permit ext. imm. heater step MODBUS_INPUT_REGISTER 687 1 4 0 0 0 +Permit int. imm. heater step MODBUS_INPUT_REGISTER 688 1 4 0 0 0 +Permit shunted additional heat MODBUS_INPUT_REGISTER 689 1 4 0 0 0 +Permit prioritised additional heat MODBUS_INPUT_REGISTER 690 1 4 0 0 0 +Permit (EB108-EP15) MODBUS_INPUT_REGISTER 691 1 4 0 0 0 +Permit (EB107-EP15) MODBUS_INPUT_REGISTER 692 1 4 0 0 0 +Permit (EB106-EP15) MODBUS_INPUT_REGISTER 693 1 4 0 0 0 +Permit (EB105-EP15) MODBUS_INPUT_REGISTER 694 1 4 0 0 0 +Permit (EB104-EP15) MODBUS_INPUT_REGISTER 695 1 4 0 0 0 +Permit (EB103-EP15) MODBUS_INPUT_REGISTER 696 1 4 0 0 0 +Permit (EB102-EP15) MODBUS_INPUT_REGISTER 697 1 4 0 0 0 +Permit (EB101-EP15) MODBUS_INPUT_REGISTER 698 1 4 0 0 0 +Permit (EB100-EP15) MODBUS_INPUT_REGISTER 699 1 4 0 0 0 +Permit (EB108-EP14) MODBUS_INPUT_REGISTER 700 1 4 0 0 0 +Permit (EB107-EP14) MODBUS_INPUT_REGISTER 701 1 4 0 0 0 +Permit (EB106-EP14) MODBUS_INPUT_REGISTER 702 1 4 0 0 0 +Permit (EB105-EP14) MODBUS_INPUT_REGISTER 703 1 4 0 0 0 +Permit (EB104-EP14) MODBUS_INPUT_REGISTER 704 1 4 0 0 0 +Permit (EB103-EP14) MODBUS_INPUT_REGISTER 705 1 4 0 0 0 +Permit (EB102-EP14) MODBUS_INPUT_REGISTER 706 1 4 0 0 0 +Permit (EB101-EP14) MODBUS_INPUT_REGISTER 707 1 4 0 0 0 +Permit (EB100-EP14) MODBUS_INPUT_REGISTER 708 1 4 0 0 0 +Smart energy source, priority 7, start DM MODBUS_INPUT_REGISTER 709 1 3 0 0 0 +Smart energy source, priority 6, start DM MODBUS_INPUT_REGISTER 711 1 3 0 0 0 +Smart energy source, priority 5, start DM MODBUS_INPUT_REGISTER 713 1 3 0 0 0 +Smart energy source, priority 4, start DM MODBUS_INPUT_REGISTER 715 1 3 0 0 0 +Smart energy source, priority 3, start DM MODBUS_INPUT_REGISTER 717 1 3 0 0 0 +Smart energy source, priority 2, start DM MODBUS_INPUT_REGISTER 719 1 3 0 0 0 +Smart energy source, priority 1, start DM MODBUS_INPUT_REGISTER 721 1 3 0 0 0 +Smart energy source, priority 7, stop DM MODBUS_INPUT_REGISTER 723 1 3 0 0 0 +Smart energy source, priority 6, stop DM MODBUS_INPUT_REGISTER 725 1 3 0 0 0 +Smart energy source, priority 5, stop DM MODBUS_INPUT_REGISTER 727 1 3 0 0 0 +Smart energy source, priority 4, stop DM MODBUS_INPUT_REGISTER 729 1 3 0 0 0 +Smart energy source, priority 3, stop DM MODBUS_INPUT_REGISTER 731 1 3 0 0 0 +Smart energy source, priority 2, stop DM MODBUS_INPUT_REGISTER 733 1 3 0 0 0 +Smart energy source, priority 1, stop DM MODBUS_INPUT_REGISTER 735 1 3 0 0 0 +Smart energy source, DM minimum value MODBUS_INPUT_REGISTER 737 1 3 0 0 0 +External guide status MODBUS_INPUT_REGISTER 745 1 4 0 0 0 +Test guide value MODBUS_INPUT_REGISTER 746 1 5 0 0 0 +Temp. lux forces start of hot water demand MODBUS_INPUT_REGISTER 747 1 4 0 0 0 +Smart energy source, prio OPT10 for hot water MODBUS_INPUT_REGISTER 757 1 4 0 0 0 +Smart energy source, Permit OPT to produce hot water MODBUS_INPUT_REGISTER 758 1 4 0 0 0 +Wood boiler activated MODBUS_INPUT_REGISTER 759 1 4 0 0 0 +Time to defrosting (EB108) MODBUS_INPUT_REGISTER 767 1 min 5 0 0 0 +Time to defrosting (EB107) MODBUS_INPUT_REGISTER 792 1 min 5 0 0 0 +Time to defrosting (EB106) MODBUS_INPUT_REGISTER 817 1 min 5 0 0 0 +Time to defrosting (EB105) MODBUS_INPUT_REGISTER 842 1 min 5 0 0 0 +Time to defrosting (EB104) MODBUS_INPUT_REGISTER 867 1 min 5 0 0 0 +Time to defrosting (EB103) MODBUS_INPUT_REGISTER 892 1 min 5 0 0 0 +Time to defrosting (EB102) MODBUS_INPUT_REGISTER 917 1 min 5 0 0 0 +Alarm number (EB100) MODBUS_INPUT_REGISTER 935 1 4 0 0 0 +Fan speed (EB100) MODBUS_INPUT_REGISTER 936 1 rpm 5 0 0 0 +Max fan speed (EB100) MODBUS_INPUT_REGISTER 937 1 rpm 5 0 0 0 +Min fan speed (EB100) MODBUS_INPUT_REGISTER 938 1 rpm 5 0 0 0 +Max compressor speed (EB100) MODBUS_INPUT_REGISTER 939 10 Hz 5 0 0 0 +Min compressor speed (EB100) MODBUS_INPUT_REGISTER 940 10 Hz 5 0 0 0 +Power (EB100) MODBUS_INPUT_REGISTER 941 10 kW 5 0 0 0 +Time to defrosting (EB100) MODBUS_INPUT_REGISTER 942 1 min 5 0 0 0 +Defrosting index (EB100) MODBUS_INPUT_REGISTER 943 1 5 0 0 0 +Superheat reference (EEV)(EB100) MODBUS_INPUT_REGISTER 944 10 °C 2 0 0 0 +Superheat EEV (EB100) MODBUS_INPUT_REGISTER 945 10 °C 2 0 0 0 +EEV-ssh-error EB100) MODBUS_INPUT_REGISTER 946 10 °C 2 0 0 0 +Superheat temp. reference (EEV)(EB100) MODBUS_INPUT_REGISTER 947 10 °C 2 0 0 0 +Set point value EEV (EB100) MODBUS_INPUT_REGISTER 948 10 °C 2 0 0 0 +EEV PV (EB100) MODBUS_INPUT_REGISTER 949 10 °C 2 0 0 0 +EEV-te-error average open (EB100) MODBUS_INPUT_REGISTER 950 10 °C 2 0 0 0 +Opening degree EEV (EB100) MODBUS_INPUT_REGISTER 951 1 5 0 0 0 +Superheat reference EVI (EB100) MODBUS_INPUT_REGISTER 952 10 °C 2 0 0 0 +Superheat EVI (EB100) MODBUS_INPUT_REGISTER 953 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB100) MODBUS_INPUT_REGISTER 954 10 °C 2 0 0 0 +Superheat temp. reference (EVI)(EB100) MODBUS_INPUT_REGISTER 955 10 °C 2 0 0 0 +Set point value EVI (EB100) MODBUS_INPUT_REGISTER 956 10 °C 2 0 0 0 +EVI PV (EB100) MODBUS_INPUT_REGISTER 957 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB100) MODBUS_INPUT_REGISTER 958 10 °C 2 0 0 0 +Opening degree EVI EB100) MODBUS_INPUT_REGISTER 959 1 5 0 0 0 +Wind speed, weather forecast MODBUS_INPUT_REGISTER 960 10 5 0 0 0 +Humidity, weather forecast MODBUS_INPUT_REGISTER 961 10 % 5 0 0 0 +Temperature, weather forecast MODBUS_INPUT_REGISTER 962 10 °C 2 0 0 0 +Temperature, weather data (forecast) MODBUS_INPUT_REGISTER 963 10 °C 2 0 0 0 +Smart energy source, priority select. in hot water MODBUS_INPUT_REGISTER 991 1 4 0 0 0 +Outd. air heat pump, inverter, limits MODBUS_INPUT_REGISTER 992 1 4 0 0 0 +Outd. air heat pump, inverter, speed reducing MODBUS_INPUT_REGISTER 993 1 4 0 0 0 +Has one phase (EB101) MODBUS_INPUT_REGISTER 1008 1 4 0 0 0 +Serial index (EB101) MODBUS_INPUT_REGISTER 1009 1 4 0 0 0 +Serial index (EB100) MODBUS_INPUT_REGISTER 1011 1 4 0 0 0 +Alarm incompatible (heat pump) MODBUS_INPUT_REGISTER 1012 1 5 0 0 0 +Limit DM MODBUS_HOLDING_REGISTER 18 10 DM 2 -30000 30000 0 +Calculated supply climate system 1 MODBUS_INPUT_REGISTER 1017 10 °C 2 0 0 0 +Class 1 alarm MODBUS_INPUT_REGISTER 2195 1 4 0 0 0 +Frost protection status MODBUS_INPUT_REGISTER 1018 1 5 0 0 0 +Cooling status MODBUS_INPUT_REGISTER 1019 1 4 0 0 0 +id:1726 MODBUS_HOLDING_REGISTER 2757 1 2 0 30000 0 +Total run time additional heat MODBUS_INPUT_REGISTER 1025 10 h 3 0 1000000 0 +Power internal additional heat MODBUS_INPUT_REGISTER 1027 100 kW 2 0 0 0 +id:1757 MODBUS_HOLDING_REGISTER 2758 1 4 0 1 0 +Priority MODBUS_INPUT_REGISTER 1028 1 4 0 0 0 +Operating mode internal add. heat MODBUS_INPUT_REGISTER 1029 1 4 0 0 0 +Oper. mode shunt climate system 4 MODBUS_INPUT_REGISTER 1030 1 4 0 0 0 +Oper. mode shunt climate system 3 MODBUS_INPUT_REGISTER 1031 1 4 0 0 0 +Oper. mode shunt climate system 2 MODBUS_INPUT_REGISTER 1032 1 4 0 0 0 +Oper. mode shunt climate system 1 MODBUS_INPUT_REGISTER 1033 1 4 0 0 0 +Operating. mode shunt controlled additional heat MODBUS_INPUT_REGISTER 1034 1 4 0 0 0 +Fan mode 1 MODBUS_INPUT_REGISTER 1037 1 % 4 0 0 0 +Current hot water mode MODBUS_INPUT_REGISTER 1038 1 1 0 0 0 +Blocking cooling MODBUS_INPUT_REGISTER 1053 1 4 0 0 0 +External adjustment climate system 4 MODBUS_INPUT_REGISTER 1054 1 4 0 0 0 +External adjustment climate system 3 MODBUS_INPUT_REGISTER 1055 1 4 0 0 0 +External adjustment climate system 2 MODBUS_INPUT_REGISTER 1056 1 4 0 0 0 +External adjustment climate system 1 MODBUS_INPUT_REGISTER 1057 1 4 0 0 0 +External blocking MODBUS_INPUT_REGISTER 1058 1 4 0 0 0 +Step controlled add. heat blocking MODBUS_INPUT_REGISTER 1062 1 4 0 0 0 +Total HW run time additional heat MODBUS_INPUT_REGISTER 1069 10 h 3 0 9999999 0 +More hot water status MODBUS_INPUT_REGISTER 1078 1 4 0 0 0 +Holiday function status MODBUS_HOLDING_REGISTER 19 1 1 0 0 0 +Heating medium pump speed (GP1) MODBUS_INPUT_REGISTER 1102 1 % 4 0 0 0 +Docked compressors heating MODBUS_INPUT_REGISTER 1108 1 4 0 0 0 +Docked compressors hot water MODBUS_INPUT_REGISTER 1109 1 4 0 0 0 +Docked compressors pool 1 MODBUS_INPUT_REGISTER 1110 1 4 0 0 0 +Reversing valve hot water (QN10) MODBUS_INPUT_REGISTER 2196 1 4 0 0 0 +Operating mode step controlled additional heat MODBUS_INPUT_REGISTER 1115 1 4 0 0 0 +Relay status, base board (EB100-EP14) MODBUS_INPUT_REGISTER 1117 1 4 0 0 0 +Relay status, imm. heat. board (EB100-EP14) MODBUS_INPUT_REGISTER 1119 1 4 0 0 0 +Current status MODBUS_INPUT_REGISTER 1120 1 6 0 0 0 +Functionality, heat pump (EP14) MODBUS_INPUT_REGISTER 1122 1 6 0 0 0 +Active heat pumps MODBUS_INPUT_REGISTER 1124 1 5 0 0 0 +Functionality, heat pump (EP15) MODBUS_INPUT_REGISTER 1125 1 6 0 0 0 +Operating mode HW comfort MODBUS_INPUT_REGISTER 1129 1 4 0 0 0 +Operating mode HW comfort additional heat MODBUS_INPUT_REGISTER 1130 1 4 0 0 0 +Blocked MODBUS_INPUT_REGISTER 1132 1 4 0 0 0 +Pool 1 (QN19) MODBUS_INPUT_REGISTER 1134 1 4 0 0 0 +Version (EB101) MODBUS_INPUT_REGISTER 1451 1 5 0 0 0 +Heat pump type (EB101) MODBUS_INPUT_REGISTER 1452 1 4 0 0 0 +Compressor size (EB101) MODBUS_INPUT_REGISTER 1453 1 4 0 0 0 +Return line (EB101-BT3) MODBUS_INPUT_REGISTER 1475 10 °C 2 0 0 0 +Supply line (EB101-BT12) MODBUS_INPUT_REGISTER 1478 10 °C 2 0 0 0 +Discharge (EB101-BT14) MODBUS_INPUT_REGISTER 1479 10 °C 2 0 0 0 +Liquid line (EB101-BT15) MODBUS_INPUT_REGISTER 1480 10 °C 2 0 0 0 +Suction gas (EB101-BT17) MODBUS_INPUT_REGISTER 1481 10 °C 2 0 0 0 +Compressor, time to start (EB101-EP14) MODBUS_INPUT_REGISTER 1485 1 min 4 0 0 0 +Compressor, number of starts (EB101-EP14) MODBUS_INPUT_REGISTER 1489 1 6 -2147483648 2147483647 0 +Compressor, oper. time, total (EB101-EP14) MODBUS_INPUT_REGISTER 1491 1 h 6 -2147483648 2147483647 0 +Compressor, oper. time, hot water (EB101-EP14) MODBUS_INPUT_REGISTER 1493 1 h 6 -2147483648 2147483647 0 +Alarm number (EB101-EP14) MODBUS_INPUT_REGISTER 1495 1 5 0 0 0 +Heat pump type (EB100) MODBUS_INPUT_REGISTER 1497 1 4 0 0 0 +Compressor size (EB100) MODBUS_INPUT_REGISTER 1498 1 4 0 0 0 +Compressor, requested (EB101-EP14) MODBUS_INPUT_REGISTER 1556 1 4 0 0 0 +Cooling blocking MODBUS_INPUT_REGISTER 1559 1 4 0 0 0 +Date, periodic hot water MODBUS_INPUT_REGISTER 1561 1 - - - - +Blocked compressors MODBUS_INPUT_REGISTER 2174 1 6 0 0 0 +Cooling degree minutes MODBUS_HOLDING_REGISTER 20 10 DM 2 -30000 30000 0 +Hot water, including int. add. heat MODBUS_INPUT_REGISTER 1575 10 kWh 6 0 9999999 0 +Heating, including int. add. heat MODBUS_INPUT_REGISTER 1577 10 kWh 6 0 9999999 0 +Hot water, compressor only MODBUS_INPUT_REGISTER 1583 10 kWh 6 0 9999999 0 +Heating, compressor only MODBUS_INPUT_REGISTER 1585 10 kWh 6 0 9999999 0 +id:2728 MODBUS_HOLDING_REGISTER 3099 1 3 0 9999999 0 +Speed (GP12) MODBUS_INPUT_REGISTER 1589 1 % 4 0 0 0 +Cooling pump manual speed MODBUS_HOLDING_REGISTER 21 1 % 1 1 100 70 +Outdoor temperature (EB101-BT28) MODBUS_INPUT_REGISTER 1621 10 °C 2 0 0 0 +Evaporator (EB101-BT16) MODBUS_INPUT_REGISTER 1622 10 °C 2 0 0 0 +Heating medium pump speed (GP1) MODBUS_INPUT_REGISTER 1636 1 % 4 0 0 0 +id:2793 MODBUS_INPUT_REGISTER 1637 1 % 4 0 0 0 +Frost protection heat exchanger heat pump 1 MODBUS_INPUT_REGISTER 1638 1 4 0 0 0 +Operating mode extra additional heat MODBUS_INPUT_REGISTER 1693 1 4 0 0 0 +Docked compressors cooling MODBUS_INPUT_REGISTER 1694 1 4 0 0 0 +BP4, unprocessed (EB101-EP14) MODBUS_INPUT_REGISTER 1800 1 2 0 0 0 +Low pressure (EB101-BP8) MODBUS_INPUT_REGISTER 1802 10 bar 2 0 0 0 +Current compressor frequency (EB101) MODBUS_INPUT_REGISTER 1803 10 Hz 2 0 0 0 +Protection mode (EB101) MODBUS_INPUT_REGISTER 1804 1 5 0 0 0 +Defrosting (EB101) MODBUS_INPUT_REGISTER 1805 1 4 0 0 0 +Power (EB101-EP14) MODBUS_INPUT_REGISTER 1806 1 kW 4 0 0 0 +Internal charge pump (GP12) MODBUS_INPUT_REGISTER 1822 1 4 0 0 0 +Climate system 4 MODBUS_INPUT_REGISTER 1823 1 4 0 0 0 +Climate system 3 MODBUS_INPUT_REGISTER 1824 1 4 0 0 0 +Climate system 2 MODBUS_INPUT_REGISTER 1825 1 4 0 0 0 +Climate system 1 (HMP) MODBUS_INPUT_REGISTER 1826 1 4 0 0 0 +Pool 1 pump status MODBUS_INPUT_REGISTER 1828 1 4 0 0 0 +Requested compressor frequency (EB101) MODBUS_INPUT_REGISTER 1854 1 Hz 4 0 0 0 +Low press. sensor, unprocessed (EB101-EP14) MODBUS_INPUT_REGISTER 1902 1 2 0 0 0 +Current sensor (EB101-EP14) MODBUS_INPUT_REGISTER 1903 10 A 2 0 0 0 +Operating mode (SG Ready) MODBUS_INPUT_REGISTER 1911 1 4 0 0 0 +SG ready, input A MODBUS_INPUT_REGISTER 1912 1 4 0 0 0 +SG ready, input B MODBUS_INPUT_REGISTER 1913 1 4 0 0 0 +Heating offset (SPA) MODBUS_INPUT_REGISTER 1914 10 1 0 0 0 +Hot water comfort mode (SPA) MODBUS_INPUT_REGISTER 1915 1 1 0 0 0 +Pool offset (SPA) MODBUS_INPUT_REGISTER 1916 1 1 0 0 0 +Cooling offset (SPA) MODBUS_INPUT_REGISTER 1917 1 1 0 0 0 +Operating mode (Smart Price Adaption) MODBUS_INPUT_REGISTER 1918 1 4 0 0 0 +Evaporator 2 (EB101-EP14-BT16) MODBUS_INPUT_REGISTER 1966 10 °C 2 0 0 0 +Temperature, inverter (EB101-EP14) MODBUS_INPUT_REGISTER 1967 10 °C 2 0 0 0 +fan speed (EB101-EP14) MODBUS_INPUT_REGISTER 1968 1 4 0 0 0 +Evaporator 2 (EB100-EP15-BT16) MODBUS_INPUT_REGISTER 1969 10 °C 2 0 0 0 +Temperature, inverter (EB100-EP15) MODBUS_INPUT_REGISTER 1970 10 °C 2 0 0 0 +fan speed (EB100-EP15) MODBUS_INPUT_REGISTER 1971 1 4 0 0 0 +Evaporator 2 (EB100-EP14-BT16) MODBUS_INPUT_REGISTER 1972 10 °C 2 0 0 0 +Temperature, inverter (EB100-EP14) MODBUS_INPUT_REGISTER 1973 10 °C 2 0 0 0 +fan speed (EB100-EP14) MODBUS_INPUT_REGISTER 1974 1 4 0 0 0 +Alarm number MODBUS_INPUT_REGISTER 1975 1 2 0 0 0 +Reset alarm MODBUS_HOLDING_REGISTER 22 1 4 0 0 0 +Non module-specific alarm numbers MODBUS_INPUT_REGISTER 1976 1 2 0 0 0 +Heating curve climate system 1 MODBUS_HOLDING_REGISTER 26 1 1 0 15 9 +Heating offset climate system 1 MODBUS_HOLDING_REGISTER 30 1 1 -10 10 0 +Min supply climate system 1 MODBUS_HOLDING_REGISTER 34 10 °C 2 50 800 200 +Max supply climate system 1 MODBUS_HOLDING_REGISTER 38 10 °C 2 50 800 600 +Own curve, heating P7 MODBUS_HOLDING_REGISTER 39 1 °C 1 5 80 15 +Own curve, heating P6 MODBUS_HOLDING_REGISTER 40 1 °C 1 5 80 15 +Own curve, heating P5 MODBUS_HOLDING_REGISTER 41 1 °C 1 5 80 26 +Own curve, heating P4 MODBUS_HOLDING_REGISTER 42 1 °C 1 5 80 32 +Own curve, heating P3 MODBUS_HOLDING_REGISTER 43 1 °C 1 5 80 35 +Own curve, heating P2 MODBUS_HOLDING_REGISTER 44 1 °C 1 5 80 40 +Own curve, heating P1 MODBUS_HOLDING_REGISTER 45 1 °C 1 5 80 45 +Point offset outdoor temperature MODBUS_HOLDING_REGISTER 46 1 °C 1 -40 30 0 +Point offset MODBUS_HOLDING_REGISTER 47 1 °C 1 -10 10 0 +External adjustment climate system 1 MODBUS_HOLDING_REGISTER 51 1 1 -10 10 0 +External adjustment with room sensor climate system 1 MODBUS_HOLDING_REGISTER 55 10 °C 2 50 300 200 +Hot water demand mode MODBUS_HOLDING_REGISTER 56 1 1 0 4 1 +Start temperature HW high temperature MODBUS_HOLDING_REGISTER 58 10 °C 2 50 700 530 +Start temperature HW normal temperature MODBUS_HOLDING_REGISTER 59 10 °C 2 50 700 480 +Start temperature HW low temperature MODBUS_HOLDING_REGISTER 60 10 °C 2 50 700 430 +Stop temperature HW periodic increase MODBUS_HOLDING_REGISTER 61 10 °C 2 550 700 550 +Stop temperature HW high temperature MODBUS_HOLDING_REGISTER 62 10 °C 2 50 700 550 +Stop temperature HW normal temperature MODBUS_HOLDING_REGISTER 63 10 °C 2 50 700 510 +Stop temperature HW low temperature MODBUS_HOLDING_REGISTER 64 10 °C 2 50 700 480 +Periodic hot water MODBUS_HOLDING_REGISTER 65 1 1 0 1 1 +Periodic hot water interval MODBUS_HOLDING_REGISTER 66 1 days 1 1 90 7 +Start time periodic hot water MODBUS_HOLDING_REGISTER 67 1 - - - - +Language MODBUS_HOLDING_REGISTER 91 1 1 0 22 0 +Period time hot water MODBUS_HOLDING_REGISTER 92 1 min 4 0 180 30 +Period time heating MODBUS_HOLDING_REGISTER 93 1 min 4 0 180 30 +Operating mode MODBUS_HOLDING_REGISTER 2743 1 4 0 2 0 +Operating mode heating medium pump MODBUS_HOLDING_REGISTER 95 1 4 10 40 40 +Activate force control MODBUS_HOLDING_REGISTER 5000 1 4 0 0 0 +Max. internal additional heat MODBUS_HOLDING_REGISTER 102 100 kW 2 0 4500 900 +Fuse MODBUS_HOLDING_REGISTER 103 1 A 5 1 400 16 +id:3826 MODBUS_HOLDING_REGISTER 2747 1 4 1 128 4 +id:3827 MODBUS_HOLDING_REGISTER 2746 1 4 1 128 2 +id:3828 MODBUS_HOLDING_REGISTER 2745 1 4 1 128 1 +Floor drying MODBUS_HOLDING_REGISTER 120 1 4 0 1 0 +Floor drying period 7 MODBUS_HOLDING_REGISTER 121 1 days 4 0 30 2 +Floor drying period 6 MODBUS_HOLDING_REGISTER 122 1 days 4 0 30 2 +Floor drying period 5 MODBUS_HOLDING_REGISTER 123 1 days 4 0 30 2 +Floor drying period 4 MODBUS_HOLDING_REGISTER 124 1 days 4 0 30 3 +Floor drying period 3 MODBUS_HOLDING_REGISTER 125 1 days 4 0 30 2 +Floor drying period 2 MODBUS_HOLDING_REGISTER 126 1 days 4 0 30 2 +Floor drying period 1 MODBUS_HOLDING_REGISTER 127 1 days 4 0 30 2 +Floor drying temp. 7 MODBUS_HOLDING_REGISTER 128 1 °C 4 15 70 20 +Floor drying temp. 6 MODBUS_HOLDING_REGISTER 129 1 °C 4 15 70 30 +Floor drying temp. 5 MODBUS_HOLDING_REGISTER 130 1 °C 4 15 70 40 +Floor drying temp. 4 MODBUS_HOLDING_REGISTER 131 1 °C 4 15 70 45 +Floor drying temp. 3 MODBUS_HOLDING_REGISTER 132 1 °C 4 15 70 40 +Floor drying temp. 2 MODBUS_HOLDING_REGISTER 133 1 °C 4 15 70 30 +Floor drying temp. 1 MODBUS_HOLDING_REGISTER 134 1 °C 4 15 70 20 +Floor drying ongoing time. MODBUS_INPUT_REGISTER 1977 1 5 0 10000 0 +Dimensioned outdoor temperature MODBUS_HOLDING_REGISTER 140 10 °C 2 -400 200 -180 +Delta T for DOT MODBUS_HOLDING_REGISTER 141 10 °C 2 10 250 100 +Climate system 2 MODBUS_HOLDING_REGISTER 142 1 4 0 1 0 +Climate system 3 MODBUS_HOLDING_REGISTER 143 1 4 0 1 0 +Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0 +Shunt controlled additional heat MODBUS_HOLDING_REGISTER 153 1 4 0 1 0 +Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30 +Step controlled additional heat accessory MODBUS_HOLDING_REGISTER 158 1 4 0 1 0 +DM start step controlled additional heat MODBUS_HOLDING_REGISTER 159 1 DM 2 -2000 -30 -400 +Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2 +Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10 +Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30 +Cooling with room sensors MODBUS_HOLDING_REGISTER 170 10 4 0 41 0 +Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 30 +Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1 +Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1 +Permit cooling MODBUS_HOLDING_REGISTER 182 1 4 0 1 1 +Auto mode, start temperature for cooling MODBUS_HOLDING_REGISTER 183 10 °C 2 150 400 250 +Auto mode, stop temperature for heating MODBUS_HOLDING_REGISTER 184 10 °C 2 -200 400 170 +Auto mode, additional heat stop temperature MODBUS_HOLDING_REGISTER 185 10 °C 2 -250 400 50 +Auto mode filter time MODBUS_HOLDING_REGISTER 186 1 h 4 0 48 24 +Max difference supply, compressor MODBUS_HOLDING_REGISTER 187 10 °C 2 10 250 100 +Max difference supply, additional heat MODBUS_HOLDING_REGISTER 188 10 °C 2 10 240 70 +Time format MODBUS_HOLDING_REGISTER 194 1 4 0 1 1 +Alarm action, lower room temperature MODBUS_HOLDING_REGISTER 196 1 4 0 1 0 +Alarm action lower HW temperature MODBUS_HOLDING_REGISTER 197 1 4 0 1 1 +Auxiliary operation on alarm MODBUS_HOLDING_REGISTER 198 1 4 0 0 0 +Use room sensor climate system 4 MODBUS_HOLDING_REGISTER 199 1 4 0 1 0 +Use room sensor climate system 3 MODBUS_HOLDING_REGISTER 200 1 4 0 1 0 +Use room sensor climate system 2 MODBUS_HOLDING_REGISTER 201 1 4 0 1 0 +Use room sensor climate system 1 MODBUS_HOLDING_REGISTER 202 1 4 0 1 0 +Room sensor set point value climate system 4 MODBUS_HOLDING_REGISTER 203 10 °C 2 50 300 200 +Room sensor set point value climate system 3 MODBUS_HOLDING_REGISTER 204 10 °C 2 50 300 200 +Room sensor set point value climate system 2 MODBUS_HOLDING_REGISTER 205 10 °C 2 50 300 200 +Room sensor set point value climate system 1 MODBUS_HOLDING_REGISTER 206 10 °C 2 50 300 200 +Room sensor factor climate system 4 MODBUS_HOLDING_REGISTER 207 10 4 0 60 20 +Room sensor factor climate system 3 MODBUS_HOLDING_REGISTER 208 10 4 0 60 20 +Room sensor factor climate system 2 MODBUS_HOLDING_REGISTER 209 10 4 0 60 20 +Room sensor factor climate system 1 MODBUS_HOLDING_REGISTER 210 10 4 0 60 20 +Input AUX5 MODBUS_HOLDING_REGISTER 211 1 4 0 61 0 +Input AUX4 MODBUS_HOLDING_REGISTER 212 1 4 0 61 0 +Input AUX3 MODBUS_HOLDING_REGISTER 213 1 4 0 61 0 +Input AUX2 MODBUS_HOLDING_REGISTER 214 1 4 0 61 0 +Input AUX1 MODBUS_HOLDING_REGISTER 215 1 4 0 61 0 +Output AUX1 MODBUS_HOLDING_REGISTER 216 1 4 0 26 0 +id:3968 MODBUS_HOLDING_REGISTER 2752 1 5 1 3600 5 +Preset flow setting for climate system MODBUS_HOLDING_REGISTER 223 1 4 0 3 1 +id:3977 MODBUS_HOLDING_REGISTER 2753 1 4 21 22 22 +More hot water MODBUS_HOLDING_REGISTER 225 10 - - - - +id:4050 MODBUS_HOLDING_REGISTER 4046 1 4 0 1 0 +Oper. mode MODBUS_HOLDING_REGISTER 237 1 4 0 0 0 +Cooling heat sensor set point value MODBUS_HOLDING_REGISTER 681 10 2 50 400 210 +Pool 1 accessory MODBUS_HOLDING_REGISTER 685 1 4 0 1 0 +Hot water comfort MODBUS_HOLDING_REGISTER 694 1 4 0 1 0 +More hot water MODBUS_HOLDING_REGISTER 697 1 1 0 0 0 +Start diff. DM, step-controlled add. heat MODBUS_HOLDING_REGISTER 703 1 DM 2 0 2000 400 +HW comfort shunt on/off MODBUS_HOLDING_REGISTER 705 1 4 0 1 0 +External cooling accessory MODBUS_HOLDING_REGISTER 709 1 4 0 1 0 +id:4591 MODBUS_HOLDING_REGISTER 4052 1 1 5 80 30 +Cooling connected, climate system 1 MODBUS_HOLDING_REGISTER 726 1 4 0 0 0 +id:4617 MODBUS_HOLDING_REGISTER 4053 1 1 0 1 0 +Operating mode charge pump climate system 1 MODBUS_HOLDING_REGISTER 748 1 4 0 1 1 +id:4660 MODBUS_HOLDING_REGISTER 4063 1 4 0 1 0 +Shunted brine, accessory MODBUS_HOLDING_REGISTER 4064 1 4 0 1 0 +Shunted brine max. temp. MODBUS_HOLDING_REGISTER 4067 1 °C 4 0 30 20 +Heating (SG Ready) MODBUS_HOLDING_REGISTER 760 1 4 0 1 1 +id:4703 MODBUS_HOLDING_REGISTER 4068 1 4 0 1 0 +id:4704 MODBUS_HOLDING_REGISTER 4069 1 4 0 1 0 +id:4705 MODBUS_HOLDING_REGISTER 4070 1 4 0 1 0 +id:4706 MODBUS_HOLDING_REGISTER 4071 1 4 0 1 0 +id:4707 MODBUS_HOLDING_REGISTER 4072 1 4 0 1 0 +id:4708 MODBUS_HOLDING_REGISTER 4073 1 4 0 1 0 +id:4709 MODBUS_HOLDING_REGISTER 4074 1 4 0 1 0 +id:4710 MODBUS_HOLDING_REGISTER 4075 1 4 0 1 0 +id:4711 MODBUS_HOLDING_REGISTER 0 1 4 0 1 0 +Input AUX5 MODBUS_HOLDING_REGISTER 767 1 4 0 61 0 +Operating mode circulation pump heating heat pump 1 MODBUS_HOLDING_REGISTER 783 1 4 0 1 1 +Operating mode circulation pump hot water heat pump 1 MODBUS_HOLDING_REGISTER 799 1 4 0 1 1 +Speed circulation pump waiting mode heat pump 1 MODBUS_HOLDING_REGISTER 841 1 % 4 1 100 30 +Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 1 100 30 +Activated (Smart Price Adaption) MODBUS_HOLDING_REGISTER 843 1 4 0 1 0 +(SPA), cooling activated MODBUS_HOLDING_REGISTER 849 1 4 0 1 1 +(SPA), area MODBUS_HOLDING_REGISTER 851 1 4 0 254 23 +Max. speed controlled charge pump (EB101) MODBUS_HOLDING_REGISTER 867 1 % 4 80 100 100 +External adjustment climate system 8 MODBUS_HOLDING_REGISTER 893 1 1 -10 10 0 +External adjustment climate system 7 MODBUS_HOLDING_REGISTER 894 1 1 -10 10 0 +External adjustment climate system 6 MODBUS_HOLDING_REGISTER 895 1 1 -10 10 0 +External adjustment climate system 5 MODBUS_HOLDING_REGISTER 896 1 1 -10 10 0 +External adjustment with room sensor climate system 8 MODBUS_HOLDING_REGISTER 897 10 °C 2 50 300 200 +External adjustment with room sensor climate system 7 MODBUS_HOLDING_REGISTER 898 10 °C 2 50 300 200 +External adjustment with room sensor climate system 6 MODBUS_HOLDING_REGISTER 899 10 °C 2 50 300 200 +External adjustment with room sensor climate system 5 MODBUS_HOLDING_REGISTER 900 10 °C 2 50 300 200 +Climate system 5 MODBUS_HOLDING_REGISTER 905 1 4 0 1 0 +Climate system 6 MODBUS_HOLDING_REGISTER 906 1 4 0 1 0 +Climate system 7 MODBUS_HOLDING_REGISTER 907 1 4 0 1 0 +Climate system 8 MODBUS_HOLDING_REGISTER 908 1 4 0 1 0 +Heating connected, climate system 1 MODBUS_HOLDING_REGISTER 932 1 4 0 1 1 +ERS 1 MODBUS_HOLDING_REGISTER 933 1 4 0 1 0 +id:4969 MODBUS_HOLDING_REGISTER 4091 1 4 0 1 0 +id:4970 MODBUS_HOLDING_REGISTER 4092 1 4 0 1 0 +id:4971 MODBUS_HOLDING_REGISTER 4093 1 Hz 4 20 117 20 +id:4972 MODBUS_HOLDING_REGISTER 4094 1 Hz 4 20 117 20 +id:4973 MODBUS_HOLDING_REGISTER 4095 1 Hz 4 23 120 23 +id:4974 MODBUS_HOLDING_REGISTER 4096 1 Hz 4 23 120 23 +Use room sensor climate system 8 MODBUS_HOLDING_REGISTER 948 1 4 0 1 0 +Use room sensor climate system 7 MODBUS_HOLDING_REGISTER 949 1 4 0 1 0 +Use room sensor climate system 6 MODBUS_HOLDING_REGISTER 950 1 4 0 1 0 +Use room sensor climate system 5 MODBUS_HOLDING_REGISTER 951 1 4 0 1 0 +Room sensor set point value climate system 8 MODBUS_HOLDING_REGISTER 952 10 °C 2 50 300 200 +Room sensor set point value climate system 7 MODBUS_HOLDING_REGISTER 953 10 °C 2 50 300 200 +Room sensor set point value climate system 6 MODBUS_HOLDING_REGISTER 954 10 °C 2 50 300 200 +Room sensor set point value climate system 5 MODBUS_HOLDING_REGISTER 955 10 °C 2 50 300 200 +Room sensor factor climate system 8 MODBUS_HOLDING_REGISTER 956 10 4 0 60 20 +Room sensor factor climate system 7 MODBUS_HOLDING_REGISTER 957 10 4 0 60 20 +Room sensor factor climate system 6 MODBUS_HOLDING_REGISTER 958 10 4 0 60 20 +Room sensor factor climate system 5 MODBUS_HOLDING_REGISTER 959 10 4 0 60 20 +Current transformer ratio MODBUS_HOLDING_REGISTER 980 1 5 300 3000 300 +Room sensor set point value climate system 8, cooling MODBUS_HOLDING_REGISTER 981 10 °C 2 50 350 250 +Room sensor set point value climate system 7, cooling MODBUS_HOLDING_REGISTER 982 10 °C 2 50 350 250 +Room sensor set point value climate system 6, cooling MODBUS_HOLDING_REGISTER 983 10 °C 2 50 350 250 +Room sensor set point value climate system 5, cooling MODBUS_HOLDING_REGISTER 984 10 °C 2 50 350 250 +Room sensor set point value climate system 4, cooling MODBUS_HOLDING_REGISTER 985 10 °C 2 50 350 250 +Room sensor set point value climate system 3, cooling MODBUS_HOLDING_REGISTER 986 10 °C 2 50 350 250 +Room sensor set point value climate system 2, cooling MODBUS_HOLDING_REGISTER 987 10 °C 2 50 350 250 +Room sensor set point value climate system 1, cooling MODBUS_HOLDING_REGISTER 988 10 °C 2 50 350 250 +Room sensor factor climate system 8, cooling MODBUS_HOLDING_REGISTER 989 10 4 0 60 10 +Room sensor factor climate system 7, cooling MODBUS_HOLDING_REGISTER 990 10 4 0 60 10 +Room sensor factor climate system 6, cooling MODBUS_HOLDING_REGISTER 991 10 4 0 60 10 +Room sensor factor climate system 5, cooling MODBUS_HOLDING_REGISTER 992 10 4 0 60 10 +Room sensor factor climate system 4, cooling MODBUS_HOLDING_REGISTER 993 10 4 0 60 10 +Room sensor factor climate system 3, cooling MODBUS_HOLDING_REGISTER 994 10 4 0 60 10 +Room sensor factor climate system 2, cooling MODBUS_HOLDING_REGISTER 995 10 4 0 60 10 +Room sensor factor climate system 1, cooling MODBUS_HOLDING_REGISTER 996 10 4 0 60 10 +Set point value (RH) MODBUS_HOLDING_REGISTER 997 1 % 1 30 90 60 +HTS 1 MODBUS_HOLDING_REGISTER 998 1 4 0 1 0 +OPT MODBUS_HOLDING_REGISTER 1015 1 4 0 1 0 +DM start difference (OPT) MODBUS_HOLDING_REGISTER 1016 1 DM 2 10 2000 700 +Exhaust air fan speed 4 (ERS 1) MODBUS_HOLDING_REGISTER 1021 1 % 4 0 100 100 +Exhaust air fan speed 3 (ERS 1) MODBUS_HOLDING_REGISTER 1022 1 % 4 0 100 80 +Exhaust air fan speed 2 (ERS 1) MODBUS_HOLDING_REGISTER 1023 1 % 4 0 100 30 +Exhaust air fan speed 1 (ERS 1) MODBUS_HOLDING_REGISTER 1024 1 % 4 0 100 0 +Exhaust air fan speed normal (ERS 1) MODBUS_HOLDING_REGISTER 1025 1 % 4 1 100 75 +S135 MODBUS_HOLDING_REGISTER 1035 1 4 0 1 0 +Pump speed (S135) MODBUS_HOLDING_REGISTER 1036 1 % 4 1 100 70 +Bypass temp. (ERS 1) MODBUS_HOLDING_REGISTER 1044 1 °C 4 2 10 4 +Pool pump type MODBUS_HOLDING_REGISTER 1045 1 4 0 1 1 +External cooling accessory pump type MODBUS_HOLDING_REGISTER 1046 1 4 0 1 1 +Flow sensor activated X22 MODBUS_HOLDING_REGISTER 1049 1 4 0 1 0 +Max. internal additional heat SG Ready MODBUS_HOLDING_REGISTER 1052 100 kW 2 0 900 900 +Hysteresis (OPT) MODBUS_HOLDING_REGISTER 1066 1 2 10 2000 100 +Activated (EME10) MODBUS_HOLDING_REGISTER 1068 1 4 0 1 0 +PV panel affects heating (EME) MODBUS_HOLDING_REGISTER 1069 1 4 0 1 0 +PV panel affects hot water (EME) MODBUS_HOLDING_REGISTER 1070 1 4 0 1 0 +Delay timer EME MODBUS_HOLDING_REGISTER 1071 1 5 0 0 0 +AUX blocking (OPT) MODBUS_HOLDING_REGISTER 1095 1 4 0 0 0 +Outdoor air mixing MODBUS_HOLDING_REGISTER 1096 1 4 0 1 0 +Smart home room control MODBUS_HOLDING_REGISTER 1102 1 4 0 1 0 +Smart Energy Source MODBUS_HOLDING_REGISTER 1105 1 4 0 1 0 +Control method, smart energy source MODBUS_HOLDING_REGISTER 1106 1 4 0 1 0 +El. price, special, smart energy source MODBUS_HOLDING_REGISTER 1107 1 4 0 2 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1108 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1109 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1110 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1111 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1112 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1113 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1114 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1115 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1116 1 5 0 10000 100 +Prim. factor, smart energy source MODBUS_HOLDING_REGISTER 1117 10 4 0 50 25 +Prim. factor, shunt add. heat smart energy source MODBUS_HOLDING_REGISTER 1118 10 4 0 50 10 +Prim. factor, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1119 10 4 0 50 10 +Prim. factor, OPT10 smart energy source MODBUS_HOLDING_REGISTER 1120 10 4 0 50 10 +OPT10, high tariff price smart energy source MODBUS_HOLDING_REGISTER 1121 1 5 1 10000 100 +OPT10, low tariff price smart energy source MODBUS_HOLDING_REGISTER 1122 1 5 1 10000 100 +ext. step add. heat, high tariff price smart energy source MODBUS_HOLDING_REGISTER 1123 1 5 1 10000 100 +ext. step add. heat, low tariff price smart energy source MODBUS_HOLDING_REGISTER 1124 1 5 1 10000 100 +Shunt add. heat, high tariff price smart energy source MODBUS_HOLDING_REGISTER 1125 1 5 1 10000 100 +Shunt add. heat, low tariff price smart energy source MODBUS_HOLDING_REGISTER 1126 1 5 1 10000 100 +El. price, fixed, high tariff smart energy source MODBUS_HOLDING_REGISTER 1127 1 5 1 10000 100 +El. price, fixed, low tariff smart energy source MODBUS_HOLDING_REGISTER 1128 1 5 1 10000 100 +El. price, variable, high tariff smart energy source MODBUS_HOLDING_REGISTER 1129 1 5 1 10000 100 +El. price, variable, low tariff smart energy source MODBUS_HOLDING_REGISTER 1130 1 5 1 10000 100 +DM start source, priority 5 smart energy source MODBUS_HOLDING_REGISTER 1131 1 2 100 2000 400 +DM start source, priority 4 smart energy source MODBUS_HOLDING_REGISTER 1132 1 2 100 2000 400 +DM start source, priority 3 smart energy source MODBUS_HOLDING_REGISTER 1133 1 2 100 2000 400 +DM start source, priority 2 smart energy source MODBUS_HOLDING_REGISTER 1134 1 2 100 2000 400 +DM start source, priority 1 smart energy source MODBUS_HOLDING_REGISTER 1135 1 2 -2000 -10 -60 +Start day, tariff smart energy source MODBUS_HOLDING_REGISTER 1136 1 4 1 31 1 +End day, tariff smart energy source MODBUS_HOLDING_REGISTER 1137 1 4 1 31 31 +Start month, tariff smart energy source MODBUS_HOLDING_REGISTER 1138 1 4 1 12 1 +End month, tariff smart energy source MODBUS_HOLDING_REGISTER 1139 1 4 1 12 12 +Start day, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1172 1 4 1 31 1 +End day, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1173 1 4 1 31 31 +Start month, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1174 1 4 1 12 1 +End month, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1175 1 4 1 12 12 +Start day, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1208 1 4 1 31 1 +End day, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1209 1 4 1 31 31 +Start month, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1210 1 4 1 12 1 +End month, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1211 1 4 1 12 12 +Start day tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1244 1 4 1 31 1 +End day tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1245 1 4 1 31 31 +Start month tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1246 1 4 1 12 1 +End month tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1247 1 4 1 12 12 +Start day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1280 1 4 1 31 1 +End day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1281 1 4 1 31 31 +Start month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1282 1 4 1 12 1 +End month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1283 1 4 1 12 12 +Prioritise additional heat (AXC40) MODBUS_HOLDING_REGISTER 1320 1 4 0 1 0 +Max difference, SES priority 1 energy source MODBUS_HOLDING_REGISTER 1326 10 °C 2 10 250 100 +Max difference, SES lower priority energy source MODBUS_HOLDING_REGISTER 1327 10 °C 2 10 250 70 +Installed (EB101) MODBUS_HOLDING_REGISTER 1550 1 4 0 1 1 +EME20 MODBUS_HOLDING_REGISTER 4000 1 4 0 1 0 +Current power MODBUS_INPUT_REGISTER 2176 1 W 6 0 0 0 +id:6012 MODBUS_HOLDING_REGISTER 4008 1 % 4 1 100 70 +id:6028 MODBUS_INPUT_REGISTER 1993 1 4 0 0 0 +id:6029 MODBUS_INPUT_REGISTER 1994 1 5 0 0 0 +Total average power (EME 20) MODBUS_INPUT_REGISTER 2178 100 kW 6 0 0 0 +Total energy MODBUS_INPUT_REGISTER 2180 10 kWh 3 0 0 0 +ERS 2 MODBUS_HOLDING_REGISTER 4076 1 4 0 1 0 +ERS 3 MODBUS_HOLDING_REGISTER 4077 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 4078 1 4 0 1 0 +id:6486 MODBUS_HOLDING_REGISTER 4135 1 4 0 1 0 +id:6756 MODBUS_INPUT_REGISTER 2004 10 %RH 2 0 0 0 +id:6757 MODBUS_INPUT_REGISTER 2005 10 %RH 2 0 0 0 +id:6758 MODBUS_INPUT_REGISTER 2006 10 %RH 2 0 0 0 +HTS 2 MODBUS_HOLDING_REGISTER 1981 1 4 0 1 0 +HTS 3 MODBUS_HOLDING_REGISTER 1982 1 4 0 1 0 +HTS 4 MODBUS_HOLDING_REGISTER 1983 1 4 0 1 0 +External adjustment, cooling climate system 8 MODBUS_HOLDING_REGISTER 4138 1 1 -10 10 0 +External adjustment, cooling climate system 7 MODBUS_HOLDING_REGISTER 4139 1 1 -10 10 0 +External adjustment, cooling climate system 6 MODBUS_HOLDING_REGISTER 4140 1 1 -10 10 0 +External adjustment, cooling climate system 5 MODBUS_HOLDING_REGISTER 4141 1 1 -10 10 0 +External adjustment, cooling climate system 4 MODBUS_HOLDING_REGISTER 4142 1 1 -10 10 0 +External adjustment, cooling climate system 3 MODBUS_HOLDING_REGISTER 4143 1 1 -10 10 0 +External adjustment, cooling climate system 2 MODBUS_HOLDING_REGISTER 4144 1 1 -10 10 0 +External adjustment, cooling climate system 1 MODBUS_HOLDING_REGISTER 4145 1 1 -10 10 0 +External adjustment with room sensor, cooling climate system 8 MODBUS_HOLDING_REGISTER 4146 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 7 MODBUS_HOLDING_REGISTER 4147 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 6 MODBUS_HOLDING_REGISTER 4148 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 5 MODBUS_HOLDING_REGISTER 4149 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 4 MODBUS_HOLDING_REGISTER 4150 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 3 MODBUS_HOLDING_REGISTER 4151 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 2 MODBUS_HOLDING_REGISTER 4152 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 1 MODBUS_HOLDING_REGISTER 4153 10 °C 2 50 300 200 +Current power MODBUS_INPUT_REGISTER 2177 100 kW 6 0 0 0 +id:6917 MODBUS_HOLDING_REGISTER 4072 1 4 0 200 1 +id:6918 MODBUS_HOLDING_REGISTER 4073 1 4 0 20 1 +id:6920 MODBUS_HOLDING_REGISTER 4074 1 4 0 20 0 +id:6921 MODBUS_HOLDING_REGISTER 4075 1 4 1 100 15 +id:6922 MODBUS_HOLDING_REGISTER 4154 1 4 0 20 3 +id:6923 MODBUS_HOLDING_REGISTER 4155 1 4 0 20 2 +BlockFreq 1 (EB102) MODBUS_HOLDING_REGISTER 4164 1 4 0 1 0 +BlockFreq 1 (EB103) MODBUS_HOLDING_REGISTER 4165 1 4 0 1 0 +BlockFreq 1 (EB104) MODBUS_HOLDING_REGISTER 4166 1 4 0 1 0 +BlockFreq 1 (EB105) MODBUS_HOLDING_REGISTER 4167 1 4 0 1 0 +BlockFreq 1 (EB106) MODBUS_HOLDING_REGISTER 4168 1 4 0 1 0 +BlockFreq 1 (EB107) MODBUS_HOLDING_REGISTER 4169 1 4 0 1 0 +BlockFreq 1 (EB108) MODBUS_HOLDING_REGISTER 4170 1 4 0 1 0 +id:6977 MODBUS_HOLDING_REGISTER 4201 1 4 0 100 0 +Power at DOT, manual value MODBUS_HOLDING_REGISTER 4200 1 4 0 1 0 +Blocking actions (ERS 3) MODBUS_HOLDING_REGISTER 4100 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 4101 1 4 0 2 2 +id:7048 MODBUS_HOLDING_REGISTER 3987 1 4 0 1 0 +id:7138 MODBUS_HOLDING_REGISTER 4009 1 % 4 0 100 70 +id:7139 MODBUS_HOLDING_REGISTER 4010 1 4 0 1 0 +id:7140 MODBUS_HOLDING_REGISTER 4011 1 4 0 1 0 +id:7141 MODBUS_HOLDING_REGISTER 4012 1 % 4 0 100 70 +id:7142 MODBUS_HOLDING_REGISTER 4013 1 4 0 1 0 +id:7143 MODBUS_HOLDING_REGISTER 4014 1 4 0 1 0 +id:7144 MODBUS_HOLDING_REGISTER 4015 1 % 4 0 100 70 +id:7145 MODBUS_HOLDING_REGISTER 4016 1 4 0 1 0 +id:7146 MODBUS_HOLDING_REGISTER 4017 1 4 0 1 0 +id:7147 MODBUS_HOLDING_REGISTER 4018 1 % 4 0 100 70 +id:7148 MODBUS_HOLDING_REGISTER 4019 1 4 0 1 0 +id:7149 MODBUS_HOLDING_REGISTER 4020 1 4 0 1 0 +id:7150 MODBUS_HOLDING_REGISTER 4021 1 % 4 0 100 70 +id:7176 MODBUS_HOLDING_REGISTER 4023 1 4 0 1 0 +id:7179 MODBUS_INPUT_REGISTER 2010 10 °C 2 0 0 0 +Night cooling 1 MODBUS_HOLDING_REGISTER 2955 1 4 0 1 0 +Start temperature night cooling 1 MODBUS_HOLDING_REGISTER 2942 1 °C 4 20 30 25 +Night cooling diff MODBUS_HOLDING_REGISTER 2943 1 °C 4 3 10 6 +id:8002 MODBUS_HOLDING_REGISTER 1996 1 % 4 -15 10 -3 +id:8003 MODBUS_HOLDING_REGISTER 1997 1 % 4 1 254 65 +Minimum permitted speed (EB101 GP12) MODBUS_HOLDING_REGISTER 3243 1 % 4 1 50 1 +Start fan de-icing (EB101) MODBUS_HOLDING_REGISTER 3251 1 1 0 1 0 +id:8060 MODBUS_HOLDING_REGISTER 3259 1 1 0 1 0 +id:8061 MODBUS_HOLDING_REGISTER 3260 1 1 0 1 0 +id:8062 MODBUS_HOLDING_REGISTER 3261 1 1 0 1 0 +id:8063 MODBUS_HOLDING_REGISTER 3262 1 1 0 1 0 +id:8064 MODBUS_HOLDING_REGISTER 3263 1 1 0 1 0 +id:8065 MODBUS_HOLDING_REGISTER 3264 1 1 0 1 0 +id:8066 MODBUS_HOLDING_REGISTER 3265 1 1 0 1 0 +id:8067 MODBUS_HOLDING_REGISTER 3266 1 1 0 1 0 +System 1 (RMU) MODBUS_HOLDING_REGISTER 176 1 4 0 1 0 +System 2 (RMU) MODBUS_HOLDING_REGISTER 177 1 4 0 1 0 +System 3 (RMU) MODBUS_HOLDING_REGISTER 178 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 179 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 1998 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 1999 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 2000 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 2001 1 4 0 1 0 +id:8982 MODBUS_HOLDING_REGISTER 3346 1 4 0 0 0 +The start guide has been run MODBUS_HOLDING_REGISTER 2742 1 4 0 1 1 +Audio signal on alarm MODBUS_HOLDING_REGISTER 3232 1 4 0 1 1 +Sound when pressing button MODBUS_HOLDING_REGISTER 3233 1 4 0 1 1 +BT12 offset, heat pump 1 MODBUS_HOLDING_REGISTER 3234 10 °C 1 -50 50 0 +Heating, auto MODBUS_HOLDING_REGISTER 3059 1 4 0 1 1 +Factor MODBUS_HOLDING_REGISTER 3033 1 4 1 10 5 +id:10881 MODBUS_HOLDING_REGISTER 3062 1 4 0 1 0 +id:10890 MODBUS_HOLDING_REGISTER 3063 1 4 0 1 0 +Hot water start (BT5) MODBUS_INPUT_REGISTER 2014 10 °C 2 0 0 0 +Pump: Heating medium (GP6) MODBUS_INPUT_REGISTER 2128 1 4 0 0 0 +id:12332 MODBUS_HOLDING_REGISTER 2767 1 2 -600 600 -32768 +id:12333 MODBUS_HOLDING_REGISTER 2768 1 2 -600 600 -32768 +id:12334 MODBUS_HOLDING_REGISTER 2769 1 2 -600 600 -32768 +id:12335 MODBUS_HOLDING_REGISTER 2770 1 2 -600 600 -32768 +id:12336 MODBUS_HOLDING_REGISTER 2771 1 2 -600 600 -32768 +id:12337 MODBUS_HOLDING_REGISTER 2772 1 2 -600 600 -32768 +id:12338 MODBUS_HOLDING_REGISTER 2773 1 2 -600 600 -32768 +id:12339 MODBUS_HOLDING_REGISTER 2774 1 2 -600 600 -32768 +id:12340 MODBUS_HOLDING_REGISTER 2775 1 2 -600 600 -32768 +id:12341 MODBUS_HOLDING_REGISTER 2776 1 2 -600 600 -32768 +id:12342 MODBUS_HOLDING_REGISTER 2777 1 2 -600 600 -32768 +id:12343 MODBUS_HOLDING_REGISTER 2778 1 2 -600 600 -32768 +id:12344 MODBUS_HOLDING_REGISTER 2779 1 2 -600 600 -32768 +id:12345 MODBUS_HOLDING_REGISTER 2780 1 2 -600 600 -32768 +id:12346 MODBUS_HOLDING_REGISTER 2781 1 2 -600 600 -32768 +id:12347 MODBUS_HOLDING_REGISTER 2782 1 2 -600 600 -32768 +id:12348 MODBUS_HOLDING_REGISTER 2783 1 2 -600 600 -32768 +id:12349 MODBUS_HOLDING_REGISTER 2784 1 2 -600 600 -32768 +id:12350 MODBUS_HOLDING_REGISTER 2785 1 2 -600 600 -32768 +id:12351 MODBUS_HOLDING_REGISTER 2786 1 2 -600 600 -32768 +id:12352 MODBUS_HOLDING_REGISTER 2787 1 2 -600 600 -32768 +id:12353 MODBUS_HOLDING_REGISTER 2788 1 2 -600 600 -32768 +id:12354 MODBUS_HOLDING_REGISTER 2789 1 2 -600 600 -32768 +id:12355 MODBUS_HOLDING_REGISTER 2790 1 2 -600 600 -32768 +id:12356 MODBUS_HOLDING_REGISTER 2791 1 2 -600 600 -32768 +id:12357 MODBUS_HOLDING_REGISTER 2792 1 2 -600 600 -32768 +id:12358 MODBUS_HOLDING_REGISTER 2793 1 2 -600 600 -32768 +id:12359 MODBUS_HOLDING_REGISTER 2794 1 2 -600 600 -32768 +id:12360 MODBUS_HOLDING_REGISTER 2795 1 2 -600 600 -32768 +id:12361 MODBUS_HOLDING_REGISTER 2796 1 2 -600 600 -32768 +id:12362 MODBUS_HOLDING_REGISTER 2797 1 2 -600 600 -32768 +id:12363 MODBUS_HOLDING_REGISTER 2798 1 2 -600 600 -32768 +id:12364 MODBUS_HOLDING_REGISTER 2799 1 2 -600 600 -32768 +id:12365 MODBUS_HOLDING_REGISTER 2800 1 2 -600 600 -32768 +id:12366 MODBUS_HOLDING_REGISTER 2801 1 2 -600 600 -32768 +id:12367 MODBUS_HOLDING_REGISTER 2802 1 2 -600 600 -32768 +id:12368 MODBUS_HOLDING_REGISTER 2803 1 2 -600 600 -32768 +id:12369 MODBUS_HOLDING_REGISTER 2804 1 2 -600 600 -32768 +id:12370 MODBUS_HOLDING_REGISTER 2805 1 2 -600 600 -32768 +id:12371 MODBUS_HOLDING_REGISTER 2806 1 2 -600 600 -32768 +id:12372 MODBUS_HOLDING_REGISTER 2807 1 2 -600 600 -32768 +id:12373 MODBUS_HOLDING_REGISTER 2808 1 2 -600 600 -32768 +id:12374 MODBUS_HOLDING_REGISTER 2809 1 2 -600 600 -32768 +id:12375 MODBUS_HOLDING_REGISTER 2810 1 2 -600 600 -32768 +id:12376 MODBUS_HOLDING_REGISTER 2811 1 2 -600 600 -32768 +id:12377 MODBUS_HOLDING_REGISTER 2812 1 2 -600 600 -32768 +id:12378 MODBUS_HOLDING_REGISTER 2813 1 2 -600 600 -32768 +id:12379 MODBUS_HOLDING_REGISTER 2814 1 2 -600 600 -32768 +id:12380 MODBUS_HOLDING_REGISTER 2815 1 2 -600 600 -32768 +id:12381 MODBUS_HOLDING_REGISTER 2816 1 2 -600 600 -32768 +id:12382 MODBUS_HOLDING_REGISTER 2817 1 2 -600 600 -32768 +id:12383 MODBUS_HOLDING_REGISTER 2818 1 2 -600 600 -32768 +id:12384 MODBUS_HOLDING_REGISTER 2819 1 2 -600 600 -32768 +Period MODBUS_HOLDING_REGISTER 3088 1 4 0 1 0 +Number of years MODBUS_HOLDING_REGISTER 3089 1 4 1 5 1 +Months MODBUS_HOLDING_REGISTER 3090 1 6 0 4095 4095 +id:12388 MODBUS_HOLDING_REGISTER 3092 1 4 0 0 0 +Show outdoor temperature MODBUS_HOLDING_REGISTER 3096 1 4 0 0 0 +Show indoor temperature MODBUS_HOLDING_REGISTER 3097 1 4 0 0 0 +Active days MODBUS_HOLDING_REGISTER 3066 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3067 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3068 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3069 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3070 1 4 0 127 0 +Start time MODBUS_HOLDING_REGISTER 3071 1 - - - - +Start time MODBUS_HOLDING_REGISTER 3073 1 - - - - +Stop time MODBUS_HOLDING_REGISTER 3075 1 - - - - +id:12650 MODBUS_HOLDING_REGISTER 3104 1 - - - - +id:12651 MODBUS_HOLDING_REGISTER 3144 1 - - - - +id:12652 MODBUS_HOLDING_REGISTER 3184 1 - - - - +id:12653 MODBUS_HOLDING_REGISTER 3224 1 - - - - +id:12654 MODBUS_HOLDING_REGISTER 3264 1 - - - - +id:12655 MODBUS_HOLDING_REGISTER 3304 1 - - - - +id:12656 MODBUS_HOLDING_REGISTER 3344 1 - - - - +id:12657 MODBUS_HOLDING_REGISTER 3384 1 - - - - +id:12658 MODBUS_HOLDING_REGISTER 3424 1 - - - - +id:12659 MODBUS_HOLDING_REGISTER 3464 1 - - - - +id:12660 MODBUS_HOLDING_REGISTER 3504 1 - - - - +id:12661 MODBUS_HOLDING_REGISTER 3544 1 - - - - +id:12662 MODBUS_HOLDING_REGISTER 3584 1 - - - - +id:12663 MODBUS_HOLDING_REGISTER 3624 1 - - - - +id:12664 MODBUS_HOLDING_REGISTER 3664 1 - - - - +id:12665 MODBUS_HOLDING_REGISTER 3704 1 - - - - +id:12666 MODBUS_HOLDING_REGISTER 3744 1 - - - - +id:12667 MODBUS_HOLDING_REGISTER 3784 1 - - - - +id:12668 MODBUS_HOLDING_REGISTER 3824 1 - - - - +id:12669 MODBUS_HOLDING_REGISTER 3864 1 - - - - +id:12670 MODBUS_HOLDING_REGISTER 3904 1 - - - - +id:12671 MODBUS_HOLDING_REGISTER 2978 1 4 0 3 0 +id:12672 MODBUS_HOLDING_REGISTER 2979 1 4 0 3 0 +id:12673 MODBUS_HOLDING_REGISTER 2980 1 4 0 3 0 +id:12674 MODBUS_HOLDING_REGISTER 2981 1 4 0 3 0 +id:12675 MODBUS_HOLDING_REGISTER 2982 1 4 0 3 0 +id:12676 MODBUS_HOLDING_REGISTER 2983 1 4 0 3 0 +id:12677 MODBUS_HOLDING_REGISTER 2984 1 4 0 3 0 +id:12678 MODBUS_HOLDING_REGISTER 2985 1 4 0 3 0 +id:12679 MODBUS_HOLDING_REGISTER 2986 1 4 0 15 0 +id:12680 MODBUS_HOLDING_REGISTER 2987 1 4 0 15 0 +id:12681 MODBUS_HOLDING_REGISTER 2988 1 4 0 15 0 +id:12682 MODBUS_HOLDING_REGISTER 2989 1 4 0 15 0 +id:12683 MODBUS_HOLDING_REGISTER 2990 1 4 0 15 0 +id:12684 MODBUS_HOLDING_REGISTER 2991 1 4 0 15 0 +id:12685 MODBUS_HOLDING_REGISTER 2992 1 4 0 15 0 +id:12686 MODBUS_HOLDING_REGISTER 2993 1 4 0 15 0 +id:12687 MODBUS_HOLDING_REGISTER 2994 1 4 0 15 0 +id:12688 MODBUS_HOLDING_REGISTER 2995 1 4 0 15 0 +id:12689 MODBUS_HOLDING_REGISTER 2996 1 4 0 15 0 +id:12690 MODBUS_HOLDING_REGISTER 2997 1 4 0 15 0 +id:12691 MODBUS_HOLDING_REGISTER 2998 1 4 0 3 0 +id:12692 MODBUS_HOLDING_REGISTER 3944 1 6 0 0 0 +id:12693 MODBUS_HOLDING_REGISTER 3946 1 6 0 0 0 +id:12694 MODBUS_HOLDING_REGISTER 3948 1 6 0 0 0 +id:12695 MODBUS_HOLDING_REGISTER 3950 1 6 0 0 0 +id:12696 MODBUS_HOLDING_REGISTER 3952 1 6 0 0 0 +id:12697 MODBUS_HOLDING_REGISTER 3954 1 6 0 0 0 +id:12698 MODBUS_HOLDING_REGISTER 3956 1 6 0 0 0 +id:12699 MODBUS_HOLDING_REGISTER 3958 1 6 0 0 0 +id:12700 MODBUS_HOLDING_REGISTER 3960 1 6 0 0 0 +id:12701 MODBUS_HOLDING_REGISTER 3962 1 6 0 0 0 +id:12702 MODBUS_HOLDING_REGISTER 3964 1 6 0 0 0 +id:12703 MODBUS_HOLDING_REGISTER 3966 1 6 0 0 0 +id:12704 MODBUS_HOLDING_REGISTER 3968 1 6 0 0 0 +id:12705 MODBUS_HOLDING_REGISTER 3970 1 6 0 0 0 +id:12706 MODBUS_HOLDING_REGISTER 3972 1 6 0 0 0 +id:12707 MODBUS_HOLDING_REGISTER 3974 1 6 0 0 0 +id:12708 MODBUS_HOLDING_REGISTER 3976 1 6 0 0 0 +id:12709 MODBUS_HOLDING_REGISTER 3978 1 6 0 0 0 +id:12710 MODBUS_HOLDING_REGISTER 3980 1 6 0 0 0 +id:12711 MODBUS_HOLDING_REGISTER 3982 1 6 0 0 0 +id:12712 MODBUS_HOLDING_REGISTER 3984 1 6 0 0 0 +id:12801 MODBUS_HOLDING_REGISTER 2505 10 °C 3 50 300 200 +id:12802 MODBUS_HOLDING_REGISTER 2507 10 °C 3 50 300 200 +id:12803 MODBUS_HOLDING_REGISTER 2509 10 °C 3 50 300 200 +id:12804 MODBUS_HOLDING_REGISTER 2511 10 °C 3 50 300 200 +id:12805 MODBUS_HOLDING_REGISTER 2513 10 °C 3 50 300 200 +id:12806 MODBUS_HOLDING_REGISTER 2515 10 °C 3 50 300 200 +id:12807 MODBUS_HOLDING_REGISTER 2517 10 °C 3 50 300 200 +id:12808 MODBUS_HOLDING_REGISTER 2519 10 °C 3 50 300 200 +id:12809 MODBUS_HOLDING_REGISTER 2521 10 °C 3 50 300 200 +id:12810 MODBUS_HOLDING_REGISTER 2523 10 °C 3 50 300 200 +id:12811 MODBUS_HOLDING_REGISTER 2525 10 °C 3 50 300 200 +id:12812 MODBUS_HOLDING_REGISTER 2527 10 °C 3 50 300 200 +id:12813 MODBUS_HOLDING_REGISTER 2529 10 °C 3 50 300 200 +id:12814 MODBUS_HOLDING_REGISTER 2531 10 °C 3 50 300 200 +id:12815 MODBUS_HOLDING_REGISTER 2533 10 °C 3 50 300 200 +id:12816 MODBUS_HOLDING_REGISTER 2535 10 °C 3 50 300 200 +id:12817 MODBUS_HOLDING_REGISTER 2537 10 °C 3 50 300 200 +id:12818 MODBUS_HOLDING_REGISTER 2539 10 °C 3 50 300 200 +id:12819 MODBUS_HOLDING_REGISTER 2541 10 °C 3 50 300 200 +id:12820 MODBUS_HOLDING_REGISTER 2543 10 °C 3 50 300 200 +id:12821 MODBUS_HOLDING_REGISTER 2545 10 °C 3 50 300 200 +id:12822 MODBUS_HOLDING_REGISTER 2547 10 °C 3 50 300 200 +id:12823 MODBUS_HOLDING_REGISTER 2549 10 °C 3 50 300 200 +id:12824 MODBUS_HOLDING_REGISTER 2551 10 °C 3 50 300 200 +id:12825 MODBUS_HOLDING_REGISTER 2553 10 °C 3 50 300 200 +id:12826 MODBUS_HOLDING_REGISTER 2555 10 °C 3 50 300 200 +id:12827 MODBUS_HOLDING_REGISTER 2557 10 °C 3 50 300 200 +id:12828 MODBUS_HOLDING_REGISTER 2559 10 °C 3 50 300 200 +id:12829 MODBUS_HOLDING_REGISTER 2561 10 °C 3 50 300 200 +id:12830 MODBUS_HOLDING_REGISTER 2563 10 °C 3 50 300 200 +id:12831 MODBUS_HOLDING_REGISTER 2565 10 °C 3 50 300 200 +id:12832 MODBUS_HOLDING_REGISTER 2567 10 °C 3 50 300 200 +id:12833 MODBUS_HOLDING_REGISTER 2569 10 °C 3 50 300 200 +id:12834 MODBUS_HOLDING_REGISTER 2571 10 °C 3 50 300 200 +id:12835 MODBUS_HOLDING_REGISTER 2573 10 °C 3 50 300 200 +id:12836 MODBUS_HOLDING_REGISTER 2575 10 °C 3 50 300 200 +id:12837 MODBUS_HOLDING_REGISTER 2577 10 °C 3 50 300 200 +id:12838 MODBUS_HOLDING_REGISTER 2579 10 °C 3 50 300 200 +id:12839 MODBUS_HOLDING_REGISTER 2581 10 °C 3 50 300 200 +id:12840 MODBUS_HOLDING_REGISTER 2583 10 °C 3 50 300 200 +id:12841 MODBUS_HOLDING_REGISTER 2585 10 °C 3 50 300 250 +id:12842 MODBUS_HOLDING_REGISTER 2587 10 °C 3 50 300 250 +id:12843 MODBUS_HOLDING_REGISTER 2589 10 °C 3 50 300 250 +id:12844 MODBUS_HOLDING_REGISTER 2591 10 °C 3 50 300 250 +id:12845 MODBUS_HOLDING_REGISTER 2593 10 °C 3 50 300 250 +id:12846 MODBUS_HOLDING_REGISTER 2595 10 °C 3 50 300 250 +id:12847 MODBUS_HOLDING_REGISTER 2597 10 °C 3 50 300 250 +id:12848 MODBUS_HOLDING_REGISTER 2599 10 °C 3 50 300 250 +id:12849 MODBUS_HOLDING_REGISTER 2601 10 °C 3 50 300 250 +id:12850 MODBUS_HOLDING_REGISTER 2603 10 °C 3 50 300 250 +id:12851 MODBUS_HOLDING_REGISTER 2605 10 °C 3 50 300 250 +id:12852 MODBUS_HOLDING_REGISTER 2607 10 °C 3 50 300 250 +id:12853 MODBUS_HOLDING_REGISTER 2609 10 °C 3 50 300 250 +id:12854 MODBUS_HOLDING_REGISTER 2611 10 °C 3 50 300 250 +id:12855 MODBUS_HOLDING_REGISTER 2613 10 °C 3 50 300 250 +id:12856 MODBUS_HOLDING_REGISTER 2615 10 °C 3 50 300 250 +id:12857 MODBUS_HOLDING_REGISTER 2617 10 °C 3 50 300 250 +id:12858 MODBUS_HOLDING_REGISTER 2619 10 °C 3 50 300 250 +id:12859 MODBUS_HOLDING_REGISTER 2621 10 °C 3 50 300 250 +id:12860 MODBUS_HOLDING_REGISTER 2623 10 °C 3 50 300 250 +id:12861 MODBUS_HOLDING_REGISTER 2625 10 °C 3 50 300 250 +id:12862 MODBUS_HOLDING_REGISTER 2627 10 °C 3 50 300 250 +id:12863 MODBUS_HOLDING_REGISTER 2629 10 °C 3 50 300 250 +id:12864 MODBUS_HOLDING_REGISTER 2631 10 °C 3 50 300 250 +id:12865 MODBUS_HOLDING_REGISTER 2633 10 °C 3 50 300 250 +id:12866 MODBUS_HOLDING_REGISTER 2635 10 °C 3 50 300 250 +id:12867 MODBUS_HOLDING_REGISTER 2637 10 °C 3 50 300 250 +id:12868 MODBUS_HOLDING_REGISTER 2639 10 °C 3 50 300 250 +id:12869 MODBUS_HOLDING_REGISTER 2641 10 °C 3 50 300 250 +id:12870 MODBUS_HOLDING_REGISTER 2643 10 °C 3 50 300 250 +id:12871 MODBUS_HOLDING_REGISTER 2645 10 °C 3 50 300 250 +id:12872 MODBUS_HOLDING_REGISTER 2647 10 °C 3 50 300 250 +id:12873 MODBUS_HOLDING_REGISTER 2649 10 °C 3 50 300 250 +id:12874 MODBUS_HOLDING_REGISTER 2651 10 °C 3 50 300 250 +id:12875 MODBUS_HOLDING_REGISTER 2653 10 °C 3 50 300 250 +id:12876 MODBUS_HOLDING_REGISTER 2655 10 °C 3 50 300 250 +id:12877 MODBUS_HOLDING_REGISTER 2657 10 °C 3 50 300 250 +id:12878 MODBUS_HOLDING_REGISTER 2659 10 °C 3 50 300 250 +id:12879 MODBUS_HOLDING_REGISTER 2661 10 °C 3 50 300 250 +id:12880 MODBUS_HOLDING_REGISTER 2663 10 °C 3 50 300 250 +id:13796 MODBUS_INPUT_REGISTER 2243 1 4 0 0 0 +id:13797 MODBUS_INPUT_REGISTER 2244 1 4 0 0 0 +id:13798 MODBUS_INPUT_REGISTER 2245 1 4 0 0 0 +id:13799 MODBUS_INPUT_REGISTER 2246 1 4 0 0 0 +id:13800 MODBUS_INPUT_REGISTER 2247 1 4 0 0 0 +id:13801 MODBUS_INPUT_REGISTER 2248 1 4 0 0 0 +id:13802 MODBUS_INPUT_REGISTER 2249 1 4 0 0 0 +id:13803 MODBUS_INPUT_REGISTER 2250 1 4 0 0 0 +Offset cooling (EME20) MODBUS_HOLDING_REGISTER 2667 1 1 -10 0 -1 +Offset heating (EME20) MODBUS_HOLDING_REGISTER 2668 1 4 0 10 1 +Offset pool (EME20) MODBUS_HOLDING_REGISTER 2669 1 °C 4 0 10 10 +Cooling (EME20) MODBUS_HOLDING_REGISTER 2666 1 4 0 1 0 +AUX (EME20) MODBUS_HOLDING_REGISTER 2675 1 4 0 1 0 +id:14052 MODBUS_HOLDING_REGISTER 2670 1 kW 6 1 999 1 +id:14061 MODBUS_HOLDING_REGISTER 2672 1 4 0 1 0 +Temperature, Overload, pool MODBUS_HOLDING_REGISTER 0 1 °C 4 1 50 1 +EME20 API MODBUS_HOLDING_REGISTER 2107 1 4 0 1 0 +EME20 API Include own consumption MODBUS_HOLDING_REGISTER 2108 1 4 0 1 0 +EME20 API Available power MODBUS_HOLDING_REGISTER 2109 1 5 0 65535 0 +External adjustment input, main unit (ECS1) MODBUS_HOLDING_REGISTER 2111 1 4 0 1 0 +External adjustment input (ECS2) MODBUS_HOLDING_REGISTER 2112 1 4 0 1 0 +External adjustment input (ECS3) MODBUS_HOLDING_REGISTER 2113 1 4 0 1 0 +External adjustment input (ECS4) MODBUS_HOLDING_REGISTER 2114 1 4 0 1 0 +External adjustment input (ECS5) MODBUS_HOLDING_REGISTER 2115 1 4 0 1 0 +External adjustment input (ECS6) MODBUS_HOLDING_REGISTER 2116 1 4 0 1 0 +External adjustment input (ECS7) MODBUS_HOLDING_REGISTER 2117 1 4 0 1 0 +External adjustment input (ECS8) MODBUS_HOLDING_REGISTER 2118 1 4 0 1 0 +Zone 1 affected by ECS1 MODBUS_HOLDING_REGISTER 2119 1 4 0 1 0 +Zone 2 affected by ECS1 MODBUS_HOLDING_REGISTER 2120 1 4 0 1 0 +Zone 3 affected by ECS1 MODBUS_HOLDING_REGISTER 2121 1 4 0 1 0 +Zone 4 affected by ECS1 MODBUS_HOLDING_REGISTER 2122 1 4 0 1 0 +Zone 5 affected by ECS1 MODBUS_HOLDING_REGISTER 2123 1 4 0 1 0 +Zone 6 affected by ECS1 MODBUS_HOLDING_REGISTER 2124 1 4 0 1 0 +Zone 7 affected by ECS1 MODBUS_HOLDING_REGISTER 2125 1 4 0 1 0 +Zone 8 affected by ECS1 MODBUS_HOLDING_REGISTER 2126 1 4 0 1 0 +Zone 9 affected by ECS1 MODBUS_HOLDING_REGISTER 2127 1 4 0 1 0 +Zone 10 affected by ECS1 MODBUS_HOLDING_REGISTER 2128 1 4 0 1 0 +Zone 11 affected by ECS1 MODBUS_HOLDING_REGISTER 2129 1 4 0 1 0 +Zone 12 affected by ECS1 MODBUS_HOLDING_REGISTER 2130 1 4 0 1 0 +Zone 13 affected by ECS1 MODBUS_HOLDING_REGISTER 2131 1 4 0 1 0 +Zone 14 affected by ECS1 MODBUS_HOLDING_REGISTER 2132 1 4 0 1 0 +Zone 15 affected by ECS1 MODBUS_HOLDING_REGISTER 2133 1 4 0 1 0 +Zone 16 affected by ECS1 MODBUS_HOLDING_REGISTER 2134 1 4 0 1 0 +Zone 17 affected by ECS1 MODBUS_HOLDING_REGISTER 2135 1 4 0 1 0 +Zone 18 affected by ECS1 MODBUS_HOLDING_REGISTER 2136 1 4 0 1 0 +Zone 19 affected by ECS1 MODBUS_HOLDING_REGISTER 2137 1 4 0 1 0 +Zone 20 affected by ECS1 MODBUS_HOLDING_REGISTER 2138 1 4 0 1 0 +Zone 21 affected by ECS1 MODBUS_HOLDING_REGISTER 2139 1 4 0 1 0 +Zone 22 affected by ECS1 MODBUS_HOLDING_REGISTER 2140 1 4 0 1 0 +Zone 23 affected by ECS1 MODBUS_HOLDING_REGISTER 2141 1 4 0 1 0 +Zone 24 affected by ECS1 MODBUS_HOLDING_REGISTER 2142 1 4 0 1 0 +Zone 25 affected by ECS1 MODBUS_HOLDING_REGISTER 2143 1 4 0 1 0 +Zone 26 affected by ECS1 MODBUS_HOLDING_REGISTER 2144 1 4 0 1 0 +Zone 27 affected by ECS1 MODBUS_HOLDING_REGISTER 2145 1 4 0 1 0 +Zone 28 affected by ECS1 MODBUS_HOLDING_REGISTER 2146 1 4 0 1 0 +Zone 29 affected by ECS1 MODBUS_HOLDING_REGISTER 2147 1 4 0 1 0 +Zone 30 affected by ECS1 MODBUS_HOLDING_REGISTER 2148 1 4 0 1 0 +Zone 31 affected by ECS1 MODBUS_HOLDING_REGISTER 2149 1 4 0 1 0 +Zone 32 affected by ECS1 MODBUS_HOLDING_REGISTER 2150 1 4 0 1 0 +Zone 33 affected by ECS1 MODBUS_HOLDING_REGISTER 2151 1 4 0 1 0 +Zone 34 affected by ECS1 MODBUS_HOLDING_REGISTER 2152 1 4 0 1 0 +Zone 35 affected by ECS1 MODBUS_HOLDING_REGISTER 2153 1 4 0 1 0 +Zone 36 affected by ECS1 MODBUS_HOLDING_REGISTER 2154 1 4 0 1 0 +Zone 37 affected by ECS1 MODBUS_HOLDING_REGISTER 2155 1 4 0 1 0 +Zone 38 affected by ECS1 MODBUS_HOLDING_REGISTER 2156 1 4 0 1 0 +Zone 39 affected by ECS1 MODBUS_HOLDING_REGISTER 2157 1 4 0 1 0 +Zone 40 affected by ECS1 MODBUS_HOLDING_REGISTER 2158 1 4 0 1 0 +Input on ECS1 affects ECS1 MODBUS_HOLDING_REGISTER 2439 1 4 0 1 0 +Input on ECS1 affects ECS2 MODBUS_HOLDING_REGISTER 2440 1 4 0 1 0 +Input on ECS1 affects ECS3 MODBUS_HOLDING_REGISTER 2441 1 4 0 1 0 +Input on ECS1 affects ECS4 MODBUS_HOLDING_REGISTER 2442 1 4 0 1 0 +Input on ECS1 affects ECS5 MODBUS_HOLDING_REGISTER 2443 1 4 0 1 0 +Input on ECS1 affects ECS6 MODBUS_HOLDING_REGISTER 2444 1 4 0 1 0 +Input on ECS1 affects ECS7 MODBUS_HOLDING_REGISTER 2445 1 4 0 1 0 +Input on ECS1 affects ECS8 MODBUS_HOLDING_REGISTER 2446 1 4 0 1 0 +External setting for adjustment migrated MODBUS_HOLDING_REGISTER 2503 1 4 0 1 0 +Version, inverter (EB101) MODBUS_INPUT_REGISTER 2147 1 4 0 0 0 +Time between filter replacement MODBUS_HOLDING_REGISTER 2676 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2677 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2678 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2679 1 4 1 24 3 +id:21077 MODBUS_HOLDING_REGISTER 3020 1 4 0 0 0 +id:21078 MODBUS_HOLDING_REGISTER 3021 1 4 0 0 0 +id:21079 MODBUS_HOLDING_REGISTER 3022 1 4 0 0 0 +id:21080 MODBUS_HOLDING_REGISTER 3023 1 4 0 0 0 +id:21081 MODBUS_HOLDING_REGISTER 3024 1 4 0 0 0 +id:21082 MODBUS_HOLDING_REGISTER 3025 1 4 0 0 0 +id:21083 MODBUS_HOLDING_REGISTER 3026 1 4 0 0 0 +id:21084 MODBUS_HOLDING_REGISTER 3027 1 4 0 0 0 +Return time fan 4 MODBUS_HOLDING_REGISTER 2700 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2701 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2702 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2703 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2704 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2705 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2706 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2707 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2708 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2709 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2710 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2711 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2712 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2713 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2714 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2715 1 h 4 1 24 4 +Time between filter replacement MODBUS_HOLDING_REGISTER 2728 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2729 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2730 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2731 1 4 1 24 3 +AUX from Modbus MODBUS_HOLDING_REGISTER 2740 1 4 0 61 0 +AUX from Modbus MODBUS_HOLDING_REGISTER 2741 1 2 0 0 0 +Last defrost, heat pump 1 MODBUS_INPUT_REGISTER 2158 1 4 0 255 255 +ERS 2 MODBUS_HOLDING_REGISTER 2820 1 4 0 1 0 +ERS 3 MODBUS_HOLDING_REGISTER 2821 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 2822 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 2823 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 2824 1 4 0 1 1 +ERS 4 MODBUS_HOLDING_REGISTER 2825 1 4 0 1 1 +ERS 4 MODBUS_HOLDING_REGISTER 2826 1 4 0 1 1 +ERS 4 MODBUS_HOLDING_REGISTER 2827 1 4 0 1 1 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2857 1 °C 4 0 10 3 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2858 1 °C 4 0 10 3 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2859 1 °C 4 0 10 3 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2860 1 °C 4 0 10 3 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2828 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2829 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2830 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2831 1 4 0 2 2 +id:23145 MODBUS_HOLDING_REGISTER 2921 1 4 0 1 0 +id:23146 MODBUS_HOLDING_REGISTER 2922 1 4 0 1 0 +id:23147 MODBUS_HOLDING_REGISTER 2923 1 4 0 1 0 +id:23148 MODBUS_HOLDING_REGISTER 2924 1 4 0 1 0 +id:23149 MODBUS_HOLDING_REGISTER 2836 10 °C 2 -200 410 190 +id:23150 MODBUS_HOLDING_REGISTER 2837 10 °C 2 -200 410 190 +id:23151 MODBUS_HOLDING_REGISTER 2838 10 °C 2 -200 410 190 +id:23152 MODBUS_HOLDING_REGISTER 2839 10 °C 2 -200 410 190 +id:23153 MODBUS_HOLDING_REGISTER 2832 10 °C 2 30 100 30 +id:23154 MODBUS_HOLDING_REGISTER 2833 10 °C 2 30 100 30 +id:23155 MODBUS_HOLDING_REGISTER 2834 10 °C 2 30 100 30 +id:23156 MODBUS_HOLDING_REGISTER 2835 10 °C 2 30 100 30 +Fan mode 5 MODBUS_INPUT_REGISTER 2168 1 % 4 0 0 0 +Fan mode 6 MODBUS_INPUT_REGISTER 2169 1 % 4 0 0 0 +Fan mode 7 MODBUS_INPUT_REGISTER 2170 1 % 4 0 0 0 +Fan mode 8 MODBUS_INPUT_REGISTER 2171 1 % 4 0 0 0 +Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 4204 1 4 0 1 0 +Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 5025 1 4 0 1 0 +id:24483 MODBUS_HOLDING_REGISTER 5008 1 4 0 1 0 +id:24484 MODBUS_HOLDING_REGISTER 5009 10 °C 2 50 800 450 +id:24485 MODBUS_HOLDING_REGISTER 5010 10 °C 2 50 800 450 +id:24486 MODBUS_HOLDING_REGISTER 5011 10 °C 2 50 800 450 +id:24487 MODBUS_HOLDING_REGISTER 5012 10 °C 2 50 800 450 +id:24488 MODBUS_HOLDING_REGISTER 5013 10 °C 2 50 800 450 +id:24489 MODBUS_HOLDING_REGISTER 5014 10 °C 2 50 800 450 +id:24490 MODBUS_HOLDING_REGISTER 5015 10 °C 2 50 800 450 +id:24491 MODBUS_HOLDING_REGISTER 5016 10 °C 2 50 800 450 +id:24492 MODBUS_HOLDING_REGISTER 5017 10 °C 2 -50 300 250 +id:24493 MODBUS_HOLDING_REGISTER 5018 10 °C 2 -50 300 250 +id:24494 MODBUS_HOLDING_REGISTER 5019 10 °C 2 -50 300 250 +id:24495 MODBUS_HOLDING_REGISTER 5020 10 °C 2 -50 300 250 +id:24496 MODBUS_HOLDING_REGISTER 5021 10 °C 2 -50 300 250 +id:24497 MODBUS_HOLDING_REGISTER 5022 10 °C 2 -50 300 250 +id:24498 MODBUS_HOLDING_REGISTER 5023 10 °C 2 -50 300 250 +id:24499 MODBUS_HOLDING_REGISTER 5024 10 °C 2 -50 300 250 +id:24634 MODBUS_HOLDING_REGISTER 5031 10 °C 2 50 800 450 +id:24635 MODBUS_HOLDING_REGISTER 5032 10 °C 2 50 800 450 +id:24636 MODBUS_HOLDING_REGISTER 5033 10 °C 2 50 800 450 +id:24637 MODBUS_HOLDING_REGISTER 5034 10 °C 2 50 800 450 +id:24638 MODBUS_HOLDING_REGISTER 5035 10 °C 2 50 800 450 +id:24639 MODBUS_HOLDING_REGISTER 5036 10 °C 2 50 800 450 +id:24640 MODBUS_HOLDING_REGISTER 5037 10 °C 2 50 800 450 +id:24641 MODBUS_HOLDING_REGISTER 5038 10 °C 2 50 800 450 +id:24642 MODBUS_HOLDING_REGISTER 5039 10 °C 2 50 800 450 +id:24643 MODBUS_HOLDING_REGISTER 5040 10 °C 2 50 800 450 +id:24644 MODBUS_HOLDING_REGISTER 5041 10 °C 2 50 800 450 +id:24645 MODBUS_HOLDING_REGISTER 5042 10 °C 2 50 800 450 +id:24646 MODBUS_HOLDING_REGISTER 5043 10 °C 2 50 800 450 +id:24647 MODBUS_HOLDING_REGISTER 5044 10 °C 2 50 800 450 +id:24648 MODBUS_HOLDING_REGISTER 5045 10 °C 2 50 800 450 +id:24649 MODBUS_HOLDING_REGISTER 5046 10 °C 2 50 800 450 +id:24650 MODBUS_HOLDING_REGISTER 5047 10 °C 2 50 800 450 +id:24651 MODBUS_HOLDING_REGISTER 5048 10 °C 2 50 800 450 +id:24652 MODBUS_HOLDING_REGISTER 5049 10 °C 2 50 800 450 +id:24653 MODBUS_HOLDING_REGISTER 5050 10 °C 2 50 800 450 +id:24654 MODBUS_HOLDING_REGISTER 5051 10 °C 2 50 800 450 +id:24655 MODBUS_HOLDING_REGISTER 5052 10 °C 2 50 800 450 +id:24656 MODBUS_HOLDING_REGISTER 5053 10 °C 2 50 800 450 +id:24657 MODBUS_HOLDING_REGISTER 5054 10 °C 2 50 800 450 +id:24681 MODBUS_HOLDING_REGISTER 5056 1 4 0 1 0 +id:24682 MODBUS_HOLDING_REGISTER 5057 1 4 0 1 0 +id:24683 MODBUS_HOLDING_REGISTER 5058 1 4 0 255 0 +id:24684 MODBUS_HOLDING_REGISTER 5059 1 4 0 1 0 +Relay status MODBUS_INPUT_REGISTER 0 1 4 0 0 0 +id:24969 MODBUS_HOLDING_REGISTER 5060 1 4 0 1 0 +id:24970 MODBUS_HOLDING_REGISTER 5061 1 2 -100 10000 0 +id:24971 MODBUS_HOLDING_REGISTER 5062 1 4 0 1 0 +id:24972 MODBUS_HOLDING_REGISTER 5063 1 5 0 1000 0 +id:24973 MODBUS_HOLDING_REGISTER 5064 1 4 0 1 0 +id:24974 MODBUS_HOLDING_REGISTER 5065 1 4 0 1 0 +id:24975 MODBUS_HOLDING_REGISTER 5066 1 5 0 1000 0 +id:24976 MODBUS_HOLDING_REGISTER 5067 1 4 0 1 0 +id:24977 MODBUS_HOLDING_REGISTER 5068 1 4 0 1 0 +id:24978 MODBUS_HOLDING_REGISTER 5069 1 5 0 1000 0 +id:24979 MODBUS_HOLDING_REGISTER 5070 1 4 0 1 0 +id:24980 MODBUS_HOLDING_REGISTER 5071 1 5 0 1000 0 +id:55035 MODBUS_HOLDING_REGISTER 1555 1 4 0 40 0 +id:55036 MODBUS_HOLDING_REGISTER 1556 1 4 0 40 0 +id:55037 MODBUS_HOLDING_REGISTER 1557 1 4 0 40 0 +id:55076 MODBUS_HOLDING_REGISTER 2877 1 4 0 1 0 +id:55077 MODBUS_HOLDING_REGISTER 2878 1 4 0 1 0 +id:55078 MODBUS_HOLDING_REGISTER 2879 1 4 0 1 0 +id:55079 MODBUS_HOLDING_REGISTER 2880 1 4 0 1 0 +id:55080 MODBUS_HOLDING_REGISTER 2881 1 4 0 1 0 +id:55081 MODBUS_HOLDING_REGISTER 2882 1 4 0 1 0 +id:55082 MODBUS_HOLDING_REGISTER 2883 1 4 0 1 0 +id:55083 MODBUS_HOLDING_REGISTER 2884 1 4 0 1 0 +Immersion heater power, emergency mode MODBUS_HOLDING_REGISTER 3028 100 kW 2 0 4500 600 +Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 3986 1 4 0 1 0 +Return line (AZ2-BT69) MODBUS_INPUT_REGISTER 2190 10 °C 2 0 0 0 +Supply line (AZ2-BT68) MODBUS_INPUT_REGISTER 2191 10 °C 2 0 0 0 +id:55100 MODBUS_INPUT_REGISTER 2192 10 °C 2 0 0 0 +id:55101 MODBUS_INPUT_REGISTER 2193 10 °C 2 0 0 0 +id:55102 MODBUS_INPUT_REGISTER 2194 10 °C 2 0 0 0 diff --git a/nibe/data/s2125.json b/nibe/data/s2125.json new file mode 100644 index 0000000..e9b2b66 --- /dev/null +++ b/nibe/data/s2125.json @@ -0,0 +1,6746 @@ +{ + "30002": { + "title": "Current outdoor temperature (BT1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "current-outdoor-temperature-bt1-30002" + }, + "30003": { + "title": "Supply line (EP23-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep23-bt2-30003" + }, + "30004": { + "title": "Supply line (EP22-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep22-bt2-30004" + }, + "30005": { + "title": "Supply line (EP21-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep21-bt2-30005" + }, + "30006": { + "title": "Supply line (BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-bt2-30006" + }, + "30008": { + "title": "Return line (BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-bt3-30008" + }, + "30009": { + "title": "Hot water top (BT7)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-top-bt7-30009" + }, + "30010": { + "title": "Hot water charging (BT6)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-charging-bt6-30010" + }, + "30027": { + "title": "Roomsensor 1-1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "roomsensor-1-1-30027" + }, + "30037": { + "title": "Temperature limiter (EB100-FD1)", + "factor": 1, + "size": "s16", + "name": "temperature-limiter-eb100-fd1-30037" + }, + "30038": { + "title": "Average temperature (BT1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "average-temperature-bt1-30038" + }, + "30039": { + "title": "Boiler temperature (BT52)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "boiler-temperature-bt52-30039" + }, + "30041": { + "title": "Flow sensor (BF1)", + "factor": 10, + "unit": "l/m", + "size": "s16", + "name": "flow-sensor-bf1-30041" + }, + "30042": { + "title": "Electrical anode (EB100-FR1)", + "factor": 1, + "size": "s16", + "name": "electrical-anode-eb100-fr1-30042" + }, + "30047": { + "title": "Current (BE3)", + "factor": 10, + "unit": "A", + "size": "u32", + "name": "current-be3-30047" + }, + "30073": { + "title": "Additional heat (BT63)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "additional-heat-bt63-30073" + }, + "30076": { + "title": "Return line (EP23-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep23-bt3-30076" + }, + "30077": { + "title": "Return line (EP22-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep22-bt3-30077" + }, + "30078": { + "title": "Return line (EP21-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep21-bt3-30078" + }, + "30079": { + "title": "Return line (EP15-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep15-bt3-30079" + }, + "30088": { + "title": "Outgoing hot water (BT70)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "outgoing-hot-water-bt70-30088" + }, + "30095": { + "title": "Supply line (EP47-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep47-bt2-30095" + }, + "30096": { + "title": "Supply line (EP46-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep46-bt2-30096" + }, + "30097": { + "title": "Supply line (EP45-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep45-bt2-30097" + }, + "30098": { + "title": "Supply line (EP44-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep44-bt2-30098" + }, + "30099": { + "title": "Return line (EP47-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep47-bt3-30099" + }, + "30100": { + "title": "Return line (EP46-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep46-bt3-30100" + }, + "30101": { + "title": "Return line (EP45-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep45-bt3-30101" + }, + "30102": { + "title": "Return line (EP44-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep44-bt3-30102" + }, + "30110": { + "title": "Room average temp. clim. system 8 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-8-bt50-30110" + }, + "30111": { + "title": "Room average temp. clim. system 7 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-7-bt50-30111" + }, + "30112": { + "title": "Room average temp. clim. system 6 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-6-bt50-30112" + }, + "30113": { + "title": "Room average temp. clim. system 5 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-5-bt50-30113" + }, + "30114": { + "title": "Room average temp. clim. system 4 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-4-bt50-30114" + }, + "30115": { + "title": "Room average temp. clim. system 3 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-3-bt50-30115" + }, + "30116": { + "title": "Room average temp. clim. system 2 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-2-bt50-30116" + }, + "30117": { + "title": "Room average temp. clim. system 1 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-1-bt50-30117" + }, + "30120": { + "title": "External cooling supply temperature (BT25)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "external-cooling-supply-temperature-bt25-30120" + }, + "30130": { + "title": "Oper. mode shunt climate system 8", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-8-30130" + }, + "30131": { + "title": "Oper. mode shunt climate system 7", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-7-30131" + }, + "30132": { + "title": "Oper. mode shunt climate system 6", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-6-30132" + }, + "30133": { + "title": "Oper. mode shunt climate system 5", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-5-30133" + }, + "30135": { + "title": "Relay status (ERS 1)", + "factor": 1, + "size": "u8", + "name": "relay-status-ers-1-30135" + }, + "30136": { + "title": "Fan speed (AZ30-GQ2)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-speed-az30-gq2-30136" + }, + "30137": { + "title": "Fan speed (AZ30-GQ3)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-speed-az30-gq3-30137" + }, + "30138": { + "title": "Current hot water mode controlled by", + "factor": 1, + "size": "s8", + "name": "current-hot-water-mode-controlled-by-30138" + }, + "30142": { + "title": "Max. compressor frequency, heating", + "factor": 100, + "unit": "Hz", + "size": "u16", + "name": "max-compressor-frequency-heating-30142" + }, + "30143": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30143" + }, + "30144": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30144" + }, + "30152": { + "title": "External adjustment climate system 8", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-8-30152" + }, + "30153": { + "title": "External adjustment climate system 7", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-7-30153" + }, + "30154": { + "title": "External adjustment climate system 6", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-6-30154" + }, + "30155": { + "title": "External adjustment climate system 5", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-5-30155" + }, + "30157": { + "title": "Climate system 8", + "factor": 1, + "size": "u8", + "name": "climate-system-8-30157" + }, + "30158": { + "title": "Climate system 7", + "factor": 1, + "size": "u8", + "name": "climate-system-7-30158" + }, + "30159": { + "title": "Climate system 6", + "factor": 1, + "size": "u8", + "name": "climate-system-6-30159" + }, + "30160": { + "title": "Climate system 5", + "factor": 1, + "size": "u8", + "name": "climate-system-5-30160" + }, + "30175": { + "title": "Hot water comfort return (BT82)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-comfort-return-bt82-30175" + }, + "30176": { + "title": "Hot water comfort heater (BT83)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-comfort-heater-bt83-30176" + }, + "30280": { + "title": "Compressor, total time cooling, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-cooling-main-unit-ep14-30280" + }, + "30282": { + "title": "Compressor, total time pool, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-main-unit-ep14-30282" + }, + "30284": { + "title": "Compressor, total time pool 2, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-main-unit-ep14-30284" + }, + "30302": { + "title": "Heat pump 1 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-1-requested-compressor-frequency-30302" + }, + "30303": { + "title": "Main unit, requested compressor freq", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "main-unit-requested-compressor-freq-30303" + }, + "30311": { + "title": "Frost protection heat exchanger, main unit", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-main-unit-30311" + }, + "30312": { + "title": "Status (OPT)", + "factor": 1, + "size": "u8", + "name": "status-opt-30312" + }, + "30313": { + "title": "Version (OPT)", + "factor": 1, + "size": "u16", + "name": "version-opt-30313" + }, + "30314": { + "title": "OPT relay, modulation level", + "factor": 10, + "unit": "%", + "size": "s16", + "name": "opt-relay-modulation-level-30314" + }, + "30316": { + "title": "OPT operating time", + "factor": 1, + "unit": "h", + "size": "u16", + "name": "opt-operating-time-30316" + }, + "30318": { + "title": "Available compressors heating", + "factor": 1, + "size": "u8", + "name": "available-compressors-heating-30318" + }, + "30319": { + "title": "Available compressors hot water", + "factor": 1, + "size": "u8", + "name": "available-compressors-hot-water-30319" + }, + "30320": { + "title": "Available compressors pool 1", + "factor": 1, + "size": "u8", + "name": "available-compressors-pool-1-30320" + }, + "30322": { + "title": "Available compressors cooling", + "factor": 1, + "size": "u8", + "name": "available-compressors-cooling-30322" + }, + "30328": { + "title": "+Adjust, port", + "factor": 1, + "size": "u8", + "name": "adjust-port-30328" + }, + "30329": { + "title": "+Adjust, operating mode", + "factor": 1, + "size": "u8", + "name": "adjust-operating-mode-30329" + }, + "30330": { + "title": "+Adjust, comfort", + "factor": 1, + "size": "u8", + "name": "adjust-comfort-30330" + }, + "30331": { + "title": "+Adjust, parallel adjustment", + "factor": 1, + "size": "s8", + "name": "adjust-parallel-adjustment-30331" + }, + "30332": { + "title": "+Adjust, humidity", + "factor": 10, + "unit": "%RH", + "size": "s16", + "name": "adjust-humidity-30332" + }, + "30333": { + "title": "+Adjust, indoor temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "adjust-indoor-temperature-30333" + }, + "30334": { + "title": "+Adjust, outdoor temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "adjust-outdoor-temperature-30334" + }, + "30335": { + "title": "+Adjust, version", + "factor": 1, + "size": "u16", + "name": "adjust-version-30335" + }, + "30336": { + "title": "+Adjust, active", + "factor": 1, + "size": "u8", + "name": "adjust-active-30336" + }, + "30337": { + "title": "+Adjust, demand", + "factor": 1, + "size": "u8", + "name": "adjust-demand-30337" + }, + "40002": { + "title": "+Adjust, parallel factor", + "factor": 1, + "size": "s8", + "min": 1.0, + "max": 10.0, + "default": 5.0, + "name": "adjust-parallel-factor-40002", + "write": true + }, + "40003": { + "title": "+Adjust, Parallel (min-max)", + "factor": 1, + "size": "s8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "adjust-parallel-min-max-40003", + "write": true + }, + "30338": { + "title": "Supply temperature (BT64)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-temperature-bt64-30338" + }, + "30339": { + "title": "Heat pump functionality 2", + "factor": 1, + "size": "u32", + "name": "heat-pump-functionality-2-30339" + }, + "30345": { + "title": "Status (S135)", + "factor": 1, + "size": "u8", + "name": "status-s135-30345" + }, + "30346": { + "title": "Status, demand, pump speed (S135)", + "factor": 1, + "size": "u8", + "name": "status-demand-pump-speed-s135-30346" + }, + "30347": { + "title": "Status, demand, fan speed (S135)", + "factor": 1, + "size": "u8", + "name": "status-demand-fan-speed-s135-30347" + }, + "30348": { + "title": "Status, solenoid (S135)", + "factor": 1, + "size": "u8", + "name": "status-solenoid-s135-30348" + }, + "30349": { + "title": "Status, compressor, heater(S135)", + "factor": 1, + "size": "u8", + "name": "status-compressor-heater-s135-30349" + }, + "30351": { + "title": "Status, compressor, demand (S135)", + "factor": 1, + "size": "u8", + "name": "status-compressor-demand-s135-30351" + }, + "30352": { + "title": "No. of starts (S135)", + "factor": 1, + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "no-of-starts-s135-30352" + }, + "30354": { + "title": "Operating time (S135)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "operating-time-s135-30354" + }, + "40012": { + "title": "Degree minutes", + "factor": 10, + "unit": "DM", + "size": "s32", + "min": -30000.0, + "max": 30000.0, + "default": 0.0, + "name": "degree-minutes-40012", + "write": true + }, + "30359": { + "title": "Blocking (ERS 1)", + "factor": 1, + "size": "u8", + "name": "blocking-ers-1-30359" + }, + "30360": { + "title": "AZ30-EB17", + "factor": 1, + "size": "u8", + "name": "az30-eb17-30360" + }, + "30361": { + "title": "Supply line (S135-BT12)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-s135-bt12-30361" + }, + "30362": { + "title": "Return line (S135-BT13)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-s135-bt13-30362" + }, + "30363": { + "title": "Evaporator (S135-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-s135-bt16-30363" + }, + "30364": { + "title": "Defrosting sensor (S135-BT76)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "defrosting-sensor-s135-bt76-30364" + }, + "30365": { + "title": "Incoming air (S135-BT77)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "incoming-air-s135-bt77-30365" + }, + "30366": { + "title": "Alarm number (S135)", + "factor": 1, + "size": "u16", + "name": "alarm-number-s135-30366" + }, + "30367": { + "title": "Defrosting (S135)", + "factor": 1, + "size": "u8", + "name": "defrosting-s135-30367" + }, + "30368": { + "title": "Status, relay 5 (S135)", + "factor": 1, + "size": "u8", + "name": "status-relay-5-s135-30368" + }, + "30369": { + "title": "Status, relay 4 (S135)", + "factor": 1, + "size": "u8", + "name": "status-relay-4-s135-30369" + }, + "30370": { + "title": "Status, relay 3 (S135)", + "factor": 1, + "size": "u8", + "name": "status-relay-3-s135-30370" + }, + "30371": { + "title": "Status, relay 2 (S135)", + "factor": 1, + "size": "u8", + "name": "status-relay-2-s135-30371" + }, + "30372": { + "title": "Status, relay 1 (S135)", + "factor": 1, + "size": "u8", + "name": "status-relay-1-s135-30372" + }, + "30373": { + "title": "Status, relay 0 (S135)", + "factor": 1, + "size": "u8", + "name": "status-relay-0-s135-30373" + }, + "30374": { + "title": "Pump speed (S135)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "pump-speed-s135-30374" + }, + "30375": { + "title": "Selected fan speed", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "selected-fan-speed-30375" + }, + "30377": { + "title": "Version (S135)", + "factor": 1, + "size": "u16", + "name": "version-s135-30377" + }, + "30393": { + "title": "Seconds of blank time left, charge pump 1", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-1-30393" + }, + "30394": { + "title": "Seconds of blank time left, charge pump 0", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-0-30394" + }, + "30401": { + "title": "Alarm number from outdoor air heat pump (EB101)", + "factor": 1, + "size": "u8", + "name": "alarm-number-from-outdoor-air-heat-pump-eb101-30401" + }, + "30402": { + "title": "Fan speed (EB101)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-speed-eb101-30402" + }, + "30403": { + "title": "Max fan speed (EB101)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb101-30403" + }, + "30404": { + "title": "Min fan speed (EB101)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb101-30404" + }, + "30405": { + "title": "Max compressor speed (EB101)", + "factor": 10, + "unit": "Hz", + "size": "u16", + "name": "max-compressor-speed-eb101-30405" + }, + "30406": { + "title": "Min compressor speed (EB101)", + "factor": 10, + "unit": "Hz", + "size": "u16", + "name": "min-compressor-speed-eb101-30406" + }, + "30407": { + "title": "Power (EB101)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "power-eb101-30407" + }, + "30408": { + "title": "Time to defrosting (EB101)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb101-30408" + }, + "30409": { + "title": "Defrosting index (EB101)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb101-30409" + }, + "30410": { + "title": "Superheat reference EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb101-30410" + }, + "30411": { + "title": "Superheat EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb101-30411" + }, + "30412": { + "title": "EEV-ssh-error (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb101-30412" + }, + "30413": { + "title": "Superheat temp. reference EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb101-30413" + }, + "30414": { + "title": "Set point value EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb101-30414" + }, + "30415": { + "title": "EEV PV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb101-30415" + }, + "30416": { + "title": "EEV-te-error average open (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb101-30416" + }, + "30417": { + "title": "Degree of opening EEV (EB101)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb101-30417" + }, + "30418": { + "title": "Superheat reference EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb101-30418" + }, + "30419": { + "title": "Superheat EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb101-30419" + }, + "30420": { + "title": "EEV-ssh-error (EVI)(EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb101-30420" + }, + "30421": { + "title": "Superheat temp. reference EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb101-30421" + }, + "30422": { + "title": "Set point value EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb101-30422" + }, + "30423": { + "title": "EVI PV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb101-30423" + }, + "30424": { + "title": "EEV-te-error average open in (EVI)(EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-in-evi-eb101-30424" + }, + "30425": { + "title": "Degree of opening EVI (EB101)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb101-30425" + }, + "30551": { + "title": "Low press (EB101 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb101-bp8-dew-30551" + }, + "30552": { + "title": "Hi press (EB101 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb101-bp9-dew-30552" + }, + "30553": { + "title": "Injection (EB101-BT81)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "injection-eb101-bt81-30553" + }, + "30554": { + "title": "Pressure sensor, injection (EB101-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb101-bp11-30554" + }, + "30555": { + "title": "EVI pressure (EB101-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb101-ep14-bp11-dew-30555" + }, + "30556": { + "title": "Evaporator (EB101-BT84)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-eb101-bt84-30556" + }, + "30557": { + "title": "Fan status (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb101-ep14-30557" + }, + "30558": { + "title": "Fan rpm (EB101-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb101-ep14-30558" + }, + "30576": { + "title": "High condenser out alarm (S135)", + "factor": 1, + "size": "u16", + "name": "high-condenser-out-alarm-s135-30576" + }, + "30577": { + "title": "High condenser in alarm (S135)", + "factor": 1, + "size": "u16", + "name": "high-condenser-in-alarm-s135-30577" + }, + "30579": { + "title": "Average current (EME 10)", + "factor": 10, + "unit": "A", + "size": "s16", + "name": "average-current-eme-10-30579" + }, + "30580": { + "title": "Operating mode PV panels", + "factor": 1, + "size": "u8", + "name": "operating-mode-pv-panels-30580" + }, + "30582": { + "title": "EME lux mode without EME", + "factor": 1, + "size": "u8", + "name": "eme-lux-mode-without-eme-30582" + }, + "30583": { + "title": "Timer (EME)", + "factor": 60, + "unit": "min", + "size": "u16", + "name": "timer-eme-30583" + }, + "30591": { + "title": "Fan mode 4", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-4-30591" + }, + "30592": { + "title": "Fan mode 3", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-3-30592" + }, + "30593": { + "title": "Fan mode 2", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-2-30593" + }, + "30594": { + "title": "Is the compressor accessible", + "factor": 1, + "size": "u8", + "name": "is-the-compressor-accessible-30594" + }, + "30605": { + "title": "Prio, hot water (OPT)", + "factor": 1, + "size": "u8", + "name": "prio-hot-water-opt-30605" + }, + "30684": { + "title": "Permit (undefined)", + "factor": 1, + "size": "u8", + "name": "permit-undefined-30684" + }, + "30685": { + "title": "Permit (undefined)", + "factor": 1, + "size": "u8", + "name": "permit-undefined-30685" + }, + "30686": { + "title": "Permit (undefined)", + "factor": 1, + "size": "u8", + "name": "permit-undefined-30686" + }, + "30687": { + "title": "Permit (OPT 10) additional heat", + "factor": 1, + "size": "u8", + "name": "permit-opt-10-additional-heat-30687" + }, + "30688": { + "title": "Permit ext. imm. heater step", + "factor": 1, + "size": "u8", + "name": "permit-ext-imm-heater-step-30688" + }, + "30689": { + "title": "Permit int. imm. heater step", + "factor": 1, + "size": "u8", + "name": "permit-int-imm-heater-step-30689" + }, + "30690": { + "title": "Permit shunted additional heat", + "factor": 1, + "size": "u8", + "name": "permit-shunted-additional-heat-30690" + }, + "30691": { + "title": "Permit prioritised additional heat", + "factor": 1, + "size": "u8", + "name": "permit-prioritised-additional-heat-30691" + }, + "30692": { + "title": "Permit (EB108-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb108-ep15-30692" + }, + "30693": { + "title": "Permit (EB107-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb107-ep15-30693" + }, + "30694": { + "title": "Permit (EB106-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb106-ep15-30694" + }, + "30695": { + "title": "Permit (EB105-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb105-ep15-30695" + }, + "30696": { + "title": "Permit (EB104-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb104-ep15-30696" + }, + "30697": { + "title": "Permit (EB103-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb103-ep15-30697" + }, + "30698": { + "title": "Permit (EB102-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb102-ep15-30698" + }, + "30699": { + "title": "Permit (EB101-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb101-ep15-30699" + }, + "30700": { + "title": "Permit (EB100-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb100-ep15-30700" + }, + "30701": { + "title": "Permit (EB108-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb108-ep14-30701" + }, + "30702": { + "title": "Permit (EB107-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb107-ep14-30702" + }, + "30703": { + "title": "Permit (EB106-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb106-ep14-30703" + }, + "30704": { + "title": "Permit (EB105-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb105-ep14-30704" + }, + "30705": { + "title": "Permit (EB104-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb104-ep14-30705" + }, + "30706": { + "title": "Permit (EB103-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb103-ep14-30706" + }, + "30707": { + "title": "Permit (EB102-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb102-ep14-30707" + }, + "30708": { + "title": "Permit (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb101-ep14-30708" + }, + "30709": { + "title": "Permit (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb100-ep14-30709" + }, + "30710": { + "title": "Smart energy source, priority 7, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-7-start-dm-30710" + }, + "30712": { + "title": "Smart energy source, priority 6, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-6-start-dm-30712" + }, + "30714": { + "title": "Smart energy source, priority 5, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-5-start-dm-30714" + }, + "30716": { + "title": "Smart energy source, priority 4, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-4-start-dm-30716" + }, + "30718": { + "title": "Smart energy source, priority 3, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-3-start-dm-30718" + }, + "30720": { + "title": "Smart energy source, priority 2, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-2-start-dm-30720" + }, + "30722": { + "title": "Smart energy source, priority 1, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-1-start-dm-30722" + }, + "30724": { + "title": "Smart energy source, priority 7, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-7-stop-dm-30724" + }, + "30726": { + "title": "Smart energy source, priority 6, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-6-stop-dm-30726" + }, + "30728": { + "title": "Smart energy source, priority 5, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-5-stop-dm-30728" + }, + "30730": { + "title": "Smart energy source, priority 4, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-4-stop-dm-30730" + }, + "30732": { + "title": "Smart energy source, priority 3, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-3-stop-dm-30732" + }, + "30734": { + "title": "Smart energy source, priority 2, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-2-stop-dm-30734" + }, + "30736": { + "title": "Smart energy source, priority 1, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-1-stop-dm-30736" + }, + "30738": { + "title": "Smart energy source, DM minimum value", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-dm-minimum-value-30738" + }, + "30746": { + "title": "External guide status", + "factor": 1, + "size": "u8", + "name": "external-guide-status-30746" + }, + "30747": { + "title": "Test guide value", + "factor": 1, + "size": "u16", + "name": "test-guide-value-30747" + }, + "30748": { + "title": "Temp. lux forces start of hot water demand", + "factor": 1, + "size": "u8", + "name": "temp-lux-forces-start-of-hot-water-demand-30748" + }, + "30758": { + "title": "Smart energy source, prio OPT10 for hot water", + "factor": 1, + "size": "u8", + "name": "smart-energy-source-prio-opt10-for-hot-water-30758" + }, + "30759": { + "title": "Smart energy source, Permit OPT to produce hot water", + "factor": 1, + "size": "u8", + "name": "smart-energy-source-permit-opt-to-produce-hot-water-30759" + }, + "30760": { + "title": "Wood boiler activated", + "factor": 1, + "size": "u8", + "name": "wood-boiler-activated-30760" + }, + "30768": { + "title": "Time to defrosting (EB108)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb108-30768" + }, + "30793": { + "title": "Time to defrosting (EB107)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb107-30793" + }, + "30818": { + "title": "Time to defrosting (EB106)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb106-30818" + }, + "30843": { + "title": "Time to defrosting (EB105)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb105-30843" + }, + "30868": { + "title": "Time to defrosting (EB104)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb104-30868" + }, + "30893": { + "title": "Time to defrosting (EB103)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb103-30893" + }, + "30918": { + "title": "Time to defrosting (EB102)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb102-30918" + }, + "30936": { + "title": "Alarm number (EB100)", + "factor": 1, + "size": "u8", + "name": "alarm-number-eb100-30936" + }, + "30937": { + "title": "Fan speed (EB100)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-speed-eb100-30937" + }, + "30938": { + "title": "Max fan speed (EB100)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb100-30938" + }, + "30939": { + "title": "Min fan speed (EB100)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb100-30939" + }, + "30940": { + "title": "Max compressor speed (EB100)", + "factor": 10, + "unit": "Hz", + "size": "u16", + "name": "max-compressor-speed-eb100-30940" + }, + "30941": { + "title": "Min compressor speed (EB100)", + "factor": 10, + "unit": "Hz", + "size": "u16", + "name": "min-compressor-speed-eb100-30941" + }, + "30942": { + "title": "Power (EB100)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "power-eb100-30942" + }, + "30943": { + "title": "Time to defrosting (EB100)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb100-30943" + }, + "30944": { + "title": "Defrosting index (EB100)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb100-30944" + }, + "30945": { + "title": "Superheat reference (EEV)(EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb100-30945" + }, + "30946": { + "title": "Superheat EEV (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb100-30946" + }, + "30947": { + "title": "EEV-ssh-error EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb100-30947" + }, + "30948": { + "title": "Superheat temp. reference (EEV)(EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb100-30948" + }, + "30949": { + "title": "Set point value EEV (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb100-30949" + }, + "30950": { + "title": "EEV PV (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb100-30950" + }, + "30951": { + "title": "EEV-te-error average open (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb100-30951" + }, + "30952": { + "title": "Opening degree EEV (EB100)", + "factor": 1, + "size": "u16", + "name": "opening-degree-eev-eb100-30952" + }, + "30953": { + "title": "Superheat reference EVI (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb100-30953" + }, + "30954": { + "title": "Superheat EVI (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb100-30954" + }, + "30955": { + "title": "EEV-ssh-error (EVI)(EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb100-30955" + }, + "30956": { + "title": "Superheat temp. reference (EVI)(EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb100-30956" + }, + "30957": { + "title": "Set point value EVI (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb100-30957" + }, + "30958": { + "title": "EVI PV (EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb100-30958" + }, + "30959": { + "title": "EEV-te-error average open (EVI)(EB100)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb100-30959" + }, + "30960": { + "title": "Opening degree EVI EB100)", + "factor": 1, + "size": "u16", + "name": "opening-degree-evi-eb100-30960" + }, + "30961": { + "title": "Wind speed, weather forecast", + "factor": 10, + "size": "u16", + "name": "wind-speed-weather-forecast-30961" + }, + "30962": { + "title": "Humidity, weather forecast", + "factor": 10, + "unit": "%", + "size": "u16", + "name": "humidity-weather-forecast-30962" + }, + "30963": { + "title": "Temperature, weather forecast", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-weather-forecast-30963" + }, + "30964": { + "title": "Temperature, weather data (forecast)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-weather-data-forecast-30964" + }, + "30992": { + "title": "Smart energy source, priority select. in hot water", + "factor": 1, + "size": "u8", + "name": "smart-energy-source-priority-select-in-hot-water-30992" + }, + "30993": { + "title": "Outd. air heat pump, inverter, limits", + "factor": 1, + "size": "u8", + "name": "outd-air-heat-pump-inverter-limits-30993" + }, + "30994": { + "title": "Outd. air heat pump, inverter, speed reducing", + "factor": 1, + "size": "u8", + "name": "outd-air-heat-pump-inverter-speed-reducing-30994" + }, + "31009": { + "title": "Has one phase (EB101)", + "factor": 1, + "size": "u8", + "name": "has-one-phase-eb101-31009" + }, + "31010": { + "title": "Serial index (EB101)", + "factor": 1, + "size": "u8", + "name": "serial-index-eb101-31010" + }, + "31012": { + "title": "Serial index (EB100)", + "factor": 1, + "size": "u8", + "name": "serial-index-eb100-31012" + }, + "31013": { + "title": "Alarm incompatible (heat pump)", + "factor": 1, + "size": "u16", + "name": "alarm-incompatible-heat-pump-31013" + }, + "40019": { + "title": "Limit DM", + "factor": 10, + "unit": "DM", + "size": "s16", + "min": -30000.0, + "max": 30000.0, + "default": 0.0, + "name": "limit-dm-40019", + "write": true + }, + "31018": { + "title": "Calculated supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "calculated-supply-climate-system-1-31018" + }, + "32196": { + "title": "Class 1 alarm", + "factor": 1, + "size": "u8", + "name": "class-1-alarm-32196" + }, + "31019": { + "title": "Frost protection status", + "factor": 1, + "size": "u16", + "name": "frost-protection-status-31019" + }, + "31020": { + "title": "Cooling status", + "factor": 1, + "size": "u8", + "name": "cooling-status-31020" + }, + "31026": { + "title": "Total run time additional heat", + "factor": 10, + "unit": "h", + "size": "s32", + "min": 0.0, + "max": 1000000.0, + "default": 0.0, + "name": "total-run-time-additional-heat-31026" + }, + "31028": { + "title": "Power internal additional heat", + "factor": 100, + "unit": "kW", + "size": "s16", + "name": "power-internal-additional-heat-31028" + }, + "31029": { + "title": "Priority", + "factor": 1, + "size": "u8", + "name": "priority-31029" + }, + "31030": { + "title": "Operating mode internal add. heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-internal-add-heat-31030" + }, + "31031": { + "title": "Oper. mode shunt climate system 4", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-4-31031" + }, + "31032": { + "title": "Oper. mode shunt climate system 3", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-3-31032" + }, + "31033": { + "title": "Oper. mode shunt climate system 2", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-2-31033" + }, + "31034": { + "title": "Oper. mode shunt climate system 1", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-1-31034" + }, + "31035": { + "title": "Operating. mode shunt controlled additional heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-shunt-controlled-additional-heat-31035" + }, + "31038": { + "title": "Fan mode 1", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-1-31038" + }, + "31039": { + "title": "Current hot water mode", + "factor": 1, + "size": "s8", + "name": "current-hot-water-mode-31039" + }, + "31054": { + "title": "Blocking cooling", + "factor": 1, + "size": "u8", + "name": "blocking-cooling-31054" + }, + "31055": { + "title": "External adjustment climate system 4", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-4-31055" + }, + "31056": { + "title": "External adjustment climate system 3", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-3-31056" + }, + "31057": { + "title": "External adjustment climate system 2", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-2-31057" + }, + "31058": { + "title": "External adjustment climate system 1", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-1-31058" + }, + "31059": { + "title": "External blocking", + "factor": 1, + "size": "u8", + "name": "external-blocking-31059" + }, + "31063": { + "title": "Step controlled add. heat blocking", + "factor": 1, + "size": "u8", + "name": "step-controlled-add-heat-blocking-31063" + }, + "31070": { + "title": "Total HW run time additional heat", + "factor": 10, + "unit": "h", + "size": "s32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "total-hw-run-time-additional-heat-31070" + }, + "31079": { + "title": "More hot water status", + "factor": 1, + "size": "u8", + "name": "more-hot-water-status-31079" + }, + "40020": { + "title": "Holiday function status", + "factor": 1, + "size": "s8", + "name": "holiday-function-status-40020", + "write": true + }, + "31103": { + "title": "Heating medium pump speed (GP1)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "heating-medium-pump-speed-gp1-31103" + }, + "31109": { + "title": "Docked compressors heating", + "factor": 1, + "size": "u8", + "name": "docked-compressors-heating-31109" + }, + "31110": { + "title": "Docked compressors hot water", + "factor": 1, + "size": "u8", + "name": "docked-compressors-hot-water-31110" + }, + "31111": { + "title": "Docked compressors pool 1", + "factor": 1, + "size": "u8", + "name": "docked-compressors-pool-1-31111" + }, + "32197": { + "title": "Reversing valve hot water (QN10)", + "factor": 1, + "size": "u8", + "name": "reversing-valve-hot-water-qn10-32197" + }, + "31116": { + "title": "Operating mode step controlled additional heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-step-controlled-additional-heat-31116" + }, + "31118": { + "title": "Relay status, base board (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "relay-status-base-board-eb100-ep14-31118" + }, + "31120": { + "title": "Relay status, imm. heat. board (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "relay-status-imm-heat-board-eb100-ep14-31120" + }, + "31121": { + "title": "Current status", + "factor": 1, + "size": "u32", + "name": "current-status-31121" + }, + "31123": { + "title": "Functionality, heat pump (EP14)", + "factor": 1, + "size": "u32", + "name": "functionality-heat-pump-ep14-31123" + }, + "31125": { + "title": "Active heat pumps", + "factor": 1, + "size": "u16", + "name": "active-heat-pumps-31125" + }, + "31126": { + "title": "Functionality, heat pump (EP15)", + "factor": 1, + "size": "u32", + "name": "functionality-heat-pump-ep15-31126" + }, + "31130": { + "title": "Operating mode HW comfort", + "factor": 1, + "size": "u8", + "name": "operating-mode-hw-comfort-31130" + }, + "31131": { + "title": "Operating mode HW comfort additional heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-hw-comfort-additional-heat-31131" + }, + "31133": { + "title": "Blocked", + "factor": 1, + "size": "u8", + "name": "blocked-31133" + }, + "31135": { + "title": "Pool 1 (QN19)", + "factor": 1, + "size": "u8", + "name": "pool-1-qn19-31135" + }, + "31452": { + "title": "Version (EB101)", + "factor": 1, + "size": "u16", + "name": "version-eb101-31452" + }, + "31453": { + "title": "Heat pump type (EB101)", + "factor": 1, + "size": "u8", + "name": "heat-pump-type-eb101-31453" + }, + "31454": { + "title": "Compressor size (EB101)", + "factor": 1, + "size": "u8", + "name": "compressor-size-eb101-31454" + }, + "31476": { + "title": "Return line (EB101-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-eb101-bt3-31476" + }, + "31479": { + "title": "Supply line (EB101-BT12)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-eb101-bt12-31479" + }, + "31480": { + "title": "Discharge (EB101-BT14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "discharge-eb101-bt14-31480" + }, + "31481": { + "title": "Liquid line (EB101-BT15)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "liquid-line-eb101-bt15-31481" + }, + "31482": { + "title": "Suction gas (EB101-BT17)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "suction-gas-eb101-bt17-31482" + }, + "31486": { + "title": "Compressor, time to start (EB101-EP14)", + "factor": 1, + "unit": "min", + "size": "u8", + "name": "compressor-time-to-start-eb101-ep14-31486" + }, + "31490": { + "title": "Compressor, number of starts (EB101-EP14)", + "factor": 1, + "size": "u32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-number-of-starts-eb101-ep14-31490" + }, + "31492": { + "title": "Compressor, oper. time, total (EB101-EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-oper-time-total-eb101-ep14-31492" + }, + "31494": { + "title": "Compressor, oper. time, hot water (EB101-EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-oper-time-hot-water-eb101-ep14-31494" + }, + "31496": { + "title": "Alarm number (EB101-EP14)", + "factor": 1, + "size": "u16", + "name": "alarm-number-eb101-ep14-31496" + }, + "31498": { + "title": "Heat pump type (EB100)", + "factor": 1, + "size": "u8", + "name": "heat-pump-type-eb100-31498" + }, + "31499": { + "title": "Compressor size (EB100)", + "factor": 1, + "size": "u8", + "name": "compressor-size-eb100-31499" + }, + "31557": { + "title": "Compressor, requested (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb101-ep14-31557" + }, + "31560": { + "title": "Cooling blocking", + "factor": 1, + "size": "u8", + "name": "cooling-blocking-31560" + }, + "31562": { + "title": "Date, periodic hot water", + "factor": 1, + "size": "u16", + "name": "date-periodic-hot-water-31562" + }, + "32175": { + "title": "Blocked compressors", + "factor": 1, + "size": "u32", + "name": "blocked-compressors-32175" + }, + "40021": { + "title": "Cooling degree minutes", + "factor": 10, + "unit": "DM", + "size": "s16", + "min": -30000.0, + "max": 30000.0, + "default": 0.0, + "name": "cooling-degree-minutes-40021", + "write": true + }, + "31576": { + "title": "Hot water, including int. add. heat", + "factor": 10, + "unit": "kWh", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "hot-water-including-int-add-heat-31576" + }, + "31578": { + "title": "Heating, including int. add. heat", + "factor": 10, + "unit": "kWh", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "heating-including-int-add-heat-31578" + }, + "31584": { + "title": "Hot water, compressor only", + "factor": 10, + "unit": "kWh", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "hot-water-compressor-only-31584" + }, + "31586": { + "title": "Heating, compressor only", + "factor": 10, + "unit": "kWh", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "heating-compressor-only-31586" + }, + "31590": { + "title": "Speed (GP12)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "speed-gp12-31590" + }, + "40022": { + "title": "Cooling pump manual speed", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "cooling-pump-manual-speed-40022", + "write": true + }, + "31622": { + "title": "Outdoor temperature (EB101-BT28)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "outdoor-temperature-eb101-bt28-31622" + }, + "31623": { + "title": "Evaporator (EB101-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-eb101-bt16-31623" + }, + "31637": { + "title": "Heating medium pump speed (GP1)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "heating-medium-pump-speed-gp1-31637" + }, + "31639": { + "title": "Frost protection heat exchanger heat pump 1", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-1-31639" + }, + "31694": { + "title": "Operating mode extra additional heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-extra-additional-heat-31694" + }, + "31695": { + "title": "Docked compressors cooling", + "factor": 1, + "size": "u8", + "name": "docked-compressors-cooling-31695" + }, + "31801": { + "title": "BP4, unprocessed (EB101-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb101-ep14-31801" + }, + "31803": { + "title": "Low pressure (EB101-BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb101-bp8-31803" + }, + "31804": { + "title": "Current compressor frequency (EB101)", + "factor": 10, + "unit": "Hz", + "size": "s16", + "name": "current-compressor-frequency-eb101-31804" + }, + "31805": { + "title": "Protection mode (EB101)", + "factor": 1, + "size": "u16", + "name": "protection-mode-eb101-31805" + }, + "31806": { + "title": "Defrosting (EB101)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb101-31806" + }, + "31807": { + "title": "Power (EB101-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb101-ep14-31807" + }, + "31823": { + "title": "Internal charge pump (GP12)", + "factor": 1, + "size": "u8", + "name": "internal-charge-pump-gp12-31823" + }, + "31824": { + "title": "Climate system 4", + "factor": 1, + "size": "u8", + "name": "climate-system-4-31824" + }, + "31825": { + "title": "Climate system 3", + "factor": 1, + "size": "u8", + "name": "climate-system-3-31825" + }, + "31826": { + "title": "Climate system 2", + "factor": 1, + "size": "u8", + "name": "climate-system-2-31826" + }, + "31827": { + "title": "Climate system 1 (HMP)", + "factor": 1, + "size": "u8", + "name": "climate-system-1-hmp-31827" + }, + "31829": { + "title": "Pool 1 pump status", + "factor": 1, + "size": "u8", + "name": "pool-1-pump-status-31829" + }, + "31855": { + "title": "Requested compressor frequency (EB101)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb101-31855" + }, + "31903": { + "title": "Low press. sensor, unprocessed (EB101-EP14)", + "factor": 1, + "size": "s16", + "name": "low-press-sensor-unprocessed-eb101-ep14-31903" + }, + "31904": { + "title": "Current sensor (EB101-EP14)", + "factor": 10, + "unit": "A", + "size": "s16", + "name": "current-sensor-eb101-ep14-31904" + }, + "31912": { + "title": "Operating mode (SG Ready)", + "factor": 1, + "size": "u8", + "name": "operating-mode-sg-ready-31912" + }, + "31913": { + "title": "SG ready, input A", + "factor": 1, + "size": "u8", + "name": "sg-ready-input-a-31913" + }, + "31914": { + "title": "SG ready, input B", + "factor": 1, + "size": "u8", + "name": "sg-ready-input-b-31914" + }, + "31915": { + "title": "Heating offset (SPA)", + "factor": 10, + "size": "s8", + "name": "heating-offset-spa-31915" + }, + "31916": { + "title": "Hot water comfort mode (SPA)", + "factor": 1, + "size": "s8", + "name": "hot-water-comfort-mode-spa-31916" + }, + "31917": { + "title": "Pool offset (SPA)", + "factor": 1, + "size": "s8", + "name": "pool-offset-spa-31917" + }, + "31918": { + "title": "Cooling offset (SPA)", + "factor": 1, + "size": "s8", + "name": "cooling-offset-spa-31918" + }, + "31919": { + "title": "Operating mode (Smart Price Adaption)", + "factor": 1, + "size": "u8", + "name": "operating-mode-smart-price-adaption-31919" + }, + "31967": { + "title": "Evaporator 2 (EB101-EP14-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-2-eb101-ep14-bt16-31967" + }, + "31968": { + "title": "Temperature, inverter (EB101-EP14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-inverter-eb101-ep14-31968" + }, + "31969": { + "title": "fan speed (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-speed-eb101-ep14-31969" + }, + "31970": { + "title": "Evaporator 2 (EB100-EP15-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-2-eb100-ep15-bt16-31970" + }, + "31971": { + "title": "Temperature, inverter (EB100-EP15)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-inverter-eb100-ep15-31971" + }, + "31972": { + "title": "fan speed (EB100-EP15)", + "factor": 1, + "size": "u8", + "name": "fan-speed-eb100-ep15-31972" + }, + "31973": { + "title": "Evaporator 2 (EB100-EP14-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-2-eb100-ep14-bt16-31973" + }, + "31974": { + "title": "Temperature, inverter (EB100-EP14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-inverter-eb100-ep14-31974" + }, + "31975": { + "title": "fan speed (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-speed-eb100-ep14-31975" + }, + "31976": { + "title": "Alarm number", + "factor": 1, + "size": "s16", + "name": "alarm-number-31976" + }, + "40023": { + "title": "Reset alarm", + "factor": 1, + "size": "u8", + "name": "reset-alarm-40023", + "write": true + }, + "31977": { + "title": "Non module-specific alarm numbers", + "factor": 1, + "size": "s16", + "name": "non-module-specific-alarm-numbers-31977" + }, + "40027": { + "title": "Heating curve climate system 1", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 15.0, + "default": 9.0, + "name": "heating-curve-climate-system-1-40027", + "write": true + }, + "40031": { + "title": "Heating offset climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "heating-offset-climate-system-1-40031", + "write": true + }, + "40035": { + "title": "Min supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 800.0, + "default": 200.0, + "name": "min-supply-climate-system-1-40035", + "write": true + }, + "40039": { + "title": "Max supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 800.0, + "default": 600.0, + "name": "max-supply-climate-system-1-40039", + "write": true + }, + "40040": { + "title": "Own curve, heating P7", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 15.0, + "name": "own-curve-heating-p7-40040", + "write": true + }, + "40041": { + "title": "Own curve, heating P6", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 15.0, + "name": "own-curve-heating-p6-40041", + "write": true + }, + "40042": { + "title": "Own curve, heating P5", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 26.0, + "name": "own-curve-heating-p5-40042", + "write": true + }, + "40043": { + "title": "Own curve, heating P4", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 32.0, + "name": "own-curve-heating-p4-40043", + "write": true + }, + "40044": { + "title": "Own curve, heating P3", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 35.0, + "name": "own-curve-heating-p3-40044", + "write": true + }, + "40045": { + "title": "Own curve, heating P2", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 40.0, + "name": "own-curve-heating-p2-40045", + "write": true + }, + "40046": { + "title": "Own curve, heating P1", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 45.0, + "name": "own-curve-heating-p1-40046", + "write": true + }, + "40047": { + "title": "Point offset outdoor temperature", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -40.0, + "max": 30.0, + "default": 0.0, + "name": "point-offset-outdoor-temperature-40047", + "write": true + }, + "40048": { + "title": "Point offset", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "point-offset-40048", + "write": true + }, + "40052": { + "title": "External adjustment climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-1-40052", + "write": true + }, + "40056": { + "title": "External adjustment with room sensor climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-1-40056", + "write": true + }, + "40057": { + "title": "Hot water demand mode", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 4.0, + "default": 1.0, + "name": "hot-water-demand-mode-40057", + "write": true + }, + "40059": { + "title": "Start temperature HW high temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 530.0, + "name": "start-temperature-hw-high-temperature-40059", + "write": true + }, + "40060": { + "title": "Start temperature HW normal temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 480.0, + "name": "start-temperature-hw-normal-temperature-40060", + "write": true + }, + "40061": { + "title": "Start temperature HW low temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 430.0, + "name": "start-temperature-hw-low-temperature-40061", + "write": true + }, + "40062": { + "title": "Stop temperature HW periodic increase", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 550.0, + "max": 700.0, + "default": 550.0, + "name": "stop-temperature-hw-periodic-increase-40062", + "write": true + }, + "40063": { + "title": "Stop temperature HW high temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 550.0, + "name": "stop-temperature-hw-high-temperature-40063", + "write": true + }, + "40064": { + "title": "Stop temperature HW normal temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 510.0, + "name": "stop-temperature-hw-normal-temperature-40064", + "write": true + }, + "40065": { + "title": "Stop temperature HW low temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 480.0, + "name": "stop-temperature-hw-low-temperature-40065", + "write": true + }, + "40066": { + "title": "Periodic hot water", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "periodic-hot-water-40066", + "write": true + }, + "40067": { + "title": "Periodic hot water interval", + "factor": 1, + "unit": "days", + "size": "s8", + "min": 1.0, + "max": 90.0, + "default": 7.0, + "name": "periodic-hot-water-interval-40067", + "write": true + }, + "40068": { + "title": "Start time periodic hot water", + "factor": 1, + "size": "u16", + "name": "start-time-periodic-hot-water-40068", + "write": true + }, + "40092": { + "title": "Language", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 22.0, + "default": 0.0, + "name": "language-40092", + "write": true + }, + "40093": { + "title": "Period time hot water", + "factor": 1, + "unit": "min", + "size": "u8", + "min": 0.0, + "max": 180.0, + "default": 30.0, + "name": "period-time-hot-water-40093", + "write": true + }, + "40094": { + "title": "Period time heating", + "factor": 1, + "unit": "min", + "size": "u8", + "min": 0.0, + "max": 180.0, + "default": 30.0, + "name": "period-time-heating-40094", + "write": true + }, + "42744": { + "title": "Operating mode", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 0.0, + "name": "operating-mode-42744", + "write": true + }, + "40096": { + "title": "Operating mode heating medium pump", + "factor": 1, + "size": "u8", + "min": 10.0, + "max": 40.0, + "default": 40.0, + "name": "operating-mode-heating-medium-pump-40096", + "write": true + }, + "45001": { + "title": "Activate force control", + "factor": 1, + "size": "u8", + "name": "activate-force-control-45001", + "write": true + }, + "40103": { + "title": "Max. internal additional heat", + "factor": 100, + "unit": "kW", + "size": "s16", + "min": 0.0, + "max": 4500.0, + "default": 900.0, + "name": "max-internal-additional-heat-40103", + "write": true + }, + "40104": { + "title": "Fuse", + "factor": 1, + "unit": "A", + "size": "u16", + "min": 1.0, + "max": 400.0, + "default": 16.0, + "name": "fuse-40104", + "write": true + }, + "40121": { + "title": "Floor drying", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "floor-drying-40121", + "write": true + }, + "40122": { + "title": "Floor drying period 7", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-7-40122", + "write": true + }, + "40123": { + "title": "Floor drying period 6", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-6-40123", + "write": true + }, + "40124": { + "title": "Floor drying period 5", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-5-40124", + "write": true + }, + "40125": { + "title": "Floor drying period 4", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 3.0, + "name": "floor-drying-period-4-40125", + "write": true + }, + "40126": { + "title": "Floor drying period 3", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-3-40126", + "write": true + }, + "40127": { + "title": "Floor drying period 2", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-2-40127", + "write": true + }, + "40128": { + "title": "Floor drying period 1", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-1-40128", + "write": true + }, + "40129": { + "title": "Floor drying temp. 7", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 20.0, + "name": "floor-drying-temp-7-40129", + "write": true + }, + "40130": { + "title": "Floor drying temp. 6", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 30.0, + "name": "floor-drying-temp-6-40130", + "write": true + }, + "40131": { + "title": "Floor drying temp. 5", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 40.0, + "name": "floor-drying-temp-5-40131", + "write": true + }, + "40132": { + "title": "Floor drying temp. 4", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 45.0, + "name": "floor-drying-temp-4-40132", + "write": true + }, + "40133": { + "title": "Floor drying temp. 3", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 40.0, + "name": "floor-drying-temp-3-40133", + "write": true + }, + "40134": { + "title": "Floor drying temp. 2", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 30.0, + "name": "floor-drying-temp-2-40134", + "write": true + }, + "40135": { + "title": "Floor drying temp. 1", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 20.0, + "name": "floor-drying-temp-1-40135", + "write": true + }, + "31978": { + "title": "Floor drying ongoing time.", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 0.0, + "name": "floor-drying-ongoing-time-31978" + }, + "40141": { + "title": "Dimensioned outdoor temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -400.0, + "max": 200.0, + "default": -180.0, + "name": "dimensioned-outdoor-temperature-40141", + "write": true + }, + "40142": { + "title": "Delta T for DOT", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 100.0, + "name": "delta-t-for-dot-40142", + "write": true + }, + "40143": { + "title": "Climate system 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-2-40143", + "write": true + }, + "40144": { + "title": "Climate system 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-3-40144", + "write": true + }, + "40145": { + "title": "Climate system 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-4-40145", + "write": true + }, + "40154": { + "title": "Shunt controlled additional heat", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "shunt-controlled-additional-heat-40154", + "write": true + }, + "40158": { + "title": "Wait time shunt, shunt controlled additional heat", + "factor": 1, + "unit": "s", + "size": "s16", + "min": 10.0, + "max": 300.0, + "default": 30.0, + "name": "wait-time-shunt-shunt-controlled-additional-heat-40158", + "write": true + }, + "40159": { + "title": "Step controlled additional heat accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "step-controlled-additional-heat-accessory-40159", + "write": true + }, + "40160": { + "title": "DM start step controlled additional heat", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": -2000.0, + "max": -30.0, + "default": -400.0, + "name": "dm-start-step-controlled-additional-heat-40160", + "write": true + }, + "40166": { + "title": "Waiting time cooling/heating", + "factor": 1, + "unit": "h", + "size": "s8", + "min": 0.0, + "max": 48.0, + "default": 2.0, + "name": "waiting-time-cooling-heating-40166", + "write": true + }, + "40167": { + "title": "Heating start at under temp.", + "factor": 10, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 100.0, + "default": 10.0, + "name": "heating-start-at-under-temp-40167", + "write": true + }, + "40168": { + "title": "Cooling start at over temp.", + "factor": 10, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 100.0, + "default": 30.0, + "name": "cooling-start-at-over-temp-40168", + "write": true + }, + "40171": { + "title": "Cooling with room sensors", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 41.0, + "default": 0.0, + "name": "cooling-with-room-sensors-40171", + "write": true + }, + "40174": { + "title": "Start active cooling DM", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 10.0, + "max": 300.0, + "default": 30.0, + "name": "start-active-cooling-dm-40174", + "write": true + }, + "40181": { + "title": "Permit additional heat, heating", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "permit-additional-heat-heating-40181", + "write": true + }, + "40182": { + "title": "Permit heating", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "permit-heating-40182", + "write": true + }, + "40183": { + "title": "Permit cooling", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "permit-cooling-40183", + "write": true + }, + "40184": { + "title": "Auto mode, start temperature for cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 150.0, + "max": 400.0, + "default": 250.0, + "name": "auto-mode-start-temperature-for-cooling-40184", + "write": true + }, + "40185": { + "title": "Auto mode, stop temperature for heating", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -200.0, + "max": 400.0, + "default": 170.0, + "name": "auto-mode-stop-temperature-for-heating-40185", + "write": true + }, + "40186": { + "title": "Auto mode, additional heat stop temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -250.0, + "max": 400.0, + "default": 50.0, + "name": "auto-mode-additional-heat-stop-temperature-40186", + "write": true + }, + "40187": { + "title": "Auto mode filter time", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 0.0, + "max": 48.0, + "default": 24.0, + "name": "auto-mode-filter-time-40187", + "write": true + }, + "40188": { + "title": "Max difference supply, compressor", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 100.0, + "name": "max-difference-supply-compressor-40188", + "write": true + }, + "40189": { + "title": "Max difference supply, additional heat", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 240.0, + "default": 70.0, + "name": "max-difference-supply-additional-heat-40189", + "write": true + }, + "40195": { + "title": "Time format", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "time-format-40195", + "write": true + }, + "40197": { + "title": "Alarm action, lower room temperature", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "alarm-action-lower-room-temperature-40197", + "write": true + }, + "40198": { + "title": "Alarm action lower HW temperature", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "alarm-action-lower-hw-temperature-40198", + "write": true + }, + "40199": { + "title": "Auxiliary operation on alarm", + "factor": 1, + "size": "u8", + "name": "auxiliary-operation-on-alarm-40199", + "write": true + }, + "40200": { + "title": "Use room sensor climate system 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-4-40200", + "write": true + }, + "40201": { + "title": "Use room sensor climate system 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-3-40201", + "write": true + }, + "40202": { + "title": "Use room sensor climate system 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-2-40202", + "write": true + }, + "40203": { + "title": "Use room sensor climate system 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-1-40203", + "write": true + }, + "40204": { + "title": "Room sensor set point value climate system 4", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-4-40204", + "write": true + }, + "40205": { + "title": "Room sensor set point value climate system 3", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-3-40205", + "write": true + }, + "40206": { + "title": "Room sensor set point value climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-2-40206", + "write": true + }, + "40207": { + "title": "Room sensor set point value climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-1-40207", + "write": true + }, + "40208": { + "title": "Room sensor factor climate system 4", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-4-40208", + "write": true + }, + "40209": { + "title": "Room sensor factor climate system 3", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-3-40209", + "write": true + }, + "40210": { + "title": "Room sensor factor climate system 2", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-2-40210", + "write": true + }, + "40211": { + "title": "Room sensor factor climate system 1", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-1-40211", + "write": true + }, + "40212": { + "title": "Input AUX5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "input-aux5-40212", + "write": true + }, + "40213": { + "title": "Input AUX4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "input-aux4-40213", + "write": true + }, + "40214": { + "title": "Input AUX3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "input-aux3-40214", + "write": true + }, + "40215": { + "title": "Input AUX2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "input-aux2-40215", + "write": true + }, + "40216": { + "title": "Input AUX1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "input-aux1-40216", + "write": true + }, + "40217": { + "title": "Output AUX1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 26.0, + "default": 0.0, + "name": "output-aux1-40217", + "write": true + }, + "40224": { + "title": "Preset flow setting for climate system", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 3.0, + "default": 1.0, + "name": "preset-flow-setting-for-climate-system-40224", + "write": true + }, + "40226": { + "title": "More hot water", + "factor": 10, + "size": "u16", + "name": "more-hot-water-40226", + "write": true + }, + "40238": { + "title": "Oper. mode", + "factor": 1, + "size": "u8", + "name": "oper-mode-40238", + "write": true + }, + "40682": { + "title": "Cooling heat sensor set point value", + "factor": 10, + "size": "s16", + "min": 50.0, + "max": 400.0, + "default": 210.0, + "name": "cooling-heat-sensor-set-point-value-40682", + "write": true + }, + "40686": { + "title": "Pool 1 accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pool-1-accessory-40686", + "write": true + }, + "40695": { + "title": "Hot water comfort", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hot-water-comfort-40695", + "write": true + }, + "40698": { + "title": "More hot water", + "factor": 1, + "size": "s8", + "name": "more-hot-water-40698", + "write": true + }, + "40704": { + "title": "Start diff. DM, step-controlled add. heat", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 0.0, + "max": 2000.0, + "default": 400.0, + "name": "start-diff-dm-step-controlled-add-heat-40704", + "write": true + }, + "40706": { + "title": "HW comfort shunt on/off", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hw-comfort-shunt-on-off-40706", + "write": true + }, + "40710": { + "title": "External cooling accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-cooling-accessory-40710", + "write": true + }, + "40727": { + "title": "Cooling connected, climate system 1", + "factor": 1, + "size": "u8", + "name": "cooling-connected-climate-system-1-40727", + "write": true + }, + "40749": { + "title": "Operating mode charge pump climate system 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "operating-mode-charge-pump-climate-system-1-40749", + "write": true + }, + "44065": { + "title": "Shunted brine, accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "shunted-brine-accessory-44065", + "write": true + }, + "44068": { + "title": "Shunted brine max. temp.", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 20.0, + "name": "shunted-brine-max-temp-44068", + "write": true + }, + "40761": { + "title": "Heating (SG Ready)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-sg-ready-40761", + "write": true + }, + "40768": { + "title": "Input AUX5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "input-aux5-40768", + "write": true + }, + "40784": { + "title": "Operating mode circulation pump heating heat pump 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "operating-mode-circulation-pump-heating-heat-pump-1-40784", + "write": true + }, + "40800": { + "title": "Operating mode circulation pump hot water heat pump 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "operating-mode-circulation-pump-hot-water-heat-pump-1-40800", + "write": true + }, + "40842": { + "title": "Speed circulation pump waiting mode heat pump 1", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 30.0, + "name": "speed-circulation-pump-waiting-mode-heat-pump-1-40842", + "write": true + }, + "40843": { + "title": "Speed, circulation pump, standby mode (EB100)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 30.0, + "name": "speed-circulation-pump-standby-mode-eb100-40843", + "write": true + }, + "40844": { + "title": "Activated (Smart Price Adaption)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "activated-smart-price-adaption-40844", + "write": true + }, + "40850": { + "title": "(SPA), cooling activated", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "spa-cooling-activated-40850", + "write": true + }, + "40852": { + "title": "(SPA), area", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 254.0, + "default": 23.0, + "name": "spa-area-40852", + "write": true + }, + "40868": { + "title": "Max. speed controlled charge pump (EB101)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 80.0, + "max": 100.0, + "default": 100.0, + "name": "max-speed-controlled-charge-pump-eb101-40868", + "write": true + }, + "40894": { + "title": "External adjustment climate system 8", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-8-40894", + "write": true + }, + "40895": { + "title": "External adjustment climate system 7", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-7-40895", + "write": true + }, + "40896": { + "title": "External adjustment climate system 6", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-6-40896", + "write": true + }, + "40897": { + "title": "External adjustment climate system 5", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-5-40897", + "write": true + }, + "40898": { + "title": "External adjustment with room sensor climate system 8", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-8-40898", + "write": true + }, + "40899": { + "title": "External adjustment with room sensor climate system 7", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-7-40899", + "write": true + }, + "40900": { + "title": "External adjustment with room sensor climate system 6", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-6-40900", + "write": true + }, + "40901": { + "title": "External adjustment with room sensor climate system 5", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-5-40901", + "write": true + }, + "40906": { + "title": "Climate system 5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-5-40906", + "write": true + }, + "40907": { + "title": "Climate system 6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-6-40907", + "write": true + }, + "40908": { + "title": "Climate system 7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-7-40908", + "write": true + }, + "40909": { + "title": "Climate system 8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-8-40909", + "write": true + }, + "40933": { + "title": "Heating connected, climate system 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-connected-climate-system-1-40933", + "write": true + }, + "40934": { + "title": "ERS 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-1-40934", + "write": true + }, + "40949": { + "title": "Use room sensor climate system 8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-8-40949", + "write": true + }, + "40950": { + "title": "Use room sensor climate system 7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-7-40950", + "write": true + }, + "40951": { + "title": "Use room sensor climate system 6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-6-40951", + "write": true + }, + "40952": { + "title": "Use room sensor climate system 5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-5-40952", + "write": true + }, + "40953": { + "title": "Room sensor set point value climate system 8", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-8-40953", + "write": true + }, + "40954": { + "title": "Room sensor set point value climate system 7", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-7-40954", + "write": true + }, + "40955": { + "title": "Room sensor set point value climate system 6", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-6-40955", + "write": true + }, + "40956": { + "title": "Room sensor set point value climate system 5", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-5-40956", + "write": true + }, + "40957": { + "title": "Room sensor factor climate system 8", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-8-40957", + "write": true + }, + "40958": { + "title": "Room sensor factor climate system 7", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-7-40958", + "write": true + }, + "40959": { + "title": "Room sensor factor climate system 6", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-6-40959", + "write": true + }, + "40960": { + "title": "Room sensor factor climate system 5", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-5-40960", + "write": true + }, + "40981": { + "title": "Current transformer ratio", + "factor": 1, + "size": "u16", + "min": 300.0, + "max": 3000.0, + "default": 300.0, + "name": "current-transformer-ratio-40981", + "write": true + }, + "40982": { + "title": "Room sensor set point value climate system 8, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-8-cooling-40982", + "write": true + }, + "40983": { + "title": "Room sensor set point value climate system 7, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-7-cooling-40983", + "write": true + }, + "40984": { + "title": "Room sensor set point value climate system 6, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-6-cooling-40984", + "write": true + }, + "40985": { + "title": "Room sensor set point value climate system 5, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-5-cooling-40985", + "write": true + }, + "40986": { + "title": "Room sensor set point value climate system 4, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-4-cooling-40986", + "write": true + }, + "40987": { + "title": "Room sensor set point value climate system 3, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-3-cooling-40987", + "write": true + }, + "40988": { + "title": "Room sensor set point value climate system 2, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-2-cooling-40988", + "write": true + }, + "40989": { + "title": "Room sensor set point value climate system 1, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-1-cooling-40989", + "write": true + }, + "40990": { + "title": "Room sensor factor climate system 8, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-8-cooling-40990", + "write": true + }, + "40991": { + "title": "Room sensor factor climate system 7, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-7-cooling-40991", + "write": true + }, + "40992": { + "title": "Room sensor factor climate system 6, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-6-cooling-40992", + "write": true + }, + "40993": { + "title": "Room sensor factor climate system 5, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-5-cooling-40993", + "write": true + }, + "40994": { + "title": "Room sensor factor climate system 4, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-4-cooling-40994", + "write": true + }, + "40995": { + "title": "Room sensor factor climate system 3, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-3-cooling-40995", + "write": true + }, + "40996": { + "title": "Room sensor factor climate system 2, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-2-cooling-40996", + "write": true + }, + "40997": { + "title": "Room sensor factor climate system 1, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-1-cooling-40997", + "write": true + }, + "40998": { + "title": "Set point value (RH)", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 30.0, + "max": 90.0, + "default": 60.0, + "name": "set-point-value-rh-40998", + "write": true + }, + "40999": { + "title": "HTS 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-1-40999", + "write": true + }, + "41016": { + "title": "OPT", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "opt-41016", + "write": true + }, + "41017": { + "title": "DM start difference (OPT)", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 10.0, + "max": 2000.0, + "default": 700.0, + "name": "dm-start-difference-opt-41017", + "write": true + }, + "41022": { + "title": "Exhaust air fan speed 4 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 100.0, + "name": "exhaust-air-fan-speed-4-ers-1-41022", + "write": true + }, + "41023": { + "title": "Exhaust air fan speed 3 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 80.0, + "name": "exhaust-air-fan-speed-3-ers-1-41023", + "write": true + }, + "41024": { + "title": "Exhaust air fan speed 2 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 30.0, + "name": "exhaust-air-fan-speed-2-ers-1-41024", + "write": true + }, + "41025": { + "title": "Exhaust air fan speed 1 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 0.0, + "name": "exhaust-air-fan-speed-1-ers-1-41025", + "write": true + }, + "41026": { + "title": "Exhaust air fan speed normal (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 75.0, + "name": "exhaust-air-fan-speed-normal-ers-1-41026", + "write": true + }, + "41036": { + "title": "S135", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "s135-41036", + "write": true + }, + "41037": { + "title": "Pump speed (S135)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "pump-speed-s135-41037", + "write": true + }, + "41045": { + "title": "Bypass temp. (ERS 1)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 2.0, + "max": 10.0, + "default": 4.0, + "name": "bypass-temp-ers-1-41045", + "write": true + }, + "41046": { + "title": "Pool pump type", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "pool-pump-type-41046", + "write": true + }, + "41047": { + "title": "External cooling accessory pump type", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "external-cooling-accessory-pump-type-41047", + "write": true + }, + "41050": { + "title": "Flow sensor activated X22", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "flow-sensor-activated-x22-41050", + "write": true + }, + "41053": { + "title": "Max. internal additional heat SG Ready", + "factor": 100, + "unit": "kW", + "size": "s16", + "min": 0.0, + "max": 900.0, + "default": 900.0, + "name": "max-internal-additional-heat-sg-ready-41053", + "write": true + }, + "41067": { + "title": "Hysteresis (OPT)", + "factor": 1, + "size": "s16", + "min": 10.0, + "max": 2000.0, + "default": 100.0, + "name": "hysteresis-opt-41067", + "write": true + }, + "41069": { + "title": "Activated (EME10)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "activated-eme10-41069", + "write": true + }, + "41070": { + "title": "PV panel affects heating (EME)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pv-panel-affects-heating-eme-41070", + "write": true + }, + "41071": { + "title": "PV panel affects hot water (EME)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pv-panel-affects-hot-water-eme-41071", + "write": true + }, + "41072": { + "title": "Delay timer EME", + "factor": 1, + "size": "u16", + "name": "delay-timer-eme-41072", + "write": true + }, + "41096": { + "title": "AUX blocking (OPT)", + "factor": 1, + "size": "u8", + "name": "aux-blocking-opt-41096", + "write": true + }, + "41097": { + "title": "Outdoor air mixing", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "outdoor-air-mixing-41097", + "write": true + }, + "41103": { + "title": "Smart home room control", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "smart-home-room-control-41103", + "write": true + }, + "41106": { + "title": "Smart Energy Source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "smart-energy-source-41106", + "write": true + }, + "41107": { + "title": "Control method, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "control-method-smart-energy-source-41107", + "write": true + }, + "41108": { + "title": "El. price, special, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 0.0, + "name": "el-price-special-smart-energy-source-41108", + "write": true + }, + "41109": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41109", + "write": true + }, + "41110": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41110", + "write": true + }, + "41111": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41111", + "write": true + }, + "41112": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41112", + "write": true + }, + "41113": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41113", + "write": true + }, + "41114": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41114", + "write": true + }, + "41115": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41115", + "write": true + }, + "41116": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41116", + "write": true + }, + "41117": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41117", + "write": true + }, + "41118": { + "title": "Prim. factor, smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 25.0, + "name": "prim-factor-smart-energy-source-41118", + "write": true + }, + "41119": { + "title": "Prim. factor, shunt add. heat smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 10.0, + "name": "prim-factor-shunt-add-heat-smart-energy-source-41119", + "write": true + }, + "41120": { + "title": "Prim. factor, ext. step add. heat smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 10.0, + "name": "prim-factor-ext-step-add-heat-smart-energy-source-41120", + "write": true + }, + "41121": { + "title": "Prim. factor, OPT10 smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 10.0, + "name": "prim-factor-opt10-smart-energy-source-41121", + "write": true + }, + "41122": { + "title": "OPT10, high tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "opt10-high-tariff-price-smart-energy-source-41122", + "write": true + }, + "41123": { + "title": "OPT10, low tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "opt10-low-tariff-price-smart-energy-source-41123", + "write": true + }, + "41124": { + "title": "ext. step add. heat, high tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "ext-step-add-heat-high-tariff-price-smart-energy-source-41124", + "write": true + }, + "41125": { + "title": "ext. step add. heat, low tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "ext-step-add-heat-low-tariff-price-smart-energy-source-41125", + "write": true + }, + "41126": { + "title": "Shunt add. heat, high tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "shunt-add-heat-high-tariff-price-smart-energy-source-41126", + "write": true + }, + "41127": { + "title": "Shunt add. heat, low tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "shunt-add-heat-low-tariff-price-smart-energy-source-41127", + "write": true + }, + "41128": { + "title": "El. price, fixed, high tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-high-tariff-smart-energy-source-41128", + "write": true + }, + "41129": { + "title": "El. price, fixed, low tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-low-tariff-smart-energy-source-41129", + "write": true + }, + "41130": { + "title": "El. price, variable, high tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-variable-high-tariff-smart-energy-source-41130", + "write": true + }, + "41131": { + "title": "El. price, variable, low tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-variable-low-tariff-smart-energy-source-41131", + "write": true + }, + "41132": { + "title": "DM start source, priority 5 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-5-smart-energy-source-41132", + "write": true + }, + "41133": { + "title": "DM start source, priority 4 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-4-smart-energy-source-41133", + "write": true + }, + "41134": { + "title": "DM start source, priority 3 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-3-smart-energy-source-41134", + "write": true + }, + "41135": { + "title": "DM start source, priority 2 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-2-smart-energy-source-41135", + "write": true + }, + "41136": { + "title": "DM start source, priority 1 smart energy source", + "factor": 1, + "size": "s16", + "min": -2000.0, + "max": -10.0, + "default": -60.0, + "name": "dm-start-source-priority-1-smart-energy-source-41136", + "write": true + }, + "41137": { + "title": "Start day, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-smart-energy-source-41137", + "write": true + }, + "41138": { + "title": "End day, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-smart-energy-source-41138", + "write": true + }, + "41139": { + "title": "Start month, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-smart-energy-source-41139", + "write": true + }, + "41140": { + "title": "End month, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-smart-energy-source-41140", + "write": true + }, + "41173": { + "title": "Start day, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-fixed-tariff-smart-energy-source-41173", + "write": true + }, + "41174": { + "title": "End day, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-fixed-tariff-smart-energy-source-41174", + "write": true + }, + "41175": { + "title": "Start month, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-fixed-tariff-smart-energy-source-41175", + "write": true + }, + "41176": { + "title": "End month, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-fixed-tariff-smart-energy-source-41176", + "write": true + }, + "41209": { + "title": "Start day, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-opt10-smart-energy-source-41209", + "write": true + }, + "41210": { + "title": "End day, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-opt10-smart-energy-source-41210", + "write": true + }, + "41211": { + "title": "Start month, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-opt10-smart-energy-source-41211", + "write": true + }, + "41212": { + "title": "End month, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-opt10-smart-energy-source-41212", + "write": true + }, + "41245": { + "title": "Start day tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-shunt-additional-heat-smart-energy-source-41245", + "write": true + }, + "41246": { + "title": "End day tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-shunt-additional-heat-smart-energy-source-41246", + "write": true + }, + "41247": { + "title": "Start month tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-shunt-additional-heat-smart-energy-source-41247", + "write": true + }, + "41248": { + "title": "End month tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-shunt-additional-heat-smart-energy-source-41248", + "write": true + }, + "41281": { + "title": "Start day tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-ext-step-add-heat-smart-energy-source-41281", + "write": true + }, + "41282": { + "title": "End day tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-ext-step-add-heat-smart-energy-source-41282", + "write": true + }, + "41283": { + "title": "Start month tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-ext-step-add-heat-smart-energy-source-41283", + "write": true + }, + "41284": { + "title": "End month tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-ext-step-add-heat-smart-energy-source-41284", + "write": true + }, + "41321": { + "title": "Prioritise additional heat (AXC40)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "prioritise-additional-heat-axc40-41321", + "write": true + }, + "41327": { + "title": "Max difference, SES priority 1 energy source", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 100.0, + "name": "max-difference-ses-priority-1-energy-source-41327", + "write": true + }, + "41328": { + "title": "Max difference, SES lower priority energy source", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 70.0, + "name": "max-difference-ses-lower-priority-energy-source-41328", + "write": true + }, + "41551": { + "title": "Installed (EB101)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "installed-eb101-41551", + "write": true + }, + "44001": { + "title": "EME20", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eme20-44001", + "write": true + }, + "32177": { + "title": "Current power", + "factor": 1, + "unit": "W", + "size": "u32", + "name": "current-power-32177" + }, + "32179": { + "title": "Total average power (EME 20)", + "factor": 100, + "unit": "kW", + "size": "u32", + "name": "total-average-power-eme-20-32179" + }, + "32181": { + "title": "Total energy", + "factor": 10, + "unit": "kWh", + "size": "s32", + "name": "total-energy-32181" + }, + "44077": { + "title": "ERS 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-2-44077", + "write": true + }, + "44078": { + "title": "ERS 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-3-44078", + "write": true + }, + "44079": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-4-44079", + "write": true + }, + "41982": { + "title": "HTS 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-2-41982", + "write": true + }, + "41983": { + "title": "HTS 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-3-41983", + "write": true + }, + "41984": { + "title": "HTS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-4-41984", + "write": true + }, + "44139": { + "title": "External adjustment, cooling climate system 8", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-8-44139", + "write": true + }, + "44140": { + "title": "External adjustment, cooling climate system 7", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-7-44140", + "write": true + }, + "44141": { + "title": "External adjustment, cooling climate system 6", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-6-44141", + "write": true + }, + "44142": { + "title": "External adjustment, cooling climate system 5", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-5-44142", + "write": true + }, + "44143": { + "title": "External adjustment, cooling climate system 4", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-4-44143", + "write": true + }, + "44144": { + "title": "External adjustment, cooling climate system 3", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-3-44144", + "write": true + }, + "44145": { + "title": "External adjustment, cooling climate system 2", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-2-44145", + "write": true + }, + "44146": { + "title": "External adjustment, cooling climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-1-44146", + "write": true + }, + "44147": { + "title": "External adjustment with room sensor, cooling climate system 8", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-8-44147", + "write": true + }, + "44148": { + "title": "External adjustment with room sensor, cooling climate system 7", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-7-44148", + "write": true + }, + "44149": { + "title": "External adjustment with room sensor, cooling climate system 6", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-6-44149", + "write": true + }, + "44150": { + "title": "External adjustment with room sensor, cooling climate system 5", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-5-44150", + "write": true + }, + "44151": { + "title": "External adjustment with room sensor, cooling climate system 4", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-4-44151", + "write": true + }, + "44152": { + "title": "External adjustment with room sensor, cooling climate system 3", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-3-44152", + "write": true + }, + "44153": { + "title": "External adjustment with room sensor, cooling climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-2-44153", + "write": true + }, + "44154": { + "title": "External adjustment with room sensor, cooling climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-1-44154", + "write": true + }, + "32178": { + "title": "Current power", + "factor": 100, + "unit": "kW", + "size": "u32", + "name": "current-power-32178" + }, + "44165": { + "title": "BlockFreq 1 (EB102)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb102-44165", + "write": true + }, + "44166": { + "title": "BlockFreq 1 (EB103)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb103-44166", + "write": true + }, + "44167": { + "title": "BlockFreq 1 (EB104)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb104-44167", + "write": true + }, + "44168": { + "title": "BlockFreq 1 (EB105)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb105-44168", + "write": true + }, + "44169": { + "title": "BlockFreq 1 (EB106)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb106-44169", + "write": true + }, + "44170": { + "title": "BlockFreq 1 (EB107)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb107-44170", + "write": true + }, + "44171": { + "title": "BlockFreq 1 (EB108)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb108-44171", + "write": true + }, + "44201": { + "title": "Power at DOT, manual value", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "power-at-dot-manual-value-44201", + "write": true + }, + "44101": { + "title": "Blocking actions (ERS 3)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-3-44101", + "write": true + }, + "44102": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-44102", + "write": true + }, + "42956": { + "title": "Night cooling 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "night-cooling-1-42956", + "write": true + }, + "42943": { + "title": "Start temperature night cooling 1", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 20.0, + "max": 30.0, + "default": 25.0, + "name": "start-temperature-night-cooling-1-42943", + "write": true + }, + "42944": { + "title": "Night cooling diff", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 3.0, + "max": 10.0, + "default": 6.0, + "name": "night-cooling-diff-42944", + "write": true + }, + "43244": { + "title": "Minimum permitted speed (EB101 GP12)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 50.0, + "default": 1.0, + "name": "minimum-permitted-speed-eb101-gp12-43244", + "write": true + }, + "43252": { + "title": "Start fan de-icing (EB101)", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "start-fan-de-icing-eb101-43252", + "write": true + }, + "40177": { + "title": "System 1 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-1-rmu-40177", + "write": true + }, + "40178": { + "title": "System 2 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-2-rmu-40178", + "write": true + }, + "40179": { + "title": "System 3 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-3-rmu-40179", + "write": true + }, + "40180": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-40180", + "write": true + }, + "41999": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-41999", + "write": true + }, + "42000": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-42000", + "write": true + }, + "42001": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-42001", + "write": true + }, + "42002": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-42002", + "write": true + }, + "42743": { + "title": "The start guide has been run", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "the-start-guide-has-been-run-42743", + "write": true + }, + "43233": { + "title": "Audio signal on alarm", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "audio-signal-on-alarm-43233", + "write": true + }, + "43234": { + "title": "Sound when pressing button", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "sound-when-pressing-button-43234", + "write": true + }, + "43235": { + "title": "BT12 offset, heat pump 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s8", + "min": -50.0, + "max": 50.0, + "default": 0.0, + "name": "bt12-offset-heat-pump-1-43235", + "write": true + }, + "43060": { + "title": "Heating, auto", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-auto-43060", + "write": true + }, + "43034": { + "title": "Factor", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 10.0, + "default": 5.0, + "name": "factor-43034", + "write": true + }, + "32015": { + "title": "Hot water start (BT5)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-start-bt5-32015" + }, + "32129": { + "title": "Pump: Heating medium (GP6)", + "factor": 1, + "size": "u8", + "name": "pump-heating-medium-gp6-32129" + }, + "43089": { + "title": "Period", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "period-43089", + "write": true + }, + "43090": { + "title": "Number of years", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 5.0, + "default": 1.0, + "name": "number-of-years-43090", + "write": true + }, + "43091": { + "title": "Months", + "factor": 1, + "size": "u32", + "min": 0.0, + "max": 4095.0, + "default": 4095.0, + "name": "months-43091", + "write": true + }, + "43097": { + "title": "Show outdoor temperature", + "factor": 1, + "size": "u8", + "name": "show-outdoor-temperature-43097", + "write": true + }, + "43098": { + "title": "Show indoor temperature", + "factor": 1, + "size": "u8", + "name": "show-indoor-temperature-43098", + "write": true + }, + "43067": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43067", + "write": true + }, + "43068": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43068", + "write": true + }, + "43069": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43069", + "write": true + }, + "43070": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43070", + "write": true + }, + "43071": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43071", + "write": true + }, + "43072": { + "title": "Start time", + "factor": 1, + "size": "u16", + "name": "start-time-43072", + "write": true + }, + "43074": { + "title": "Start time", + "factor": 1, + "size": "u16", + "name": "start-time-43074", + "write": true + }, + "43076": { + "title": "Stop time", + "factor": 1, + "size": "u16", + "name": "stop-time-43076", + "write": true + }, + "42668": { + "title": "Offset cooling (EME20)", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 0.0, + "default": -1.0, + "name": "offset-cooling-eme20-42668", + "write": true + }, + "42669": { + "title": "Offset heating (EME20)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 1.0, + "name": "offset-heating-eme20-42669", + "write": true + }, + "42670": { + "title": "Offset pool (EME20)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 10.0, + "name": "offset-pool-eme20-42670", + "write": true + }, + "42667": { + "title": "Cooling (EME20)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "cooling-eme20-42667", + "write": true + }, + "42676": { + "title": "AUX (EME20)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "aux-eme20-42676", + "write": true + }, + "40001": { + "title": "Temperature, Overload, pool", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 1.0, + "max": 50.0, + "default": 1.0, + "name": "temperature-overload-pool-40001", + "write": true + }, + "42108": { + "title": "EME20 API", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eme20-api-42108", + "write": true + }, + "42109": { + "title": "EME20 API Include own consumption", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eme20-api-include-own-consumption-42109", + "write": true + }, + "42110": { + "title": "EME20 API Available power", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 65535.0, + "default": 0.0, + "name": "eme20-api-available-power-42110", + "write": true + }, + "42112": { + "title": "External adjustment input, main unit (ECS1)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-main-unit-ecs1-42112", + "write": true + }, + "42113": { + "title": "External adjustment input (ECS2)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs2-42113", + "write": true + }, + "42114": { + "title": "External adjustment input (ECS3)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs3-42114", + "write": true + }, + "42115": { + "title": "External adjustment input (ECS4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs4-42115", + "write": true + }, + "42116": { + "title": "External adjustment input (ECS5)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs5-42116", + "write": true + }, + "42117": { + "title": "External adjustment input (ECS6)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs6-42117", + "write": true + }, + "42118": { + "title": "External adjustment input (ECS7)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs7-42118", + "write": true + }, + "42119": { + "title": "External adjustment input (ECS8)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs8-42119", + "write": true + }, + "42120": { + "title": "Zone 1 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-1-affected-by-ecs1-42120", + "write": true + }, + "42121": { + "title": "Zone 2 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-2-affected-by-ecs1-42121", + "write": true + }, + "42122": { + "title": "Zone 3 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-3-affected-by-ecs1-42122", + "write": true + }, + "42123": { + "title": "Zone 4 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-4-affected-by-ecs1-42123", + "write": true + }, + "42124": { + "title": "Zone 5 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-5-affected-by-ecs1-42124", + "write": true + }, + "42125": { + "title": "Zone 6 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-6-affected-by-ecs1-42125", + "write": true + }, + "42126": { + "title": "Zone 7 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-7-affected-by-ecs1-42126", + "write": true + }, + "42127": { + "title": "Zone 8 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-8-affected-by-ecs1-42127", + "write": true + }, + "42128": { + "title": "Zone 9 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-9-affected-by-ecs1-42128", + "write": true + }, + "42129": { + "title": "Zone 10 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-10-affected-by-ecs1-42129", + "write": true + }, + "42130": { + "title": "Zone 11 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-11-affected-by-ecs1-42130", + "write": true + }, + "42131": { + "title": "Zone 12 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-12-affected-by-ecs1-42131", + "write": true + }, + "42132": { + "title": "Zone 13 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-13-affected-by-ecs1-42132", + "write": true + }, + "42133": { + "title": "Zone 14 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-14-affected-by-ecs1-42133", + "write": true + }, + "42134": { + "title": "Zone 15 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-15-affected-by-ecs1-42134", + "write": true + }, + "42135": { + "title": "Zone 16 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-16-affected-by-ecs1-42135", + "write": true + }, + "42136": { + "title": "Zone 17 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-17-affected-by-ecs1-42136", + "write": true + }, + "42137": { + "title": "Zone 18 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-18-affected-by-ecs1-42137", + "write": true + }, + "42138": { + "title": "Zone 19 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-19-affected-by-ecs1-42138", + "write": true + }, + "42139": { + "title": "Zone 20 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-20-affected-by-ecs1-42139", + "write": true + }, + "42140": { + "title": "Zone 21 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-21-affected-by-ecs1-42140", + "write": true + }, + "42141": { + "title": "Zone 22 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-22-affected-by-ecs1-42141", + "write": true + }, + "42142": { + "title": "Zone 23 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-23-affected-by-ecs1-42142", + "write": true + }, + "42143": { + "title": "Zone 24 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-24-affected-by-ecs1-42143", + "write": true + }, + "42144": { + "title": "Zone 25 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-25-affected-by-ecs1-42144", + "write": true + }, + "42145": { + "title": "Zone 26 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-26-affected-by-ecs1-42145", + "write": true + }, + "42146": { + "title": "Zone 27 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-27-affected-by-ecs1-42146", + "write": true + }, + "42147": { + "title": "Zone 28 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-28-affected-by-ecs1-42147", + "write": true + }, + "42148": { + "title": "Zone 29 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-29-affected-by-ecs1-42148", + "write": true + }, + "42149": { + "title": "Zone 30 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-30-affected-by-ecs1-42149", + "write": true + }, + "42150": { + "title": "Zone 31 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-31-affected-by-ecs1-42150", + "write": true + }, + "42151": { + "title": "Zone 32 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-32-affected-by-ecs1-42151", + "write": true + }, + "42152": { + "title": "Zone 33 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-33-affected-by-ecs1-42152", + "write": true + }, + "42153": { + "title": "Zone 34 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-34-affected-by-ecs1-42153", + "write": true + }, + "42154": { + "title": "Zone 35 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-35-affected-by-ecs1-42154", + "write": true + }, + "42155": { + "title": "Zone 36 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-36-affected-by-ecs1-42155", + "write": true + }, + "42156": { + "title": "Zone 37 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-37-affected-by-ecs1-42156", + "write": true + }, + "42157": { + "title": "Zone 38 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-38-affected-by-ecs1-42157", + "write": true + }, + "42158": { + "title": "Zone 39 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-39-affected-by-ecs1-42158", + "write": true + }, + "42159": { + "title": "Zone 40 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-40-affected-by-ecs1-42159", + "write": true + }, + "42440": { + "title": "Input on ECS1 affects ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs1-42440", + "write": true + }, + "42441": { + "title": "Input on ECS1 affects ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs2-42441", + "write": true + }, + "42442": { + "title": "Input on ECS1 affects ECS3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs3-42442", + "write": true + }, + "42443": { + "title": "Input on ECS1 affects ECS4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs4-42443", + "write": true + }, + "42444": { + "title": "Input on ECS1 affects ECS5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs5-42444", + "write": true + }, + "42445": { + "title": "Input on ECS1 affects ECS6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs6-42445", + "write": true + }, + "42446": { + "title": "Input on ECS1 affects ECS7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs7-42446", + "write": true + }, + "42447": { + "title": "Input on ECS1 affects ECS8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs8-42447", + "write": true + }, + "42504": { + "title": "External setting for adjustment migrated", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-setting-for-adjustment-migrated-42504", + "write": true + }, + "32148": { + "title": "Version, inverter (EB101)", + "factor": 1, + "size": "u8", + "name": "version-inverter-eb101-32148" + }, + "42677": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42677", + "write": true + }, + "42678": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42678", + "write": true + }, + "42679": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42679", + "write": true + }, + "42680": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42680", + "write": true + }, + "42701": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42701", + "write": true + }, + "42702": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42702", + "write": true + }, + "42703": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42703", + "write": true + }, + "42704": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42704", + "write": true + }, + "42705": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42705", + "write": true + }, + "42706": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42706", + "write": true + }, + "42707": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42707", + "write": true + }, + "42708": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42708", + "write": true + }, + "42709": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42709", + "write": true + }, + "42710": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42710", + "write": true + }, + "42711": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42711", + "write": true + }, + "42712": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42712", + "write": true + }, + "42713": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42713", + "write": true + }, + "42714": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42714", + "write": true + }, + "42715": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42715", + "write": true + }, + "42716": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42716", + "write": true + }, + "42729": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42729", + "write": true + }, + "42730": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42730", + "write": true + }, + "42731": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42731", + "write": true + }, + "42732": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42732", + "write": true + }, + "42741": { + "title": "AUX from Modbus", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 61.0, + "default": 0.0, + "name": "aux-from-modbus-42741", + "write": true + }, + "42742": { + "title": "AUX from Modbus", + "factor": 1, + "size": "s16", + "name": "aux-from-modbus-42742", + "write": true + }, + "32159": { + "title": "Last defrost, heat pump 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 255.0, + "default": 255.0, + "name": "last-defrost-heat-pump-1-32159" + }, + "42821": { + "title": "ERS 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-2-42821", + "write": true + }, + "42822": { + "title": "ERS 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-3-42822", + "write": true + }, + "42823": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-4-42823", + "write": true + }, + "42824": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-4-42824", + "write": true + }, + "42825": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42825", + "write": true + }, + "42826": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42826", + "write": true + }, + "42827": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42827", + "write": true + }, + "42828": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42828", + "write": true + }, + "42858": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42858", + "write": true + }, + "42859": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42859", + "write": true + }, + "42860": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42860", + "write": true + }, + "42861": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42861", + "write": true + }, + "42829": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42829", + "write": true + }, + "42830": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42830", + "write": true + }, + "42831": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42831", + "write": true + }, + "42832": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42832", + "write": true + }, + "32169": { + "title": "Fan mode 5", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-5-32169" + }, + "32170": { + "title": "Fan mode 6", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-6-32170" + }, + "32171": { + "title": "Fan mode 7", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-7-32171" + }, + "32172": { + "title": "Fan mode 8", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-8-32172" + }, + "44205": { + "title": "Disable emergency restart GP1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "disable-emergency-restart-gp1-44205", + "write": true + }, + "45026": { + "title": "Disable emergency restart GP1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "disable-emergency-restart-gp1-45026", + "write": true + }, + "30001": { + "title": "Relay status", + "factor": 1, + "size": "u8", + "name": "relay-status-30001" + }, + "43029": { + "title": "Immersion heater power, emergency mode", + "factor": 100, + "unit": "kW", + "size": "s16", + "min": 0.0, + "max": 4500.0, + "default": 600.0, + "name": "immersion-heater-power-emergency-mode-43029", + "write": true + }, + "43987": { + "title": "Disable emergency restart GP1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "disable-emergency-restart-gp1-43987", + "write": true + }, + "32191": { + "title": "Return line (AZ2-BT69)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-az2-bt69-32191" + }, + "32192": { + "title": "Supply line (AZ2-BT68)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-az2-bt68-32192" + } +} diff --git a/nibe/heatpump.py b/nibe/heatpump.py index 05f2670..3d1264e 100644 --- a/nibe/heatpump.py +++ b/nibe/heatpump.py @@ -41,6 +41,8 @@ class Model(Enum): S320 = "s320_s325" S325 = "s320_s325" + S2125 = "s2125" + SMO20 = "smo20" SMO40 = "smo40" From 63066f6888c41bf9bad995ce7b3712360eeafbed Mon Sep 17 00:00:00 2001 From: Joakim Plate Date: Fri, 2 Dec 2022 22:36:38 +0100 Subject: [PATCH 2/4] Move series to model - Make series part of model enum - Avoid model enum aliases --- nibe/heatpump.py | 76 +++++++++++++++++++++++++----------------------- 1 file changed, 39 insertions(+), 37 deletions(-) diff --git a/nibe/heatpump.py b/nibe/heatpump.py index 3d1264e..bbe05bc 100644 --- a/nibe/heatpump.py +++ b/nibe/heatpump.py @@ -15,58 +15,67 @@ class Series(Enum): + CUSTOM = auto() F = auto() S = auto() class Model(Enum): - F1155 = "f1155_f1255" - F1255 = "f1155_f1255" + F1155 = "f1155_f1255", Series.F + F1255 = "f1155_f1255", Series.F - S1155 = "s1155_s1255" - S1255 = "s1155_s1255" + S1155 = "s1155_s1255", Series.S + S1255 = "s1155_s1255", Series.S - F1145 = "f1145_f1245" - F1245 = "f1145_f1245" + F1145 = "f1145_f1245", Series.F + F1245 = "f1145_f1245", Series.F - F1345 = "f1345" - F1355 = "f1355" + F1345 = "f1345", Series.F + F1355 = "f1355", Series.F - F730 = "f730" - F750 = "f750" + F730 = "f730", Series.F + F750 = "f750", Series.F - F370 = "f370_f470" - F470 = "f370_f470" + F370 = "f370_f470", Series.F + F470 = "f370_f470", Series.F - S320 = "s320_s325" - S325 = "s320_s325" + S320 = "s320_s325", Series.S + S325 = "s320_s325", Series.S - S2125 = "s2125" + S2125 = "s2125", Series.S - SMO20 = "smo20" - SMO40 = "smo40" + SMO20 = "smo20", Series.F + SMO40 = "smo40", Series.F - SMOS40 = "smos40" + SMOS40 = "smos40", Series.S - VVM225 = "vvm225_vvm320_vvm325" - VVM320 = "vvm225_vvm320_vvm325" - VVM325 = "vvm225_vvm320_vvm325" + VVM225 = "vvm225_vvm320_vvm325", Series.F + VVM320 = "vvm225_vvm320_vvm325", Series.F + VVM325 = "vvm225_vvm320_vvm325", Series.F - VVM310 = "vvm310_vvm500" - VVM500 = "vvm310_vvm500" + VVM310 = "vvm310_vvm500", Series.F + VVM500 = "vvm310_vvm500", Series.F - CUSTOM = "custom" + CUSTOM = "custom", Series.CUSTOM data_file: Union[str, bytes, PathLike[str], PathLike[bytes]] + series: Series + + def __new__(cls, data_file: str, series: Series): + value = len(cls.__members__) + 1 + obj = object.__new__(cls) + obj._value_ = value + obj.data_file = data_file + obj.series = series + return obj def get_coil_data(self): - if self.value == "custom": + if self == Model.CUSTOM: with open(self.data_file) as fh: return json.load(fh) else: - return json.loads( - files("nibe.data").joinpath(f"{self.value}.json").read_text() - ) + with files("nibe.data").joinpath(f"{self.data_file}.json").open("r") as fh: + return json.load(fh) @classmethod def keys(cls): @@ -116,15 +125,8 @@ def model(self, model: Model): @property def series(self) -> Series: - if self._model in ( - Model.S1155, - Model.S1255, - Model.S320, - Model.S325, - Model.SMOS40, - ): - return Series.S - return Series.F + assert self._model + return self._model.series @property def product_info(self) -> Union[ProductInfo, None]: From 74a2a9641c2714bdb65fc4b196457ada09caa8ab Mon Sep 17 00:00:00 2001 From: Joakim Plate Date: Fri, 2 Dec 2022 22:41:04 +0100 Subject: [PATCH 3/4] Bump to 1.5.0 --- nibe/__init__.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/nibe/__init__.py b/nibe/__init__.py index bf25615..5b60188 100644 --- a/nibe/__init__.py +++ b/nibe/__init__.py @@ -1 +1 @@ -__version__ = "1.4.1" +__version__ = "1.5.0" From 259c295d62dfbd222270eaa385dd812f2f558049 Mon Sep 17 00:00:00 2001 From: Joakim Plate Date: Fri, 2 Dec 2022 23:02:21 +0100 Subject: [PATCH 4/4] Expose event for product info --- nibe/connection/nibegw.py | 11 ++++++++--- 1 file changed, 8 insertions(+), 3 deletions(-) diff --git a/nibe/connection/nibegw.py b/nibe/connection/nibegw.py index b473b0d..04b1739 100644 --- a/nibe/connection/nibegw.py +++ b/nibe/connection/nibegw.py @@ -84,6 +84,7 @@ def __str__(self): class NibeGW(asyncio.DatagramProtocol, Connection, EventServer): CONNECTION_STATUS_EVENT = "connection_status" + PRODUCT_INFO_EVENT = "product_info" _futures: Dict[str, Future] _status: ConnectionStatus @@ -206,8 +207,13 @@ def datagram_received(self, data: bytes, addr): elif cmd == "RMU_DATA_MSG": self._on_rmu_data(msg.fields.value) elif cmd == "PRODUCT_INFO_MSG": + data = msg.fields.value.data + product_info = ProductInfo(data["model"], data["version"]) with suppress(InvalidStateError, CancelledError, KeyError): - self._futures["product_info"].set_result(msg.fields.value.data) + self._futures["product_info"].set_result(product_info) + self.notify_event_listeners( + self.PRODUCT_INFO_EVENT, product_info=product_info + ) elif not isinstance(cmd, EnumIntegerString): logger.debug(f"Unknown command {cmd}") except ChecksumError: @@ -227,8 +233,7 @@ async def read_product_info( ) -> ProductInfo: self._futures["product_info"] = asyncio.get_event_loop().create_future() try: - result = await asyncio.wait_for(self._futures["product_info"], timeout) - return ProductInfo(result["model"], result["version"]) + return await asyncio.wait_for(self._futures["product_info"], timeout) except asyncio.TimeoutError: raise ProductInfoReadTimeoutException("Timeout waiting for product message") finally: