From 6509a25982f5c054b9507609e0a94819b078241f Mon Sep 17 00:00:00 2001 From: Michal Hajek Date: Fri, 3 Jan 2025 12:38:01 +0100 Subject: [PATCH 1/2] Nibe S1156 --- nibe/data/s1156.csv | 2086 ++++++++ nibe/data/s1156.json | 10757 +++++++++++++++++++++++++++++++++++++++++ 2 files changed, 12843 insertions(+) create mode 100755 nibe/data/s1156.csv create mode 100644 nibe/data/s1156.json diff --git a/nibe/data/s1156.csv b/nibe/data/s1156.csv new file mode 100755 index 0000000..aa02585 --- /dev/null +++ b/nibe/data/s1156.csv @@ -0,0 +1,2086 @@ +Title Register type Register Division factor Unit Size of variable Min value Max value Default value +Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0 +Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0 +Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0 +Supply line (EP21-BT2) MODBUS_INPUT_REGISTER 4 10 °C 2 0 0 0 +Supply line (BT2) MODBUS_INPUT_REGISTER 5 10 °C 2 0 0 0 +Return line (BT3) MODBUS_INPUT_REGISTER 7 10 °C 2 0 0 0 +Hot water top (BT7) MODBUS_INPUT_REGISTER 8 10 °C 2 0 0 0 +Hot water charging (BT6) MODBUS_INPUT_REGISTER 9 10 °C 2 0 0 0 +Brine in (BT10) MODBUS_INPUT_REGISTER 10 10 °C 2 0 0 0 +Brine out (BT11) MODBUS_INPUT_REGISTER 11 10 °C 2 0 0 0 +Condenser (BT12) MODBUS_INPUT_REGISTER 12 10 °C 2 0 0 0 +Discharge (BT14) MODBUS_INPUT_REGISTER 13 10 °C 2 0 0 0 +Liquid line (BT15) MODBUS_INPUT_REGISTER 14 10 °C 2 0 0 0 +Suction gas (BT17) MODBUS_INPUT_REGISTER 16 10 °C 2 0 0 0 +Collector in (AZ10-BT26) MODBUS_INPUT_REGISTER 21 10 °C 2 0 0 0 +Collector out (AZ10-BT27) MODBUS_INPUT_REGISTER 22 10 °C 2 0 0 0 +Return line (EQ1-BT65) MODBUS_INPUT_REGISTER 31 10 °C 2 0 0 0 +Temperature limiter (EB100-FD1) MODBUS_INPUT_REGISTER 36 1 2 0 0 0 +Average temperature (BT1) MODBUS_INPUT_REGISTER 37 10 °C 2 0 0 0 +Boiler temperature (BT52) MODBUS_INPUT_REGISTER 38 10 °C 2 0 0 0 +External supply line (BT25) MODBUS_INPUT_REGISTER 39 10 °C 2 0 0 0 +Flow sensor (BF1) MODBUS_INPUT_REGISTER 40 10 l/m 2 0 0 0 +Electrical anode (EB100-FR1) MODBUS_INPUT_REGISTER 41 1 2 0 0 0 +Pool (CL12-BT51) MODBUS_INPUT_REGISTER 59 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 60 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 61 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 62 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 63 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 64 10 °C 2 0 0 0 +- MODBUS_INPUT_REGISTER 65 10 °C 2 0 0 0 +Collector in (AZ13-BT26) MODBUS_INPUT_REGISTER 66 10 °C 2 0 0 0 +Collector in (AZ12-BT26) MODBUS_INPUT_REGISTER 67 10 °C 2 0 0 0 +Collector in (AZ11-BT26) MODBUS_INPUT_REGISTER 68 10 °C 2 0 0 0 +Collector out (AZ13-BT27) MODBUS_INPUT_REGISTER 69 10 °C 2 0 0 0 +Collector out (AZ12-BT27) MODBUS_INPUT_REGISTER 70 10 °C 2 0 0 0 +Collector out (AZ11-BT27) MODBUS_INPUT_REGISTER 71 10 °C 2 0 0 0 +Low press (BP8) MODBUS_INPUT_REGISTER 2308 100 bar 2 0 0 0 +Return line (EP23-BT3) MODBUS_INPUT_REGISTER 75 10 °C 2 0 0 0 +Return line (EP22-BT3) MODBUS_INPUT_REGISTER 76 10 °C 2 0 0 0 +Return line (EP21-BT3) MODBUS_INPUT_REGISTER 77 10 °C 2 0 0 0 +Return line (EP15-BT3) MODBUS_INPUT_REGISTER 78 10 °C 2 0 0 0 +Oil temperature (BT29) MODBUS_INPUT_REGISTER 86 10 °C 2 0 0 0 +Outgoing hot water (BT70) MODBUS_INPUT_REGISTER 87 10 °C 2 0 0 0 +Collector (EQ1-BT57) MODBUS_INPUT_REGISTER 90 10 °C 2 0 0 0 +Heating dump (EQ1-BT75) MODBUS_INPUT_REGISTER 91 10 °C 2 0 0 0 +Supply line (EP47-BT2) MODBUS_INPUT_REGISTER 94 10 °C 2 0 0 0 +Supply line (EP46-BT2) MODBUS_INPUT_REGISTER 95 10 °C 2 0 0 0 +Supply line (EP45-BT2) MODBUS_INPUT_REGISTER 96 10 °C 2 0 0 0 +Supply line (EP44-BT2) MODBUS_INPUT_REGISTER 97 10 °C 2 0 0 0 +Return line (EP47-BT3) MODBUS_INPUT_REGISTER 98 10 °C 2 0 0 0 +Return line (EP46-BT3) MODBUS_INPUT_REGISTER 99 10 °C 2 0 0 0 +Return line (EP45-BT3) MODBUS_INPUT_REGISTER 100 10 °C 2 0 0 0 +Return line (EP44-BT3) MODBUS_INPUT_REGISTER 101 10 °C 2 0 0 0 +Brine in (EP10-BT26) MODBUS_INPUT_REGISTER 106 10 °C 2 0 0 0 +id:149 MODBUS_INPUT_REGISTER 108 10 °C 2 0 0 0 +Room average temp. clim. system 8 (BT50) MODBUS_INPUT_REGISTER 109 10 °C 2 0 0 0 +Room average temp. clim. system 7 (BT50) MODBUS_INPUT_REGISTER 110 10 °C 2 0 0 0 +Room average temp. clim. system 6 (BT50) MODBUS_INPUT_REGISTER 111 10 °C 2 0 0 0 +Room average temp. clim. system 5 (BT50) MODBUS_INPUT_REGISTER 112 10 °C 2 0 0 0 +Room average temp. clim. system 4 (BT50) MODBUS_INPUT_REGISTER 113 10 °C 2 0 0 0 +Room average temp. clim. system 3 (BT50) MODBUS_INPUT_REGISTER 114 10 °C 2 0 0 0 +Room average temp. clim. system 2 (BT50) MODBUS_INPUT_REGISTER 115 10 °C 2 0 0 0 +Room average temp. clim. system 1 (BT50) MODBUS_INPUT_REGISTER 116 10 °C 2 0 0 0 +External cooling supply temperature (BT25) MODBUS_INPUT_REGISTER 119 10 °C 2 0 0 0 +Oper. mode shunt climate system 8 MODBUS_INPUT_REGISTER 129 1 4 0 0 0 +Oper. mode shunt climate system 7 MODBUS_INPUT_REGISTER 130 1 4 0 0 0 +Oper. mode shunt climate system 6 MODBUS_INPUT_REGISTER 131 1 4 0 0 0 +Oper. mode shunt climate system 5 MODBUS_INPUT_REGISTER 132 1 4 0 0 0 +id:246 MODBUS_INPUT_REGISTER 133 1 4 0 0 0 +Relay status (ERS 1) MODBUS_INPUT_REGISTER 134 1 4 0 0 0 +Fan speed (AZ30-GQ2) MODBUS_INPUT_REGISTER 135 1 % 4 0 0 0 +Fan speed (AZ30-GQ3) MODBUS_INPUT_REGISTER 136 1 % 4 0 0 0 +Current hot water mode controlled by MODBUS_INPUT_REGISTER 137 1 1 0 0 0 +Inverter limit status MODBUS_INPUT_REGISTER 138 1 4 0 0 0 +Inverter fault reset MODBUS_HOLDING_REGISTER 2755 1 5 1 1 1 +Requested compressor frequency MODBUS_INPUT_REGISTER 140 1 Hz 5 0 0 0 +Max. compressor frequency, heating MODBUS_INPUT_REGISTER 141 100 Hz 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 +Inverter fault code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 +Inverter run command MODBUS_INPUT_REGISTER 144 1 5 0 0 0 +Inverter pic. version MODBUS_INPUT_REGISTER 145 1 5 0 0 0 +Inverter 8051 version MODBUS_INPUT_REGISTER 146 1 5 0 0 0 +Inverter wizard MODBUS_INPUT_REGISTER 147 1 5 0 0 0 +Inverter version (MCE) MODBUS_INPUT_REGISTER 148 1 5 0 0 0 +Inverter hw version MODBUS_INPUT_REGISTER 149 1 5 0 0 0 +Inverter hw type MODBUS_INPUT_REGISTER 150 1 5 0 0 0 +External adjustment climate system 8 MODBUS_INPUT_REGISTER 151 1 4 0 0 0 +External adjustment climate system 7 MODBUS_INPUT_REGISTER 152 1 4 0 0 0 +External adjustment climate system 6 MODBUS_INPUT_REGISTER 153 1 4 0 0 0 +External adjustment climate system 5 MODBUS_INPUT_REGISTER 154 1 4 0 0 0 +Climate system 8 MODBUS_INPUT_REGISTER 156 1 4 0 0 0 +Climate system 7 MODBUS_INPUT_REGISTER 157 1 4 0 0 0 +Climate system 6 MODBUS_INPUT_REGISTER 158 1 4 0 0 0 +Climate system 5 MODBUS_INPUT_REGISTER 159 1 4 0 0 0 +Extra cooling MODBUS_INPUT_REGISTER 160 1 4 0 0 0 +Hot water comfort return (BT82) MODBUS_INPUT_REGISTER 174 10 °C 2 0 0 0 +Hot water comfort heater (BT83) MODBUS_INPUT_REGISTER 175 10 °C 2 0 0 0 +Compressor, total time pool, heat pump 8 (EP15) MODBUS_INPUT_REGISTER 179 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 8 (EP15) MODBUS_INPUT_REGISTER 181 1 h 6 0 0 0 +Compressor, total time pool, heat pump 8 (EP14) MODBUS_INPUT_REGISTER 185 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 8 (EP14) MODBUS_INPUT_REGISTER 187 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 7 (EP15) MODBUS_INPUT_REGISTER 191 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 7 (EP15) MODBUS_INPUT_REGISTER 193 1 h 6 0 0 0 +Compressor, total time pool, heat pump 7 (EP14) MODBUS_INPUT_REGISTER 197 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 7 (EP14) MODBUS_INPUT_REGISTER 199 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 6 (EP15) MODBUS_INPUT_REGISTER 203 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 6 (EP15) MODBUS_INPUT_REGISTER 205 1 h 6 0 0 0 +Compressor, total time pool, heat pump 6 (EP14) MODBUS_INPUT_REGISTER 209 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 6 (EP14) MODBUS_INPUT_REGISTER 211 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 5 (EP15) MODBUS_INPUT_REGISTER 215 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 5 (EP15) MODBUS_INPUT_REGISTER 217 1 h 6 0 0 0 +Compressor, total time pool, heat pump 5 (EP14) MODBUS_INPUT_REGISTER 221 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 5 (EP14) MODBUS_INPUT_REGISTER 223 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 4 (EP15) MODBUS_INPUT_REGISTER 227 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 4 (EP15) MODBUS_INPUT_REGISTER 229 1 h 6 0 0 0 +Compressor, total time pool, heat pump 4 (EP14) MODBUS_INPUT_REGISTER 233 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 4 (EP14) MODBUS_INPUT_REGISTER 235 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 3 (EP15) MODBUS_INPUT_REGISTER 239 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 3 (EP15) MODBUS_INPUT_REGISTER 241 1 h 6 0 0 0 +Compressor, total time pool, heat pump 3 (EP14) MODBUS_INPUT_REGISTER 245 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 3 (EP14) MODBUS_INPUT_REGISTER 247 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 2 (EP15) MODBUS_INPUT_REGISTER 251 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 2 (EP15) MODBUS_INPUT_REGISTER 253 1 h 6 0 0 0 +Compressor, total time pool, heat pump 2 (EP14) MODBUS_INPUT_REGISTER 257 1 h 6 0 2147483647 0 +Compressor, total time pool 2, heat pump 2 (EP14) MODBUS_INPUT_REGISTER 259 1 h 6 0 2147483647 0 +Compressor, total time pool, heat pump 1 (EP15) MODBUS_INPUT_REGISTER 263 1 h 6 0 0 0 +Compressor, total time pool 2, heat pump 1 (EP15) MODBUS_INPUT_REGISTER 265 1 h 6 0 0 0 +id:600 MODBUS_INPUT_REGISTER 269 1 h 6 0 2147483647 0 +id:601 MODBUS_INPUT_REGISTER 271 1 h 6 0 2147483647 0 +Compressor, total time cooling, main unit (EP14) MODBUS_INPUT_REGISTER 279 1 h 6 0 2147483647 0 +Compressor, total time pool, main unit (EP14) MODBUS_INPUT_REGISTER 281 1 h 6 0 2147483647 0 +Compressor, total time pool 2, main unit (EP14) MODBUS_INPUT_REGISTER 283 1 h 6 0 2147483647 0 +Heat pump 8 requested compressor frequency MODBUS_INPUT_REGISTER 294 1 Hz 4 0 0 0 +Heat pump 7 requested compressor frequency MODBUS_INPUT_REGISTER 295 1 Hz 4 0 0 0 +Heat pump 6 requested compressor frequency MODBUS_INPUT_REGISTER 296 1 Hz 4 0 0 0 +Heat pump 5 requested compressor frequency MODBUS_INPUT_REGISTER 297 1 Hz 4 0 0 0 +Heat pump 4 requested compressor frequency MODBUS_INPUT_REGISTER 298 1 Hz 4 0 0 0 +Heat pump 3 requested compressor frequency MODBUS_INPUT_REGISTER 299 1 Hz 4 0 0 0 +Heat pump 2 requested compressor frequency MODBUS_INPUT_REGISTER 300 1 Hz 4 0 0 0 +Heat pump 1 requested compressor frequency MODBUS_INPUT_REGISTER 301 1 Hz 4 0 0 0 +Frost protection heat exchanger heat pump 8 MODBUS_INPUT_REGISTER 303 1 4 0 0 0 +Frost protection heat exchanger heat pump 7 MODBUS_INPUT_REGISTER 304 1 4 0 0 0 +Frost protection heat exchanger heat pump 6 MODBUS_INPUT_REGISTER 305 1 4 0 0 0 +Frost protection heat exchanger heat pump 5 MODBUS_INPUT_REGISTER 306 1 4 0 0 0 +Frost protection heat exchanger heat pump 4 MODBUS_INPUT_REGISTER 307 1 4 0 0 0 +Frost protection heat exchanger heat pump 3 MODBUS_INPUT_REGISTER 308 1 4 0 0 0 +Frost protection heat exchanger heat pump 2 MODBUS_INPUT_REGISTER 309 1 4 0 0 0 +Status (OPT) MODBUS_INPUT_REGISTER 311 1 4 0 0 0 +Version (OPT) MODBUS_INPUT_REGISTER 312 1 5 0 0 0 +OPT relay, modulation level MODBUS_INPUT_REGISTER 313 10 % 2 0 0 0 +OPT operating time MODBUS_INPUT_REGISTER 315 1 h 5 0 0 0 +Compressor restrictions MODBUS_INPUT_REGISTER 2021 1 6 0 0 0 +Available compressors heating MODBUS_INPUT_REGISTER 317 1 4 0 0 0 +Available compressors hot water MODBUS_INPUT_REGISTER 318 1 4 0 0 0 +Available compressors pool 1 MODBUS_INPUT_REGISTER 319 1 4 0 0 0 +Available compressors pool 2 MODBUS_INPUT_REGISTER 320 1 4 0 0 0 +Available compressors cooling MODBUS_INPUT_REGISTER 321 1 4 0 0 0 +Available compressors external control MODBUS_INPUT_REGISTER 322 1 4 0 0 0 +Humidity (BM1) MODBUS_INPUT_REGISTER 323 10 % 2 0 0 0 +Temperature (BM1) MODBUS_INPUT_REGISTER 324 10 °C 2 0 0 0 +Pressure (BM1) MODBUS_INPUT_REGISTER 325 10 kPa 2 0 0 0 +Dew point (BM1) MODBUS_INPUT_REGISTER 326 10 °C 2 0 0 0 +Supply temperature (BT64) MODBUS_INPUT_REGISTER 337 10 °C 2 0 0 0 +Heat pump functionality 2 MODBUS_INPUT_REGISTER 338 1 6 0 0 0 +Status (EQ1) MODBUS_INPUT_REGISTER 340 1 4 0 0 0 +Status, heating dump shunt (EQ1) MODBUS_INPUT_REGISTER 341 1 4 0 0 0 +Degree minutes MODBUS_HOLDING_REGISTER 11 10 DM 3 -30000 30000 0 +Blocking (ERS 1) MODBUS_INPUT_REGISTER 358 1 4 0 0 0 +AZ30-EB17 MODBUS_INPUT_REGISTER 359 1 4 0 0 0 +id:803 MODBUS_INPUT_REGISTER 377 1 6 0 2147483647 0 +id:804 MODBUS_INPUT_REGISTER 379 1 6 0 0 0 +id:805 MODBUS_INPUT_REGISTER 381 1 6 0 2147483647 0 +id:806 MODBUS_INPUT_REGISTER 383 1 6 0 0 0 +Seconds of blank time left, charge pump 8 MODBUS_INPUT_REGISTER 385 1 4 0 0 0 +Seconds of blank time left, charge pump 7 MODBUS_INPUT_REGISTER 386 1 4 0 0 0 +Seconds of blank time left, charge pump 6 MODBUS_INPUT_REGISTER 387 1 4 0 0 0 +Seconds of blank time left, charge pump 5 MODBUS_INPUT_REGISTER 388 1 4 0 0 0 +Seconds of blank time left, charge pump 4 MODBUS_INPUT_REGISTER 389 1 4 0 0 0 +Seconds of blank time left, charge pump 3 MODBUS_INPUT_REGISTER 390 1 4 0 0 0 +Seconds of blank time left, charge pump 2 MODBUS_INPUT_REGISTER 391 1 4 0 0 0 +Seconds of blank time left, charge pump 1 MODBUS_INPUT_REGISTER 392 1 4 0 0 0 +Inverter min speed MODBUS_INPUT_REGISTER 394 1 5 0 0 0 +Inverter max speed MODBUS_INPUT_REGISTER 395 1 5 0 0 0 +Max fan speed (EB101) MODBUS_INPUT_REGISTER 402 1 rpm 5 0 0 0 +Min fan speed (EB101) MODBUS_INPUT_REGISTER 403 1 rpm 5 0 0 0 +Generated power heating (EB101) MODBUS_INPUT_REGISTER 406 10 kW 5 0 0 0 +Time to defrosting (EB101) MODBUS_INPUT_REGISTER 407 1 min 5 0 0 0 +Defrosting index (EB101) MODBUS_INPUT_REGISTER 408 1 5 0 0 0 +Superheat reference EEV (EB101) MODBUS_INPUT_REGISTER 409 10 °C 2 0 0 0 +Superheat EEV (EB101) MODBUS_INPUT_REGISTER 410 10 °C 2 0 0 0 +EEV-ssh-error (EB101) MODBUS_INPUT_REGISTER 411 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB101) MODBUS_INPUT_REGISTER 412 10 °C 2 0 0 0 +Set point value EEV (EB101) MODBUS_INPUT_REGISTER 413 10 °C 2 0 0 0 +EEV PV (EB101) MODBUS_INPUT_REGISTER 414 10 °C 2 0 0 0 +EEV-te-error average open (EB101) MODBUS_INPUT_REGISTER 415 10 °C 2 0 0 0 +Degree of opening EEV (EB101) MODBUS_INPUT_REGISTER 416 1 5 0 0 0 +Superheat reference EVI (EB101) MODBUS_INPUT_REGISTER 417 10 °C 2 0 0 0 +Superheat EVI (EB101) MODBUS_INPUT_REGISTER 418 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB101) MODBUS_INPUT_REGISTER 419 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB101) MODBUS_INPUT_REGISTER 420 10 °C 2 0 0 0 +Set point value EVI (EB101) MODBUS_INPUT_REGISTER 421 10 °C 2 0 0 0 +EVI PV (EB101) MODBUS_INPUT_REGISTER 422 10 °C 2 0 0 0 +EEV-te-error average open in (EVI)(EB101) MODBUS_INPUT_REGISTER 423 10 °C 2 0 0 0 +Degree of opening EVI (EB101) MODBUS_INPUT_REGISTER 424 1 5 0 0 0 +id:859 MODBUS_INPUT_REGISTER 426 10 %RH 2 0 0 0 +id:861 MODBUS_INPUT_REGISTER 427 1 6 0 0 0 +id:862 MODBUS_INPUT_REGISTER 429 1 5 0 0 0 +Low press (EB108 BP8 dew) MODBUS_INPUT_REGISTER 438 10 °C 2 0 0 0 +Hi press (EB108 BP9 dew) MODBUS_INPUT_REGISTER 439 10 °C 2 0 0 0 +Pressure sensor, injection (EB108-BP11) MODBUS_INPUT_REGISTER 441 10 2 0 0 0 +EVI pressure (EB108-EP14-BP11 dew) MODBUS_INPUT_REGISTER 442 10 °C 2 0 0 0 +Fan status (EB108-EP14) MODBUS_INPUT_REGISTER 444 1 4 0 0 0 +Fan rpm (EB108-EP14) MODBUS_INPUT_REGISTER 445 1 rpm 5 0 0 0 +Low press (EB107 BP8 dew) MODBUS_INPUT_REGISTER 454 10 °C 2 0 0 0 +Hi press (EB107 BP9 dew) MODBUS_INPUT_REGISTER 455 10 °C 2 0 0 0 +Pressure sensor, injection (EB107-BP11) MODBUS_INPUT_REGISTER 457 10 2 0 0 0 +EVI pressure (EB107-EP14-BP11 dew) MODBUS_INPUT_REGISTER 458 10 °C 2 0 0 0 +Fan status (EB107-EP14) MODBUS_INPUT_REGISTER 460 1 4 0 0 0 +Fan rpm (EB107-EP14) MODBUS_INPUT_REGISTER 461 1 rpm 5 0 0 0 +Low press (EB106 BP8 dew) MODBUS_INPUT_REGISTER 470 10 °C 2 0 0 0 +Hi press (EB106 BP9 dew) MODBUS_INPUT_REGISTER 471 10 °C 2 0 0 0 +Pressure sensor, injection (EB106-BP11) MODBUS_INPUT_REGISTER 473 10 2 0 0 0 +EVI pressure (EB106-EP14-BP11 dew) MODBUS_INPUT_REGISTER 474 10 °C 2 0 0 0 +Fan status (EB106-EP14) MODBUS_INPUT_REGISTER 476 1 4 0 0 0 +Fan rpm (EB106-EP14) MODBUS_INPUT_REGISTER 477 1 rpm 5 0 0 0 +Low press (EB105 BP8 dew) MODBUS_INPUT_REGISTER 486 10 °C 2 0 0 0 +Hi press (EB105 BP9 dew) MODBUS_INPUT_REGISTER 487 10 °C 2 0 0 0 +Pressure sensor, injection (EB105-BP11) MODBUS_INPUT_REGISTER 489 10 2 0 0 0 +EVI pressure (EB105-EP14-BP11 dew) MODBUS_INPUT_REGISTER 490 10 °C 2 0 0 0 +Fan status (EB105-EP14) MODBUS_INPUT_REGISTER 492 1 4 0 0 0 +Fan rpm (EB105-EP14) MODBUS_INPUT_REGISTER 493 1 rpm 5 0 0 0 +Low press (EB104 BP8 dew) MODBUS_INPUT_REGISTER 502 10 °C 2 0 0 0 +Hi press (EB104 BP9 dew) MODBUS_INPUT_REGISTER 503 10 °C 2 0 0 0 +Pressure sensor, injection (EB104-BP11) MODBUS_INPUT_REGISTER 505 10 2 0 0 0 +EVI pressure (EB104-EP14-BP11 dew) MODBUS_INPUT_REGISTER 506 10 °C 2 0 0 0 +Fan status (EB104-EP14) MODBUS_INPUT_REGISTER 508 1 4 0 0 0 +Fan rpm (EB104-EP14) MODBUS_INPUT_REGISTER 509 1 rpm 5 0 0 0 +Low press (EB103 BP8 dew) MODBUS_INPUT_REGISTER 518 10 °C 2 0 0 0 +Hi press (EB103 BP9 dew) MODBUS_INPUT_REGISTER 519 10 °C 2 0 0 0 +Pressure sensor, injection (EB103-BP11) MODBUS_INPUT_REGISTER 521 10 2 0 0 0 +EVI pressure (EB103-EP14-BP11 dew) MODBUS_INPUT_REGISTER 522 10 °C 2 0 0 0 +Fan status (EB103-EP14) MODBUS_INPUT_REGISTER 524 1 4 0 0 0 +Fan rpm (EB103-EP14) MODBUS_INPUT_REGISTER 525 1 rpm 5 0 0 0 +Low press (EB102 BP8 dew) MODBUS_INPUT_REGISTER 534 10 °C 2 0 0 0 +Hi press (EB102 BP9 dew) MODBUS_INPUT_REGISTER 535 10 °C 2 0 0 0 +Pressure sensor, injection (EB102-EP14-BP11) MODBUS_INPUT_REGISTER 537 10 2 0 0 0 +EVI pressure (EB102-EP14-BP11 dew) MODBUS_INPUT_REGISTER 538 10 °C 2 0 0 0 +Fan status (EB102-EP14) MODBUS_INPUT_REGISTER 540 1 4 0 0 0 +Fan rpm (EB102-EP14) MODBUS_INPUT_REGISTER 541 1 rpm 5 0 0 0 +Low press (EB101 BP8 dew) MODBUS_INPUT_REGISTER 550 10 °C 2 0 0 0 +Hi press (EB101 BP9 dew) MODBUS_INPUT_REGISTER 551 10 °C 2 0 0 0 +Pressure sensor, injection (EB101-BP11) MODBUS_INPUT_REGISTER 553 10 2 0 0 0 +EVI pressure (EB101-EP14-BP11 dew) MODBUS_INPUT_REGISTER 554 10 °C 2 0 0 0 +Fan status (EB101-EP14) MODBUS_INPUT_REGISTER 556 1 4 0 0 0 +Fan rpm (EB101-EP14) MODBUS_INPUT_REGISTER 557 1 rpm 5 0 0 0 +Operating mode PV panels MODBUS_INPUT_REGISTER 579 1 4 0 0 0 +EME lux mode without EME MODBUS_INPUT_REGISTER 581 1 4 0 0 0 +Timer (EME) MODBUS_INPUT_REGISTER 582 60 min 5 0 0 0 +Fan mode 4 MODBUS_INPUT_REGISTER 590 1 % 4 0 0 0 +Fan mode 3 MODBUS_INPUT_REGISTER 591 1 % 4 0 0 0 +Fan mode 2 MODBUS_INPUT_REGISTER 592 1 % 4 0 0 0 +Is the compressor accessible MODBUS_INPUT_REGISTER 593 1 4 0 0 0 +Prio, hot water (OPT) MODBUS_INPUT_REGISTER 604 1 4 0 0 0 +Permit (undefined) MODBUS_INPUT_REGISTER 683 1 4 0 0 0 +Permit (undefined) MODBUS_INPUT_REGISTER 684 1 4 0 0 0 +Permit (undefined) MODBUS_INPUT_REGISTER 685 1 4 0 0 0 +Permit (OPT 10) additional heat MODBUS_INPUT_REGISTER 686 1 4 0 0 0 +Permit ext. imm. heater step MODBUS_INPUT_REGISTER 687 1 4 0 0 0 +Permit int. imm. heater step MODBUS_INPUT_REGISTER 688 1 4 0 0 0 +Permit shunted additional heat MODBUS_INPUT_REGISTER 689 1 4 0 0 0 +Permit prioritised additional heat MODBUS_INPUT_REGISTER 690 1 4 0 0 0 +Permit (EB108-EP15) MODBUS_INPUT_REGISTER 691 1 4 0 0 0 +Permit (EB107-EP15) MODBUS_INPUT_REGISTER 692 1 4 0 0 0 +Permit (EB106-EP15) MODBUS_INPUT_REGISTER 693 1 4 0 0 0 +Permit (EB105-EP15) MODBUS_INPUT_REGISTER 694 1 4 0 0 0 +Permit (EB104-EP15) MODBUS_INPUT_REGISTER 695 1 4 0 0 0 +Permit (EB103-EP15) MODBUS_INPUT_REGISTER 696 1 4 0 0 0 +Permit (EB102-EP15) MODBUS_INPUT_REGISTER 697 1 4 0 0 0 +Permit (EB101-EP15) MODBUS_INPUT_REGISTER 698 1 4 0 0 0 +Permit (EB100-EP15) MODBUS_INPUT_REGISTER 699 1 4 0 0 0 +Permit (EB108-EP14) MODBUS_INPUT_REGISTER 700 1 4 0 0 0 +Permit (EB107-EP14) MODBUS_INPUT_REGISTER 701 1 4 0 0 0 +Permit (EB106-EP14) MODBUS_INPUT_REGISTER 702 1 4 0 0 0 +Permit (EB105-EP14) MODBUS_INPUT_REGISTER 703 1 4 0 0 0 +Permit (EB104-EP14) MODBUS_INPUT_REGISTER 704 1 4 0 0 0 +Permit (EB103-EP14) MODBUS_INPUT_REGISTER 705 1 4 0 0 0 +Permit (EB102-EP14) MODBUS_INPUT_REGISTER 706 1 4 0 0 0 +Permit (EB101-EP14) MODBUS_INPUT_REGISTER 707 1 4 0 0 0 +Permit (EB100-EP14) MODBUS_INPUT_REGISTER 708 1 4 0 0 0 +Smart energy source, priority 7, start DM MODBUS_INPUT_REGISTER 709 1 3 0 0 0 +Smart energy source, priority 6, start DM MODBUS_INPUT_REGISTER 711 1 3 0 0 0 +Smart energy source, priority 5, start DM MODBUS_INPUT_REGISTER 713 1 3 0 0 0 +Smart energy source, priority 4, start DM MODBUS_INPUT_REGISTER 715 1 3 0 0 0 +Smart energy source, priority 3, start DM MODBUS_INPUT_REGISTER 717 1 3 0 0 0 +Smart energy source, priority 2, start DM MODBUS_INPUT_REGISTER 719 1 3 0 0 0 +Smart energy source, priority 1, start DM MODBUS_INPUT_REGISTER 721 1 3 0 0 0 +Smart energy source, priority 7, stop DM MODBUS_INPUT_REGISTER 723 1 3 0 0 0 +Smart energy source, priority 6, stop DM MODBUS_INPUT_REGISTER 725 1 3 0 0 0 +Smart energy source, priority 5, stop DM MODBUS_INPUT_REGISTER 727 1 3 0 0 0 +Smart energy source, priority 4, stop DM MODBUS_INPUT_REGISTER 729 1 3 0 0 0 +Smart energy source, priority 3, stop DM MODBUS_INPUT_REGISTER 731 1 3 0 0 0 +Smart energy source, priority 2, stop DM MODBUS_INPUT_REGISTER 733 1 3 0 0 0 +Smart energy source, priority 1, stop DM MODBUS_INPUT_REGISTER 735 1 3 0 0 0 +Smart energy source, DM minimum value MODBUS_INPUT_REGISTER 737 1 3 0 0 0 +External guide status MODBUS_INPUT_REGISTER 745 1 4 0 0 0 +Test guide value MODBUS_INPUT_REGISTER 746 1 5 0 0 0 +Temp. lux forces start of hot water demand MODBUS_INPUT_REGISTER 747 1 4 0 0 0 +Wood boiler activated MODBUS_INPUT_REGISTER 759 1 4 0 0 0 +Max fan speed (EB108-F21x0) MODBUS_INPUT_REGISTER 762 1 rpm 5 0 0 0 +Min fan speed (EB108) MODBUS_INPUT_REGISTER 763 1 rpm 5 0 0 0 +Generated power heating (EB108) MODBUS_INPUT_REGISTER 766 10 kW 5 0 0 0 +Time to defrosting (EB108) MODBUS_INPUT_REGISTER 767 1 min 5 0 0 0 +Defrosting index (EB108) MODBUS_INPUT_REGISTER 768 1 5 0 0 0 +Superheat reference EEV (EB108) MODBUS_INPUT_REGISTER 769 10 °C 2 0 0 0 +Superheat EEV (EB108) MODBUS_INPUT_REGISTER 770 10 °C 2 0 0 0 +EEV-ssh-error (EB108) MODBUS_INPUT_REGISTER 771 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB108) MODBUS_INPUT_REGISTER 772 10 °C 2 0 0 0 +Set point value EEV (EB108) MODBUS_INPUT_REGISTER 773 10 °C 2 0 0 0 +EEV PV (EB108) MODBUS_INPUT_REGISTER 774 10 °C 2 0 0 0 +EEV-te-error average open (EB108) MODBUS_INPUT_REGISTER 775 10 °C 2 0 0 0 +Degree of opening EEV (EB108) MODBUS_INPUT_REGISTER 776 1 5 0 0 0 +Superheat reference EVI (EB108) MODBUS_INPUT_REGISTER 777 10 °C 2 0 0 0 +Superheat EVI (EB108) MODBUS_INPUT_REGISTER 778 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB108) MODBUS_INPUT_REGISTER 779 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB108) MODBUS_INPUT_REGISTER 780 10 °C 2 0 0 0 +Set point value EVI (EB108) MODBUS_INPUT_REGISTER 781 10 °C 2 0 0 0 +EVI PV (EB108) MODBUS_INPUT_REGISTER 782 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB108) MODBUS_INPUT_REGISTER 783 10 °C 2 0 0 0 +Degree of opening EVI (EB108) MODBUS_INPUT_REGISTER 784 1 5 0 0 0 +Max fan speed (EB107) MODBUS_INPUT_REGISTER 787 1 rpm 5 0 0 0 +Min fan speed (EB107) MODBUS_INPUT_REGISTER 788 1 rpm 5 0 0 0 +Generated power heating (EB107) MODBUS_INPUT_REGISTER 791 10 kW 5 0 0 0 +Defrosting index (EB107) MODBUS_INPUT_REGISTER 793 1 5 0 0 0 +Superheat reference EEV (EB107) MODBUS_INPUT_REGISTER 794 10 °C 2 0 0 0 +Superheat EEV (EB107) MODBUS_INPUT_REGISTER 795 10 °C 2 0 0 0 +EEV-ssh-error (EB107) MODBUS_INPUT_REGISTER 796 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB107) MODBUS_INPUT_REGISTER 797 10 °C 2 0 0 0 +Set point value EEV (EB107) MODBUS_INPUT_REGISTER 798 10 °C 2 0 0 0 +EEV PV (EB107) MODBUS_INPUT_REGISTER 799 10 °C 2 0 0 0 +EEV-te-error average open (EB107) MODBUS_INPUT_REGISTER 800 10 °C 2 0 0 0 +Degree of opening EEV (EB107) MODBUS_INPUT_REGISTER 801 1 5 0 0 0 +Superheat reference EVI (EB107) MODBUS_INPUT_REGISTER 802 10 °C 2 0 0 0 +Superheat EVI (EB107) MODBUS_INPUT_REGISTER 803 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB107) MODBUS_INPUT_REGISTER 804 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB107) MODBUS_INPUT_REGISTER 805 10 °C 2 0 0 0 +Set point value EVI (EB107) MODBUS_INPUT_REGISTER 806 10 °C 2 0 0 0 +EVI PV (EB107) MODBUS_INPUT_REGISTER 807 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB107) MODBUS_INPUT_REGISTER 808 10 °C 2 0 0 0 +Degree of opening EVI (EB107) MODBUS_INPUT_REGISTER 809 1 5 0 0 0 +Max fan speed (EB106) MODBUS_INPUT_REGISTER 812 1 rpm 5 0 0 0 +id:1309 MODBUS_INPUT_REGISTER 813 1 rpm 5 0 0 0 +Generated power heating (EB106) MODBUS_INPUT_REGISTER 816 10 kW 5 0 0 0 +Defrosting index (EB106) MODBUS_INPUT_REGISTER 818 1 5 0 0 0 +Superheat reference EEV (EB106) MODBUS_INPUT_REGISTER 819 10 °C 2 0 0 0 +Superheat EEV (EB106) MODBUS_INPUT_REGISTER 820 10 °C 2 0 0 0 +EEV-ssh-error (EB106) MODBUS_INPUT_REGISTER 821 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB106) MODBUS_INPUT_REGISTER 822 10 °C 2 0 0 0 +Set point value EEV (EB106) MODBUS_INPUT_REGISTER 823 10 °C 2 0 0 0 +EEV PV (EB106) MODBUS_INPUT_REGISTER 824 10 °C 2 0 0 0 +EEV-te-error average open (EB106) MODBUS_INPUT_REGISTER 825 10 °C 2 0 0 0 +Degree of opening EEV (EB106) MODBUS_INPUT_REGISTER 826 1 5 0 0 0 +Superheat reference EVI (EB106) MODBUS_INPUT_REGISTER 827 10 °C 2 0 0 0 +Superheat EVI (EB106) MODBUS_INPUT_REGISTER 828 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB106) MODBUS_INPUT_REGISTER 829 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB106) MODBUS_INPUT_REGISTER 830 10 °C 2 0 0 0 +Set point value EVI (EB106) MODBUS_INPUT_REGISTER 831 10 °C 2 0 0 0 +EVI PV (EB106) MODBUS_INPUT_REGISTER 832 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB106) MODBUS_INPUT_REGISTER 833 10 °C 2 0 0 0 +Degree of opening EVI (EB106) MODBUS_INPUT_REGISTER 834 1 5 0 0 0 +Max fan speed (EB105) MODBUS_INPUT_REGISTER 837 1 rpm 5 0 0 0 +Min fan speed (EB105) MODBUS_INPUT_REGISTER 838 1 rpm 5 0 0 0 +Generated power heating (EB105) MODBUS_INPUT_REGISTER 841 10 kW 5 0 0 0 +Defrosting index (EB105) MODBUS_INPUT_REGISTER 843 1 5 0 0 0 +Superheat reference EEV (EB105) MODBUS_INPUT_REGISTER 844 10 °C 2 0 0 0 +Superheat EEV (EB105) MODBUS_INPUT_REGISTER 845 10 °C 2 0 0 0 +EEV-ssh-error (EB105) MODBUS_INPUT_REGISTER 846 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB105) MODBUS_INPUT_REGISTER 847 10 °C 2 0 0 0 +Set point value EEV (EB105) MODBUS_INPUT_REGISTER 848 10 °C 2 0 0 0 +EEV PV (EB105) MODBUS_INPUT_REGISTER 849 10 °C 2 0 0 0 +EEV-te-error average open (EB105) MODBUS_INPUT_REGISTER 850 10 °C 2 0 0 0 +Degree of opening EEV (EB105) MODBUS_INPUT_REGISTER 851 1 5 0 0 0 +Superheat reference EVI (EB105) MODBUS_INPUT_REGISTER 852 10 °C 2 0 0 0 +Superheat EVI (EB105) MODBUS_INPUT_REGISTER 853 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB105) MODBUS_INPUT_REGISTER 854 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB105) MODBUS_INPUT_REGISTER 855 10 °C 2 0 0 0 +Set point value EVI (EB105) MODBUS_INPUT_REGISTER 856 10 °C 2 0 0 0 +EVI PV (EB105) MODBUS_INPUT_REGISTER 857 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB105) MODBUS_INPUT_REGISTER 858 10 °C 2 0 0 0 +Degree of opening EVI (EB105) MODBUS_INPUT_REGISTER 859 1 5 0 0 0 +Max fan speed (EB104) MODBUS_INPUT_REGISTER 862 1 rpm 5 0 0 0 +Min fan speed (EB104) MODBUS_INPUT_REGISTER 863 1 rpm 5 0 0 0 +Generated power heating (EB104) MODBUS_INPUT_REGISTER 866 10 kW 5 0 0 0 +Defrosting index (EB104) MODBUS_INPUT_REGISTER 868 1 5 0 0 0 +Superheat reference EEV (EB104) MODBUS_INPUT_REGISTER 869 10 °C 2 0 0 0 +Superheat EEV (EB104) MODBUS_INPUT_REGISTER 870 10 °C 2 0 0 0 +EEV-ssh-error (EB104) MODBUS_INPUT_REGISTER 871 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB104) MODBUS_INPUT_REGISTER 872 10 °C 2 0 0 0 +Set point value EEV (EB104) MODBUS_INPUT_REGISTER 873 10 °C 2 0 0 0 +EEV PV (EB104) MODBUS_INPUT_REGISTER 874 10 °C 2 0 0 0 +EEV-te-error average open (EB104) MODBUS_INPUT_REGISTER 875 10 °C 2 0 0 0 +Degree of opening EEV (EB104) MODBUS_INPUT_REGISTER 876 1 5 0 0 0 +Superheat reference EVI (EB104) MODBUS_INPUT_REGISTER 877 10 °C 2 0 0 0 +Superheat EVI (EB104) MODBUS_INPUT_REGISTER 878 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB104) MODBUS_INPUT_REGISTER 879 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB104) MODBUS_INPUT_REGISTER 880 10 °C 2 0 0 0 +Set point value EVI (EB104) MODBUS_INPUT_REGISTER 881 10 °C 2 0 0 0 +EVI PV (EB104) MODBUS_INPUT_REGISTER 882 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB104) MODBUS_INPUT_REGISTER 883 10 °C 2 0 0 0 +Degree of opening EVI (EB104) MODBUS_INPUT_REGISTER 884 1 5 0 0 0 +Max fan speed (EB103) MODBUS_INPUT_REGISTER 887 1 rpm 5 0 0 0 +Min fan speed (EB103) MODBUS_INPUT_REGISTER 888 1 rpm 5 0 0 0 +Generated power heating (EB103) MODBUS_INPUT_REGISTER 891 10 kW 5 0 0 0 +Defrosting index (EB103) MODBUS_INPUT_REGISTER 893 1 5 0 0 0 +Superheat reference EEV (EB103) MODBUS_INPUT_REGISTER 894 10 °C 2 0 0 0 +Superheat EEV (EB103) MODBUS_INPUT_REGISTER 895 10 °C 2 0 0 0 +EEV-ssh-error (EB103) MODBUS_INPUT_REGISTER 896 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB103) MODBUS_INPUT_REGISTER 897 10 °C 2 0 0 0 +Set point value EEV (EB103) MODBUS_INPUT_REGISTER 898 10 °C 2 0 0 0 +EEV PV (EB103) MODBUS_INPUT_REGISTER 899 10 °C 2 0 0 0 +EEV-te-error average open (EB103) MODBUS_INPUT_REGISTER 900 10 °C 2 0 0 0 +Degree of opening EEV (EB103) MODBUS_INPUT_REGISTER 901 1 5 0 0 0 +Superheat reference EVI (EB103) MODBUS_INPUT_REGISTER 902 10 °C 2 0 0 0 +Superheat EVI (EB103) MODBUS_INPUT_REGISTER 903 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB103) MODBUS_INPUT_REGISTER 904 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB103) MODBUS_INPUT_REGISTER 905 10 °C 2 0 0 0 +Set point value EVI (EB103) MODBUS_INPUT_REGISTER 906 10 °C 2 0 0 0 +EVI PV (EB103) MODBUS_INPUT_REGISTER 907 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB103) MODBUS_INPUT_REGISTER 908 10 °C 2 0 0 0 +Degree of opening EVI (EB103) MODBUS_INPUT_REGISTER 909 1 5 0 0 0 +Fan speed (EB102) MODBUS_INPUT_REGISTER 911 1 rpm 5 0 0 0 +Max fan speed (EB102) MODBUS_INPUT_REGISTER 912 1 rpm 5 0 0 0 +Min fan speed (EB102) MODBUS_INPUT_REGISTER 913 1 rpm 5 0 0 0 +Generated power heating (EB102 MODBUS_INPUT_REGISTER 916 10 kW 5 0 0 0 +Defrosting index (EB102) MODBUS_INPUT_REGISTER 918 1 5 0 0 0 +Superheat reference EEV (EB102) MODBUS_INPUT_REGISTER 919 10 °C 2 0 0 0 +Superheat EEV (EB102) MODBUS_INPUT_REGISTER 920 10 °C 2 0 0 0 +EEV-ssh-error (EB102) MODBUS_INPUT_REGISTER 921 10 °C 2 0 0 0 +Superheat temp. reference EEV (EB101) MODBUS_INPUT_REGISTER 922 10 °C 2 0 0 0 +Set point value EEV (EB102) MODBUS_INPUT_REGISTER 923 10 °C 2 0 0 0 +EEV PV (EB102) MODBUS_INPUT_REGISTER 924 10 °C 2 0 0 0 +EEV-te-error average open (EB102) MODBUS_INPUT_REGISTER 925 10 °C 2 0 0 0 +Degree of opening EEV (EB102) MODBUS_INPUT_REGISTER 926 1 5 0 0 0 +Superheat reference EVI (EB102) MODBUS_INPUT_REGISTER 927 10 °C 2 0 0 0 +Superheat EVI (EB102) MODBUS_INPUT_REGISTER 928 10 °C 2 0 0 0 +EEV-ssh-error (EVI)(EB102) MODBUS_INPUT_REGISTER 929 10 °C 2 0 0 0 +Superheat temp. reference EVI (EB102) MODBUS_INPUT_REGISTER 930 10 °C 2 0 0 0 +Set point value EVI (EB102) MODBUS_INPUT_REGISTER 931 10 °C 2 0 0 0 +EVI PV (EB102) MODBUS_INPUT_REGISTER 932 10 °C 2 0 0 0 +EEV-te-error average open (EVI)(EB102) MODBUS_INPUT_REGISTER 933 10 °C 2 0 0 0 +Degree of opening EVI (EB102) MODBUS_INPUT_REGISTER 934 1 5 0 0 0 +Wind speed, weather forecast MODBUS_INPUT_REGISTER 960 10 5 0 0 0 +Humidity, weather forecast MODBUS_INPUT_REGISTER 961 10 % 5 0 0 0 +Temperature, weather forecast MODBUS_INPUT_REGISTER 962 10 °C 2 0 0 0 +Temperature, weather data (forecast) MODBUS_INPUT_REGISTER 963 10 °C 2 0 0 0 +Limit DM MODBUS_HOLDING_REGISTER 18 10 DM 2 -30000 30000 0 +Calculated supply climate system 2 MODBUS_INPUT_REGISTER 1016 10 °C 2 0 0 0 +Calculated supply climate system 1 MODBUS_INPUT_REGISTER 1017 10 °C 2 0 0 0 +Class 1 alarm MODBUS_INPUT_REGISTER 2195 1 4 0 0 0 +Frost protection status MODBUS_INPUT_REGISTER 1018 1 5 0 0 0 +Cooling status MODBUS_INPUT_REGISTER 1019 1 4 0 0 0 +id:1726 MODBUS_HOLDING_REGISTER 2757 1 2 0 30000 0 +Total run time additional heat MODBUS_INPUT_REGISTER 1025 10 h 3 0 1000000 0 +Power internal additional heat MODBUS_INPUT_REGISTER 1027 100 kW 2 0 0 0 +id:1757 MODBUS_HOLDING_REGISTER 2758 1 4 0 1 0 +Priority MODBUS_INPUT_REGISTER 1028 1 4 0 0 0 +Operating mode internal add. heat MODBUS_INPUT_REGISTER 1029 1 4 0 0 0 +Oper. mode shunt climate system 4 MODBUS_INPUT_REGISTER 1030 1 4 0 0 0 +Oper. mode shunt climate system 3 MODBUS_INPUT_REGISTER 1031 1 4 0 0 0 +Oper. mode shunt climate system 2 MODBUS_INPUT_REGISTER 1032 1 4 0 0 0 +Oper. mode shunt climate system 1 MODBUS_INPUT_REGISTER 1033 1 4 0 0 0 +Operating. mode shunt controlled additional heat MODBUS_INPUT_REGISTER 1034 1 4 0 0 0 +Fan mode 1 MODBUS_INPUT_REGISTER 1037 1 % 4 0 0 0 +Current hot water mode MODBUS_INPUT_REGISTER 1038 1 1 0 0 0 +Min frequency compressor MODBUS_INPUT_REGISTER 1041 1 Hz 2 0 0 0 +Max frequency compressor MODBUS_INPUT_REGISTER 1042 1 Hz 2 0 0 0 +Compressor frequency, current MODBUS_INPUT_REGISTER 1046 10 Hz 5 0 0 0 +Inverter temperature MODBUS_INPUT_REGISTER 1047 10 °C 2 0 0 0 +Compressor power input MODBUS_INPUT_REGISTER 1048 1 W 5 0 0 0 +Current compressor MODBUS_INPUT_REGISTER 1052 1 mA 2 0 0 0 +Blocking cooling MODBUS_INPUT_REGISTER 1053 1 4 0 0 0 +External adjustment climate system 4 MODBUS_INPUT_REGISTER 1054 1 4 0 0 0 +External adjustment climate system 3 MODBUS_INPUT_REGISTER 1055 1 4 0 0 0 +External adjustment climate system 2 MODBUS_INPUT_REGISTER 1056 1 4 0 0 0 +External adjustment climate system 1 MODBUS_INPUT_REGISTER 1057 1 4 0 0 0 +External blocking MODBUS_INPUT_REGISTER 1058 1 4 0 0 0 +Blocked MODBUS_INPUT_REGISTER 1059 1 4 0 0 0 +External blocking, active cooling (HPAC) MODBUS_INPUT_REGISTER 1060 1 4 0 0 0 +External blocking, passive cooling (HPAC) MODBUS_INPUT_REGISTER 1061 1 4 0 0 0 +Step controlled add. heat blocking MODBUS_INPUT_REGISTER 1062 1 4 0 0 0 +Hot water circulation (GP11) MODBUS_INPUT_REGISTER 1063 1 4 0 0 0 +Compressor frequency MODBUS_INPUT_REGISTER 1065 1 Hz 5 0 0 0 +Total HW run time additional heat MODBUS_INPUT_REGISTER 1069 10 h 3 0 9999999 0 +Compressor power input, average MODBUS_INPUT_REGISTER 1075 1 W 2 0 0 0 +More hot water status MODBUS_INPUT_REGISTER 1078 1 4 0 0 0 +Relay status (HPAC) MODBUS_INPUT_REGISTER 1079 1 4 0 0 0 +Holiday function status MODBUS_HOLDING_REGISTER 19 1 1 0 0 0 +Compressor starter MODBUS_INPUT_REGISTER 1083 1 3 -2147483648 2147483647 0 +Total run time compressor MODBUS_INPUT_REGISTER 1087 1 h 3 -2147483648 2147483647 0 +Total run time compressor hot water MODBUS_INPUT_REGISTER 1091 1 h 3 -2147483648 2147483647 0 +Operating mode compressor MODBUS_INPUT_REGISTER 1094 1 4 0 0 0 +Operating mode heating medium pump MODBUS_INPUT_REGISTER 1096 1 4 0 0 0 +Operating mode brine pump MODBUS_INPUT_REGISTER 1098 1 4 0 0 0 +Compressor status MODBUS_INPUT_REGISTER 1100 1 4 0 0 0 +Heating medium pump speed (GP1) MODBUS_INPUT_REGISTER 1102 1 % 4 0 0 0 +Brine pump speed (GP2) MODBUS_INPUT_REGISTER 1104 1 % 4 0 0 0 +Docked compressors heating MODBUS_INPUT_REGISTER 1108 1 4 0 0 0 +Docked compressors hot water MODBUS_INPUT_REGISTER 1109 1 4 0 0 0 +Docked compressors pool 1 MODBUS_INPUT_REGISTER 1110 1 4 0 0 0 +Reversing valve hot water (QN10) MODBUS_INPUT_REGISTER 2196 1 4 0 0 0 +Cooling activated (FLM 4) MODBUS_INPUT_REGISTER 1111 1 4 0 0 0 +Cooling activated (FLM 3) MODBUS_INPUT_REGISTER 1112 1 4 0 0 0 +Cooling activated (FLM 2) MODBUS_INPUT_REGISTER 1113 1 4 0 0 0 +Cooling activated (FLM 1) MODBUS_INPUT_REGISTER 1114 1 4 0 0 0 +Relay status, base board (EB100-EP14) MODBUS_INPUT_REGISTER 1117 1 4 0 0 0 +Relay status, imm. heat. board (EB100-EP14) MODBUS_INPUT_REGISTER 1119 1 4 0 0 0 +Current status MODBUS_INPUT_REGISTER 1120 1 6 0 0 0 +Functionality, heat pump (EP14) MODBUS_INPUT_REGISTER 1122 1 6 0 0 0 +Active heat pumps MODBUS_INPUT_REGISTER 1124 1 5 0 0 0 +Functionality, heat pump (EP15) MODBUS_INPUT_REGISTER 1125 1 6 0 0 0 +Operating mode HW comfort MODBUS_INPUT_REGISTER 1129 1 4 0 0 0 +Operating mode HW comfort additional heat MODBUS_INPUT_REGISTER 1130 1 4 0 0 0 +Blocked MODBUS_INPUT_REGISTER 1131 1 4 0 0 0 +Blocked MODBUS_INPUT_REGISTER 1132 1 4 0 0 0 +Pool 2 (QN19) MODBUS_INPUT_REGISTER 1133 1 4 0 0 0 +Pool 1 (QN19) MODBUS_INPUT_REGISTER 1134 1 4 0 0 0 +Docked compressors pool 2 MODBUS_INPUT_REGISTER 1135 1 4 0 0 0 +Version (EB100) MODBUS_INPUT_REGISTER 1496 1 5 0 0 0 +Heat pump type (EB100) MODBUS_INPUT_REGISTER 1497 1 4 0 0 0 +Compressor size (EB100) MODBUS_INPUT_REGISTER 1498 1 4 0 0 0 +Compressor, oper. time, total (EB100-EP15) MODBUS_INPUT_REGISTER 1515 1 h 6 0 0 0 +Compressor, oper. time, hot water (EB100-EP15) MODBUS_INPUT_REGISTER 1517 1 h 6 0 0 0 +Return line (EB100-BT3) MODBUS_INPUT_REGISTER 1520 10 °C 2 0 0 0 +Brine in (EB100-BT10) MODBUS_INPUT_REGISTER 1521 10 °C 2 0 0 0 +Brine out (EB100-BT11) MODBUS_INPUT_REGISTER 1522 10 °C 2 0 0 0 +Condenser (EB100-BT2) MODBUS_INPUT_REGISTER 1523 10 °C 2 0 0 0 +Discharge (EB100-BT14) MODBUS_INPUT_REGISTER 1524 10 °C 2 0 0 0 +Liquid line (EB100-BT15) MODBUS_INPUT_REGISTER 1525 10 °C 2 0 0 0 +Suction gas (EB100-BT17) MODBUS_INPUT_REGISTER 1526 10 °C 2 0 0 0 +Compressor sensor (EB100-BT29) MODBUS_INPUT_REGISTER 1527 10 °C 2 0 0 0 +Low press (EB100-BP8) MODBUS_INPUT_REGISTER 1528 10 °C 2 0 0 0 +Compressor status (EB100) MODBUS_INPUT_REGISTER 1529 1 4 0 0 0 +Compressor, time to start (EB100-EP14) MODBUS_INPUT_REGISTER 1530 1 min 4 0 0 0 +Relay status (EB100-EP14) MODBUS_INPUT_REGISTER 1531 1 5 0 0 0 +Heating medium pump (EB100) MODBUS_INPUT_REGISTER 1532 1 % 4 0 0 0 +Brine pump (EB100) MODBUS_INPUT_REGISTER 1533 1 % 4 0 0 0 +Compressor, number of starts (EB100-EP14) MODBUS_INPUT_REGISTER 1534 1 6 0 0 0 +Compressor, oper. time, total (EB100-EP14) MODBUS_INPUT_REGISTER 1536 1 h 6 0 0 0 +Compressor, oper. time, hot water (EB100-EP14) MODBUS_INPUT_REGISTER 1538 1 h 6 0 0 0 +Compressor, requested (EB108-EP15) MODBUS_INPUT_REGISTER 1541 1 4 0 0 0 +Compressor, requested (EB108-EP14) MODBUS_INPUT_REGISTER 1542 1 4 0 0 0 +Compressor, requested (EB107-EP15) MODBUS_INPUT_REGISTER 1543 1 4 0 0 0 +Compressor, requested (EB107-EP14) MODBUS_INPUT_REGISTER 1544 1 4 0 0 0 +Compressor, requested (EB106-EP15) MODBUS_INPUT_REGISTER 1545 1 4 0 0 0 +Compressor, requested (EB106-EP14) MODBUS_INPUT_REGISTER 1546 1 4 0 0 0 +Compressor, requested (EB105-EP15) MODBUS_INPUT_REGISTER 1547 1 4 0 0 0 +Compressor, requested (EB105-EP14) MODBUS_INPUT_REGISTER 1548 1 4 0 0 0 +Compressor, requested (EB104-EP15) MODBUS_INPUT_REGISTER 1549 1 4 0 0 0 +Compressor, requested (EB104-EP14) MODBUS_INPUT_REGISTER 1550 1 4 0 0 0 +Compressor, requested (EB103-EP15) MODBUS_INPUT_REGISTER 1551 1 4 0 0 0 +Compressor, requested (EB103-EP14) MODBUS_INPUT_REGISTER 1552 1 4 0 0 0 +Compressor, requested (EB102-EP15) MODBUS_INPUT_REGISTER 1553 1 4 0 0 0 +Compressor, requested (EB102-EP14) MODBUS_INPUT_REGISTER 1554 1 4 0 0 0 +Compressor, requested (EB101-EP15) MODBUS_INPUT_REGISTER 1555 1 4 0 0 0 +Compressor, requested (EB101-EP14) MODBUS_INPUT_REGISTER 1556 1 4 0 0 0 +Date, periodic hot water MODBUS_INPUT_REGISTER 1561 1 - - - - +Blocked compressors MODBUS_INPUT_REGISTER 2174 1 6 0 0 0 +Cooling degree minutes MODBUS_HOLDING_REGISTER 20 10 DM 2 -30000 30000 0 +Calculated cooling supply climate system 2 MODBUS_INPUT_REGISTER 1566 10 °C 2 0 0 0 +Calculated cooling supply climate system 1 MODBUS_INPUT_REGISTER 1567 10 °C 2 0 0 0 +Status (ACS) MODBUS_INPUT_REGISTER 1568 1 4 0 0 0 +Status, heating dumping (ACS) MODBUS_INPUT_REGISTER 1569 1 4 0 0 0 +Status, cooling dumping (ACS) MODBUS_INPUT_REGISTER 1570 1 4 0 0 0 +Used compressors hot water MODBUS_INPUT_REGISTER 1571 1 4 0 0 0 +Used compressors heating MODBUS_INPUT_REGISTER 1572 1 4 0 0 0 +Used compressors pool 1 MODBUS_INPUT_REGISTER 1573 1 4 0 0 0 +Used compressors pool 2 MODBUS_INPUT_REGISTER 1574 1 4 0 0 0 +id:2728 MODBUS_HOLDING_REGISTER 3099 1 3 0 9999999 0 +Used compressors cooling MODBUS_INPUT_REGISTER 1588 1 4 0 0 0 +(EB100-EP15-BT28) MODBUS_INPUT_REGISTER 1623 10 °C 2 0 0 0 +(EB100-EP15-BT16) MODBUS_INPUT_REGISTER 1624 10 °C 2 0 0 0 +(EB100-EP14-BT28) MODBUS_INPUT_REGISTER 1625 10 °C 2 0 0 0 +(EB100-EP14-BT16) MODBUS_INPUT_REGISTER 1626 10 °C 2 0 0 0 +Docked compressors external control MODBUS_INPUT_REGISTER 1628 1 4 0 0 0 +Bit register (EB100) MODBUS_INPUT_REGISTER 1687 1 4 0 0 0 +Controlling hot water sensor (EB100-BT6) MODBUS_INPUT_REGISTER 1688 10 °C 2 0 0 0 +Display hot water sensor (EB100-BT7) MODBUS_INPUT_REGISTER 1689 10 °C 2 0 0 0 +Supply temperature sensor (EB100-BT2) MODBUS_INPUT_REGISTER 1690 10 °C 2 0 0 0 +Compressor status (EB100-EP15) MODBUS_INPUT_REGISTER 1691 1 4 0 0 0 +Compressor status (EB100-EP14) MODBUS_INPUT_REGISTER 1692 1 4 0 0 0 +Docked compressors cooling MODBUS_INPUT_REGISTER 1694 1 4 0 0 0 +BP4, unprocessed (EB108-EP15) MODBUS_INPUT_REGISTER 1695 1 2 0 0 0 +Low pressure (EB108-EP15--BP8) MODBUS_INPUT_REGISTER 1697 10 bar 2 0 0 0 +Prot. status (EB108-EP15) MODBUS_INPUT_REGISTER 1699 1 5 0 0 0 +Defrosting (EB108-EP15) MODBUS_INPUT_REGISTER 1700 1 4 0 0 0 +BP4, unprocessed (EB108-EP14) MODBUS_INPUT_REGISTER 1702 1 2 0 0 0 +Defrosting (EB108) MODBUS_INPUT_REGISTER 1707 1 4 0 0 0 +BP4, unprocessed (EB107-EP15) MODBUS_INPUT_REGISTER 1709 1 2 0 0 0 +Low pressure (EB107-EP15--BP8) MODBUS_INPUT_REGISTER 1711 10 bar 2 0 0 0 +Prot. status (EB107-EP15) MODBUS_INPUT_REGISTER 1713 1 5 0 0 0 +Defrosting (EB107-EP15) MODBUS_INPUT_REGISTER 1714 1 4 0 0 0 +Power (EB107-EP15) MODBUS_INPUT_REGISTER 1715 1 kW 4 0 0 0 +BP4, unprocessed (EB107-EP14) MODBUS_INPUT_REGISTER 1716 1 2 0 0 0 +Defrosting (EB107) MODBUS_INPUT_REGISTER 1721 1 4 0 0 0 +Power (EB107-EP14) MODBUS_INPUT_REGISTER 1722 1 kW 4 0 0 0 +BP4, unprocessed (EB106-EP15) MODBUS_INPUT_REGISTER 1723 1 2 0 0 0 +Low pressure (EB106-EP15--BP8) MODBUS_INPUT_REGISTER 1725 10 bar 2 0 0 0 +Prot. status (EB106-EP15) MODBUS_INPUT_REGISTER 1727 1 5 0 0 0 +Defrosting (EB106-EP15) MODBUS_INPUT_REGISTER 1728 1 4 0 0 0 +Power (EB106-EP15) MODBUS_INPUT_REGISTER 1729 1 kW 4 0 0 0 +BP4, unprocessed (EB106-EP14) MODBUS_INPUT_REGISTER 1730 1 2 0 0 0 +Defrosting (EB106) MODBUS_INPUT_REGISTER 1735 1 4 0 0 0 +Power (EB106-EP14) MODBUS_INPUT_REGISTER 1736 1 kW 4 0 0 0 +BP4, unprocessed (EB105-EP15) MODBUS_INPUT_REGISTER 1737 1 2 0 0 0 +Low pressure (EB105-EP15--BP8) MODBUS_INPUT_REGISTER 1739 10 bar 2 0 0 0 +Prot. status (EB105-EP15) MODBUS_INPUT_REGISTER 1741 1 5 0 0 0 +Defrosting (EB105-EP15) MODBUS_INPUT_REGISTER 1742 1 4 0 0 0 +Power (EB105-EP15) MODBUS_INPUT_REGISTER 1743 1 kW 4 0 0 0 +BP4, unprocessed (EB105-EP14) MODBUS_INPUT_REGISTER 1744 1 2 0 0 0 +Defrosting (EB105) MODBUS_INPUT_REGISTER 1749 1 4 0 0 0 +Power (EB105-EP15) MODBUS_INPUT_REGISTER 1750 1 kW 4 0 0 0 +BP4, unprocessed (EB104-EP15) MODBUS_INPUT_REGISTER 1751 1 2 0 0 0 +Low pressure (EB104-EP15--BP8) MODBUS_INPUT_REGISTER 1753 10 bar 2 0 0 0 +Prot. status (EB104-EP15) MODBUS_INPUT_REGISTER 1755 1 5 0 0 0 +Low pressure (EB103-EP15--BP8) MODBUS_INPUT_REGISTER 1767 10 bar 2 0 0 0 +BP4, unprocessed (EB103-EP14) MODBUS_INPUT_REGISTER 1772 1 2 0 0 0 +Defrosting (EB103) MODBUS_INPUT_REGISTER 1777 1 4 0 0 0 +Power (EB103-EP14) MODBUS_INPUT_REGISTER 1778 1 kW 4 0 0 0 +BP4, unprocessed (EB102-EP15) MODBUS_INPUT_REGISTER 1779 1 2 0 0 0 +Low pressure (EB102-EP15--BP8) MODBUS_INPUT_REGISTER 1781 10 bar 2 0 0 0 +Prot. status (EB102-EP15) MODBUS_INPUT_REGISTER 1783 1 5 0 0 0 +Defrosting (EB102-EP15) MODBUS_INPUT_REGISTER 1784 1 4 0 0 0 +Power (EB102-EP15) MODBUS_INPUT_REGISTER 1785 1 kW 4 0 0 0 +BP4, unprocessed (EB102-EP14) MODBUS_INPUT_REGISTER 1786 1 2 0 0 0 +Defrosting (EB102) MODBUS_INPUT_REGISTER 1791 1 4 0 0 0 +Power (EB102-EP14) MODBUS_INPUT_REGISTER 1792 1 kW 4 0 0 0 +BP4, unprocessed (EB101-EP15) MODBUS_INPUT_REGISTER 1793 1 2 0 0 0 +Low pressure (EB101-EP15-BP8) MODBUS_INPUT_REGISTER 1795 10 bar 2 0 0 0 +Prot. status (EB101-EP15) MODBUS_INPUT_REGISTER 1797 1 5 0 0 0 +Defrosting (EB101-EP15) MODBUS_INPUT_REGISTER 1798 1 4 0 0 0 +Power (EB101-EP15) MODBUS_INPUT_REGISTER 1799 1 kW 4 0 0 0 +BP4, unprocessed (EB101-EP14) MODBUS_INPUT_REGISTER 1800 1 2 0 0 0 +Defrosting (EB101) MODBUS_INPUT_REGISTER 1805 1 4 0 0 0 +Power (EB101-EP14) MODBUS_INPUT_REGISTER 1806 1 kW 4 0 0 0 +BP4, unprocessed (EB100-EP15) MODBUS_INPUT_REGISTER 1807 1 2 0 0 0 +Pressure sensor, condenser (EB100-EP15-BP4) MODBUS_INPUT_REGISTER 1808 10 bar 2 0 0 0 +Low pressure (EB100-EP15-BP8) MODBUS_INPUT_REGISTER 1809 10 bar 2 0 0 0 +Prot. status (EB100-EP15) MODBUS_INPUT_REGISTER 1811 1 5 0 0 0 +Defrosting (EB100-EP15) MODBUS_INPUT_REGISTER 1812 1 4 0 0 0 +Power (EB100-EP15) MODBUS_INPUT_REGISTER 1813 1 kW 4 0 0 0 +BP4, unprocessed (EB100-EP14) MODBUS_INPUT_REGISTER 1814 1 2 0 0 0 +Pressure sensor, condenser (EB100-EP14-BP4) MODBUS_INPUT_REGISTER 1815 10 bar 2 0 0 0 +Low pressure (EB100-EP14-BP8) MODBUS_INPUT_REGISTER 1816 10 bar 2 0 0 0 +Prot. status (EB100-EP14) MODBUS_INPUT_REGISTER 1818 1 5 0 0 0 +Defrosting (EB100-EP14) MODBUS_INPUT_REGISTER 1819 1 4 0 0 0 +Power (EB100-EP14) MODBUS_INPUT_REGISTER 1820 1 kW 4 0 0 0 +Climate system 4 MODBUS_INPUT_REGISTER 1823 1 4 0 0 0 +Climate system 3 MODBUS_INPUT_REGISTER 1824 1 4 0 0 0 +Climate system 2 MODBUS_INPUT_REGISTER 1825 1 4 0 0 0 +Climate system 1 (HMP) MODBUS_INPUT_REGISTER 1826 1 4 0 0 0 +Pool 2 pump status MODBUS_INPUT_REGISTER 1827 1 4 0 0 0 +Pool 1 pump status MODBUS_INPUT_REGISTER 1828 1 4 0 0 0 +ACS EQ1-QN12 MODBUS_INPUT_REGISTER 1830 1 4 0 0 0 +ACS EQ1-GP20 MODBUS_INPUT_REGISTER 1831 1 4 0 0 0 +Passive cooling shunt MODBUS_INPUT_REGISTER 1832 1 4 0 0 0 +Passive cooling pump (GP13) MODBUS_INPUT_REGISTER 1833 1 4 0 0 0 +Oper. mode groundwater pump MODBUS_INPUT_REGISTER 1835 1 4 0 0 0 +Alarm number (EB100-EP15) MODBUS_INPUT_REGISTER 1837 1 5 0 0 0 +Alarm number (EB100-EP14) MODBUS_INPUT_REGISTER 1838 1 5 0 0 0 +Requested compressor frequency (EB108-EP15) MODBUS_INPUT_REGISTER 1839 1 Hz 4 0 0 0 +Requested compressor frequency (EB107-EP15) MODBUS_INPUT_REGISTER 1841 1 Hz 4 0 0 0 +Requested compressor frequency (EB106-EP15) MODBUS_INPUT_REGISTER 1843 1 Hz 4 0 0 0 +Requested compressor frequency (EB105-EP15) MODBUS_INPUT_REGISTER 1845 1 Hz 4 0 0 0 +Requested compressor frequency (EB104-EP15) MODBUS_INPUT_REGISTER 1847 1 Hz 4 0 0 0 +Requested compressor frequency (EB103-EP15) MODBUS_INPUT_REGISTER 1849 1 Hz 4 0 0 0 +Requested compressor frequency (EB102-EP15) MODBUS_INPUT_REGISTER 1851 1 Hz 4 0 0 0 +Requested compressor frequency (EB101-EP15) MODBUS_INPUT_REGISTER 1853 1 Hz 4 0 0 0 +Requested compressor frequency (EP15) MODBUS_INPUT_REGISTER 1855 1 Hz 4 0 0 0 +Requested compressor frequency MODBUS_INPUT_REGISTER 1856 1 Hz 4 0 0 0 +Operating mode, shunt controlled brine (QN41) MODBUS_INPUT_REGISTER 2410 1 4 0 0 0 +Low press. sensor, unprocessed (EB100-EP15) MODBUS_INPUT_REGISTER 1905 1 2 0 0 0 +Current sensor (EB100-EP15) MODBUS_INPUT_REGISTER 1906 10 A 2 0 0 0 +Low press. sensor, unprocessed (EB100-EP14) MODBUS_INPUT_REGISTER 1908 1 2 0 0 0 +Current sensor (EB100-EP14) MODBUS_INPUT_REGISTER 1909 10 A 2 0 0 0 +Operating mode (SG Ready) MODBUS_INPUT_REGISTER 1911 1 4 0 0 0 +SG ready, input A MODBUS_INPUT_REGISTER 1912 1 4 0 0 0 +SG ready, input B MODBUS_INPUT_REGISTER 1913 1 4 0 0 0 +Hot water comfort mode (SPA) MODBUS_INPUT_REGISTER 1915 1 1 0 0 0 +Pool offset (SPA) MODBUS_INPUT_REGISTER 1916 1 1 0 0 0 +Cooling offset (SPA) MODBUS_INPUT_REGISTER 1917 1 1 0 0 0 +Operating mode (Smart Price Adaption) MODBUS_INPUT_REGISTER 1918 1 4 0 0 0 +Brine pump dT current MODBUS_INPUT_REGISTER 1919 10 2 0 0 0 +Brine pump dT set point value MODBUS_INPUT_REGISTER 1920 10 2 0 0 0 +Evaporator 2 (EB100-EP15-BT16) MODBUS_INPUT_REGISTER 1969 10 °C 2 0 0 0 +Temperature, inverter (EB100-EP15) MODBUS_INPUT_REGISTER 1970 10 °C 2 0 0 0 +fan speed (EB100-EP15) MODBUS_INPUT_REGISTER 1971 1 4 0 0 0 +Evaporator 2 (EB100-EP14-BT16) MODBUS_INPUT_REGISTER 1972 10 °C 2 0 0 0 +Temperature, inverter (EB100-EP14) MODBUS_INPUT_REGISTER 1973 10 °C 2 0 0 0 +fan speed (EB100-EP14) MODBUS_INPUT_REGISTER 1974 1 4 0 0 0 +Alarm number MODBUS_INPUT_REGISTER 1975 1 2 0 0 0 +Reset alarm MODBUS_HOLDING_REGISTER 22 1 4 0 0 0 +Non module-specific alarm numbers MODBUS_INPUT_REGISTER 1976 1 2 0 0 0 +Heating curve climate system 2 MODBUS_HOLDING_REGISTER 25 1 1 0 15 9 +Heating curve climate system 1 MODBUS_HOLDING_REGISTER 26 1 1 0 15 9 +Heating offset climate system 2 MODBUS_HOLDING_REGISTER 29 1 1 -10 10 0 +Heating offset climate system 1 MODBUS_HOLDING_REGISTER 30 1 1 -10 10 0 +Min supply climate system 2 MODBUS_HOLDING_REGISTER 33 10 °C 2 50 800 200 +Min supply climate system 1 MODBUS_HOLDING_REGISTER 34 10 °C 2 50 800 200 +Max supply climate system 2 MODBUS_HOLDING_REGISTER 37 10 °C 2 50 800 600 +Max supply climate system 1 MODBUS_HOLDING_REGISTER 38 10 °C 2 50 800 600 +Own curve, heating P7 MODBUS_HOLDING_REGISTER 39 1 °C 1 5 80 15 +Own curve, heating P6 MODBUS_HOLDING_REGISTER 40 1 °C 1 5 80 15 +Own curve, heating P5 MODBUS_HOLDING_REGISTER 41 1 °C 1 5 80 26 +Own curve, heating P4 MODBUS_HOLDING_REGISTER 42 1 °C 1 5 80 32 +Own curve, heating P3 MODBUS_HOLDING_REGISTER 43 1 °C 1 5 80 35 +Own curve, heating P2 MODBUS_HOLDING_REGISTER 44 1 °C 1 5 80 40 +Own curve, heating P1 MODBUS_HOLDING_REGISTER 45 1 °C 1 5 80 45 +Point offset outdoor temperature MODBUS_HOLDING_REGISTER 46 1 °C 1 -40 30 0 +Point offset MODBUS_HOLDING_REGISTER 47 1 °C 1 -10 10 0 +External adjustment climate system 2 MODBUS_HOLDING_REGISTER 50 1 1 -10 10 0 +External adjustment climate system 1 MODBUS_HOLDING_REGISTER 51 1 1 -10 10 0 +External adjustment with room sensor climate system 2 MODBUS_HOLDING_REGISTER 54 10 °C 2 50 300 200 +External adjustment with room sensor climate system 1 MODBUS_HOLDING_REGISTER 55 10 °C 2 50 300 200 +Hot water demand mode MODBUS_HOLDING_REGISTER 56 1 1 0 4 1 +Start temperature HW high temperature MODBUS_HOLDING_REGISTER 58 10 °C 2 50 700 530 +Start temperature HW normal temperature MODBUS_HOLDING_REGISTER 59 10 °C 2 50 600 480 +Start temperature HW low temperature MODBUS_HOLDING_REGISTER 60 10 °C 2 50 550 450 +Stop temperature HW periodic increase MODBUS_HOLDING_REGISTER 61 10 °C 2 550 700 550 +Stop temperature HW high temperature MODBUS_HOLDING_REGISTER 62 10 °C 2 50 700 550 +Stop temperature HW normal temperature MODBUS_HOLDING_REGISTER 63 10 °C 2 50 650 510 +Stop temperature HW low temperature MODBUS_HOLDING_REGISTER 64 10 °C 2 50 600 480 +Periodic hot water MODBUS_HOLDING_REGISTER 65 1 1 0 1 1 +Periodic hot water interval MODBUS_HOLDING_REGISTER 66 1 days 1 1 90 7 +Start time periodic hot water MODBUS_HOLDING_REGISTER 67 1 - - - - +Hot water circulation MODBUS_HOLDING_REGISTER 2754 1 4 0 1 0 +Language MODBUS_HOLDING_REGISTER 91 1 1 0 24 0 +Period time hot water MODBUS_HOLDING_REGISTER 92 1 min 4 0 180 30 +Period time heating MODBUS_HOLDING_REGISTER 93 1 min 4 0 180 30 +Operating mode MODBUS_HOLDING_REGISTER 2743 1 4 0 2 0 +Operating mode heating medium pump MODBUS_HOLDING_REGISTER 95 1 4 10 40 40 +Operating mode brine pump MODBUS_HOLDING_REGISTER 96 1 4 10 30 10 +Activate forced control MODBUS_HOLDING_REGISTER 5000 1 4 0 0 0 +DM start heating MODBUS_HOLDING_REGISTER 97 1 DM 2 -1000 -30 -60 +DM between additional heat step MODBUS_HOLDING_REGISTER 100 1 DM 2 10 1000 100 +Max. internal additional heat MODBUS_HOLDING_REGISTER 102 100 kW 2 0 4500 700 +Fuse MODBUS_HOLDING_REGISTER 103 1 A 5 1 400 16 +id:3826 MODBUS_HOLDING_REGISTER 2747 1 4 1 128 4 +id:3827 MODBUS_HOLDING_REGISTER 2746 1 4 1 128 2 +id:3828 MODBUS_HOLDING_REGISTER 2745 1 4 1 128 1 +Floor drying MODBUS_HOLDING_REGISTER 120 1 4 0 1 0 +Floor drying period 7 MODBUS_HOLDING_REGISTER 121 1 days 4 0 30 2 +Floor drying period 6 MODBUS_HOLDING_REGISTER 122 1 days 4 0 30 2 +Floor drying period 5 MODBUS_HOLDING_REGISTER 123 1 days 4 0 30 2 +Floor drying period 4 MODBUS_HOLDING_REGISTER 124 1 days 4 0 30 3 +Floor drying period 3 MODBUS_HOLDING_REGISTER 125 1 days 4 0 30 2 +Floor drying period 2 MODBUS_HOLDING_REGISTER 126 1 days 4 0 30 2 +Floor drying period 1 MODBUS_HOLDING_REGISTER 127 1 days 4 0 30 2 +Floor drying temp. 7 MODBUS_HOLDING_REGISTER 128 1 °C 4 15 70 20 +Floor drying temp. 6 MODBUS_HOLDING_REGISTER 129 1 °C 4 15 70 30 +Floor drying temp. 5 MODBUS_HOLDING_REGISTER 130 1 °C 4 15 70 40 +Floor drying temp. 4 MODBUS_HOLDING_REGISTER 131 1 °C 4 15 70 45 +Floor drying temp. 3 MODBUS_HOLDING_REGISTER 132 1 °C 4 15 70 40 +Floor drying temp. 2 MODBUS_HOLDING_REGISTER 133 1 °C 4 15 70 30 +Floor drying temp. 1 MODBUS_HOLDING_REGISTER 134 1 °C 4 15 70 20 +Floor drying ongoing time. MODBUS_INPUT_REGISTER 1977 1 5 0 10000 0 +Dimensioned outdoor temperature MODBUS_HOLDING_REGISTER 140 10 °C 2 -400 200 -180 +Delta T for DOT MODBUS_HOLDING_REGISTER 141 10 °C 2 10 250 100 +Climate system 2 MODBUS_HOLDING_REGISTER 142 1 4 0 1 0 +Climate system 3 MODBUS_HOLDING_REGISTER 143 1 4 0 1 0 +Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0 +Climate system 2 shunt amplification MODBUS_HOLDING_REGISTER 147 10 1 1 100 10 +Climate system 2 shunt wait time MODBUS_HOLDING_REGISTER 150 1 s 2 10 300 30 +Shunt controlled additional heat MODBUS_HOLDING_REGISTER 153 1 4 0 1 0 +Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30 +Step controlled additional heat accessory MODBUS_HOLDING_REGISTER 158 1 4 0 1 0 +Ground water pump accessory MODBUS_HOLDING_REGISTER 162 1 4 0 1 0 +PCI accessories MODBUS_HOLDING_REGISTER 1980 1 4 0 1 0 +Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2 +Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10 +Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30 +Cooling shunt amplification MODBUS_HOLDING_REGISTER 168 10 1 1 100 10 +Cooling shunt waiting time MODBUS_HOLDING_REGISTER 169 1 s 2 10 300 30 +Cooling with room sensors MODBUS_HOLDING_REGISTER 170 10 4 0 41 0 +Start passive cooling DM MODBUS_HOLDING_REGISTER 172 1 DM 2 10 500 30 +Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 90 +Changes have been made MODBUS_HOLDING_REGISTER 2744 1 4 0 1 0 +Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1 +Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1 +Permit cooling MODBUS_HOLDING_REGISTER 182 1 4 0 1 1 +Auto mode, stop temperature for heating MODBUS_HOLDING_REGISTER 184 10 °C 2 -200 400 170 +Auto mode, additional heat stop temperature MODBUS_HOLDING_REGISTER 185 10 °C 2 -250 400 50 +Auto mode filter time MODBUS_HOLDING_REGISTER 186 1 h 4 0 48 24 +Max difference supply, compressor MODBUS_HOLDING_REGISTER 187 10 °C 2 10 250 100 +Max difference supply, additional heat MODBUS_HOLDING_REGISTER 188 10 °C 2 10 240 30 +Low brine alarm auto reset MODBUS_HOLDING_REGISTER 189 1 4 0 1 0 +Low brine out alarm temperature (EP14) MODBUS_HOLDING_REGISTER 190 10 °C 2 -120 150 -80 +High brine in alarm active MODBUS_HOLDING_REGISTER 191 1 4 1 1 1 +High brine in alarm temperature MODBUS_HOLDING_REGISTER 192 10 °C 2 100 350 350 +Time format MODBUS_HOLDING_REGISTER 194 1 4 0 1 1 +Hot water permitted MODBUS_HOLDING_REGISTER 195 1 4 0 1 0 +Alarm action, lower room temperature MODBUS_HOLDING_REGISTER 196 1 4 0 1 0 +Alarm action lower HW temperature MODBUS_HOLDING_REGISTER 197 1 4 0 1 1 +Auxiliary operation on alarm MODBUS_HOLDING_REGISTER 198 1 4 0 0 0 +Use room sensor climate system 4 MODBUS_HOLDING_REGISTER 199 1 4 0 1 0 +Use room sensor climate system 3 MODBUS_HOLDING_REGISTER 200 1 4 0 1 0 +Use room sensor climate system 2 MODBUS_HOLDING_REGISTER 201 1 4 0 1 0 +Use room sensor climate system 1 MODBUS_HOLDING_REGISTER 202 1 4 0 1 0 +Room sensor set point value climate system 4 MODBUS_HOLDING_REGISTER 203 10 °C 2 50 300 200 +Room sensor set point value climate system 3 MODBUS_HOLDING_REGISTER 204 10 °C 2 50 300 200 +Room sensor set point value climate system 2 MODBUS_HOLDING_REGISTER 205 10 °C 2 50 300 200 +Room sensor set point value climate system 1 MODBUS_HOLDING_REGISTER 206 10 °C 2 50 300 200 +Room sensor factor climate system 4 MODBUS_HOLDING_REGISTER 207 10 4 0 60 20 +Room sensor factor climate system 3 MODBUS_HOLDING_REGISTER 208 10 4 0 60 20 +Room sensor factor climate system 2 MODBUS_HOLDING_REGISTER 209 10 4 0 60 20 +Room sensor factor climate system 1 MODBUS_HOLDING_REGISTER 210 10 4 0 60 20 +Input AUX5 MODBUS_HOLDING_REGISTER 211 1 4 0 67 0 +Input AUX4 MODBUS_HOLDING_REGISTER 212 1 4 0 67 0 +Input AUX3 MODBUS_HOLDING_REGISTER 213 1 4 0 67 0 +Input AUX2 MODBUS_HOLDING_REGISTER 214 1 4 0 67 0 +Input AUX1 MODBUS_HOLDING_REGISTER 215 1 4 0 67 0 +Output AUX1 MODBUS_HOLDING_REGISTER 216 1 4 0 30 0 +Speed of circulation pump for hot water MODBUS_HOLDING_REGISTER 217 1 % 4 1 100 70 +Speed of circulation pump for heating MODBUS_HOLDING_REGISTER 218 1 % 4 1 100 70 +Speed, heating medium pump for pool MODBUS_HOLDING_REGISTER 219 1 % 4 1 100 70 +Speed heating medium pump waiting mode MODBUS_HOLDING_REGISTER 220 1 % 4 1 100 30 +Speed of circulation pump passive cooling (EP14) MODBUS_HOLDING_REGISTER 221 1 % 4 1 100 70 +Speed, brine pump MODBUS_HOLDING_REGISTER 222 1 % 4 1 100 100 +id:3968 MODBUS_HOLDING_REGISTER 2752 1 5 1 3600 5 +Preset flow setting for climate system MODBUS_HOLDING_REGISTER 223 1 4 0 3 1 +id:3977 MODBUS_HOLDING_REGISTER 2753 1 4 21 22 21 +More hot water (Number of minutes) MODBUS_HOLDING_REGISTER 225 1 5 0 0 0 +id:4045 MODBUS_HOLDING_REGISTER 5245 1 °C 1 1 40 8 +id:4046 MODBUS_HOLDING_REGISTER 5247 1 °C 1 0 40 4 +id:4049 MODBUS_HOLDING_REGISTER 5249 1 4 0 1 0 +id:4050 MODBUS_HOLDING_REGISTER 5250 1 4 0 1 0 +id:4051 MODBUS_HOLDING_REGISTER 5251 1 4 0 1 0 +Oper. mode MODBUS_HOLDING_REGISTER 237 1 4 0 0 0 +FLM 4 MODBUS_HOLDING_REGISTER 675 1 4 0 1 0 +FLM 3 MODBUS_HOLDING_REGISTER 676 1 4 0 1 0 +FLM 2 MODBUS_HOLDING_REGISTER 677 1 4 0 1 0 +FLM 1 MODBUS_HOLDING_REGISTER 678 1 4 0 1 0 +DM diff. start additional heat MODBUS_HOLDING_REGISTER 679 1 DM 2 100 2000 400 +Cooling heat sensor set point value MODBUS_HOLDING_REGISTER 681 10 2 50 400 210 +Pool 2 accessory MODBUS_HOLDING_REGISTER 684 1 4 0 1 0 +Pool 1 accessory MODBUS_HOLDING_REGISTER 685 1 4 0 1 0 +Hot water comfort MODBUS_HOLDING_REGISTER 694 1 4 0 1 0 +Manual heating medium pump speed MODBUS_HOLDING_REGISTER 695 1 % 1 0 1 0 +More hot water MODBUS_HOLDING_REGISTER 697 1 1 0 0 0 +Start diff. DM, step-controlled add. heat MODBUS_HOLDING_REGISTER 703 1 DM 2 0 2000 400 +HW comfort shunt on/off MODBUS_HOLDING_REGISTER 705 1 4 0 1 0 +HW comfort additional heat MODBUS_HOLDING_REGISTER 710 1 4 0 1 0 +Supp. air curve SAM, outd. temp. (T3) MODBUS_HOLDING_REGISTER 711 10 °C 2 -400 200 150 +Supp. air curve SAM, outd. temp. (T2) MODBUS_HOLDING_REGISTER 712 10 °C 2 -390 190 0 +Supp. air curve SAM, outd. temp. (T1) MODBUS_HOLDING_REGISTER 713 10 °C 2 -400 200 -150 +Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T3) MODBUS_HOLDING_REGISTER 714 10 °C 2 160 220 180 +Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T2) MODBUS_HOLDING_REGISTER 715 10 °C 2 160 220 180 +Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T1) MODBUS_HOLDING_REGISTER 716 10 °C 2 160 220 180 +id:4591 MODBUS_HOLDING_REGISTER 5256 1 1 5 80 30 +Min. supply temp. cooling climate system 2 MODBUS_HOLDING_REGISTER 719 1 °C 1 -5 30 18 +Min. supply temp. cooling climate system 1 MODBUS_HOLDING_REGISTER 720 1 °C 1 -5 30 18 +Own curve, cooling P3 MODBUS_HOLDING_REGISTER 721 1 °C 1 -5 40 20 +Own curve, cooling P5 MODBUS_HOLDING_REGISTER 722 1 °C 1 -5 40 20 +Cooling connected, climate system 2 MODBUS_HOLDING_REGISTER 725 1 4 0 1 0 +Cooling connected, climate system 1 MODBUS_HOLDING_REGISTER 726 1 4 0 1 1 +ACS MODBUS_HOLDING_REGISTER 731 1 4 0 1 0 +id:4617 MODBUS_HOLDING_REGISTER 5257 1 1 0 1 0 +id:4634 MODBUS_HOLDING_REGISTER 5258 1 1 0 1 1 +Max speed, regulator, charge/heating medium pump (EB100) MODBUS_HOLDING_REGISTER 740 1 % 4 50 100 100 +id:4660 MODBUS_HOLDING_REGISTER 5267 1 4 0 0 0 +Shunted brine, accessory MODBUS_HOLDING_REGISTER 5268 1 4 0 1 0 +Shunted brine max. temp. MODBUS_HOLDING_REGISTER 5271 1 °C 4 0 35 20 +Additional heat after reversing valve MODBUS_HOLDING_REGISTER 758 1 4 0 0 0 +Heating (SG Ready) MODBUS_HOLDING_REGISTER 760 1 4 0 1 1 +Set compressor frequency, cooling MODBUS_HOLDING_REGISTER 766 1 % 4 1 100 1 +id:4703 MODBUS_HOLDING_REGISTER 5272 1 4 0 1 0 +id:4704 MODBUS_HOLDING_REGISTER 5273 1 4 0 1 0 +id:4705 MODBUS_HOLDING_REGISTER 5274 1 4 0 1 0 +id:4706 MODBUS_HOLDING_REGISTER 5275 1 4 0 1 0 +id:4707 MODBUS_HOLDING_REGISTER 5276 1 4 0 1 0 +id:4708 MODBUS_HOLDING_REGISTER 5277 1 4 0 1 0 +id:4709 MODBUS_HOLDING_REGISTER 5278 1 4 0 1 0 +id:4710 MODBUS_HOLDING_REGISTER 5279 1 4 0 1 0 +Input AUX6 MODBUS_HOLDING_REGISTER 767 1 4 0 67 0 +Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 0 0 0 +Activated (Smart Price Adaption) MODBUS_HOLDING_REGISTER 843 1 4 0 1 0 +(SPA), cooling activated MODBUS_HOLDING_REGISTER 849 1 4 0 1 1 +(SPA), area MODBUS_HOLDING_REGISTER 851 1 4 0 255 255 +Automatic speed heating medium pump, hot water MODBUS_HOLDING_REGISTER 852 1 % 1 0 1 1 +Automatic speed heating medium pump, heating MODBUS_HOLDING_REGISTER 853 1 % 1 0 1 1 +Automatic speed heating medium pump, pool MODBUS_HOLDING_REGISTER 854 1 % 1 0 1 1 +Maximum speed of circulation pump for heating MODBUS_HOLDING_REGISTER 858 1 % 4 50 100 100 +Speed, brine pump, passive cooling mode MODBUS_HOLDING_REGISTER 859 1 % 4 0 100 75 +External adjustment climate system 8 MODBUS_HOLDING_REGISTER 893 1 1 -10 10 0 +External adjustment climate system 7 MODBUS_HOLDING_REGISTER 894 1 1 -10 10 0 +External adjustment climate system 6 MODBUS_HOLDING_REGISTER 895 1 1 -10 10 0 +External adjustment climate system 5 MODBUS_HOLDING_REGISTER 896 1 1 -10 10 0 +External adjustment with room sensor climate system 8 MODBUS_HOLDING_REGISTER 897 10 °C 2 50 300 200 +External adjustment with room sensor climate system 7 MODBUS_HOLDING_REGISTER 898 10 °C 2 50 300 200 +External adjustment with room sensor climate system 6 MODBUS_HOLDING_REGISTER 899 10 °C 2 50 300 200 +External adjustment with room sensor climate system 5 MODBUS_HOLDING_REGISTER 900 10 °C 2 50 300 200 +Initiate inverter MODBUS_HOLDING_REGISTER 903 1 4 0 0 0 +Force initiated inverter MODBUS_HOLDING_REGISTER 904 1 4 0 0 0 +Climate system 5 MODBUS_HOLDING_REGISTER 905 1 4 0 1 0 +Climate system 6 MODBUS_HOLDING_REGISTER 906 1 4 0 1 0 +Climate system 7 MODBUS_HOLDING_REGISTER 907 1 4 0 1 0 +Climate system 8 MODBUS_HOLDING_REGISTER 908 1 4 0 1 0 +Heating connected, climate system 2 MODBUS_HOLDING_REGISTER 931 1 4 0 1 1 +Heating connected, climate system 1 MODBUS_HOLDING_REGISTER 932 1 4 0 1 1 +ERS 1 MODBUS_HOLDING_REGISTER 933 1 4 0 1 0 +EB103/104-GP12 MODBUS_HOLDING_REGISTER 939 1 4 0 1 0 +EB105/106-GP12 MODBUS_HOLDING_REGISTER 940 1 4 0 1 0 +EB107/108-GP12 MODBUS_HOLDING_REGISTER 941 1 4 0 1 0 +BlockFreq 2 activated MODBUS_HOLDING_REGISTER 942 1 1 0 1 0 +BlockFreq 1 activated MODBUS_HOLDING_REGISTER 943 1 1 0 1 0 +id:4969 MODBUS_HOLDING_REGISTER 5295 1 4 0 1 0 +id:4970 MODBUS_HOLDING_REGISTER 5296 1 4 0 1 0 +id:4971 MODBUS_HOLDING_REGISTER 5297 1 Hz 4 20 117 20 +id:4972 MODBUS_HOLDING_REGISTER 5298 1 Hz 4 20 117 20 +id:4973 MODBUS_HOLDING_REGISTER 5299 1 Hz 4 23 120 23 +id:4974 MODBUS_HOLDING_REGISTER 5300 1 Hz 4 23 120 23 +Use room sensor climate system 8 MODBUS_HOLDING_REGISTER 948 1 4 0 1 0 +Use room sensor climate system 7 MODBUS_HOLDING_REGISTER 949 1 4 0 1 0 +Use room sensor climate system 6 MODBUS_HOLDING_REGISTER 950 1 4 0 1 0 +Use room sensor climate system 5 MODBUS_HOLDING_REGISTER 951 1 4 0 1 0 +Room sensor set point value climate system 8 MODBUS_HOLDING_REGISTER 952 10 °C 2 50 300 200 +Room sensor set point value climate system 7 MODBUS_HOLDING_REGISTER 953 10 °C 2 50 300 200 +Room sensor set point value climate system 6 MODBUS_HOLDING_REGISTER 954 10 °C 2 50 300 200 +Room sensor set point value climate system 5 MODBUS_HOLDING_REGISTER 955 10 °C 2 50 300 200 +Room sensor factor climate system 8 MODBUS_HOLDING_REGISTER 956 10 4 0 60 20 +Room sensor factor climate system 7 MODBUS_HOLDING_REGISTER 957 10 4 0 60 20 +Room sensor factor climate system 6 MODBUS_HOLDING_REGISTER 958 10 4 0 60 20 +Room sensor factor climate system 5 MODBUS_HOLDING_REGISTER 959 10 4 0 60 20 +Cooling curve climate system 2 MODBUS_HOLDING_REGISTER 966 1 1 0 9 0 +Cooling curve climate system 1 MODBUS_HOLDING_REGISTER 967 1 1 0 9 0 +Cooling offset climate system 2 MODBUS_HOLDING_REGISTER 974 1 1 -10 10 0 +Cooling offset climate system 1 MODBUS_HOLDING_REGISTER 975 1 1 -10 10 0 +Own curve, cooling P4 MODBUS_HOLDING_REGISTER 976 1 °C 1 -5 40 20 +Own curve, cooling P2 MODBUS_HOLDING_REGISTER 977 1 °C 1 -5 40 20 +Own curve, cooling P1 MODBUS_HOLDING_REGISTER 978 1 °C 1 -5 40 20 +Current transformer ratio MODBUS_HOLDING_REGISTER 980 1 5 300 3000 300 +Room sensor set point value climate system 8, cooling MODBUS_HOLDING_REGISTER 981 10 °C 2 50 350 250 +Room sensor set point value climate system 7, cooling MODBUS_HOLDING_REGISTER 982 10 °C 2 50 350 250 +Room sensor set point value climate system 6, cooling MODBUS_HOLDING_REGISTER 983 10 °C 2 50 350 250 +Room sensor set point value climate system 5, cooling MODBUS_HOLDING_REGISTER 984 10 °C 2 50 350 250 +Room sensor set point value climate system 4, cooling MODBUS_HOLDING_REGISTER 985 10 °C 2 50 350 250 +Room sensor set point value climate system 3, cooling MODBUS_HOLDING_REGISTER 986 10 °C 2 50 350 250 +Room sensor set point value climate system 2, cooling MODBUS_HOLDING_REGISTER 987 10 °C 2 50 350 250 +Room sensor set point value climate system 1, cooling MODBUS_HOLDING_REGISTER 988 10 °C 2 50 350 250 +Room sensor factor climate system 8, cooling MODBUS_HOLDING_REGISTER 989 10 4 0 60 10 +Room sensor factor climate system 7, cooling MODBUS_HOLDING_REGISTER 990 10 4 0 60 10 +Room sensor factor climate system 6, cooling MODBUS_HOLDING_REGISTER 991 10 4 0 60 10 +Room sensor factor climate system 5, cooling MODBUS_HOLDING_REGISTER 992 10 4 0 60 10 +Room sensor factor climate system 4, cooling MODBUS_HOLDING_REGISTER 993 10 4 0 60 10 +Room sensor factor climate system 3, cooling MODBUS_HOLDING_REGISTER 994 10 4 0 60 10 +Room sensor factor climate system 2, cooling MODBUS_HOLDING_REGISTER 995 10 4 0 60 10 +Room sensor factor climate system 1, cooling MODBUS_HOLDING_REGISTER 996 10 4 0 60 10 +Set point value (RH) MODBUS_HOLDING_REGISTER 997 1 % 1 30 90 60 +HTS 1 MODBUS_HOLDING_REGISTER 998 1 4 0 1 0 +Prevent condensation climate system 1 MODBUS_HOLDING_REGISTER 1006 1 1 0 1 0 +OPT MODBUS_HOLDING_REGISTER 1015 1 4 0 1 0 +DM start difference (OPT) MODBUS_HOLDING_REGISTER 1016 1 DM 2 10 2000 700 +Exhaust air fan speed 4 (ERS 1) MODBUS_HOLDING_REGISTER 1021 1 % 4 0 100 100 +Exhaust air fan speed 3 (ERS 1) MODBUS_HOLDING_REGISTER 1022 1 % 4 0 100 80 +Exhaust air fan speed 2 (ERS 1) MODBUS_HOLDING_REGISTER 1023 1 % 4 0 100 30 +Exhaust air fan speed 1 (ERS 1) MODBUS_HOLDING_REGISTER 1024 1 % 4 0 100 0 +Exhaust air fan speed normal (ERS 1) MODBUS_HOLDING_REGISTER 1025 1 % 4 1 100 75 +Thermostat (ACS) MODBUS_HOLDING_REGISTER 1026 1 4 0 1 0 +Filtering time (BT64) MODBUS_HOLDING_REGISTER 1027 1 min 4 5 30 5 +(ACS) - Thermostat, hysteresis between compressors MODBUS_HOLDING_REGISTER 1028 1 °C 1 1 10 2 +Start temperature (BT64) MODBUS_HOLDING_REGISTER 1029 1 °C 1 -8 30 10 +Temperature to transfer to borehole MODBUS_HOLDING_REGISTER 1030 1 °C 1 -8 30 0 +Bypass temp. (ERS 1) MODBUS_HOLDING_REGISTER 1044 1 °C 4 2 10 4 +Flow sensor activated X22 MODBUS_HOLDING_REGISTER 1049 1 4 0 1 0 +Max. internal additional heat SG Ready MODBUS_HOLDING_REGISTER 1052 100 kW 2 0 900 700 +Limit humidity in the room, cooling climate system 1 MODBUS_HOLDING_REGISTER 1063 1 1 0 1 0 +Hysteresis (OPT) MODBUS_HOLDING_REGISTER 1066 1 2 10 2000 100 +PV panel affects heating (EME) MODBUS_HOLDING_REGISTER 1069 1 4 0 1 0 +PV panel affects hot water (EME) MODBUS_HOLDING_REGISTER 1070 1 4 0 1 0 +Delay timer EME MODBUS_HOLDING_REGISTER 1071 1 5 0 0 0 +Low brine out alarm temperature (EP15) MODBUS_HOLDING_REGISTER 1072 10 °C 2 -120 150 -80 +Pump 4 (FLM) MODBUS_HOLDING_REGISTER 1074 1 4 0 1 0 +Pump 3 (FLM) MODBUS_HOLDING_REGISTER 1075 1 4 0 1 0 +Pump 2 (FLM) MODBUS_HOLDING_REGISTER 1076 1 4 0 1 0 +Defrosting time (FLM 4) MODBUS_HOLDING_REGISTER 1077 1 h 4 1 30 10 +Defrosting time (FLM 3) MODBUS_HOLDING_REGISTER 1078 1 h 4 1 30 10 +Defrosting time (FLM 2) MODBUS_HOLDING_REGISTER 1079 1 h 4 1 30 10 +Cooling (FLM 4) MODBUS_HOLDING_REGISTER 1080 1 4 0 1 0 +Cooling (FLM 3) MODBUS_HOLDING_REGISTER 1081 1 4 0 1 0 +Cooling (FLM 2) MODBUS_HOLDING_REGISTER 1082 1 4 0 1 0 +Pump speed (FLM 4) MODBUS_HOLDING_REGISTER 1083 1 % 4 1 100 100 +Pump speed (FLM 3) MODBUS_HOLDING_REGISTER 1084 1 % 4 1 100 100 +Pump speed (FLM 2) MODBUS_HOLDING_REGISTER 1085 1 % 4 1 100 100 +Pump speed (FLM 1) MODBUS_HOLDING_REGISTER 1086 1 % 4 1 100 100 +Excess temperature (FLM 4) MODBUS_HOLDING_REGISTER 1087 10 °C 4 10 100 30 +Excess temperature (FLM 3) MODBUS_HOLDING_REGISTER 1088 10 °C 4 10 100 30 +Excess temperature (FLM 2) MODBUS_HOLDING_REGISTER 1089 10 °C 4 10 100 30 +Excess temperature (FLM 1) MODBUS_HOLDING_REGISTER 1090 10 °C 4 10 100 30 +Set point value, cooling (FLM 4) MODBUS_HOLDING_REGISTER 1091 10 °C 2 50 400 210 +Set point value, cooling (FLM 3) MODBUS_HOLDING_REGISTER 1092 10 °C 2 50 400 210 +Set point value, cooling (FLM 2) MODBUS_HOLDING_REGISTER 1093 10 °C 2 50 400 210 +Set point value, cooling (FLM 1) MODBUS_HOLDING_REGISTER 1094 10 °C 2 50 400 210 +AUX blocking (OPT) MODBUS_HOLDING_REGISTER 1095 1 4 0 0 0 +Outdoor air mixing MODBUS_HOLDING_REGISTER 1096 1 4 0 1 0 +Smart home room control MODBUS_HOLDING_REGISTER 1102 1 4 0 1 0 +Speed, brine pump, standby mode (EP14) MODBUS_HOLDING_REGISTER 1103 1 % 4 0 100 30 +Smart Energy Source MODBUS_HOLDING_REGISTER 1105 1 4 0 1 0 +Control method, smart energy source MODBUS_HOLDING_REGISTER 1106 1 4 0 1 0 +El. price, special, smart energy source MODBUS_HOLDING_REGISTER 1107 1 4 0 2 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1108 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1109 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1110 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1111 1 4 0 3 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1112 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1113 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1114 1 5 0 10000 100 +El. price, smart energy source MODBUS_HOLDING_REGISTER 1115 1 4 0 1 0 +El. price, fixed, smart energy source MODBUS_HOLDING_REGISTER 1116 1 5 0 10000 100 +Prim. factor, smart energy source MODBUS_HOLDING_REGISTER 1117 10 4 0 50 25 +Prim. factor, shunt add. heat smart energy source MODBUS_HOLDING_REGISTER 1118 10 4 0 50 10 +Prim. factor, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1119 10 4 0 50 10 +Prim. factor, OPT10 smart energy source MODBUS_HOLDING_REGISTER 1120 10 4 0 50 10 +OPT10, high tariff price smart energy source MODBUS_HOLDING_REGISTER 1121 1 5 1 10000 100 +OPT10, low tariff price smart energy source MODBUS_HOLDING_REGISTER 1122 1 5 1 10000 100 +ext. step add. heat, high tariff price smart energy source MODBUS_HOLDING_REGISTER 1123 1 5 1 10000 100 +ext. step add. heat, low tariff price smart energy source MODBUS_HOLDING_REGISTER 1124 1 5 1 10000 100 +Shunt add. heat, high tariff price smart energy source MODBUS_HOLDING_REGISTER 1125 1 5 1 10000 100 +Shunt add. heat, low tariff price smart energy source MODBUS_HOLDING_REGISTER 1126 1 5 1 10000 100 +El. price, fixed, high tariff smart energy source MODBUS_HOLDING_REGISTER 1127 1 5 1 10000 100 +El. price, fixed, low tariff smart energy source MODBUS_HOLDING_REGISTER 1128 1 5 1 10000 100 +El. price, variable, high tariff smart energy source MODBUS_HOLDING_REGISTER 1129 1 5 1 10000 100 +El. price, variable, low tariff smart energy source MODBUS_HOLDING_REGISTER 1130 1 5 1 10000 100 +DM start source, priority 5 smart energy source MODBUS_HOLDING_REGISTER 1131 1 2 100 2000 400 +DM start source, priority 4 smart energy source MODBUS_HOLDING_REGISTER 1132 1 2 100 2000 400 +DM start source, priority 3 smart energy source MODBUS_HOLDING_REGISTER 1133 1 2 100 2000 400 +DM start source, priority 2 smart energy source MODBUS_HOLDING_REGISTER 1134 1 2 100 2000 400 +DM start source, priority 1 smart energy source MODBUS_HOLDING_REGISTER 1135 1 2 -2000 -10 -60 +Start day, tariff smart energy source MODBUS_HOLDING_REGISTER 1136 1 4 1 31 1 +End day, tariff smart energy source MODBUS_HOLDING_REGISTER 1137 1 4 1 31 31 +Start month, tariff smart energy source MODBUS_HOLDING_REGISTER 1138 1 4 1 12 1 +End month, tariff smart energy source MODBUS_HOLDING_REGISTER 1139 1 4 1 12 12 +Start day, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1172 1 4 1 31 1 +End day, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1173 1 4 1 31 31 +Start month, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1174 1 4 1 12 1 +End month, fixed tariff smart energy source MODBUS_HOLDING_REGISTER 1175 1 4 1 12 12 +Start day, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1208 1 4 1 31 1 +End day, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1209 1 4 1 31 31 +Start month, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1210 1 4 1 12 1 +End month, tariff OPT10 smart energy source MODBUS_HOLDING_REGISTER 1211 1 4 1 12 12 +Start day tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1244 1 4 1 31 1 +End day tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1245 1 4 1 31 31 +Start month tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1246 1 4 1 12 1 +End month tariff, shunt additional heat smart energy source MODBUS_HOLDING_REGISTER 1247 1 4 1 12 12 +Start day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1280 1 4 1 31 1 +End day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1281 1 4 1 31 31 +Start month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1282 1 4 1 12 1 +End month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1283 1 4 1 12 12 +Ground water pump temperature alarm MODBUS_HOLDING_REGISTER 1316 1 4 0 1 0 +Ground water pump temperature alarm level MODBUS_HOLDING_REGISTER 1317 1 °C 1 -15 20 3 +Constant delta T, brine pump MODBUS_HOLDING_REGISTER 1318 1 °C 4 2 10 4 +Brine pump auto mode MODBUS_HOLDING_REGISTER 1319 1 1 0 2 1 +Max difference, SES priority 1 energy source MODBUS_HOLDING_REGISTER 1326 10 °C 2 10 250 100 +Max difference, SES lower priority energy source MODBUS_HOLDING_REGISTER 1327 10 °C 2 10 250 70 +Delta brine pump passive cooling MODBUS_HOLDING_REGISTER 1328 1 °C 4 1 15 4 +Installed (EB101) MODBUS_HOLDING_REGISTER 1550 1 4 0 1 0 +EME20 MODBUS_HOLDING_REGISTER 4000 1 4 0 1 0 +Current power MODBUS_INPUT_REGISTER 2176 1 W 6 0 0 0 +Speed of circulation pump passive cooling (EP15) MODBUS_HOLDING_REGISTER 4006 1 % 4 1 100 70 +Speed of circulation pump active cooling (EP15) MODBUS_HOLDING_REGISTER 4007 1 % 4 1 100 70 +Ground water pump's control signal MODBUS_HOLDING_REGISTER 4012 1 1 0 0 0 +BT12 offset MODBUS_HOLDING_REGISTER 4014 10 °C 1 -50 50 0 +Total average power (EME 20) MODBUS_INPUT_REGISTER 2178 100 kW 6 0 0 0 +Total energy MODBUS_INPUT_REGISTER 2180 10 kWh 3 0 0 0 +ERS 2 MODBUS_HOLDING_REGISTER 4076 1 4 0 1 0 +ERS 3 MODBUS_HOLDING_REGISTER 4077 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 4078 1 4 0 1 0 +id:6486 MODBUS_HOLDING_REGISTER 4135 1 4 0 1 0 +id:6756 MODBUS_INPUT_REGISTER 2004 10 %RH 2 0 0 0 +id:6757 MODBUS_INPUT_REGISTER 2005 10 %RH 2 0 0 0 +id:6758 MODBUS_INPUT_REGISTER 2006 10 %RH 2 0 0 0 +HTS 2 MODBUS_HOLDING_REGISTER 1981 1 4 0 1 0 +HTS 3 MODBUS_HOLDING_REGISTER 1982 1 4 0 1 0 +HTS 4 MODBUS_HOLDING_REGISTER 1983 1 4 0 1 0 +External adjustment, cooling climate system 8 MODBUS_HOLDING_REGISTER 4138 1 1 -10 10 0 +External adjustment, cooling climate system 7 MODBUS_HOLDING_REGISTER 4139 1 1 -10 10 0 +External adjustment, cooling climate system 6 MODBUS_HOLDING_REGISTER 4140 1 1 -10 10 0 +External adjustment, cooling climate system 5 MODBUS_HOLDING_REGISTER 4141 1 1 -10 10 0 +External adjustment, cooling climate system 4 MODBUS_HOLDING_REGISTER 4142 1 1 -10 10 0 +External adjustment, cooling climate system 3 MODBUS_HOLDING_REGISTER 4143 1 1 -10 10 0 +External adjustment, cooling climate system 2 MODBUS_HOLDING_REGISTER 4144 1 1 -10 10 0 +External adjustment, cooling climate system 1 MODBUS_HOLDING_REGISTER 4145 1 1 -10 10 0 +External adjustment with room sensor, cooling climate system 8 MODBUS_HOLDING_REGISTER 4146 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 7 MODBUS_HOLDING_REGISTER 4147 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 6 MODBUS_HOLDING_REGISTER 4148 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 5 MODBUS_HOLDING_REGISTER 4149 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 4 MODBUS_HOLDING_REGISTER 4150 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 3 MODBUS_HOLDING_REGISTER 4151 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 2 MODBUS_HOLDING_REGISTER 4152 10 °C 2 50 300 200 +External adjustment with room sensor, cooling climate system 1 MODBUS_HOLDING_REGISTER 4153 10 °C 2 50 300 200 +Current power MODBUS_INPUT_REGISTER 2727 100 kW 6 0 0 0 +id:6917 MODBUS_HOLDING_REGISTER 4072 1 4 0 200 1 +id:6918 MODBUS_HOLDING_REGISTER 4073 1 4 0 20 1 +id:6920 MODBUS_HOLDING_REGISTER 4074 1 4 0 20 0 +id:6921 MODBUS_HOLDING_REGISTER 4075 1 4 1 100 15 +id:6922 MODBUS_HOLDING_REGISTER 4154 1 4 0 20 3 +id:6923 MODBUS_HOLDING_REGISTER 4155 1 4 0 20 2 +blockFreq 1 (EB102) MODBUS_HOLDING_REGISTER 4164 1 4 0 1 0 +blockFreq 1 (EB103) MODBUS_HOLDING_REGISTER 4165 1 4 0 1 0 +blockFreq 1 (EB104) MODBUS_HOLDING_REGISTER 4166 1 4 0 1 0 +blockFreq 1 (EB105) MODBUS_HOLDING_REGISTER 4167 1 4 0 1 0 +blockFreq 1 (EB106) MODBUS_HOLDING_REGISTER 4168 1 4 0 1 0 +blockFreq 1 (EB107) MODBUS_HOLDING_REGISTER 4169 1 4 0 1 0 +blockFreq 1 (EB108) MODBUS_HOLDING_REGISTER 4170 1 4 0 1 0 +id:6977 MODBUS_HOLDING_REGISTER 4201 1 4 0 100 0 +Power at DOT, manual value MODBUS_HOLDING_REGISTER 4200 1 4 0 1 0 +Hi press (BP9) MODBUS_INPUT_REGISTER 2132 100 bar 2 0 0 0 +Blocking actions (ERS 3) MODBUS_HOLDING_REGISTER 4100 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 4101 1 4 0 2 2 +Evaporator (BT84) MODBUS_INPUT_REGISTER 2129 10 °C 2 0 0 0 +id:7048 MODBUS_HOLDING_REGISTER 5227 1 4 0 1 0 +id:7122 MODBUS_INPUT_REGISTER 2401 10 V 1 0 0 0 +id:7123 MODBUS_INPUT_REGISTER 2402 10 V 1 0 0 0 +id:7124 MODBUS_INPUT_REGISTER 2403 10 V 1 0 0 0 +id:7125 MODBUS_INPUT_REGISTER 2404 10 V 1 0 0 0 +id:7126 MODBUS_INPUT_REGISTER 2405 10 V 1 0 0 0 +id:7127 MODBUS_INPUT_REGISTER 2406 10 V 1 0 0 0 +id:7128 MODBUS_INPUT_REGISTER 2407 10 V 1 0 0 0 +id:7130 MODBUS_HOLDING_REGISTER 5433 1 4 0 1 0 +id:7138 MODBUS_HOLDING_REGISTER 5441 1 % 4 0 100 70 +id:7139 MODBUS_HOLDING_REGISTER 5442 1 4 0 1 0 +id:7140 MODBUS_HOLDING_REGISTER 5443 1 4 0 1 0 +id:7141 MODBUS_HOLDING_REGISTER 5444 1 % 4 0 100 70 +id:7142 MODBUS_HOLDING_REGISTER 5445 1 4 0 1 0 +id:7143 MODBUS_HOLDING_REGISTER 5446 1 4 0 1 0 +id:7144 MODBUS_HOLDING_REGISTER 5447 1 % 4 0 100 70 +id:7145 MODBUS_HOLDING_REGISTER 5448 1 4 0 1 0 +id:7146 MODBUS_HOLDING_REGISTER 5449 1 4 0 1 0 +id:7147 MODBUS_HOLDING_REGISTER 5450 1 % 4 0 100 70 +id:7148 MODBUS_HOLDING_REGISTER 5451 1 4 0 1 0 +id:7149 MODBUS_HOLDING_REGISTER 5452 1 4 0 1 0 +id:7150 MODBUS_HOLDING_REGISTER 5453 1 % 4 0 100 70 +EB103/104-GP12 MODBUS_HOLDING_REGISTER 5454 1 4 0 1 0 +id:7176 MODBUS_HOLDING_REGISTER 5455 1 4 0 1 0 +id:7943 MODBUS_INPUT_REGISTER 2399 10 % 5 0 0 0 +id:7944 MODBUS_INPUT_REGISTER 2400 10 % 5 0 0 0 +id:8002 MODBUS_HOLDING_REGISTER 1996 1 % 1 -15 10 -3 +id:8003 MODBUS_HOLDING_REGISTER 1997 1 % 4 1 254 65 +Minimum permitted speed (EB100 GP1) MODBUS_HOLDING_REGISTER 5351 1 % 4 1 50 1 +High pressure (BP9 dew) MODBUS_INPUT_REGISTER 2126 10 °C 2 0 0 0 +Low pressure (BP8 dew) MODBUS_INPUT_REGISTER 2127 10 °C 2 0 0 0 +System 1 (RMU) MODBUS_HOLDING_REGISTER 176 1 4 0 1 0 +System 2 (RMU) MODBUS_HOLDING_REGISTER 177 1 4 0 1 0 +System 3 (RMU) MODBUS_HOLDING_REGISTER 178 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 179 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 1998 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 1999 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 2000 1 4 0 1 0 +System 4 (RMU) MODBUS_HOLDING_REGISTER 2001 1 4 0 1 0 +id:8302 MODBUS_HOLDING_REGISTER 5388 1 4 0 1 0 +id:8982 MODBUS_HOLDING_REGISTER 5390 1 4 0 0 0 +The start guide has been run MODBUS_HOLDING_REGISTER 2742 1 4 0 1 1 +Audio signal on alarm MODBUS_HOLDING_REGISTER 5326 1 4 0 1 1 +Sound when pressing button MODBUS_HOLDING_REGISTER 5327 1 4 0 1 1 +ERS S40 7 MODBUS_HOLDING_REGISTER 3057 1 4 0 1 0 +Alarm room sens cool oper MODBUS_HOLDING_REGISTER 3031 1 4 0 1 0 +Heating, auto MODBUS_HOLDING_REGISTER 3059 1 4 0 1 1 +Factor MODBUS_HOLDING_REGISTER 3033 1 4 1 10 5 +id:10881 MODBUS_HOLDING_REGISTER 3062 1 4 0 1 0 +id:10890 MODBUS_HOLDING_REGISTER 3063 1 4 0 1 0 +id:12332 MODBUS_HOLDING_REGISTER 2767 1 2 -32768 32767 -32768 +id:12333 MODBUS_HOLDING_REGISTER 2768 1 2 -32768 32767 -32768 +id:12334 MODBUS_HOLDING_REGISTER 2769 1 2 -32768 32767 -32768 +id:12335 MODBUS_HOLDING_REGISTER 2770 1 2 -32768 32767 -32768 +id:12336 MODBUS_HOLDING_REGISTER 2771 1 2 -32768 32767 -32768 +id:12337 MODBUS_HOLDING_REGISTER 2772 1 2 -32768 32767 -32768 +id:12338 MODBUS_HOLDING_REGISTER 2773 1 2 -32768 32767 -32768 +id:12339 MODBUS_HOLDING_REGISTER 2774 1 2 -32768 32767 -32768 +id:12340 MODBUS_HOLDING_REGISTER 2775 1 2 -32768 32767 -32768 +id:12341 MODBUS_HOLDING_REGISTER 2776 1 2 -32768 32767 -32768 +id:12342 MODBUS_HOLDING_REGISTER 2777 1 2 -32768 32767 -32768 +id:12343 MODBUS_HOLDING_REGISTER 2778 1 2 -32768 32767 -32768 +id:12344 MODBUS_HOLDING_REGISTER 2779 1 2 -32768 32767 -32768 +id:12345 MODBUS_HOLDING_REGISTER 2780 1 2 -32768 32767 -32768 +id:12346 MODBUS_HOLDING_REGISTER 2781 1 2 -32768 32767 -32768 +id:12347 MODBUS_HOLDING_REGISTER 2782 1 2 -32768 32767 -32768 +id:12348 MODBUS_HOLDING_REGISTER 2783 1 2 -32768 32767 -32768 +id:12349 MODBUS_HOLDING_REGISTER 2784 1 2 -32768 32767 -32768 +id:12350 MODBUS_HOLDING_REGISTER 2785 1 2 -32768 32767 -32768 +id:12351 MODBUS_HOLDING_REGISTER 2786 1 2 -32768 32767 -32768 +id:12352 MODBUS_HOLDING_REGISTER 2787 1 2 -32768 32767 -32768 +id:12353 MODBUS_HOLDING_REGISTER 2788 1 2 -32768 32767 -32768 +id:12354 MODBUS_HOLDING_REGISTER 2789 1 2 -32768 32767 -32768 +id:12355 MODBUS_HOLDING_REGISTER 2790 1 2 -32768 32767 -32768 +id:12356 MODBUS_HOLDING_REGISTER 2791 1 2 -32768 32767 -32768 +id:12357 MODBUS_HOLDING_REGISTER 2792 1 2 -32768 32767 -32768 +id:12358 MODBUS_HOLDING_REGISTER 2793 1 2 -32768 32767 -32768 +id:12359 MODBUS_HOLDING_REGISTER 2794 1 2 -32768 32767 -32768 +id:12360 MODBUS_HOLDING_REGISTER 2795 1 2 -32768 32767 -32768 +id:12361 MODBUS_HOLDING_REGISTER 2796 1 2 -32768 32767 -32768 +id:12362 MODBUS_HOLDING_REGISTER 2797 1 2 -32768 32767 -32768 +id:12363 MODBUS_HOLDING_REGISTER 2798 1 2 -32768 32767 -32768 +id:12364 MODBUS_HOLDING_REGISTER 2799 1 2 -32768 32767 -32768 +id:12365 MODBUS_HOLDING_REGISTER 2800 1 2 -32768 32767 -32768 +id:12366 MODBUS_HOLDING_REGISTER 2801 1 2 -32768 32767 -32768 +id:12367 MODBUS_HOLDING_REGISTER 2802 1 2 -32768 32767 -32768 +id:12368 MODBUS_HOLDING_REGISTER 2803 1 2 -32768 32767 -32768 +id:12369 MODBUS_HOLDING_REGISTER 2804 1 2 -32768 32767 -32768 +id:12370 MODBUS_HOLDING_REGISTER 2805 1 2 -32768 32767 -32768 +id:12371 MODBUS_HOLDING_REGISTER 2806 1 2 -32768 32767 -32768 +id:12372 MODBUS_HOLDING_REGISTER 2807 1 2 -32768 32767 -32768 +id:12373 MODBUS_HOLDING_REGISTER 2808 1 2 -32768 32767 -32768 +id:12374 MODBUS_HOLDING_REGISTER 2809 1 2 -32768 32767 -32768 +id:12375 MODBUS_HOLDING_REGISTER 2810 1 2 -32768 32767 -32768 +id:12376 MODBUS_HOLDING_REGISTER 2811 1 2 -32768 32767 -32768 +id:12377 MODBUS_HOLDING_REGISTER 2812 1 2 -32768 32767 -32768 +id:12378 MODBUS_HOLDING_REGISTER 2813 1 2 -32768 32767 -32768 +id:12379 MODBUS_HOLDING_REGISTER 2814 1 2 -32768 32767 -32768 +id:12380 MODBUS_HOLDING_REGISTER 2815 1 2 -32768 32767 -32768 +id:12381 MODBUS_HOLDING_REGISTER 2816 1 2 -32768 32767 -32768 +id:12382 MODBUS_HOLDING_REGISTER 2817 1 2 -32768 32767 -32768 +id:12383 MODBUS_HOLDING_REGISTER 2818 1 2 -32768 32767 -32768 +id:12384 MODBUS_HOLDING_REGISTER 2819 1 2 -32768 32767 -32768 +Period MODBUS_HOLDING_REGISTER 3088 1 4 0 1 0 +Number of years MODBUS_HOLDING_REGISTER 3089 1 4 1 10 1 +Months MODBUS_HOLDING_REGISTER 3090 1 6 0 4095 4095 +id:12388 MODBUS_HOLDING_REGISTER 5307 1 4 0 0 0 +Active days MODBUS_HOLDING_REGISTER 3066 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3067 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3068 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3069 1 4 0 127 0 +Active days MODBUS_HOLDING_REGISTER 3070 1 4 0 127 0 +Start time MODBUS_HOLDING_REGISTER 5393 1 - - - - +Start time MODBUS_HOLDING_REGISTER 5397 1 - - - - +Stop time MODBUS_HOLDING_REGISTER 5401 1 - - - - +Allow add. heat during defrosting MODBUS_HOLDING_REGISTER 2766 1 4 0 1 0 +K4 relay is Normally Closed MODBUS_HOLDING_REGISTER 2764 1 4 0 1 0 +id:12504 MODBUS_HOLDING_REGISTER 2854 1 5 0 600 504 +id:12505 MODBUS_HOLDING_REGISTER 2855 1 5 0 600 24 +id:12506 MODBUS_HOLDING_REGISTER 2856 10 4 0 100 14 +id:12507 MODBUS_HOLDING_REGISTER 2895 1 s 5 0 600 40 +id:12508 MODBUS_HOLDING_REGISTER 2896 1 4 0 20 5 +id:12509 MODBUS_HOLDING_REGISTER 2897 1 4 0 10 1 +id:12510 MODBUS_HOLDING_REGISTER 2898 1 °C 1 -50 50 -8 +id:12511 MODBUS_HOLDING_REGISTER 2899 1 s 4 0 180 90 +id:12522 MODBUS_HOLDING_REGISTER 2909 1 °C 1 -50 50 20 +id:12523 MODBUS_HOLDING_REGISTER 2910 1 °C 4 0 150 108 +id:12524 MODBUS_HOLDING_REGISTER 2911 1 °C 4 0 150 108 +id:12525 MODBUS_HOLDING_REGISTER 2912 1 s 5 0 600 60 +id:12526 MODBUS_HOLDING_REGISTER 2913 1 °C 5 50 150 100 +id:12527 MODBUS_HOLDING_REGISTER 2914 1 4 0 50 6 +id:12528 MODBUS_HOLDING_REGISTER 2919 1 s 5 0 600 60 +id:12529 MODBUS_HOLDING_REGISTER 2920 1 °C 4 50 150 70 +id:12530 MODBUS_HOLDING_REGISTER 2853 1 4 0 10 1 +id:12531 MODBUS_HOLDING_REGISTER 2852 1 4 0 10 1 +id:12532 MODBUS_HOLDING_REGISTER 2846 10 5 0 100 22 +id:12533 MODBUS_HOLDING_REGISTER 2847 10 4 0 100 20 +id:12534 MODBUS_HOLDING_REGISTER 2848 10 5 0 100 20 +id:12535 MODBUS_HOLDING_REGISTER 2849 10 4 0 100 20 +id:12536 MODBUS_HOLDING_REGISTER 2850 10 4 0 100 10 +id:12537 MODBUS_HOLDING_REGISTER 2851 10 4 0 100 5 +id:12538 MODBUS_HOLDING_REGISTER 2925 1 5 0 500 55 +id:12539 MODBUS_HOLDING_REGISTER 2926 1 5 0 500 480 +id:12540 MODBUS_HOLDING_REGISTER 2870 10 4 0 100 30 +id:12541 MODBUS_HOLDING_REGISTER 2871 10 4 0 100 20 +id:12542 MODBUS_HOLDING_REGISTER 2872 10 4 0 100 10 +id:12543 MODBUS_HOLDING_REGISTER 2873 10 4 0 100 5 +id:12544 MODBUS_HOLDING_REGISTER 2874 10 4 0 100 10 +id:12545 MODBUS_HOLDING_REGISTER 2875 10 4 0 100 10 +id:12546 MODBUS_HOLDING_REGISTER 2915 10 5 0 5000 200 +id:12547 MODBUS_HOLDING_REGISTER 2840 10 5 0 5000 240 +id:12548 MODBUS_HOLDING_REGISTER 2841 10 5 0 5000 240 +id:12549 MODBUS_HOLDING_REGISTER 2842 100 5 0 1000 2 +id:12550 MODBUS_HOLDING_REGISTER 2843 100 5 0 1000 2 +id:12551 MODBUS_HOLDING_REGISTER 2844 100 5 0 1000 4 +id:12552 MODBUS_HOLDING_REGISTER 2845 100 5 0 1000 3 +id:12553 MODBUS_HOLDING_REGISTER 2916 100 5 0 5000 100 +id:12554 MODBUS_HOLDING_REGISTER 2917 100 5 0 5000 300 +id:12555 MODBUS_HOLDING_REGISTER 2918 10 4 0 100 20 +id:12556 MODBUS_HOLDING_REGISTER 2890 1 2 0 500 60 +id:12557 MODBUS_HOLDING_REGISTER 2891 1 2 0 500 40 +id:12558 MODBUS_HOLDING_REGISTER 2892 1 2 0 500 20 +id:12559 MODBUS_HOLDING_REGISTER 2894 1 2 0 500 20 +id:12560 MODBUS_HOLDING_REGISTER 2927 1 2 0 500 40 +id:12561 MODBUS_HOLDING_REGISTER 2928 1 s 4 0 100 20 +id:12562 MODBUS_HOLDING_REGISTER 2929 1 s 5 0 10000 1200 +id:12563 MODBUS_HOLDING_REGISTER 2930 1 s 5 0 10000 1200 +id:12564 MODBUS_HOLDING_REGISTER 2931 1 s 5 0 10000 420 +id:12565 MODBUS_HOLDING_REGISTER 2932 1 4 0 100 8 +id:12566 MODBUS_HOLDING_REGISTER 2933 1 4 0 100 6 +id:12567 MODBUS_HOLDING_REGISTER 2885 1 s 5 0 1000 100 +id:12568 MODBUS_HOLDING_REGISTER 2886 1 s 5 0 1000 200 +id:12569 MODBUS_HOLDING_REGISTER 2887 1 s 5 0 1000 300 +id:12570 MODBUS_HOLDING_REGISTER 2888 1 s 5 0 1000 200 +id:12571 MODBUS_HOLDING_REGISTER 2889 1 s 5 0 1000 100 +id:12572 MODBUS_HOLDING_REGISTER 2861 1 s 5 0 10000 600 +id:12573 MODBUS_HOLDING_REGISTER 2862 1 s 5 0 10000 600 +id:12574 MODBUS_HOLDING_REGISTER 2863 1 s 5 0 10000 200 +id:12575 MODBUS_HOLDING_REGISTER 2864 1 s 5 0 10000 200 +id:12576 MODBUS_HOLDING_REGISTER 2865 1 s 5 0 10000 200 +id:12577 MODBUS_HOLDING_REGISTER 2866 1 s 5 0 10000 200 +id:12578 MODBUS_HOLDING_REGISTER 2867 1 s 5 0 10000 200 +id:12579 MODBUS_HOLDING_REGISTER 2868 1 s 5 0 10000 1500 +id:12580 MODBUS_HOLDING_REGISTER 2869 1 s 5 0 10000 1500 +id:12581 MODBUS_HOLDING_REGISTER 2934 1 s 4 0 50 30 +id:12582 MODBUS_HOLDING_REGISTER 2935 1 4 1 50 10 +id:12583 MODBUS_HOLDING_REGISTER 2936 1 s 4 3 30 10 +id:12584 MODBUS_HOLDING_REGISTER 2937 100 2 0 100 5 +id:12585 MODBUS_HOLDING_REGISTER 2938 1 5 0 255 32 +id:12586 MODBUS_HOLDING_REGISTER 2939 1 s 5 0 20 3 +id:12587 MODBUS_HOLDING_REGISTER 2940 1 s 5 0 20 3 +id:12588 MODBUS_HOLDING_REGISTER 2941 1 s 5 0 20 3 +id:12650 MODBUS_HOLDING_REGISTER 3104 1 - - - - +id:12651 MODBUS_HOLDING_REGISTER 3144 1 - - - - +id:12652 MODBUS_HOLDING_REGISTER 3184 1 - - - - +id:12653 MODBUS_HOLDING_REGISTER 3224 1 - - - - +id:12654 MODBUS_HOLDING_REGISTER 3264 1 - - - - +id:12655 MODBUS_HOLDING_REGISTER 3304 1 - - - - +id:12656 MODBUS_HOLDING_REGISTER 3344 1 - - - - +id:12657 MODBUS_HOLDING_REGISTER 3384 1 - - - - +id:12658 MODBUS_HOLDING_REGISTER 3424 1 - - - - +id:12659 MODBUS_HOLDING_REGISTER 3464 1 - - - - +id:12660 MODBUS_HOLDING_REGISTER 3504 1 - - - - +id:12661 MODBUS_HOLDING_REGISTER 3544 1 - - - - +id:12662 MODBUS_HOLDING_REGISTER 3584 1 - - - - +id:12663 MODBUS_HOLDING_REGISTER 3624 1 - - - - +id:12664 MODBUS_HOLDING_REGISTER 3664 1 - - - - +id:12665 MODBUS_HOLDING_REGISTER 3704 1 - - - - +id:12666 MODBUS_HOLDING_REGISTER 3744 1 - - - - +id:12667 MODBUS_HOLDING_REGISTER 3784 1 - - - - +id:12668 MODBUS_HOLDING_REGISTER 3824 1 - - - - +id:12669 MODBUS_HOLDING_REGISTER 3864 1 - - - - +id:12670 MODBUS_HOLDING_REGISTER 3904 1 - - - - +id:12671 MODBUS_HOLDING_REGISTER 2978 1 4 0 3 0 +id:12672 MODBUS_HOLDING_REGISTER 2979 1 4 0 3 0 +id:12673 MODBUS_HOLDING_REGISTER 2980 1 4 0 3 0 +id:12674 MODBUS_HOLDING_REGISTER 2981 1 4 0 3 0 +id:12675 MODBUS_HOLDING_REGISTER 2982 1 4 0 3 0 +id:12676 MODBUS_HOLDING_REGISTER 2983 1 4 0 3 0 +id:12677 MODBUS_HOLDING_REGISTER 2984 1 4 0 3 0 +id:12678 MODBUS_HOLDING_REGISTER 2985 1 4 0 3 0 +id:12679 MODBUS_HOLDING_REGISTER 2986 1 4 0 15 0 +id:12680 MODBUS_HOLDING_REGISTER 2987 1 4 0 15 0 +id:12681 MODBUS_HOLDING_REGISTER 2988 1 4 0 15 0 +id:12682 MODBUS_HOLDING_REGISTER 2989 1 4 0 15 0 +id:12683 MODBUS_HOLDING_REGISTER 2990 1 4 0 15 0 +id:12684 MODBUS_HOLDING_REGISTER 2991 1 4 0 15 0 +id:12685 MODBUS_HOLDING_REGISTER 2992 1 4 0 15 0 +id:12686 MODBUS_HOLDING_REGISTER 2993 1 4 0 15 0 +id:12687 MODBUS_HOLDING_REGISTER 2994 1 4 0 15 0 +id:12688 MODBUS_HOLDING_REGISTER 2995 1 4 0 15 0 +id:12689 MODBUS_HOLDING_REGISTER 2996 1 4 0 15 0 +id:12690 MODBUS_HOLDING_REGISTER 2997 1 4 0 15 0 +id:12691 MODBUS_HOLDING_REGISTER 2998 1 4 0 3 0 +id:12692 MODBUS_HOLDING_REGISTER 3944 1 6 0 0 0 +id:12693 MODBUS_HOLDING_REGISTER 3946 1 6 0 0 0 +id:12694 MODBUS_HOLDING_REGISTER 3948 1 6 0 0 0 +id:12695 MODBUS_HOLDING_REGISTER 3950 1 6 0 0 0 +id:12696 MODBUS_HOLDING_REGISTER 3952 1 6 0 0 0 +id:12697 MODBUS_HOLDING_REGISTER 3954 1 6 0 0 0 +id:12698 MODBUS_HOLDING_REGISTER 3956 1 6 0 0 0 +id:12699 MODBUS_HOLDING_REGISTER 3958 1 6 0 0 0 +id:12700 MODBUS_HOLDING_REGISTER 3960 1 6 0 0 0 +id:12701 MODBUS_HOLDING_REGISTER 3962 1 6 0 0 0 +id:12702 MODBUS_HOLDING_REGISTER 3964 1 6 0 0 0 +id:12703 MODBUS_HOLDING_REGISTER 3966 1 6 0 0 0 +id:12704 MODBUS_HOLDING_REGISTER 3968 1 6 0 0 0 +id:12705 MODBUS_HOLDING_REGISTER 3970 1 6 0 0 0 +id:12706 MODBUS_HOLDING_REGISTER 3972 1 6 0 0 0 +id:12707 MODBUS_HOLDING_REGISTER 3974 1 6 0 0 0 +id:12708 MODBUS_HOLDING_REGISTER 3976 1 6 0 0 0 +id:12709 MODBUS_HOLDING_REGISTER 3978 1 6 0 0 0 +id:12710 MODBUS_HOLDING_REGISTER 3980 1 6 0 0 0 +id:12711 MODBUS_HOLDING_REGISTER 3982 1 6 0 0 0 +id:12712 MODBUS_HOLDING_REGISTER 3984 1 6 0 0 0 +id:12801 MODBUS_HOLDING_REGISTER 2505 10 °C 3 50 350 200 +id:12802 MODBUS_HOLDING_REGISTER 2507 10 °C 3 50 350 200 +id:12803 MODBUS_HOLDING_REGISTER 2509 10 °C 3 50 350 200 +id:12804 MODBUS_HOLDING_REGISTER 2511 10 °C 3 50 350 200 +id:12805 MODBUS_HOLDING_REGISTER 2513 10 °C 3 50 350 200 +id:12806 MODBUS_HOLDING_REGISTER 2515 10 °C 3 50 350 200 +id:12807 MODBUS_HOLDING_REGISTER 2517 10 °C 3 50 350 200 +id:12808 MODBUS_HOLDING_REGISTER 2519 10 °C 3 50 350 200 +id:12809 MODBUS_HOLDING_REGISTER 2521 10 °C 3 50 350 200 +id:12810 MODBUS_HOLDING_REGISTER 2523 10 °C 3 50 350 200 +id:12811 MODBUS_HOLDING_REGISTER 2525 10 °C 3 50 350 200 +id:12812 MODBUS_HOLDING_REGISTER 2527 10 °C 3 50 350 200 +id:12813 MODBUS_HOLDING_REGISTER 2529 10 °C 3 50 350 200 +id:12814 MODBUS_HOLDING_REGISTER 2531 10 °C 3 50 350 200 +id:12815 MODBUS_HOLDING_REGISTER 2533 10 °C 3 50 350 200 +id:12816 MODBUS_HOLDING_REGISTER 2535 10 °C 3 50 350 200 +id:12817 MODBUS_HOLDING_REGISTER 2537 10 °C 3 50 350 200 +id:12818 MODBUS_HOLDING_REGISTER 2539 10 °C 3 50 350 200 +id:12819 MODBUS_HOLDING_REGISTER 2541 10 °C 3 50 350 200 +id:12820 MODBUS_HOLDING_REGISTER 2543 10 °C 3 50 350 200 +id:12821 MODBUS_HOLDING_REGISTER 2545 10 °C 3 50 350 200 +id:12822 MODBUS_HOLDING_REGISTER 2547 10 °C 3 50 350 200 +id:12823 MODBUS_HOLDING_REGISTER 2549 10 °C 3 50 350 200 +id:12824 MODBUS_HOLDING_REGISTER 2551 10 °C 3 50 350 200 +id:12825 MODBUS_HOLDING_REGISTER 2553 10 °C 3 50 350 200 +id:12826 MODBUS_HOLDING_REGISTER 2555 10 °C 3 50 350 200 +id:12827 MODBUS_HOLDING_REGISTER 2557 10 °C 3 50 350 200 +id:12828 MODBUS_HOLDING_REGISTER 2559 10 °C 3 50 350 200 +id:12829 MODBUS_HOLDING_REGISTER 2561 10 °C 3 50 350 200 +id:12830 MODBUS_HOLDING_REGISTER 2563 10 °C 3 50 350 200 +id:12831 MODBUS_HOLDING_REGISTER 2565 10 °C 3 50 350 200 +id:12832 MODBUS_HOLDING_REGISTER 2567 10 °C 3 50 350 200 +id:12833 MODBUS_HOLDING_REGISTER 2569 10 °C 3 50 350 200 +id:12834 MODBUS_HOLDING_REGISTER 2571 10 °C 3 50 350 200 +id:12835 MODBUS_HOLDING_REGISTER 2573 10 °C 3 50 350 200 +id:12836 MODBUS_HOLDING_REGISTER 2575 10 °C 3 50 350 200 +id:12837 MODBUS_HOLDING_REGISTER 2577 10 °C 3 50 350 200 +id:12838 MODBUS_HOLDING_REGISTER 2579 10 °C 3 50 350 200 +id:12839 MODBUS_HOLDING_REGISTER 2581 10 °C 3 50 350 200 +id:12840 MODBUS_HOLDING_REGISTER 2583 10 °C 3 50 350 200 +id:12841 MODBUS_HOLDING_REGISTER 2585 10 °C 3 50 350 250 +id:12842 MODBUS_HOLDING_REGISTER 2587 10 °C 3 50 350 250 +id:12843 MODBUS_HOLDING_REGISTER 2589 10 °C 3 50 350 250 +id:12844 MODBUS_HOLDING_REGISTER 2591 10 °C 3 50 350 250 +id:12845 MODBUS_HOLDING_REGISTER 2593 10 °C 3 50 350 250 +id:12846 MODBUS_HOLDING_REGISTER 2595 10 °C 3 50 350 250 +id:12847 MODBUS_HOLDING_REGISTER 2597 10 °C 3 50 350 250 +id:12848 MODBUS_HOLDING_REGISTER 2599 10 °C 3 50 350 250 +id:12849 MODBUS_HOLDING_REGISTER 2601 10 °C 3 50 350 250 +id:12850 MODBUS_HOLDING_REGISTER 2603 10 °C 3 50 350 250 +id:12851 MODBUS_HOLDING_REGISTER 2605 10 °C 3 50 350 250 +id:12852 MODBUS_HOLDING_REGISTER 2607 10 °C 3 50 350 250 +id:12853 MODBUS_HOLDING_REGISTER 2609 10 °C 3 50 350 250 +id:12854 MODBUS_HOLDING_REGISTER 2611 10 °C 3 50 350 250 +id:12855 MODBUS_HOLDING_REGISTER 2613 10 °C 3 50 350 250 +id:12856 MODBUS_HOLDING_REGISTER 2615 10 °C 3 50 350 250 +id:12857 MODBUS_HOLDING_REGISTER 2617 10 °C 3 50 350 250 +id:12858 MODBUS_HOLDING_REGISTER 2619 10 °C 3 50 350 250 +id:12859 MODBUS_HOLDING_REGISTER 2621 10 °C 3 50 350 250 +id:12860 MODBUS_HOLDING_REGISTER 2623 10 °C 3 50 350 250 +id:12861 MODBUS_HOLDING_REGISTER 2625 10 °C 3 50 350 250 +id:12862 MODBUS_HOLDING_REGISTER 2627 10 °C 3 50 350 250 +id:12863 MODBUS_HOLDING_REGISTER 2629 10 °C 3 50 350 250 +id:12864 MODBUS_HOLDING_REGISTER 2631 10 °C 3 50 350 250 +id:12865 MODBUS_HOLDING_REGISTER 2633 10 °C 3 50 350 250 +id:12866 MODBUS_HOLDING_REGISTER 2635 10 °C 3 50 350 250 +id:12867 MODBUS_HOLDING_REGISTER 2637 10 °C 3 50 350 250 +id:12868 MODBUS_HOLDING_REGISTER 2639 10 °C 3 50 350 250 +id:12869 MODBUS_HOLDING_REGISTER 2641 10 °C 3 50 350 250 +id:12870 MODBUS_HOLDING_REGISTER 2643 10 °C 3 50 350 250 +id:12871 MODBUS_HOLDING_REGISTER 2645 10 °C 3 50 350 250 +id:12872 MODBUS_HOLDING_REGISTER 2647 10 °C 3 50 350 250 +id:12873 MODBUS_HOLDING_REGISTER 2649 10 °C 3 50 350 250 +id:12874 MODBUS_HOLDING_REGISTER 2651 10 °C 3 50 350 250 +id:12875 MODBUS_HOLDING_REGISTER 2653 10 °C 3 50 350 250 +id:12876 MODBUS_HOLDING_REGISTER 2655 10 °C 3 50 350 250 +id:12877 MODBUS_HOLDING_REGISTER 2657 10 °C 3 50 350 250 +id:12878 MODBUS_HOLDING_REGISTER 2659 10 °C 3 50 350 250 +id:12879 MODBUS_HOLDING_REGISTER 2661 10 °C 3 50 350 250 +id:12880 MODBUS_HOLDING_REGISTER 2663 10 °C 3 50 350 250 +id:13796 MODBUS_INPUT_REGISTER 2243 1 4 0 0 0 +id:13797 MODBUS_INPUT_REGISTER 2244 1 4 0 0 0 +id:13798 MODBUS_INPUT_REGISTER 2245 1 4 0 0 0 +id:13799 MODBUS_INPUT_REGISTER 2246 1 4 0 0 0 +id:13800 MODBUS_INPUT_REGISTER 2247 1 4 0 0 0 +id:13801 MODBUS_INPUT_REGISTER 2248 1 4 0 0 0 +id:13802 MODBUS_INPUT_REGISTER 2249 1 4 0 0 0 +id:13803 MODBUS_INPUT_REGISTER 2250 1 4 0 0 0 +Offset cooling (EME20) MODBUS_HOLDING_REGISTER 2667 1 1 -10 0 -1 +Offset heating (EME20) MODBUS_HOLDING_REGISTER 2668 1 4 0 10 1 +Offset pool (EME20) MODBUS_HOLDING_REGISTER 2669 1 °C 4 0 10 10 +Cooling (EME20) MODBUS_HOLDING_REGISTER 2666 1 4 0 1 0 +AUX (EME20) MODBUS_HOLDING_REGISTER 2675 1 4 0 1 0 +id:14052 MODBUS_HOLDING_REGISTER 2670 1 kW 6 1 999 1 +id:14061 MODBUS_HOLDING_REGISTER 2672 1 4 0 1 0 +Temperature, Overload, pool MODBUS_HOLDING_REGISTER 0 1 °C 4 1 50 1 +EME20 API MODBUS_HOLDING_REGISTER 2107 1 4 0 1 0 +EME20 API Include own consumption MODBUS_HOLDING_REGISTER 2108 1 4 0 1 0 +EME20 API Available power MODBUS_HOLDING_REGISTER 2109 1 5 0 65535 0 +External adjustment input, main unit (ECS1) MODBUS_HOLDING_REGISTER 2111 1 4 0 1 0 +External adjustment input (ECS2) MODBUS_HOLDING_REGISTER 2112 1 4 0 1 0 +External adjustment input (ECS3) MODBUS_HOLDING_REGISTER 2113 1 4 0 1 0 +External adjustment input (ECS4) MODBUS_HOLDING_REGISTER 2114 1 4 0 1 0 +External adjustment input (ECS5) MODBUS_HOLDING_REGISTER 2115 1 4 0 1 0 +External adjustment input (ECS6) MODBUS_HOLDING_REGISTER 2116 1 4 0 1 0 +External adjustment input (ECS7) MODBUS_HOLDING_REGISTER 2117 1 4 0 1 0 +External adjustment input (ECS8) MODBUS_HOLDING_REGISTER 2118 1 4 0 1 0 +Zone 1 affected by ECS1 MODBUS_HOLDING_REGISTER 2119 1 4 0 1 0 +Zone 2 affected by ECS1 MODBUS_HOLDING_REGISTER 2120 1 4 0 1 0 +Zone 3 affected by ECS1 MODBUS_HOLDING_REGISTER 2121 1 4 0 1 0 +Zone 4 affected by ECS1 MODBUS_HOLDING_REGISTER 2122 1 4 0 1 0 +Zone 5 affected by ECS1 MODBUS_HOLDING_REGISTER 2123 1 4 0 1 0 +Zone 6 affected by ECS1 MODBUS_HOLDING_REGISTER 2124 1 4 0 1 0 +Zone 7 affected by ECS1 MODBUS_HOLDING_REGISTER 2125 1 4 0 1 0 +Zone 8 affected by ECS1 MODBUS_HOLDING_REGISTER 2126 1 4 0 1 0 +Zone 9 affected by ECS1 MODBUS_HOLDING_REGISTER 2127 1 4 0 1 0 +Zone 10 affected by ECS1 MODBUS_HOLDING_REGISTER 2128 1 4 0 1 0 +Zone 11 affected by ECS1 MODBUS_HOLDING_REGISTER 2129 1 4 0 1 0 +Zone 12 affected by ECS1 MODBUS_HOLDING_REGISTER 2130 1 4 0 1 0 +Zone 13 affected by ECS1 MODBUS_HOLDING_REGISTER 2131 1 4 0 1 0 +Zone 14 affected by ECS1 MODBUS_HOLDING_REGISTER 2132 1 4 0 1 0 +Zone 15 affected by ECS1 MODBUS_HOLDING_REGISTER 2133 1 4 0 1 0 +Zone 16 affected by ECS1 MODBUS_HOLDING_REGISTER 2134 1 4 0 1 0 +Zone 17 affected by ECS1 MODBUS_HOLDING_REGISTER 2135 1 4 0 1 0 +Zone 18 affected by ECS1 MODBUS_HOLDING_REGISTER 2136 1 4 0 1 0 +Zone 19 affected by ECS1 MODBUS_HOLDING_REGISTER 2137 1 4 0 1 0 +Zone 20 affected by ECS1 MODBUS_HOLDING_REGISTER 2138 1 4 0 1 0 +Zone 21 affected by ECS1 MODBUS_HOLDING_REGISTER 2139 1 4 0 1 0 +Zone 22 affected by ECS1 MODBUS_HOLDING_REGISTER 2140 1 4 0 1 0 +Zone 23 affected by ECS1 MODBUS_HOLDING_REGISTER 2141 1 4 0 1 0 +Zone 24 affected by ECS1 MODBUS_HOLDING_REGISTER 2142 1 4 0 1 0 +Zone 25 affected by ECS1 MODBUS_HOLDING_REGISTER 2143 1 4 0 1 0 +Zone 26 affected by ECS1 MODBUS_HOLDING_REGISTER 2144 1 4 0 1 0 +Zone 27 affected by ECS1 MODBUS_HOLDING_REGISTER 2145 1 4 0 1 0 +Zone 28 affected by ECS1 MODBUS_HOLDING_REGISTER 2146 1 4 0 1 0 +Zone 29 affected by ECS1 MODBUS_HOLDING_REGISTER 2147 1 4 0 1 0 +Zone 30 affected by ECS1 MODBUS_HOLDING_REGISTER 2148 1 4 0 1 0 +Zone 31 affected by ECS1 MODBUS_HOLDING_REGISTER 2149 1 4 0 1 0 +Zone 32 affected by ECS1 MODBUS_HOLDING_REGISTER 2150 1 4 0 1 0 +Zone 33 affected by ECS1 MODBUS_HOLDING_REGISTER 2151 1 4 0 1 0 +Zone 34 affected by ECS1 MODBUS_HOLDING_REGISTER 2152 1 4 0 1 0 +Zone 35 affected by ECS1 MODBUS_HOLDING_REGISTER 2153 1 4 0 1 0 +Zone 36 affected by ECS1 MODBUS_HOLDING_REGISTER 2154 1 4 0 1 0 +Zone 37 affected by ECS1 MODBUS_HOLDING_REGISTER 2155 1 4 0 1 0 +Zone 38 affected by ECS1 MODBUS_HOLDING_REGISTER 2156 1 4 0 1 0 +Zone 39 affected by ECS1 MODBUS_HOLDING_REGISTER 2157 1 4 0 1 0 +Zone 40 affected by ECS1 MODBUS_HOLDING_REGISTER 2158 1 4 0 1 0 +Zone 1 affected by ECS2 MODBUS_HOLDING_REGISTER 2159 1 4 0 1 0 +Zone 2 affected by ECS2 MODBUS_HOLDING_REGISTER 2160 1 4 0 1 0 +Zone 3 affected by ECS2 MODBUS_HOLDING_REGISTER 2161 1 4 0 1 0 +Zone 4 affected by ECS2 MODBUS_HOLDING_REGISTER 2162 1 4 0 1 0 +Zone 5 affected by ECS2 MODBUS_HOLDING_REGISTER 2163 1 4 0 1 0 +Zone 6 affected by ECS2 MODBUS_HOLDING_REGISTER 2164 1 4 0 1 0 +Zone 7 affected by ECS2 MODBUS_HOLDING_REGISTER 2165 1 4 0 1 0 +Zone 8 affected by ECS2 MODBUS_HOLDING_REGISTER 2166 1 4 0 1 0 +Zone 9 affected by ECS2 MODBUS_HOLDING_REGISTER 2167 1 4 0 1 0 +Zone 10 affected by ECS2 MODBUS_HOLDING_REGISTER 2168 1 4 0 1 0 +Zone 11 affected by ECS2 MODBUS_HOLDING_REGISTER 2169 1 4 0 1 0 +Zone 12 affected by ECS2 MODBUS_HOLDING_REGISTER 2170 1 4 0 1 0 +Zone 13 affected by ECS2 MODBUS_HOLDING_REGISTER 2171 1 4 0 1 0 +Zone 14 affected by ECS2 MODBUS_HOLDING_REGISTER 2172 1 4 0 1 0 +Zone 15 affected by ECS2 MODBUS_HOLDING_REGISTER 2173 1 4 0 1 0 +Zone 16 affected by ECS2 MODBUS_HOLDING_REGISTER 2174 1 4 0 1 0 +Zone 17 affected by ECS2 MODBUS_HOLDING_REGISTER 2175 1 4 0 1 0 +Zone 18 affected by ECS2 MODBUS_HOLDING_REGISTER 2176 1 4 0 1 0 +Zone 19 affected by ECS2 MODBUS_HOLDING_REGISTER 2177 1 4 0 1 0 +Zone 20 affected by ECS2 MODBUS_HOLDING_REGISTER 2178 1 4 0 1 0 +Zone 21 affected by ECS2 MODBUS_HOLDING_REGISTER 2179 1 4 0 1 0 +Zone 22 affected by ECS2 MODBUS_HOLDING_REGISTER 2180 1 4 0 1 0 +Zone 23 affected by ECS2 MODBUS_HOLDING_REGISTER 2181 1 4 0 1 0 +Zone 24 affected by ECS2 MODBUS_HOLDING_REGISTER 2182 1 4 0 1 0 +Zone 25 affected by ECS2 MODBUS_HOLDING_REGISTER 2183 1 4 0 1 0 +Zone 26 affected by ECS2 MODBUS_HOLDING_REGISTER 2184 1 4 0 1 0 +Zone 27 affected by ECS2 MODBUS_HOLDING_REGISTER 2185 1 4 0 1 0 +Zone 28 affected by ECS2 MODBUS_HOLDING_REGISTER 2186 1 4 0 1 0 +Zone 29 affected by ECS2 MODBUS_HOLDING_REGISTER 2187 1 4 0 1 0 +Zone 30 affected by ECS2 MODBUS_HOLDING_REGISTER 2188 1 4 0 1 0 +Zone 31 affected by ECS2 MODBUS_HOLDING_REGISTER 2189 1 4 0 1 0 +Zone 32 affected by ECS2 MODBUS_HOLDING_REGISTER 2190 1 4 0 1 0 +Zone 33 affected by ECS2 MODBUS_HOLDING_REGISTER 2191 1 4 0 1 0 +Zone 34 affected by ECS2 MODBUS_HOLDING_REGISTER 2192 1 4 0 1 0 +Zone 35 affected by ECS2 MODBUS_HOLDING_REGISTER 2193 1 4 0 1 0 +Zone 36 affected by ECS2 MODBUS_HOLDING_REGISTER 2194 1 4 0 1 0 +Zone 37 affected by ECS2 MODBUS_HOLDING_REGISTER 2195 1 4 0 1 0 +Zone 38 affected by ECS2 MODBUS_HOLDING_REGISTER 2196 1 4 0 1 0 +Zone 39 affected by ECS2 MODBUS_HOLDING_REGISTER 2197 1 4 0 1 0 +Zone 40 affected by ECS2 MODBUS_HOLDING_REGISTER 2198 1 4 0 1 0 +Input on ECS1 affects ECS1 MODBUS_HOLDING_REGISTER 2439 1 4 0 1 0 +Input on ECS1 affects ECS2 MODBUS_HOLDING_REGISTER 2440 1 4 0 1 0 +Input on ECS1 affects ECS3 MODBUS_HOLDING_REGISTER 2441 1 4 0 1 0 +Input on ECS1 affects ECS4 MODBUS_HOLDING_REGISTER 2442 1 4 0 1 0 +Input on ECS1 affects ECS5 MODBUS_HOLDING_REGISTER 2443 1 4 0 1 0 +Input on ECS1 affects ECS6 MODBUS_HOLDING_REGISTER 2444 1 4 0 1 0 +Input on ECS1 affects ECS7 MODBUS_HOLDING_REGISTER 2445 1 4 0 1 0 +Input on ECS1 affects ECS8 MODBUS_HOLDING_REGISTER 2446 1 4 0 1 0 +Input on ECS2 affects ECS1 MODBUS_HOLDING_REGISTER 2447 1 4 0 1 0 +Input on ECS2 affects ECS2 MODBUS_HOLDING_REGISTER 2448 1 4 0 1 0 +Input on ECS2 affects ECS3 MODBUS_HOLDING_REGISTER 2449 1 4 0 1 0 +Input on ECS2 affects ECS4 MODBUS_HOLDING_REGISTER 2450 1 4 0 1 0 +Input on ECS2 affects ECS5 MODBUS_HOLDING_REGISTER 2451 1 4 0 1 0 +Input on ECS2 affects ECS6 MODBUS_HOLDING_REGISTER 2452 1 4 0 1 0 +Input on ECS2 affects ECS7 MODBUS_HOLDING_REGISTER 2453 1 4 0 1 0 +Input on ECS2 affects ECS8 MODBUS_HOLDING_REGISTER 2454 1 4 0 1 0 +External setting for adjustment migrated MODBUS_HOLDING_REGISTER 2503 1 4 0 1 0 +Time between filter replacement MODBUS_HOLDING_REGISTER 2676 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2677 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2678 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2679 1 4 1 24 3 +Cooling, passive MODBUS_INPUT_REGISTER 2019 10 kWh 6 0 9999999 0 +id:21077 MODBUS_HOLDING_REGISTER 3020 1 4 0 0 0 +id:21078 MODBUS_HOLDING_REGISTER 3021 1 4 0 0 0 +id:21079 MODBUS_HOLDING_REGISTER 3022 1 4 0 0 0 +id:21080 MODBUS_HOLDING_REGISTER 3023 1 4 0 0 0 +id:21081 MODBUS_HOLDING_REGISTER 3024 1 4 0 0 0 +id:21082 MODBUS_HOLDING_REGISTER 3025 1 4 0 0 0 +id:21083 MODBUS_HOLDING_REGISTER 3026 1 4 0 0 0 +id:21084 MODBUS_HOLDING_REGISTER 3027 1 4 0 0 0 +id:21189 MODBUS_INPUT_REGISTER 2726 1 5 0 0 0 +Return time fan 4 MODBUS_HOLDING_REGISTER 2700 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2701 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2702 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2703 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2704 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2705 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2706 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2707 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2708 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2709 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2710 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2711 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2712 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2713 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2714 1 h 4 1 24 4 +Return time fan 4 MODBUS_HOLDING_REGISTER 2715 1 h 4 1 24 4 +Time between filter replacement MODBUS_HOLDING_REGISTER 2728 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2729 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2730 1 4 1 24 3 +Time between filter replacement MODBUS_HOLDING_REGISTER 2731 1 4 1 24 3 +AUX from Modbus MODBUS_HOLDING_REGISTER 2740 1 4 0 67 0 +AUX from Modbus MODBUS_HOLDING_REGISTER 2741 1 2 0 0 0 +Instantaneous used power MODBUS_INPUT_REGISTER 2166 1 W 6 0 9999999 0 +Heat pump test - Silent mode (EB101/EB102) MODBUS_HOLDING_REGISTER 5101 1 4 0 1 0 +ERS 2 MODBUS_HOLDING_REGISTER 2820 1 4 0 1 0 +ERS 3 MODBUS_HOLDING_REGISTER 2821 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 2822 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 2823 1 4 0 1 0 +ERS 4 MODBUS_HOLDING_REGISTER 2824 1 4 0 1 1 +ERS 4 MODBUS_HOLDING_REGISTER 2825 1 4 0 1 1 +ERS 4 MODBUS_HOLDING_REGISTER 2826 1 4 0 1 1 +ERS 4 MODBUS_HOLDING_REGISTER 2827 1 4 0 1 1 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2857 1 °C 4 0 10 3 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2858 1 °C 4 0 10 3 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2859 1 °C 4 0 10 3 +Min. vent temp. (ERS 4) MODBUS_HOLDING_REGISTER 2860 1 °C 4 0 10 3 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2828 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2829 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2830 1 4 0 2 2 +Blocking actions (ERS 4) MODBUS_HOLDING_REGISTER 2831 1 4 0 2 2 +id:23145 MODBUS_HOLDING_REGISTER 2921 1 4 0 1 0 +id:23146 MODBUS_HOLDING_REGISTER 2922 1 4 0 1 0 +id:23147 MODBUS_HOLDING_REGISTER 2923 1 4 0 1 0 +id:23148 MODBUS_HOLDING_REGISTER 2924 1 4 0 1 0 +id:23149 MODBUS_HOLDING_REGISTER 2836 10 °C 2 -200 410 190 +id:23150 MODBUS_HOLDING_REGISTER 2837 10 °C 2 -200 410 190 +id:23151 MODBUS_HOLDING_REGISTER 2838 10 °C 2 -200 410 190 +id:23152 MODBUS_HOLDING_REGISTER 2839 10 °C 2 -200 410 190 +id:23153 MODBUS_HOLDING_REGISTER 2832 10 °C 2 30 100 30 +id:23154 MODBUS_HOLDING_REGISTER 2833 10 °C 2 30 100 30 +id:23155 MODBUS_HOLDING_REGISTER 2834 10 °C 2 30 100 30 +id:23156 MODBUS_HOLDING_REGISTER 2835 10 °C 2 30 100 30 +Fan mode 5 MODBUS_INPUT_REGISTER 2168 1 % 4 0 0 0 +Fan mode 6 MODBUS_INPUT_REGISTER 2169 1 % 4 0 0 0 +Fan mode 7 MODBUS_INPUT_REGISTER 2170 1 % 4 0 0 0 +Fan mode 8 MODBUS_INPUT_REGISTER 2171 1 % 4 0 0 0 +Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 5392 1 4 0 1 0 +Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 5025 1 4 0 1 0 +Modbus external control MODBUS_HOLDING_REGISTER 5008 1 4 0 1 0 +id:24484 MODBUS_HOLDING_REGISTER 5009 10 °C 2 50 800 450 +id:24485 MODBUS_HOLDING_REGISTER 5010 10 °C 2 50 800 450 +id:24486 MODBUS_HOLDING_REGISTER 5011 10 °C 2 50 800 450 +id:24487 MODBUS_HOLDING_REGISTER 5012 10 °C 2 50 800 450 +id:24488 MODBUS_HOLDING_REGISTER 5013 10 °C 2 50 800 450 +id:24489 MODBUS_HOLDING_REGISTER 5014 10 °C 2 50 800 450 +id:24490 MODBUS_HOLDING_REGISTER 5015 10 °C 2 50 800 450 +id:24491 MODBUS_HOLDING_REGISTER 5016 10 °C 2 50 800 450 +id:24492 MODBUS_HOLDING_REGISTER 5017 10 °C 2 -50 300 250 +id:24493 MODBUS_HOLDING_REGISTER 5018 10 °C 2 -50 300 250 +id:24494 MODBUS_HOLDING_REGISTER 5019 10 °C 2 -50 300 250 +id:24495 MODBUS_HOLDING_REGISTER 5020 10 °C 2 -50 300 250 +id:24496 MODBUS_HOLDING_REGISTER 5021 10 °C 2 -50 300 250 +id:24497 MODBUS_HOLDING_REGISTER 5022 10 °C 2 -50 300 250 +id:24498 MODBUS_HOLDING_REGISTER 5023 10 °C 2 -50 300 250 +id:24499 MODBUS_HOLDING_REGISTER 5024 10 °C 2 -50 300 250 +id:24681 MODBUS_HOLDING_REGISTER 5056 1 4 0 1 0 +id:24682 MODBUS_HOLDING_REGISTER 5057 1 4 0 1 0 +id:24683 MODBUS_HOLDING_REGISTER 5058 1 4 0 255 0 +id:24684 MODBUS_HOLDING_REGISTER 5059 1 4 0 1 0 +id:24969 MODBUS_HOLDING_REGISTER 5060 1 4 0 1 0 +id:24970 MODBUS_HOLDING_REGISTER 5061 1 2 -100 10000 0 +id:24971 MODBUS_HOLDING_REGISTER 5062 1 4 0 1 0 +id:24972 MODBUS_HOLDING_REGISTER 5063 1 5 0 1000 0 +id:24973 MODBUS_HOLDING_REGISTER 5064 1 4 0 1 0 +id:24974 MODBUS_HOLDING_REGISTER 5065 1 4 0 1 0 +id:24975 MODBUS_HOLDING_REGISTER 5066 1 5 0 1000 0 +id:24976 MODBUS_HOLDING_REGISTER 5067 1 4 0 1 0 +id:24977 MODBUS_HOLDING_REGISTER 5068 1 4 0 1 0 +id:24978 MODBUS_HOLDING_REGISTER 5069 1 5 0 1000 0 +id:24979 MODBUS_HOLDING_REGISTER 5070 1 4 0 1 0 +id:24980 MODBUS_HOLDING_REGISTER 5071 1 5 0 1000 0 +Energy log - Produced energy for heating over the past hour MODBUS_INPUT_REGISTER 2283 100 kWh 6 0 0 0 +Energy log - Produced energy for hot water over the past hour MODBUS_INPUT_REGISTER 2285 100 kWh 6 0 0 0 +Energy log - Produced energy for cooling over the past hour MODBUS_INPUT_REGISTER 2289 100 kWh 6 0 0 0 +Energy log - Used energy for heating over the past hour MODBUS_INPUT_REGISTER 2291 100 kWh 6 0 0 0 +Energy log - Used energy for hot water over the past hour MODBUS_INPUT_REGISTER 2293 100 kWh 6 0 0 0 +Energy log - Used energy for cooling over the past hour MODBUS_INPUT_REGISTER 2297 100 kWh 6 0 0 0 +Energy log - Used energy by additional heater for heating over the past hour MODBUS_INPUT_REGISTER 2299 100 kWh 6 0 0 0 +Energy log - Used energy by additional heater for hot water over the past hour MODBUS_INPUT_REGISTER 2301 100 kWh 6 0 0 0 +Energy log - Current power consumption MODBUS_INPUT_REGISTER 2305 100 kWh 6 0 0 0 +Energy log - Current power consumption, components MODBUS_INPUT_REGISTER 2408 100 kWh 6 0 0 0 +Compressor, total time energy storage, main unit (EP14) MODBUS_INPUT_REGISTER 2335 1 h 6 0 2147483647 0 +Compressor, total time energy storage, main unit (EP15) MODBUS_INPUT_REGISTER 2337 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 1 (EP14) MODBUS_INPUT_REGISTER 2339 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 1 (EP15) MODBUS_INPUT_REGISTER 2341 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 2 (EP14) MODBUS_INPUT_REGISTER 2343 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 2 (EP15) MODBUS_INPUT_REGISTER 2345 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 3 (EP14) MODBUS_INPUT_REGISTER 2347 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 3 (EP15) MODBUS_INPUT_REGISTER 2349 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 4 (EP14) MODBUS_INPUT_REGISTER 2351 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 4 (EP15) MODBUS_INPUT_REGISTER 2353 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 5 (EP14) MODBUS_INPUT_REGISTER 2355 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 5 (EP15) MODBUS_INPUT_REGISTER 2357 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 6 (EP14) MODBUS_INPUT_REGISTER 2359 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 6 (EP15) MODBUS_INPUT_REGISTER 2361 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 7 (EP14) MODBUS_INPUT_REGISTER 2363 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 7 (EP15) MODBUS_INPUT_REGISTER 2365 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 8 (EP14) MODBUS_INPUT_REGISTER 2367 1 h 6 0 2147483647 0 +Compressor, total time energy storage, heat pump 8 (EP15) MODBUS_INPUT_REGISTER 2369 1 h 6 0 2147483647 0 +Freeze protection with LP-Dew MODBUS_HOLDING_REGISTER 5077 1 4 0 1 0 +Use LP as freeze protection MODBUS_HOLDING_REGISTER 5076 10 °C 2 -100 200 0 +id:26694 MODBUS_HOLDING_REGISTER 5208 1 4 0 1 0 +id:26695 MODBUS_HOLDING_REGISTER 5209 1 4 0 1 0 +id:26696 MODBUS_HOLDING_REGISTER 5210 1 4 0 1 0 +id:26697 MODBUS_HOLDING_REGISTER 5211 1 4 0 1 0 +id:26698 MODBUS_HOLDING_REGISTER 5212 1 4 0 1 0 +id:26699 MODBUS_HOLDING_REGISTER 5213 1 4 0 1 0 +id:26702 MODBUS_HOLDING_REGISTER 5216 1 4 0 1 0 +id:26703 MODBUS_HOLDING_REGISTER 5217 10 °C 2 0 0 0 +id:26704 MODBUS_HOLDING_REGISTER 5218 10 °C 2 0 0 0 +id:26705 MODBUS_HOLDING_REGISTER 5219 10 °C 2 0 0 0 +id:26706 MODBUS_HOLDING_REGISTER 5220 10 °C 2 0 0 0 +id:26707 MODBUS_HOLDING_REGISTER 5221 10 °C 2 0 0 0 +id:26708 MODBUS_HOLDING_REGISTER 5222 10 °C 2 0 0 0 +id:26711 MODBUS_HOLDING_REGISTER 5225 10 °C 2 0 0 0 +id:26793 MODBUS_INPUT_REGISTER 2375 1 4 0 7 7 +id:26794 MODBUS_INPUT_REGISTER 2376 1 4 0 7 7 +id:26795 MODBUS_INPUT_REGISTER 2377 1 4 0 7 7 +id:26796 MODBUS_INPUT_REGISTER 2378 1 4 0 7 7 +id:26797 MODBUS_INPUT_REGISTER 2379 1 4 0 7 7 +id:26798 MODBUS_INPUT_REGISTER 2380 1 4 0 7 7 +id:26799 MODBUS_INPUT_REGISTER 2381 1 4 0 7 7 +id:26800 MODBUS_INPUT_REGISTER 2382 1 4 0 7 7 +id:26801 MODBUS_INPUT_REGISTER 2383 1 4 0 7 7 +id:26802 MODBUS_INPUT_REGISTER 2384 1 4 0 7 7 +id:26803 MODBUS_INPUT_REGISTER 2385 1 4 0 7 7 +id:26804 MODBUS_INPUT_REGISTER 2386 1 4 0 7 7 +id:26805 MODBUS_INPUT_REGISTER 2387 1 4 0 7 7 +id:26806 MODBUS_INPUT_REGISTER 2388 1 4 0 7 7 +id:26807 MODBUS_INPUT_REGISTER 2389 1 4 0 7 7 +id:26808 MODBUS_INPUT_REGISTER 2390 1 4 0 7 7 +id:26809 MODBUS_INPUT_REGISTER 2391 1 4 0 7 7 +id:26810 MODBUS_INPUT_REGISTER 2392 1 4 0 7 7 +id:26811 MODBUS_INPUT_REGISTER 2393 1 4 0 7 7 +id:26812 MODBUS_INPUT_REGISTER 2394 1 4 0 7 7 +id:26813 MODBUS_INPUT_REGISTER 2395 1 4 0 7 7 +id:26814 MODBUS_INPUT_REGISTER 2396 1 4 0 7 7 +id:26815 MODBUS_INPUT_REGISTER 2397 1 4 0 7 7 +id:26816 MODBUS_INPUT_REGISTER 2398 1 4 0 7 7 +id:26817 MODBUS_HOLDING_REGISTER 5183 1 2 -32768 32767 32767 +id:26818 MODBUS_HOLDING_REGISTER 5184 1 2 -32768 32767 32767 +id:26819 MODBUS_HOLDING_REGISTER 5185 1 2 -32768 32767 32767 +id:26820 MODBUS_HOLDING_REGISTER 5186 1 2 -32768 32767 32767 +id:26821 MODBUS_HOLDING_REGISTER 5187 1 2 -32768 32767 32767 +id:26822 MODBUS_HOLDING_REGISTER 5188 1 2 -32768 32767 32767 +id:26823 MODBUS_HOLDING_REGISTER 5189 1 2 -32768 32767 32767 +id:26824 MODBUS_HOLDING_REGISTER 5190 1 2 -32768 32767 32767 +id:26825 MODBUS_HOLDING_REGISTER 5191 1 2 -32768 32767 32767 +id:26826 MODBUS_HOLDING_REGISTER 5192 1 2 -32768 32767 32767 +id:26827 MODBUS_HOLDING_REGISTER 5193 1 2 -32768 32767 32767 +id:26828 MODBUS_HOLDING_REGISTER 5194 1 2 -32768 32767 32767 +id:26829 MODBUS_HOLDING_REGISTER 5195 1 2 -32768 32767 32767 +id:26830 MODBUS_HOLDING_REGISTER 5196 1 2 -32768 32767 32767 +id:26831 MODBUS_HOLDING_REGISTER 5197 1 2 -32768 32767 32767 +id:26832 MODBUS_HOLDING_REGISTER 5198 1 2 -32768 32767 32767 +id:26833 MODBUS_HOLDING_REGISTER 5199 1 2 -32768 32767 32767 +id:26834 MODBUS_HOLDING_REGISTER 5200 1 2 -32768 32767 32767 +id:26835 MODBUS_HOLDING_REGISTER 5201 1 2 -32768 32767 32767 +id:26836 MODBUS_HOLDING_REGISTER 5202 1 2 -32768 32767 32767 +id:26837 MODBUS_HOLDING_REGISTER 5203 1 2 -32768 32767 32767 +id:26838 MODBUS_HOLDING_REGISTER 5204 1 2 -32768 32767 32767 +id:26839 MODBUS_HOLDING_REGISTER 5205 1 2 -32768 32767 32767 +id:26840 MODBUS_HOLDING_REGISTER 5206 1 2 -32768 32767 32767 +id:26865 MODBUS_HOLDING_REGISTER 5181 1 4 0 1 0 +id:26867 MODBUS_HOLDING_REGISTER 5182 1 4 0 0 0 +Auto mode, start temperature for passive cooling MODBUS_HOLDING_REGISTER 4205 10 °C 2 -200 400 250 +Heating, compressor only MODBUS_INPUT_REGISTER 1585 10 kWh 6 0 0 0 +Hot water, compressor only MODBUS_INPUT_REGISTER 1583 10 kWh 6 0 0 0 +Heating, including int. add. heat MODBUS_INPUT_REGISTER 1577 10 kWh 6 0 0 0 +Hot water, including int. add. heat MODBUS_INPUT_REGISTER 1575 10 kWh 6 0 0 0 +id:27790 MODBUS_INPUT_REGISTER 2437 1 4 0 0 0 +id:27791 MODBUS_INPUT_REGISTER 2438 1 4 0 0 0 +id:27792 MODBUS_INPUT_REGISTER 2439 1 4 0 0 0 +id:27793 MODBUS_INPUT_REGISTER 2440 1 4 0 0 0 +id:27794 MODBUS_INPUT_REGISTER 2441 1 4 0 0 0 +id:27795 MODBUS_INPUT_REGISTER 2442 1 4 0 0 0 +id:27796 MODBUS_INPUT_REGISTER 2443 1 4 0 0 0 +id:27797 MODBUS_INPUT_REGISTER 2444 1 4 0 0 0 +id:27814 MODBUS_INPUT_REGISTER 46 10 A 6 0 0 0 +id:27815 MODBUS_INPUT_REGISTER 48 10 A 6 0 0 0 +id:27816 MODBUS_INPUT_REGISTER 50 10 A 6 0 0 0 +id:27818 MODBUS_HOLDING_REGISTER 5459 1 4 0 1 0 +id:27819 MODBUS_HOLDING_REGISTER 5460 1 4 0 1 0 +id:27854 MODBUS_HOLDING_REGISTER 5078 1 4 0 1 0 +id:27855 MODBUS_HOLDING_REGISTER 5079 1 4 0 100 0 +id:28200 MODBUS_HOLDING_REGISTER 5518 1 4 0 0 0 +id:28201 MODBUS_HOLDING_REGISTER 5519 1 4 0 0 0 +id:28202 MODBUS_HOLDING_REGISTER 5520 1 4 0 0 0 +id:28203 MODBUS_HOLDING_REGISTER 5521 1 4 0 0 0 +id:28204 MODBUS_HOLDING_REGISTER 5522 1 4 0 0 0 +id:28205 MODBUS_HOLDING_REGISTER 5523 1 4 0 0 0 +id:28206 MODBUS_HOLDING_REGISTER 5524 1 4 0 0 0 +id:28207 MODBUS_HOLDING_REGISTER 5525 1 4 0 0 0 +id:28208 MODBUS_HOLDING_REGISTER 5470 1 4 0 0 0 +id:28209 MODBUS_HOLDING_REGISTER 5471 1 4 0 0 0 +id:28210 MODBUS_HOLDING_REGISTER 5472 1 4 0 0 0 +id:28211 MODBUS_HOLDING_REGISTER 5473 1 4 0 0 0 +id:28212 MODBUS_HOLDING_REGISTER 5474 1 4 0 0 0 +id:28213 MODBUS_HOLDING_REGISTER 5475 1 4 0 0 0 +id:28214 MODBUS_HOLDING_REGISTER 5476 1 4 0 0 0 +id:28215 MODBUS_HOLDING_REGISTER 5477 1 4 0 0 0 +id:28216 MODBUS_HOLDING_REGISTER 5494 1 4 0 0 0 +id:28217 MODBUS_HOLDING_REGISTER 5495 1 4 0 0 0 +id:28218 MODBUS_HOLDING_REGISTER 5496 1 4 0 0 0 +id:28219 MODBUS_HOLDING_REGISTER 5497 1 4 0 0 0 +id:28220 MODBUS_HOLDING_REGISTER 5498 1 4 0 0 0 +id:28221 MODBUS_HOLDING_REGISTER 5499 1 4 0 0 0 +id:28222 MODBUS_HOLDING_REGISTER 5500 1 4 0 0 0 +id:28223 MODBUS_HOLDING_REGISTER 5501 1 4 0 0 0 +id:28224 MODBUS_HOLDING_REGISTER 5526 1 Hz 4 0 0 0 +id:28225 MODBUS_HOLDING_REGISTER 5527 1 Hz 4 0 0 0 +id:28226 MODBUS_HOLDING_REGISTER 5528 1 Hz 4 0 0 0 +id:28227 MODBUS_HOLDING_REGISTER 5529 1 Hz 4 0 0 0 +id:28228 MODBUS_HOLDING_REGISTER 5530 1 Hz 4 0 0 0 +id:28229 MODBUS_HOLDING_REGISTER 5531 1 Hz 4 0 0 0 +id:28230 MODBUS_HOLDING_REGISTER 5532 1 Hz 4 0 0 0 +id:28231 MODBUS_HOLDING_REGISTER 5533 1 Hz 4 0 0 0 +id:28232 MODBUS_HOLDING_REGISTER 5542 1 4 0 0 0 +id:28233 MODBUS_HOLDING_REGISTER 5543 1 4 0 0 0 +id:28234 MODBUS_HOLDING_REGISTER 5544 1 4 0 0 0 +id:28235 MODBUS_HOLDING_REGISTER 5545 1 4 0 0 0 +id:28236 MODBUS_HOLDING_REGISTER 5546 1 4 0 0 0 +id:28237 MODBUS_HOLDING_REGISTER 5547 1 4 0 0 0 +id:28238 MODBUS_HOLDING_REGISTER 5548 1 4 0 0 0 +id:28239 MODBUS_HOLDING_REGISTER 5549 1 4 0 0 0 +id:28240 MODBUS_HOLDING_REGISTER 5534 1 4 0 0 0 +id:28241 MODBUS_HOLDING_REGISTER 5535 1 4 0 0 0 +id:28242 MODBUS_HOLDING_REGISTER 5536 1 4 0 0 0 +id:28243 MODBUS_HOLDING_REGISTER 5537 1 4 0 0 0 +id:28244 MODBUS_HOLDING_REGISTER 5538 1 4 0 0 0 +id:28245 MODBUS_HOLDING_REGISTER 5539 1 4 0 0 0 +id:28246 MODBUS_HOLDING_REGISTER 5540 1 4 0 0 0 +id:28247 MODBUS_HOLDING_REGISTER 5541 1 4 0 0 0 +id:28248 MODBUS_HOLDING_REGISTER 5478 1 % 4 0 0 0 +id:28249 MODBUS_HOLDING_REGISTER 5479 1 % 4 0 0 0 +id:28250 MODBUS_HOLDING_REGISTER 5480 1 % 4 0 0 0 +id:28251 MODBUS_HOLDING_REGISTER 5481 1 % 4 0 0 0 +id:28252 MODBUS_HOLDING_REGISTER 5482 1 % 4 0 0 0 +id:28253 MODBUS_HOLDING_REGISTER 5483 1 % 4 0 0 0 +id:28254 MODBUS_HOLDING_REGISTER 5484 1 % 4 0 0 0 +id:28255 MODBUS_HOLDING_REGISTER 5485 1 % 4 0 0 0 +id:28256 MODBUS_HOLDING_REGISTER 5486 1 % 4 0 0 0 +id:28257 MODBUS_HOLDING_REGISTER 5487 1 % 4 0 0 0 +id:28258 MODBUS_HOLDING_REGISTER 5488 1 % 4 0 0 0 +id:28259 MODBUS_HOLDING_REGISTER 5489 1 % 4 0 0 0 +id:28260 MODBUS_HOLDING_REGISTER 5490 1 % 4 0 0 0 +id:28261 MODBUS_HOLDING_REGISTER 5491 1 % 4 0 0 0 +id:28262 MODBUS_HOLDING_REGISTER 5492 1 % 4 0 0 0 +id:28263 MODBUS_HOLDING_REGISTER 5493 1 % 4 0 0 0 +id:28264 MODBUS_HOLDING_REGISTER 5502 1 % 4 0 0 0 +id:28265 MODBUS_HOLDING_REGISTER 5503 1 % 4 0 0 0 +id:28266 MODBUS_HOLDING_REGISTER 5504 1 % 4 0 0 0 +id:28267 MODBUS_HOLDING_REGISTER 5505 1 % 4 0 0 0 +id:28268 MODBUS_HOLDING_REGISTER 5506 1 % 4 0 0 0 +id:28269 MODBUS_HOLDING_REGISTER 5507 1 % 4 0 0 0 +id:28270 MODBUS_HOLDING_REGISTER 5508 1 % 4 0 0 0 +id:28271 MODBUS_HOLDING_REGISTER 5509 1 % 4 0 0 0 +id:28272 MODBUS_HOLDING_REGISTER 5510 1 % 4 0 0 0 +id:28273 MODBUS_HOLDING_REGISTER 5511 1 % 4 0 0 0 +id:28274 MODBUS_HOLDING_REGISTER 5512 1 % 4 0 0 0 +id:28275 MODBUS_HOLDING_REGISTER 5513 1 % 4 0 0 0 +id:28276 MODBUS_HOLDING_REGISTER 5514 1 % 4 0 0 0 +id:28277 MODBUS_HOLDING_REGISTER 5515 1 % 4 0 0 0 +id:28278 MODBUS_HOLDING_REGISTER 5516 1 % 4 0 0 0 +id:28279 MODBUS_HOLDING_REGISTER 5517 1 % 4 0 0 0 +Boiler temperature (BT52) MODBUS_INPUT_REGISTER 3800 10 °C 2 0 0 0 +id:28403 MODBUS_HOLDING_REGISTER 5600 1 3 -1000000 1000000 100 +id:28404 MODBUS_HOLDING_REGISTER 5602 1 3 -1000000 1000000 100 +id:28405 MODBUS_HOLDING_REGISTER 5604 1 3 -1000000 1000000 100 +id:28406 MODBUS_HOLDING_REGISTER 5606 1 3 -1000000 1000000 100 +id:28407 MODBUS_HOLDING_REGISTER 5608 1 3 -1000000 1000000 100 +id:28408 MODBUS_HOLDING_REGISTER 5610 1 3 -1000000 1000000 100 +id:28409 MODBUS_HOLDING_REGISTER 5612 1 3 -1000000 1000000 100 +id:28410 MODBUS_HOLDING_REGISTER 5614 1 3 -1000000 1000000 100 +id:28411 MODBUS_HOLDING_REGISTER 5618 1 3 -1000000 1000000 100 +id:28412 MODBUS_HOLDING_REGISTER 5620 1 3 -1000000 1000000 100 +id:28413 MODBUS_HOLDING_REGISTER 5622 1 3 -1000000 1000000 100 +id:28414 MODBUS_HOLDING_REGISTER 5616 1 3 -1000000 1000000 100 +id:28415 MODBUS_HOLDING_REGISTER 5626 1 3 -1000000 1000000 100 +id:28416 MODBUS_HOLDING_REGISTER 5628 1 3 -1000000 1000000 100 +id:28417 MODBUS_HOLDING_REGISTER 5630 1 3 -1000000 1000000 100 +id:28418 MODBUS_HOLDING_REGISTER 5624 1 3 -1000000 1000000 100 +id:28419 MODBUS_HOLDING_REGISTER 5632 1 3 -1000000 1000000 100 +id:28420 MODBUS_HOLDING_REGISTER 5634 1 3 -1000000 1000000 100 +id:28421 MODBUS_HOLDING_REGISTER 5636 1 3 -1000000 1000000 100 +id:28422 MODBUS_HOLDING_REGISTER 5638 1 3 -1000000 1000000 100 +id:28423 MODBUS_HOLDING_REGISTER 5640 1 3 -1000000 1000000 100 +id:28424 MODBUS_HOLDING_REGISTER 5642 1 3 -1000000 1000000 100 +id:28425 MODBUS_HOLDING_REGISTER 5644 1 3 -1000000 1000000 100 +id:28426 MODBUS_HOLDING_REGISTER 5646 1 3 -1000000 1000000 100 +id:28427 MODBUS_HOLDING_REGISTER 5648 1 3 -1000000 1000000 100 +id:28428 MODBUS_HOLDING_REGISTER 5650 1 3 -1000000 1000000 100 +id:28429 MODBUS_HOLDING_REGISTER 5652 1 3 -1000000 1000000 100 +id:28430 MODBUS_HOLDING_REGISTER 5654 1 3 -1000000 1000000 100 +id:28431 MODBUS_HOLDING_REGISTER 5656 1 3 -1000000 1000000 100 +id:28432 MODBUS_HOLDING_REGISTER 5658 1 3 -1000000 1000000 100 +id:28433 MODBUS_HOLDING_REGISTER 5660 1 3 -1000000 1000000 100 +id:28434 MODBUS_HOLDING_REGISTER 5662 1 3 -1000000 1000000 100 +id:28435 MODBUS_HOLDING_REGISTER 5664 1 3 -1000000 1000000 100 +id:28436 MODBUS_HOLDING_REGISTER 5666 1 3 -1000000 1000000 100 +id:28437 MODBUS_HOLDING_REGISTER 5668 1 3 -1000000 1000000 100 +id:28438 MODBUS_HOLDING_REGISTER 5670 1 3 -1000000 1000000 100 +id:28439 MODBUS_HOLDING_REGISTER 5672 1 3 -1000000 1000000 100 +id:28440 MODBUS_HOLDING_REGISTER 5674 1 3 -1000000 1000000 100 +id:28441 MODBUS_HOLDING_REGISTER 5676 1 3 -1000000 1000000 100 +id:28442 MODBUS_HOLDING_REGISTER 5678 1 3 -1000000 1000000 100 +id:28443 MODBUS_HOLDING_REGISTER 5680 1 3 -1000000 1000000 100 +id:28444 MODBUS_HOLDING_REGISTER 5682 1 3 -1000000 1000000 100 +id:28445 MODBUS_HOLDING_REGISTER 5684 1 3 -1000000 1000000 100 +id:28446 MODBUS_HOLDING_REGISTER 5686 1 3 -1000000 1000000 100 +id:28447 MODBUS_HOLDING_REGISTER 5688 1 3 -1000000 1000000 100 +id:28448 MODBUS_HOLDING_REGISTER 5690 1 3 -1000000 1000000 100 +id:28449 MODBUS_HOLDING_REGISTER 5692 1 3 -1000000 1000000 100 +id:28450 MODBUS_HOLDING_REGISTER 5694 1 3 -1000000 1000000 100 +id:28451 MODBUS_HOLDING_REGISTER 5696 1 3 -1000000 1000000 100 +id:28452 MODBUS_HOLDING_REGISTER 5698 1 3 -1000000 1000000 100 +id:28453 MODBUS_HOLDING_REGISTER 5700 1 3 -1000000 1000000 100 +id:28454 MODBUS_HOLDING_REGISTER 5702 1 3 -1000000 1000000 100 +id:28455 MODBUS_HOLDING_REGISTER 5704 1 3 -1000000 1000000 100 +id:28456 MODBUS_HOLDING_REGISTER 5706 1 3 -1000000 1000000 100 +id:28457 MODBUS_HOLDING_REGISTER 5708 1 3 -1000000 1000000 100 +id:28458 MODBUS_HOLDING_REGISTER 5710 1 3 -1000000 1000000 100 +id:28459 MODBUS_HOLDING_REGISTER 5712 1 3 -1000000 1000000 100 +id:28460 MODBUS_HOLDING_REGISTER 5714 1 3 -1000000 1000000 100 +id:28461 MODBUS_HOLDING_REGISTER 5716 1 3 -1000000 1000000 100 +id:28462 MODBUS_HOLDING_REGISTER 5718 1 3 -1000000 1000000 100 +id:28463 MODBUS_HOLDING_REGISTER 5720 1 3 -1000000 1000000 100 +id:28464 MODBUS_HOLDING_REGISTER 5722 1 3 -1000000 1000000 100 +id:28465 MODBUS_HOLDING_REGISTER 5724 1 3 -1000000 1000000 100 +id:28466 MODBUS_HOLDING_REGISTER 5726 1 3 -1000000 1000000 100 +id:28467 MODBUS_HOLDING_REGISTER 5728 1 3 -1000000 1000000 100 +id:28468 MODBUS_HOLDING_REGISTER 5730 1 3 -1000000 1000000 100 +id:28469 MODBUS_HOLDING_REGISTER 5732 1 3 -1000000 1000000 100 +id:28470 MODBUS_HOLDING_REGISTER 5734 1 3 -1000000 1000000 100 +id:28471 MODBUS_HOLDING_REGISTER 5736 1 3 -1000000 1000000 100 +id:28472 MODBUS_HOLDING_REGISTER 5738 1 3 -1000000 1000000 100 +id:28473 MODBUS_HOLDING_REGISTER 5740 1 3 -1000000 1000000 100 +id:28474 MODBUS_HOLDING_REGISTER 5742 1 3 -1000000 1000000 100 +id:28475 MODBUS_HOLDING_REGISTER 5744 1 3 -1000000 1000000 100 +id:28476 MODBUS_HOLDING_REGISTER 5746 1 3 -1000000 1000000 100 +id:28477 MODBUS_HOLDING_REGISTER 5748 1 3 -1000000 1000000 100 +id:28478 MODBUS_HOLDING_REGISTER 5750 1 3 -1000000 1000000 100 +id:28479 MODBUS_HOLDING_REGISTER 5752 1 3 -1000000 1000000 100 +id:28480 MODBUS_HOLDING_REGISTER 5754 1 3 -1000000 1000000 100 +id:28481 MODBUS_HOLDING_REGISTER 5756 1 3 -1000000 1000000 100 +id:28482 MODBUS_HOLDING_REGISTER 5758 1 3 -1000000 1000000 100 +id:28483 MODBUS_HOLDING_REGISTER 5760 1 3 -1000000 1000000 100 +id:28484 MODBUS_HOLDING_REGISTER 5762 1 3 -1000000 1000000 100 +id:28485 MODBUS_HOLDING_REGISTER 5764 1 3 -1000000 1000000 100 +id:28486 MODBUS_HOLDING_REGISTER 5766 1 3 -1000000 1000000 100 +id:28487 MODBUS_HOLDING_REGISTER 5768 1 3 -1000000 1000000 100 +id:28488 MODBUS_HOLDING_REGISTER 5770 1 3 -1000000 1000000 100 +id:28489 MODBUS_HOLDING_REGISTER 5772 1 3 -1000000 1000000 100 +id:28490 MODBUS_HOLDING_REGISTER 5774 1 3 -1000000 1000000 100 +id:28491 MODBUS_HOLDING_REGISTER 5776 1 3 -1000000 1000000 100 +id:28492 MODBUS_HOLDING_REGISTER 5778 1 3 -1000000 1000000 100 +id:28493 MODBUS_HOLDING_REGISTER 5780 1 3 -1000000 1000000 100 +id:28494 MODBUS_HOLDING_REGISTER 5782 1 3 -1000000 1000000 100 +id:28495 MODBUS_HOLDING_REGISTER 5784 1 3 -1000000 1000000 100 +id:28496 MODBUS_HOLDING_REGISTER 5786 1 3 -1000000 1000000 100 +id:28497 MODBUS_HOLDING_REGISTER 5788 1 3 -1000000 1000000 100 +id:28498 MODBUS_HOLDING_REGISTER 5790 1 3 -1000000 1000000 100 +id:28500 MODBUS_HOLDING_REGISTER 5792 1 3 -1000000 1000000 100 +id:28501 MODBUS_HOLDING_REGISTER 5794 1 3 -1000000 1000000 100 +id:28502 MODBUS_HOLDING_REGISTER 5796 1 3 -1000000 1000000 100 +id:28503 MODBUS_HOLDING_REGISTER 5798 1 3 -1000000 1000000 100 +id:28504 MODBUS_HOLDING_REGISTER 5800 1 3 -1000000 1000000 100 +id:28505 MODBUS_HOLDING_REGISTER 5802 1 3 -1000000 1000000 100 +id:28506 MODBUS_HOLDING_REGISTER 5804 1 3 -1000000 1000000 100 +id:28507 MODBUS_HOLDING_REGISTER 5806 1 3 -1000000 1000000 100 +id:28508 MODBUS_HOLDING_REGISTER 5808 1 3 -1000000 1000000 100 +id:28509 MODBUS_HOLDING_REGISTER 5810 1 3 -1000000 1000000 100 +id:28510 MODBUS_HOLDING_REGISTER 5812 1 3 -1000000 1000000 100 +id:28511 MODBUS_HOLDING_REGISTER 5814 1 3 -1000000 1000000 100 +id:28512 MODBUS_HOLDING_REGISTER 5816 1 3 -1000000 1000000 100 +id:28513 MODBUS_HOLDING_REGISTER 5818 1 3 -1000000 1000000 100 +id:28514 MODBUS_HOLDING_REGISTER 5820 1 3 -1000000 1000000 100 +id:28515 MODBUS_HOLDING_REGISTER 5822 1 3 -1000000 1000000 100 +id:28516 MODBUS_HOLDING_REGISTER 5824 1 3 -1000000 1000000 100 +id:28517 MODBUS_HOLDING_REGISTER 5826 1 3 -1000000 1000000 100 +id:28518 MODBUS_HOLDING_REGISTER 5828 1 3 -1000000 1000000 100 +id:28519 MODBUS_HOLDING_REGISTER 5830 1 3 -1000000 1000000 100 +id:28520 MODBUS_HOLDING_REGISTER 5832 1 3 -1000000 1000000 100 +id:28521 MODBUS_HOLDING_REGISTER 5834 1 3 -1000000 1000000 100 +id:28522 MODBUS_HOLDING_REGISTER 5836 1 3 -1000000 1000000 100 +id:28523 MODBUS_HOLDING_REGISTER 5838 1 3 -1000000 1000000 100 +id:28524 MODBUS_HOLDING_REGISTER 5840 1 3 -1000000 1000000 100 +id:28525 MODBUS_HOLDING_REGISTER 5842 1 3 -1000000 1000000 100 +id:28526 MODBUS_HOLDING_REGISTER 5844 1 3 -1000000 1000000 100 +id:28527 MODBUS_HOLDING_REGISTER 5846 1 3 -1000000 1000000 100 +id:28528 MODBUS_HOLDING_REGISTER 5848 1 3 -1000000 1000000 100 +id:28529 MODBUS_HOLDING_REGISTER 5850 1 3 -1000000 1000000 100 +id:28530 MODBUS_HOLDING_REGISTER 5852 1 3 -1000000 1000000 100 +id:28531 MODBUS_HOLDING_REGISTER 5854 1 3 -1000000 1000000 100 +id:28532 MODBUS_HOLDING_REGISTER 5856 1 3 -1000000 1000000 100 +id:28533 MODBUS_HOLDING_REGISTER 5858 1 3 -1000000 1000000 100 +id:28534 MODBUS_HOLDING_REGISTER 5860 1 3 -1000000 1000000 100 +id:28535 MODBUS_HOLDING_REGISTER 5862 1 3 -1000000 1000000 100 +id:28536 MODBUS_HOLDING_REGISTER 5864 1 3 -1000000 1000000 100 +id:28537 MODBUS_HOLDING_REGISTER 5866 1 3 -1000000 1000000 100 +id:28538 MODBUS_HOLDING_REGISTER 5868 1 3 -1000000 1000000 100 +id:28539 MODBUS_HOLDING_REGISTER 5870 1 3 -1000000 1000000 100 +id:28540 MODBUS_HOLDING_REGISTER 5872 1 3 -1000000 1000000 100 +id:28541 MODBUS_HOLDING_REGISTER 5874 1 3 -1000000 1000000 100 +id:28542 MODBUS_HOLDING_REGISTER 5876 1 3 -1000000 1000000 100 +id:28543 MODBUS_HOLDING_REGISTER 5878 1 3 -1000000 1000000 100 +id:28544 MODBUS_HOLDING_REGISTER 5880 1 3 -1000000 1000000 100 +id:28545 MODBUS_HOLDING_REGISTER 5882 1 3 -1000000 1000000 100 +id:28546 MODBUS_HOLDING_REGISTER 5884 1 3 -1000000 1000000 100 +id:28547 MODBUS_HOLDING_REGISTER 5886 1 3 -1000000 1000000 100 +id:28548 MODBUS_HOLDING_REGISTER 5888 1 3 -1000000 1000000 100 +id:28549 MODBUS_HOLDING_REGISTER 5890 1 3 -1000000 1000000 100 +id:28550 MODBUS_HOLDING_REGISTER 5892 1 3 -1000000 1000000 100 +id:28551 MODBUS_HOLDING_REGISTER 5894 1 3 -1000000 1000000 100 +id:28552 MODBUS_HOLDING_REGISTER 5896 1 3 -1000000 1000000 100 +id:28553 MODBUS_HOLDING_REGISTER 5898 1 3 -1000000 1000000 100 +id:28554 MODBUS_HOLDING_REGISTER 5900 1 3 -1000000 1000000 100 +id:28555 MODBUS_HOLDING_REGISTER 5902 1 3 -1000000 1000000 100 +id:28556 MODBUS_HOLDING_REGISTER 5904 1 3 -1000000 1000000 100 +id:28557 MODBUS_HOLDING_REGISTER 5906 1 3 -1000000 1000000 100 +id:28558 MODBUS_HOLDING_REGISTER 5908 1 3 -1000000 1000000 100 +id:28559 MODBUS_HOLDING_REGISTER 5910 1 3 -1000000 1000000 100 +id:28560 MODBUS_HOLDING_REGISTER 5912 1 3 -1000000 1000000 100 +id:28561 MODBUS_HOLDING_REGISTER 5914 1 3 -1000000 1000000 100 +id:28562 MODBUS_HOLDING_REGISTER 5916 1 3 -1000000 1000000 100 +id:28563 MODBUS_HOLDING_REGISTER 5918 1 3 -1000000 1000000 100 +id:28564 MODBUS_HOLDING_REGISTER 5920 1 3 -1000000 1000000 100 +id:28565 MODBUS_HOLDING_REGISTER 5922 1 3 -1000000 1000000 100 +id:28566 MODBUS_HOLDING_REGISTER 5924 1 3 -1000000 1000000 100 +id:28567 MODBUS_HOLDING_REGISTER 5926 1 3 -1000000 1000000 100 +id:28568 MODBUS_HOLDING_REGISTER 5928 1 3 -1000000 1000000 100 +id:28569 MODBUS_HOLDING_REGISTER 5930 1 3 -1000000 1000000 100 +id:28570 MODBUS_HOLDING_REGISTER 5932 1 3 -1000000 1000000 100 +id:28571 MODBUS_HOLDING_REGISTER 5934 1 3 -1000000 1000000 100 +id:28572 MODBUS_HOLDING_REGISTER 5936 1 3 -1000000 1000000 100 +id:28573 MODBUS_HOLDING_REGISTER 5938 1 3 -1000000 1000000 100 +id:28574 MODBUS_HOLDING_REGISTER 5940 1 3 -1000000 1000000 100 +id:28575 MODBUS_HOLDING_REGISTER 5942 1 3 -1000000 1000000 100 +id:28576 MODBUS_HOLDING_REGISTER 5944 1 3 -1000000 1000000 100 +id:28577 MODBUS_HOLDING_REGISTER 5946 1 3 -1000000 1000000 100 +id:28578 MODBUS_HOLDING_REGISTER 5948 1 3 -1000000 1000000 100 +id:28579 MODBUS_HOLDING_REGISTER 5950 1 3 -1000000 1000000 100 +id:28580 MODBUS_HOLDING_REGISTER 5952 1 3 -1000000 1000000 100 +id:28581 MODBUS_HOLDING_REGISTER 5954 1 3 -1000000 1000000 100 +id:28582 MODBUS_HOLDING_REGISTER 5956 1 3 -1000000 1000000 100 +id:28583 MODBUS_HOLDING_REGISTER 5958 1 3 -1000000 1000000 100 +id:28584 MODBUS_HOLDING_REGISTER 5960 1 3 -1000000 1000000 100 +id:28585 MODBUS_HOLDING_REGISTER 5962 1 3 -1000000 1000000 100 +id:28586 MODBUS_HOLDING_REGISTER 5964 1 3 -1000000 1000000 100 +id:28587 MODBUS_HOLDING_REGISTER 5966 1 3 -1000000 1000000 100 +id:28588 MODBUS_HOLDING_REGISTER 5968 1 3 -1000000 1000000 100 +id:28589 MODBUS_HOLDING_REGISTER 5970 1 3 -1000000 1000000 100 +id:28590 MODBUS_HOLDING_REGISTER 5972 1 3 -1000000 1000000 100 +id:28591 MODBUS_HOLDING_REGISTER 5974 1 3 -1000000 1000000 100 +id:28592 MODBUS_HOLDING_REGISTER 5976 1 3 -1000000 1000000 100 +id:28593 MODBUS_HOLDING_REGISTER 5978 1 3 -1000000 1000000 100 +id:28594 MODBUS_HOLDING_REGISTER 5980 1 3 -1000000 1000000 100 +id:28595 MODBUS_HOLDING_REGISTER 5982 1 3 -1000000 1000000 100 +Temperature: HTS 1 MODBUS_INPUT_REGISTER 2800 10 °C 3 0 0 0 +Humidity: HTS 1 MODBUS_INPUT_REGISTER 3130 10 %RH 3 0 0 0 +Input AUX7 MODBUS_HOLDING_REGISTER 1555 1 4 0 67 0 +Input AUX8 MODBUS_HOLDING_REGISTER 1556 1 4 0 67 0 +Input AUX9 MODBUS_HOLDING_REGISTER 1557 1 4 0 67 0 +id:55076 MODBUS_HOLDING_REGISTER 2877 1 4 0 1 0 +id:55077 MODBUS_HOLDING_REGISTER 2878 1 4 0 1 0 +id:55078 MODBUS_HOLDING_REGISTER 2879 1 4 0 1 0 +id:55079 MODBUS_HOLDING_REGISTER 2880 1 4 0 1 0 +id:55080 MODBUS_HOLDING_REGISTER 2881 1 4 0 1 0 +id:55081 MODBUS_HOLDING_REGISTER 2882 1 4 0 1 0 +id:55082 MODBUS_HOLDING_REGISTER 2883 1 4 0 1 0 +id:55083 MODBUS_HOLDING_REGISTER 2884 1 4 0 1 0 +Immersion heater power, emergency mode MODBUS_HOLDING_REGISTER 3028 100 kW 2 0 4500 600 +Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 3986 1 4 0 1 0 +id:55495 MODBUS_HOLDING_REGISTER 5550 1 4 0 1 0 +id:55496 MODBUS_HOLDING_REGISTER 5207 10 °C 2 0 0 0 diff --git a/nibe/data/s1156.json b/nibe/data/s1156.json new file mode 100644 index 0000000..6b9adf3 --- /dev/null +++ b/nibe/data/s1156.json @@ -0,0 +1,10757 @@ +{ + "30002": { + "title": "Current outdoor temperature (BT1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "current-outdoor-temperature-bt1-30002" + }, + "30003": { + "title": "Supply line (EP23-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep23-bt2-30003" + }, + "30004": { + "title": "Supply line (EP22-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep22-bt2-30004" + }, + "30005": { + "title": "Supply line (EP21-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep21-bt2-30005" + }, + "30006": { + "title": "Supply line (BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-bt2-30006" + }, + "30008": { + "title": "Return line (BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-bt3-30008" + }, + "30009": { + "title": "Hot water top (BT7)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-top-bt7-30009" + }, + "30010": { + "title": "Hot water charging (BT6)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-charging-bt6-30010" + }, + "30011": { + "title": "Brine in (BT10)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "brine-in-bt10-30011" + }, + "30012": { + "title": "Brine out (BT11)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "brine-out-bt11-30012" + }, + "30013": { + "title": "Condenser (BT12)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "condenser-bt12-30013" + }, + "30014": { + "title": "Discharge (BT14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "discharge-bt14-30014" + }, + "30015": { + "title": "Liquid line (BT15)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "liquid-line-bt15-30015" + }, + "30017": { + "title": "Suction gas (BT17)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "suction-gas-bt17-30017" + }, + "30022": { + "title": "Collector in (AZ10-BT26)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-in-az10-bt26-30022" + }, + "30023": { + "title": "Collector out (AZ10-BT27)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-out-az10-bt27-30023" + }, + "30032": { + "title": "Return line (EQ1-BT65)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-eq1-bt65-30032" + }, + "30037": { + "title": "Temperature limiter (EB100-FD1)", + "factor": 1, + "size": "s16", + "name": "temperature-limiter-eb100-fd1-30037" + }, + "30038": { + "title": "Average temperature (BT1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "average-temperature-bt1-30038" + }, + "30039": { + "title": "Boiler temperature (BT52)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "boiler-temperature-bt52-30039" + }, + "30040": { + "title": "External supply line (BT25)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "external-supply-line-bt25-30040" + }, + "30041": { + "title": "Flow sensor (BF1)", + "factor": 10, + "unit": "l/m", + "size": "s16", + "name": "flow-sensor-bf1-30041" + }, + "30042": { + "title": "Electrical anode (EB100-FR1)", + "factor": 1, + "size": "s16", + "name": "electrical-anode-eb100-fr1-30042" + }, + "30060": { + "title": "Pool (CL12-BT51)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "pool-cl12-bt51-30060" + }, + "30067": { + "title": "Collector in (AZ13-BT26)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-in-az13-bt26-30067" + }, + "30068": { + "title": "Collector in (AZ12-BT26)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-in-az12-bt26-30068" + }, + "30069": { + "title": "Collector in (AZ11-BT26)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-in-az11-bt26-30069" + }, + "30070": { + "title": "Collector out (AZ13-BT27)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-out-az13-bt27-30070" + }, + "30071": { + "title": "Collector out (AZ12-BT27)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-out-az12-bt27-30071" + }, + "30072": { + "title": "Collector out (AZ11-BT27)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-out-az11-bt27-30072" + }, + "32309": { + "title": "Low press (BP8)", + "factor": 100, + "unit": "bar", + "size": "s16", + "name": "low-press-bp8-32309" + }, + "30076": { + "title": "Return line (EP23-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep23-bt3-30076" + }, + "30077": { + "title": "Return line (EP22-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep22-bt3-30077" + }, + "30078": { + "title": "Return line (EP21-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep21-bt3-30078" + }, + "30079": { + "title": "Return line (EP15-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep15-bt3-30079" + }, + "30087": { + "title": "Oil temperature (BT29)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "oil-temperature-bt29-30087" + }, + "30088": { + "title": "Outgoing hot water (BT70)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "outgoing-hot-water-bt70-30088" + }, + "30091": { + "title": "Collector (EQ1-BT57)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "collector-eq1-bt57-30091" + }, + "30092": { + "title": "Heating dump (EQ1-BT75)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "heating-dump-eq1-bt75-30092" + }, + "30095": { + "title": "Supply line (EP47-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep47-bt2-30095" + }, + "30096": { + "title": "Supply line (EP46-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep46-bt2-30096" + }, + "30097": { + "title": "Supply line (EP45-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep45-bt2-30097" + }, + "30098": { + "title": "Supply line (EP44-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-ep44-bt2-30098" + }, + "30099": { + "title": "Return line (EP47-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep47-bt3-30099" + }, + "30100": { + "title": "Return line (EP46-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep46-bt3-30100" + }, + "30101": { + "title": "Return line (EP45-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep45-bt3-30101" + }, + "30102": { + "title": "Return line (EP44-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-ep44-bt3-30102" + }, + "30107": { + "title": "Brine in (EP10-BT26)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "brine-in-ep10-bt26-30107" + }, + "30110": { + "title": "Room average temp. clim. system 8 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-8-bt50-30110" + }, + "30111": { + "title": "Room average temp. clim. system 7 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-7-bt50-30111" + }, + "30112": { + "title": "Room average temp. clim. system 6 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-6-bt50-30112" + }, + "30113": { + "title": "Room average temp. clim. system 5 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-5-bt50-30113" + }, + "30114": { + "title": "Room average temp. clim. system 4 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-4-bt50-30114" + }, + "30115": { + "title": "Room average temp. clim. system 3 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-3-bt50-30115" + }, + "30116": { + "title": "Room average temp. clim. system 2 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-2-bt50-30116" + }, + "30117": { + "title": "Room average temp. clim. system 1 (BT50)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "room-average-temp-clim-system-1-bt50-30117" + }, + "30120": { + "title": "External cooling supply temperature (BT25)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "external-cooling-supply-temperature-bt25-30120" + }, + "30130": { + "title": "Oper. mode shunt climate system 8", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-8-30130" + }, + "30131": { + "title": "Oper. mode shunt climate system 7", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-7-30131" + }, + "30132": { + "title": "Oper. mode shunt climate system 6", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-6-30132" + }, + "30133": { + "title": "Oper. mode shunt climate system 5", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-5-30133" + }, + "30135": { + "title": "Relay status (ERS 1)", + "factor": 1, + "size": "u8", + "name": "relay-status-ers-1-30135" + }, + "30136": { + "title": "Fan speed (AZ30-GQ2)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-speed-az30-gq2-30136" + }, + "30137": { + "title": "Fan speed (AZ30-GQ3)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-speed-az30-gq3-30137" + }, + "30138": { + "title": "Current hot water mode controlled by", + "factor": 1, + "size": "s8", + "name": "current-hot-water-mode-controlled-by-30138" + }, + "30139": { + "title": "Inverter limit status", + "factor": 1, + "size": "u8", + "name": "inverter-limit-status-30139" + }, + "42756": { + "title": "Inverter fault reset", + "factor": 1, + "size": "u16", + "name": "inverter-fault-reset-42756", + "write": true + }, + "30141": { + "title": "Requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u16", + "name": "requested-compressor-frequency-30141" + }, + "30142": { + "title": "Max. compressor frequency, heating", + "factor": 100, + "unit": "Hz", + "size": "u16", + "name": "max-compressor-frequency-heating-30142" + }, + "30143": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30143" + }, + "30144": { + "title": "Inverter fault code", + "factor": 1, + "size": "u16", + "name": "inverter-fault-code-30144" + }, + "30145": { + "title": "Inverter run command", + "factor": 1, + "size": "u16", + "name": "inverter-run-command-30145" + }, + "30146": { + "title": "Inverter pic. version", + "factor": 1, + "size": "u16", + "name": "inverter-pic-version-30146" + }, + "30147": { + "title": "Inverter 8051 version", + "factor": 1, + "size": "u16", + "name": "inverter-8051-version-30147" + }, + "30148": { + "title": "Inverter wizard", + "factor": 1, + "size": "u16", + "name": "inverter-wizard-30148" + }, + "30149": { + "title": "Inverter version (MCE)", + "factor": 1, + "size": "u16", + "name": "inverter-version-mce-30149" + }, + "30150": { + "title": "Inverter hw version", + "factor": 1, + "size": "u16", + "name": "inverter-hw-version-30150" + }, + "30151": { + "title": "Inverter hw type", + "factor": 1, + "size": "u16", + "name": "inverter-hw-type-30151" + }, + "30152": { + "title": "External adjustment climate system 8", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-8-30152" + }, + "30153": { + "title": "External adjustment climate system 7", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-7-30153" + }, + "30154": { + "title": "External adjustment climate system 6", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-6-30154" + }, + "30155": { + "title": "External adjustment climate system 5", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-5-30155" + }, + "30157": { + "title": "Climate system 8", + "factor": 1, + "size": "u8", + "name": "climate-system-8-30157" + }, + "30158": { + "title": "Climate system 7", + "factor": 1, + "size": "u8", + "name": "climate-system-7-30158" + }, + "30159": { + "title": "Climate system 6", + "factor": 1, + "size": "u8", + "name": "climate-system-6-30159" + }, + "30160": { + "title": "Climate system 5", + "factor": 1, + "size": "u8", + "name": "climate-system-5-30160" + }, + "30161": { + "title": "Extra cooling", + "factor": 1, + "size": "u8", + "name": "extra-cooling-30161" + }, + "30175": { + "title": "Hot water comfort return (BT82)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-comfort-return-bt82-30175" + }, + "30176": { + "title": "Hot water comfort heater (BT83)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hot-water-comfort-heater-bt83-30176" + }, + "30180": { + "title": "Compressor, total time pool, heat pump 8 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-8-ep15-30180" + }, + "30182": { + "title": "Compressor, total time pool 2, heat pump 8 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-8-ep15-30182" + }, + "30186": { + "title": "Compressor, total time pool, heat pump 8 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-8-ep14-30186" + }, + "30188": { + "title": "Compressor, total time pool 2, heat pump 8 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-8-ep14-30188" + }, + "30192": { + "title": "Compressor, total time pool, heat pump 7 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-7-ep15-30192" + }, + "30194": { + "title": "Compressor, total time pool 2, heat pump 7 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-7-ep15-30194" + }, + "30198": { + "title": "Compressor, total time pool, heat pump 7 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-7-ep14-30198" + }, + "30200": { + "title": "Compressor, total time pool 2, heat pump 7 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-7-ep14-30200" + }, + "30204": { + "title": "Compressor, total time pool, heat pump 6 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-6-ep15-30204" + }, + "30206": { + "title": "Compressor, total time pool 2, heat pump 6 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-6-ep15-30206" + }, + "30210": { + "title": "Compressor, total time pool, heat pump 6 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-6-ep14-30210" + }, + "30212": { + "title": "Compressor, total time pool 2, heat pump 6 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-6-ep14-30212" + }, + "30216": { + "title": "Compressor, total time pool, heat pump 5 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-5-ep15-30216" + }, + "30218": { + "title": "Compressor, total time pool 2, heat pump 5 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-5-ep15-30218" + }, + "30222": { + "title": "Compressor, total time pool, heat pump 5 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-5-ep14-30222" + }, + "30224": { + "title": "Compressor, total time pool 2, heat pump 5 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-5-ep14-30224" + }, + "30228": { + "title": "Compressor, total time pool, heat pump 4 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-4-ep15-30228" + }, + "30230": { + "title": "Compressor, total time pool 2, heat pump 4 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-4-ep15-30230" + }, + "30234": { + "title": "Compressor, total time pool, heat pump 4 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-4-ep14-30234" + }, + "30236": { + "title": "Compressor, total time pool 2, heat pump 4 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-4-ep14-30236" + }, + "30240": { + "title": "Compressor, total time pool, heat pump 3 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-3-ep15-30240" + }, + "30242": { + "title": "Compressor, total time pool 2, heat pump 3 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-3-ep15-30242" + }, + "30246": { + "title": "Compressor, total time pool, heat pump 3 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-3-ep14-30246" + }, + "30248": { + "title": "Compressor, total time pool 2, heat pump 3 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-3-ep14-30248" + }, + "30252": { + "title": "Compressor, total time pool, heat pump 2 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-2-ep15-30252" + }, + "30254": { + "title": "Compressor, total time pool 2, heat pump 2 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-2-ep15-30254" + }, + "30258": { + "title": "Compressor, total time pool, heat pump 2 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-heat-pump-2-ep14-30258" + }, + "30260": { + "title": "Compressor, total time pool 2, heat pump 2 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-heat-pump-2-ep14-30260" + }, + "30264": { + "title": "Compressor, total time pool, heat pump 1 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-heat-pump-1-ep15-30264" + }, + "30266": { + "title": "Compressor, total time pool 2, heat pump 1 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-total-time-pool-2-heat-pump-1-ep15-30266" + }, + "30280": { + "title": "Compressor, total time cooling, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-cooling-main-unit-ep14-30280" + }, + "30282": { + "title": "Compressor, total time pool, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-main-unit-ep14-30282" + }, + "30284": { + "title": "Compressor, total time pool 2, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-pool-2-main-unit-ep14-30284" + }, + "30295": { + "title": "Heat pump 8 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-8-requested-compressor-frequency-30295" + }, + "30296": { + "title": "Heat pump 7 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-7-requested-compressor-frequency-30296" + }, + "30297": { + "title": "Heat pump 6 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-6-requested-compressor-frequency-30297" + }, + "30298": { + "title": "Heat pump 5 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-5-requested-compressor-frequency-30298" + }, + "30299": { + "title": "Heat pump 4 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-4-requested-compressor-frequency-30299" + }, + "30300": { + "title": "Heat pump 3 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-3-requested-compressor-frequency-30300" + }, + "30301": { + "title": "Heat pump 2 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-2-requested-compressor-frequency-30301" + }, + "30302": { + "title": "Heat pump 1 requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "heat-pump-1-requested-compressor-frequency-30302" + }, + "30304": { + "title": "Frost protection heat exchanger heat pump 8", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-8-30304" + }, + "30305": { + "title": "Frost protection heat exchanger heat pump 7", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-7-30305" + }, + "30306": { + "title": "Frost protection heat exchanger heat pump 6", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-6-30306" + }, + "30307": { + "title": "Frost protection heat exchanger heat pump 5", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-5-30307" + }, + "30308": { + "title": "Frost protection heat exchanger heat pump 4", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-4-30308" + }, + "30309": { + "title": "Frost protection heat exchanger heat pump 3", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-3-30309" + }, + "30310": { + "title": "Frost protection heat exchanger heat pump 2", + "factor": 1, + "size": "u8", + "name": "frost-protection-heat-exchanger-heat-pump-2-30310" + }, + "30312": { + "title": "Status (OPT)", + "factor": 1, + "size": "u8", + "name": "status-opt-30312" + }, + "30313": { + "title": "Version (OPT)", + "factor": 1, + "size": "u16", + "name": "version-opt-30313" + }, + "30314": { + "title": "OPT relay, modulation level", + "factor": 10, + "unit": "%", + "size": "s16", + "name": "opt-relay-modulation-level-30314" + }, + "30316": { + "title": "OPT operating time", + "factor": 1, + "unit": "h", + "size": "u16", + "name": "opt-operating-time-30316" + }, + "32022": { + "title": "Compressor restrictions", + "factor": 1, + "size": "u32", + "name": "compressor-restrictions-32022" + }, + "30318": { + "title": "Available compressors heating", + "factor": 1, + "size": "u8", + "name": "available-compressors-heating-30318" + }, + "30319": { + "title": "Available compressors hot water", + "factor": 1, + "size": "u8", + "name": "available-compressors-hot-water-30319" + }, + "30320": { + "title": "Available compressors pool 1", + "factor": 1, + "size": "u8", + "name": "available-compressors-pool-1-30320" + }, + "30321": { + "title": "Available compressors pool 2", + "factor": 1, + "size": "u8", + "name": "available-compressors-pool-2-30321" + }, + "30322": { + "title": "Available compressors cooling", + "factor": 1, + "size": "u8", + "name": "available-compressors-cooling-30322" + }, + "30323": { + "title": "Available compressors external control", + "factor": 1, + "size": "u8", + "name": "available-compressors-external-control-30323" + }, + "30324": { + "title": "Humidity (BM1)", + "factor": 10, + "unit": "%", + "size": "s16", + "name": "humidity-bm1-30324" + }, + "30325": { + "title": "Temperature (BM1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-bm1-30325" + }, + "30326": { + "title": "Pressure (BM1)", + "factor": 10, + "unit": "kPa", + "size": "s16", + "name": "pressure-bm1-30326" + }, + "30327": { + "title": "Dew point (BM1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "dew-point-bm1-30327" + }, + "30338": { + "title": "Supply temperature (BT64)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-temperature-bt64-30338" + }, + "30339": { + "title": "Heat pump functionality 2", + "factor": 1, + "size": "u32", + "name": "heat-pump-functionality-2-30339" + }, + "30341": { + "title": "Status (EQ1)", + "factor": 1, + "size": "u8", + "name": "status-eq1-30341" + }, + "30342": { + "title": "Status, heating dump shunt (EQ1)", + "factor": 1, + "size": "u8", + "name": "status-heating-dump-shunt-eq1-30342" + }, + "40012": { + "title": "Degree minutes", + "factor": 10, + "unit": "DM", + "size": "s32", + "min": -30000.0, + "max": 30000.0, + "default": 0.0, + "name": "degree-minutes-40012", + "write": true + }, + "30359": { + "title": "Blocking (ERS 1)", + "factor": 1, + "size": "u8", + "name": "blocking-ers-1-30359" + }, + "30360": { + "title": "AZ30-EB17", + "factor": 1, + "size": "u8", + "name": "az30-eb17-30360" + }, + "30386": { + "title": "Seconds of blank time left, charge pump 8", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-8-30386" + }, + "30387": { + "title": "Seconds of blank time left, charge pump 7", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-7-30387" + }, + "30388": { + "title": "Seconds of blank time left, charge pump 6", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-6-30388" + }, + "30389": { + "title": "Seconds of blank time left, charge pump 5", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-5-30389" + }, + "30390": { + "title": "Seconds of blank time left, charge pump 4", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-4-30390" + }, + "30391": { + "title": "Seconds of blank time left, charge pump 3", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-3-30391" + }, + "30392": { + "title": "Seconds of blank time left, charge pump 2", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-2-30392" + }, + "30393": { + "title": "Seconds of blank time left, charge pump 1", + "factor": 1, + "size": "u8", + "name": "seconds-of-blank-time-left-charge-pump-1-30393" + }, + "30395": { + "title": "Inverter min speed", + "factor": 1, + "size": "u16", + "name": "inverter-min-speed-30395" + }, + "30396": { + "title": "Inverter max speed", + "factor": 1, + "size": "u16", + "name": "inverter-max-speed-30396" + }, + "30403": { + "title": "Max fan speed (EB101)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb101-30403" + }, + "30404": { + "title": "Min fan speed (EB101)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb101-30404" + }, + "30407": { + "title": "Generated power heating (EB101)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb101-30407" + }, + "30408": { + "title": "Time to defrosting (EB101)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb101-30408" + }, + "30409": { + "title": "Defrosting index (EB101)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb101-30409" + }, + "30410": { + "title": "Superheat reference EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb101-30410" + }, + "30411": { + "title": "Superheat EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb101-30411" + }, + "30412": { + "title": "EEV-ssh-error (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb101-30412" + }, + "30413": { + "title": "Superheat temp. reference EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb101-30413" + }, + "30414": { + "title": "Set point value EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb101-30414" + }, + "30415": { + "title": "EEV PV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb101-30415" + }, + "30416": { + "title": "EEV-te-error average open (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb101-30416" + }, + "30417": { + "title": "Degree of opening EEV (EB101)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb101-30417" + }, + "30418": { + "title": "Superheat reference EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb101-30418" + }, + "30419": { + "title": "Superheat EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb101-30419" + }, + "30420": { + "title": "EEV-ssh-error (EVI)(EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb101-30420" + }, + "30421": { + "title": "Superheat temp. reference EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb101-30421" + }, + "30422": { + "title": "Set point value EVI (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb101-30422" + }, + "30423": { + "title": "EVI PV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb101-30423" + }, + "30424": { + "title": "EEV-te-error average open in (EVI)(EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-in-evi-eb101-30424" + }, + "30425": { + "title": "Degree of opening EVI (EB101)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb101-30425" + }, + "30439": { + "title": "Low press (EB108 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb108-bp8-dew-30439" + }, + "30440": { + "title": "Hi press (EB108 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb108-bp9-dew-30440" + }, + "30442": { + "title": "Pressure sensor, injection (EB108-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb108-bp11-30442" + }, + "30443": { + "title": "EVI pressure (EB108-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb108-ep14-bp11-dew-30443" + }, + "30445": { + "title": "Fan status (EB108-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb108-ep14-30445" + }, + "30446": { + "title": "Fan rpm (EB108-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb108-ep14-30446" + }, + "30455": { + "title": "Low press (EB107 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb107-bp8-dew-30455" + }, + "30456": { + "title": "Hi press (EB107 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb107-bp9-dew-30456" + }, + "30458": { + "title": "Pressure sensor, injection (EB107-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb107-bp11-30458" + }, + "30459": { + "title": "EVI pressure (EB107-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb107-ep14-bp11-dew-30459" + }, + "30461": { + "title": "Fan status (EB107-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb107-ep14-30461" + }, + "30462": { + "title": "Fan rpm (EB107-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb107-ep14-30462" + }, + "30471": { + "title": "Low press (EB106 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb106-bp8-dew-30471" + }, + "30472": { + "title": "Hi press (EB106 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb106-bp9-dew-30472" + }, + "30474": { + "title": "Pressure sensor, injection (EB106-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb106-bp11-30474" + }, + "30475": { + "title": "EVI pressure (EB106-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb106-ep14-bp11-dew-30475" + }, + "30477": { + "title": "Fan status (EB106-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb106-ep14-30477" + }, + "30478": { + "title": "Fan rpm (EB106-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb106-ep14-30478" + }, + "30487": { + "title": "Low press (EB105 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb105-bp8-dew-30487" + }, + "30488": { + "title": "Hi press (EB105 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb105-bp9-dew-30488" + }, + "30490": { + "title": "Pressure sensor, injection (EB105-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb105-bp11-30490" + }, + "30491": { + "title": "EVI pressure (EB105-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb105-ep14-bp11-dew-30491" + }, + "30493": { + "title": "Fan status (EB105-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb105-ep14-30493" + }, + "30494": { + "title": "Fan rpm (EB105-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb105-ep14-30494" + }, + "30503": { + "title": "Low press (EB104 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb104-bp8-dew-30503" + }, + "30504": { + "title": "Hi press (EB104 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb104-bp9-dew-30504" + }, + "30506": { + "title": "Pressure sensor, injection (EB104-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb104-bp11-30506" + }, + "30507": { + "title": "EVI pressure (EB104-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb104-ep14-bp11-dew-30507" + }, + "30509": { + "title": "Fan status (EB104-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb104-ep14-30509" + }, + "30510": { + "title": "Fan rpm (EB104-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb104-ep14-30510" + }, + "30519": { + "title": "Low press (EB103 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb103-bp8-dew-30519" + }, + "30520": { + "title": "Hi press (EB103 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb103-bp9-dew-30520" + }, + "30522": { + "title": "Pressure sensor, injection (EB103-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb103-bp11-30522" + }, + "30523": { + "title": "EVI pressure (EB103-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb103-ep14-bp11-dew-30523" + }, + "30525": { + "title": "Fan status (EB103-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb103-ep14-30525" + }, + "30526": { + "title": "Fan rpm (EB103-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb103-ep14-30526" + }, + "30535": { + "title": "Low press (EB102 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb102-bp8-dew-30535" + }, + "30536": { + "title": "Hi press (EB102 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb102-bp9-dew-30536" + }, + "30538": { + "title": "Pressure sensor, injection (EB102-EP14-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb102-ep14-bp11-30538" + }, + "30539": { + "title": "EVI pressure (EB102-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb102-ep14-bp11-dew-30539" + }, + "30541": { + "title": "Fan status (EB102-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb102-ep14-30541" + }, + "30542": { + "title": "Fan rpm (EB102-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb102-ep14-30542" + }, + "30551": { + "title": "Low press (EB101 BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb101-bp8-dew-30551" + }, + "30552": { + "title": "Hi press (EB101 BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "hi-press-eb101-bp9-dew-30552" + }, + "30554": { + "title": "Pressure sensor, injection (EB101-BP11)", + "factor": 10, + "size": "s16", + "name": "pressure-sensor-injection-eb101-bp11-30554" + }, + "30555": { + "title": "EVI pressure (EB101-EP14-BP11 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pressure-eb101-ep14-bp11-dew-30555" + }, + "30557": { + "title": "Fan status (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-status-eb101-ep14-30557" + }, + "30558": { + "title": "Fan rpm (EB101-EP14)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-rpm-eb101-ep14-30558" + }, + "30580": { + "title": "Operating mode PV panels", + "factor": 1, + "size": "u8", + "name": "operating-mode-pv-panels-30580" + }, + "30582": { + "title": "EME lux mode without EME", + "factor": 1, + "size": "u8", + "name": "eme-lux-mode-without-eme-30582" + }, + "30583": { + "title": "Timer (EME)", + "factor": 60, + "unit": "min", + "size": "u16", + "name": "timer-eme-30583" + }, + "30591": { + "title": "Fan mode 4", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-4-30591" + }, + "30592": { + "title": "Fan mode 3", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-3-30592" + }, + "30593": { + "title": "Fan mode 2", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-2-30593" + }, + "30594": { + "title": "Is the compressor accessible", + "factor": 1, + "size": "u8", + "name": "is-the-compressor-accessible-30594" + }, + "30605": { + "title": "Prio, hot water (OPT)", + "factor": 1, + "size": "u8", + "name": "prio-hot-water-opt-30605" + }, + "30684": { + "title": "Permit (undefined)", + "factor": 1, + "size": "u8", + "name": "permit-undefined-30684" + }, + "30685": { + "title": "Permit (undefined)", + "factor": 1, + "size": "u8", + "name": "permit-undefined-30685" + }, + "30686": { + "title": "Permit (undefined)", + "factor": 1, + "size": "u8", + "name": "permit-undefined-30686" + }, + "30687": { + "title": "Permit (OPT 10) additional heat", + "factor": 1, + "size": "u8", + "name": "permit-opt-10-additional-heat-30687" + }, + "30688": { + "title": "Permit ext. imm. heater step", + "factor": 1, + "size": "u8", + "name": "permit-ext-imm-heater-step-30688" + }, + "30689": { + "title": "Permit int. imm. heater step", + "factor": 1, + "size": "u8", + "name": "permit-int-imm-heater-step-30689" + }, + "30690": { + "title": "Permit shunted additional heat", + "factor": 1, + "size": "u8", + "name": "permit-shunted-additional-heat-30690" + }, + "30691": { + "title": "Permit prioritised additional heat", + "factor": 1, + "size": "u8", + "name": "permit-prioritised-additional-heat-30691" + }, + "30692": { + "title": "Permit (EB108-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb108-ep15-30692" + }, + "30693": { + "title": "Permit (EB107-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb107-ep15-30693" + }, + "30694": { + "title": "Permit (EB106-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb106-ep15-30694" + }, + "30695": { + "title": "Permit (EB105-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb105-ep15-30695" + }, + "30696": { + "title": "Permit (EB104-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb104-ep15-30696" + }, + "30697": { + "title": "Permit (EB103-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb103-ep15-30697" + }, + "30698": { + "title": "Permit (EB102-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb102-ep15-30698" + }, + "30699": { + "title": "Permit (EB101-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb101-ep15-30699" + }, + "30700": { + "title": "Permit (EB100-EP15)", + "factor": 1, + "size": "u8", + "name": "permit-eb100-ep15-30700" + }, + "30701": { + "title": "Permit (EB108-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb108-ep14-30701" + }, + "30702": { + "title": "Permit (EB107-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb107-ep14-30702" + }, + "30703": { + "title": "Permit (EB106-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb106-ep14-30703" + }, + "30704": { + "title": "Permit (EB105-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb105-ep14-30704" + }, + "30705": { + "title": "Permit (EB104-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb104-ep14-30705" + }, + "30706": { + "title": "Permit (EB103-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb103-ep14-30706" + }, + "30707": { + "title": "Permit (EB102-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb102-ep14-30707" + }, + "30708": { + "title": "Permit (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb101-ep14-30708" + }, + "30709": { + "title": "Permit (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "permit-eb100-ep14-30709" + }, + "30710": { + "title": "Smart energy source, priority 7, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-7-start-dm-30710" + }, + "30712": { + "title": "Smart energy source, priority 6, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-6-start-dm-30712" + }, + "30714": { + "title": "Smart energy source, priority 5, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-5-start-dm-30714" + }, + "30716": { + "title": "Smart energy source, priority 4, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-4-start-dm-30716" + }, + "30718": { + "title": "Smart energy source, priority 3, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-3-start-dm-30718" + }, + "30720": { + "title": "Smart energy source, priority 2, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-2-start-dm-30720" + }, + "30722": { + "title": "Smart energy source, priority 1, start DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-1-start-dm-30722" + }, + "30724": { + "title": "Smart energy source, priority 7, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-7-stop-dm-30724" + }, + "30726": { + "title": "Smart energy source, priority 6, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-6-stop-dm-30726" + }, + "30728": { + "title": "Smart energy source, priority 5, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-5-stop-dm-30728" + }, + "30730": { + "title": "Smart energy source, priority 4, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-4-stop-dm-30730" + }, + "30732": { + "title": "Smart energy source, priority 3, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-3-stop-dm-30732" + }, + "30734": { + "title": "Smart energy source, priority 2, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-2-stop-dm-30734" + }, + "30736": { + "title": "Smart energy source, priority 1, stop DM", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-priority-1-stop-dm-30736" + }, + "30738": { + "title": "Smart energy source, DM minimum value", + "factor": 1, + "size": "s32", + "name": "smart-energy-source-dm-minimum-value-30738" + }, + "30746": { + "title": "External guide status", + "factor": 1, + "size": "u8", + "name": "external-guide-status-30746" + }, + "30747": { + "title": "Test guide value", + "factor": 1, + "size": "u16", + "name": "test-guide-value-30747" + }, + "30748": { + "title": "Temp. lux forces start of hot water demand", + "factor": 1, + "size": "u8", + "name": "temp-lux-forces-start-of-hot-water-demand-30748" + }, + "30760": { + "title": "Wood boiler activated", + "factor": 1, + "size": "u8", + "name": "wood-boiler-activated-30760" + }, + "30763": { + "title": "Max fan speed (EB108-F21x0)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb108-f21x0-30763" + }, + "30764": { + "title": "Min fan speed (EB108)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb108-30764" + }, + "30767": { + "title": "Generated power heating (EB108)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb108-30767" + }, + "30768": { + "title": "Time to defrosting (EB108)", + "factor": 1, + "unit": "min", + "size": "u16", + "name": "time-to-defrosting-eb108-30768" + }, + "30769": { + "title": "Defrosting index (EB108)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb108-30769" + }, + "30770": { + "title": "Superheat reference EEV (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb108-30770" + }, + "30771": { + "title": "Superheat EEV (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb108-30771" + }, + "30772": { + "title": "EEV-ssh-error (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb108-30772" + }, + "30773": { + "title": "Superheat temp. reference EEV (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb108-30773" + }, + "30774": { + "title": "Set point value EEV (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb108-30774" + }, + "30775": { + "title": "EEV PV (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb108-30775" + }, + "30776": { + "title": "EEV-te-error average open (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb108-30776" + }, + "30777": { + "title": "Degree of opening EEV (EB108)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb108-30777" + }, + "30778": { + "title": "Superheat reference EVI (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb108-30778" + }, + "30779": { + "title": "Superheat EVI (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb108-30779" + }, + "30780": { + "title": "EEV-ssh-error (EVI)(EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb108-30780" + }, + "30781": { + "title": "Superheat temp. reference EVI (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb108-30781" + }, + "30782": { + "title": "Set point value EVI (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb108-30782" + }, + "30783": { + "title": "EVI PV (EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb108-30783" + }, + "30784": { + "title": "EEV-te-error average open (EVI)(EB108)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb108-30784" + }, + "30785": { + "title": "Degree of opening EVI (EB108)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb108-30785" + }, + "30788": { + "title": "Max fan speed (EB107)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb107-30788" + }, + "30789": { + "title": "Min fan speed (EB107)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb107-30789" + }, + "30792": { + "title": "Generated power heating (EB107)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb107-30792" + }, + "30794": { + "title": "Defrosting index (EB107)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb107-30794" + }, + "30795": { + "title": "Superheat reference EEV (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb107-30795" + }, + "30796": { + "title": "Superheat EEV (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb107-30796" + }, + "30797": { + "title": "EEV-ssh-error (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb107-30797" + }, + "30798": { + "title": "Superheat temp. reference EEV (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb107-30798" + }, + "30799": { + "title": "Set point value EEV (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb107-30799" + }, + "30800": { + "title": "EEV PV (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb107-30800" + }, + "30801": { + "title": "EEV-te-error average open (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb107-30801" + }, + "30802": { + "title": "Degree of opening EEV (EB107)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb107-30802" + }, + "30803": { + "title": "Superheat reference EVI (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb107-30803" + }, + "30804": { + "title": "Superheat EVI (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb107-30804" + }, + "30805": { + "title": "EEV-ssh-error (EVI)(EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb107-30805" + }, + "30806": { + "title": "Superheat temp. reference EVI (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb107-30806" + }, + "30807": { + "title": "Set point value EVI (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb107-30807" + }, + "30808": { + "title": "EVI PV (EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb107-30808" + }, + "30809": { + "title": "EEV-te-error average open (EVI)(EB107)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb107-30809" + }, + "30810": { + "title": "Degree of opening EVI (EB107)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb107-30810" + }, + "30813": { + "title": "Max fan speed (EB106)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb106-30813" + }, + "30817": { + "title": "Generated power heating (EB106)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb106-30817" + }, + "30819": { + "title": "Defrosting index (EB106)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb106-30819" + }, + "30820": { + "title": "Superheat reference EEV (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb106-30820" + }, + "30821": { + "title": "Superheat EEV (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb106-30821" + }, + "30822": { + "title": "EEV-ssh-error (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb106-30822" + }, + "30823": { + "title": "Superheat temp. reference EEV (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb106-30823" + }, + "30824": { + "title": "Set point value EEV (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb106-30824" + }, + "30825": { + "title": "EEV PV (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb106-30825" + }, + "30826": { + "title": "EEV-te-error average open (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb106-30826" + }, + "30827": { + "title": "Degree of opening EEV (EB106)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb106-30827" + }, + "30828": { + "title": "Superheat reference EVI (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb106-30828" + }, + "30829": { + "title": "Superheat EVI (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb106-30829" + }, + "30830": { + "title": "EEV-ssh-error (EVI)(EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb106-30830" + }, + "30831": { + "title": "Superheat temp. reference EVI (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb106-30831" + }, + "30832": { + "title": "Set point value EVI (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb106-30832" + }, + "30833": { + "title": "EVI PV (EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb106-30833" + }, + "30834": { + "title": "EEV-te-error average open (EVI)(EB106)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb106-30834" + }, + "30835": { + "title": "Degree of opening EVI (EB106)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb106-30835" + }, + "30838": { + "title": "Max fan speed (EB105)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb105-30838" + }, + "30839": { + "title": "Min fan speed (EB105)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb105-30839" + }, + "30842": { + "title": "Generated power heating (EB105)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb105-30842" + }, + "30844": { + "title": "Defrosting index (EB105)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb105-30844" + }, + "30845": { + "title": "Superheat reference EEV (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb105-30845" + }, + "30846": { + "title": "Superheat EEV (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb105-30846" + }, + "30847": { + "title": "EEV-ssh-error (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb105-30847" + }, + "30848": { + "title": "Superheat temp. reference EEV (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb105-30848" + }, + "30849": { + "title": "Set point value EEV (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb105-30849" + }, + "30850": { + "title": "EEV PV (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb105-30850" + }, + "30851": { + "title": "EEV-te-error average open (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb105-30851" + }, + "30852": { + "title": "Degree of opening EEV (EB105)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb105-30852" + }, + "30853": { + "title": "Superheat reference EVI (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb105-30853" + }, + "30854": { + "title": "Superheat EVI (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb105-30854" + }, + "30855": { + "title": "EEV-ssh-error (EVI)(EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb105-30855" + }, + "30856": { + "title": "Superheat temp. reference EVI (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb105-30856" + }, + "30857": { + "title": "Set point value EVI (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb105-30857" + }, + "30858": { + "title": "EVI PV (EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb105-30858" + }, + "30859": { + "title": "EEV-te-error average open (EVI)(EB105)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb105-30859" + }, + "30860": { + "title": "Degree of opening EVI (EB105)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb105-30860" + }, + "30863": { + "title": "Max fan speed (EB104)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb104-30863" + }, + "30864": { + "title": "Min fan speed (EB104)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb104-30864" + }, + "30867": { + "title": "Generated power heating (EB104)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb104-30867" + }, + "30869": { + "title": "Defrosting index (EB104)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb104-30869" + }, + "30870": { + "title": "Superheat reference EEV (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb104-30870" + }, + "30871": { + "title": "Superheat EEV (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb104-30871" + }, + "30872": { + "title": "EEV-ssh-error (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb104-30872" + }, + "30873": { + "title": "Superheat temp. reference EEV (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb104-30873" + }, + "30874": { + "title": "Set point value EEV (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb104-30874" + }, + "30875": { + "title": "EEV PV (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb104-30875" + }, + "30876": { + "title": "EEV-te-error average open (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb104-30876" + }, + "30877": { + "title": "Degree of opening EEV (EB104)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb104-30877" + }, + "30878": { + "title": "Superheat reference EVI (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb104-30878" + }, + "30879": { + "title": "Superheat EVI (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb104-30879" + }, + "30880": { + "title": "EEV-ssh-error (EVI)(EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb104-30880" + }, + "30881": { + "title": "Superheat temp. reference EVI (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb104-30881" + }, + "30882": { + "title": "Set point value EVI (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb104-30882" + }, + "30883": { + "title": "EVI PV (EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb104-30883" + }, + "30884": { + "title": "EEV-te-error average open (EVI)(EB104)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb104-30884" + }, + "30885": { + "title": "Degree of opening EVI (EB104)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb104-30885" + }, + "30888": { + "title": "Max fan speed (EB103)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb103-30888" + }, + "30889": { + "title": "Min fan speed (EB103)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb103-30889" + }, + "30892": { + "title": "Generated power heating (EB103)", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb103-30892" + }, + "30894": { + "title": "Defrosting index (EB103)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb103-30894" + }, + "30895": { + "title": "Superheat reference EEV (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb103-30895" + }, + "30896": { + "title": "Superheat EEV (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb103-30896" + }, + "30897": { + "title": "EEV-ssh-error (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb103-30897" + }, + "30898": { + "title": "Superheat temp. reference EEV (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb103-30898" + }, + "30899": { + "title": "Set point value EEV (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb103-30899" + }, + "30900": { + "title": "EEV PV (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb103-30900" + }, + "30901": { + "title": "EEV-te-error average open (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb103-30901" + }, + "30902": { + "title": "Degree of opening EEV (EB103)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb103-30902" + }, + "30903": { + "title": "Superheat reference EVI (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb103-30903" + }, + "30904": { + "title": "Superheat EVI (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb103-30904" + }, + "30905": { + "title": "EEV-ssh-error (EVI)(EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb103-30905" + }, + "30906": { + "title": "Superheat temp. reference EVI (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb103-30906" + }, + "30907": { + "title": "Set point value EVI (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb103-30907" + }, + "30908": { + "title": "EVI PV (EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb103-30908" + }, + "30909": { + "title": "EEV-te-error average open (EVI)(EB103)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb103-30909" + }, + "30910": { + "title": "Degree of opening EVI (EB103)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb103-30910" + }, + "30912": { + "title": "Fan speed (EB102)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "fan-speed-eb102-30912" + }, + "30913": { + "title": "Max fan speed (EB102)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "max-fan-speed-eb102-30913" + }, + "30914": { + "title": "Min fan speed (EB102)", + "factor": 1, + "unit": "rpm", + "size": "u16", + "name": "min-fan-speed-eb102-30914" + }, + "30917": { + "title": "Generated power heating (EB102", + "factor": 10, + "unit": "kW", + "size": "u16", + "name": "generated-power-heating-eb102-30917" + }, + "30919": { + "title": "Defrosting index (EB102)", + "factor": 1, + "size": "u16", + "name": "defrosting-index-eb102-30919" + }, + "30920": { + "title": "Superheat reference EEV (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-eev-eb102-30920" + }, + "30921": { + "title": "Superheat EEV (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-eev-eb102-30921" + }, + "30922": { + "title": "EEV-ssh-error (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-eb102-30922" + }, + "30923": { + "title": "Superheat temp. reference EEV (EB101)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-eev-eb101-30923" + }, + "30924": { + "title": "Set point value EEV (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-eev-eb102-30924" + }, + "30925": { + "title": "EEV PV (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-pv-eb102-30925" + }, + "30926": { + "title": "EEV-te-error average open (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-eb102-30926" + }, + "30927": { + "title": "Degree of opening EEV (EB102)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-eev-eb102-30927" + }, + "30928": { + "title": "Superheat reference EVI (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-reference-evi-eb102-30928" + }, + "30929": { + "title": "Superheat EVI (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-evi-eb102-30929" + }, + "30930": { + "title": "EEV-ssh-error (EVI)(EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-ssh-error-evi-eb102-30930" + }, + "30931": { + "title": "Superheat temp. reference EVI (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "superheat-temp-reference-evi-eb102-30931" + }, + "30932": { + "title": "Set point value EVI (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "set-point-value-evi-eb102-30932" + }, + "30933": { + "title": "EVI PV (EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evi-pv-eb102-30933" + }, + "30934": { + "title": "EEV-te-error average open (EVI)(EB102)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eev-te-error-average-open-evi-eb102-30934" + }, + "30935": { + "title": "Degree of opening EVI (EB102)", + "factor": 1, + "size": "u16", + "name": "degree-of-opening-evi-eb102-30935" + }, + "30961": { + "title": "Wind speed, weather forecast", + "factor": 10, + "size": "u16", + "name": "wind-speed-weather-forecast-30961" + }, + "30962": { + "title": "Humidity, weather forecast", + "factor": 10, + "unit": "%", + "size": "u16", + "name": "humidity-weather-forecast-30962" + }, + "30963": { + "title": "Temperature, weather forecast", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-weather-forecast-30963" + }, + "30964": { + "title": "Temperature, weather data (forecast)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-weather-data-forecast-30964" + }, + "40019": { + "title": "Limit DM", + "factor": 10, + "unit": "DM", + "size": "s16", + "min": -30000.0, + "max": 30000.0, + "default": 0.0, + "name": "limit-dm-40019", + "write": true + }, + "31017": { + "title": "Calculated supply climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "calculated-supply-climate-system-2-31017" + }, + "31018": { + "title": "Calculated supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "calculated-supply-climate-system-1-31018" + }, + "32196": { + "title": "Class 1 alarm", + "factor": 1, + "size": "u8", + "name": "class-1-alarm-32196" + }, + "31019": { + "title": "Frost protection status", + "factor": 1, + "size": "u16", + "name": "frost-protection-status-31019" + }, + "31020": { + "title": "Cooling status", + "factor": 1, + "size": "u8", + "name": "cooling-status-31020" + }, + "31026": { + "title": "Total run time additional heat", + "factor": 10, + "unit": "h", + "size": "s32", + "min": 0.0, + "max": 1000000.0, + "default": 0.0, + "name": "total-run-time-additional-heat-31026" + }, + "31028": { + "title": "Power internal additional heat", + "factor": 100, + "unit": "kW", + "size": "s16", + "name": "power-internal-additional-heat-31028" + }, + "31029": { + "title": "Priority", + "factor": 1, + "size": "u8", + "name": "priority-31029" + }, + "31030": { + "title": "Operating mode internal add. heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-internal-add-heat-31030" + }, + "31031": { + "title": "Oper. mode shunt climate system 4", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-4-31031" + }, + "31032": { + "title": "Oper. mode shunt climate system 3", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-3-31032" + }, + "31033": { + "title": "Oper. mode shunt climate system 2", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-2-31033" + }, + "31034": { + "title": "Oper. mode shunt climate system 1", + "factor": 1, + "size": "u8", + "name": "oper-mode-shunt-climate-system-1-31034" + }, + "31035": { + "title": "Operating. mode shunt controlled additional heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-shunt-controlled-additional-heat-31035" + }, + "31038": { + "title": "Fan mode 1", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-1-31038" + }, + "31039": { + "title": "Current hot water mode", + "factor": 1, + "size": "s8", + "name": "current-hot-water-mode-31039" + }, + "31042": { + "title": "Min frequency compressor", + "factor": 1, + "unit": "Hz", + "size": "s16", + "name": "min-frequency-compressor-31042" + }, + "31043": { + "title": "Max frequency compressor", + "factor": 1, + "unit": "Hz", + "size": "s16", + "name": "max-frequency-compressor-31043" + }, + "31047": { + "title": "Compressor frequency, current", + "factor": 10, + "unit": "Hz", + "size": "u16", + "name": "compressor-frequency-current-31047" + }, + "31048": { + "title": "Inverter temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "inverter-temperature-31048" + }, + "31049": { + "title": "Compressor power input", + "factor": 1, + "unit": "W", + "size": "u16", + "name": "compressor-power-input-31049" + }, + "31053": { + "title": "Current compressor", + "factor": 1, + "unit": "mA", + "size": "s16", + "name": "current-compressor-31053" + }, + "31054": { + "title": "Blocking cooling", + "factor": 1, + "size": "u8", + "name": "blocking-cooling-31054" + }, + "31055": { + "title": "External adjustment climate system 4", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-4-31055" + }, + "31056": { + "title": "External adjustment climate system 3", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-3-31056" + }, + "31057": { + "title": "External adjustment climate system 2", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-2-31057" + }, + "31058": { + "title": "External adjustment climate system 1", + "factor": 1, + "size": "u8", + "name": "external-adjustment-climate-system-1-31058" + }, + "31059": { + "title": "External blocking", + "factor": 1, + "size": "u8", + "name": "external-blocking-31059" + }, + "31060": { + "title": "Blocked", + "factor": 1, + "size": "u8", + "name": "blocked-31060" + }, + "31061": { + "title": "External blocking, active cooling (HPAC)", + "factor": 1, + "size": "u8", + "name": "external-blocking-active-cooling-hpac-31061" + }, + "31062": { + "title": "External blocking, passive cooling (HPAC)", + "factor": 1, + "size": "u8", + "name": "external-blocking-passive-cooling-hpac-31062" + }, + "31063": { + "title": "Step controlled add. heat blocking", + "factor": 1, + "size": "u8", + "name": "step-controlled-add-heat-blocking-31063" + }, + "31064": { + "title": "Hot water circulation (GP11)", + "factor": 1, + "size": "u8", + "name": "hot-water-circulation-gp11-31064" + }, + "31066": { + "title": "Compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u16", + "name": "compressor-frequency-31066" + }, + "31070": { + "title": "Total HW run time additional heat", + "factor": 10, + "unit": "h", + "size": "s32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "total-hw-run-time-additional-heat-31070" + }, + "31076": { + "title": "Compressor power input, average", + "factor": 1, + "unit": "W", + "size": "s16", + "name": "compressor-power-input-average-31076" + }, + "31079": { + "title": "More hot water status", + "factor": 1, + "size": "u8", + "name": "more-hot-water-status-31079" + }, + "31080": { + "title": "Relay status (HPAC)", + "factor": 1, + "size": "u8", + "name": "relay-status-hpac-31080" + }, + "40020": { + "title": "Holiday function status", + "factor": 1, + "size": "s8", + "name": "holiday-function-status-40020", + "write": true + }, + "31084": { + "title": "Compressor starter", + "factor": 1, + "size": "s32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-starter-31084" + }, + "31088": { + "title": "Total run time compressor", + "factor": 1, + "unit": "h", + "size": "s32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "total-run-time-compressor-31088" + }, + "31092": { + "title": "Total run time compressor hot water", + "factor": 1, + "unit": "h", + "size": "s32", + "min": -2147483648.0, + "max": 2147483647.0, + "default": 0.0, + "name": "total-run-time-compressor-hot-water-31092" + }, + "31095": { + "title": "Operating mode compressor", + "factor": 1, + "size": "u8", + "name": "operating-mode-compressor-31095" + }, + "31097": { + "title": "Operating mode heating medium pump", + "factor": 1, + "size": "u8", + "name": "operating-mode-heating-medium-pump-31097" + }, + "31099": { + "title": "Operating mode brine pump", + "factor": 1, + "size": "u8", + "name": "operating-mode-brine-pump-31099" + }, + "31101": { + "title": "Compressor status", + "factor": 1, + "size": "u8", + "name": "compressor-status-31101" + }, + "31103": { + "title": "Heating medium pump speed (GP1)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "heating-medium-pump-speed-gp1-31103" + }, + "31105": { + "title": "Brine pump speed (GP2)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "brine-pump-speed-gp2-31105" + }, + "31109": { + "title": "Docked compressors heating", + "factor": 1, + "size": "u8", + "name": "docked-compressors-heating-31109" + }, + "31110": { + "title": "Docked compressors hot water", + "factor": 1, + "size": "u8", + "name": "docked-compressors-hot-water-31110" + }, + "31111": { + "title": "Docked compressors pool 1", + "factor": 1, + "size": "u8", + "name": "docked-compressors-pool-1-31111" + }, + "32197": { + "title": "Reversing valve hot water (QN10)", + "factor": 1, + "size": "u8", + "name": "reversing-valve-hot-water-qn10-32197" + }, + "31112": { + "title": "Cooling activated (FLM 4)", + "factor": 1, + "size": "u8", + "name": "cooling-activated-flm-4-31112" + }, + "31113": { + "title": "Cooling activated (FLM 3)", + "factor": 1, + "size": "u8", + "name": "cooling-activated-flm-3-31113" + }, + "31114": { + "title": "Cooling activated (FLM 2)", + "factor": 1, + "size": "u8", + "name": "cooling-activated-flm-2-31114" + }, + "31115": { + "title": "Cooling activated (FLM 1)", + "factor": 1, + "size": "u8", + "name": "cooling-activated-flm-1-31115" + }, + "31118": { + "title": "Relay status, base board (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "relay-status-base-board-eb100-ep14-31118" + }, + "31120": { + "title": "Relay status, imm. heat. board (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "relay-status-imm-heat-board-eb100-ep14-31120" + }, + "31121": { + "title": "Current status", + "factor": 1, + "size": "u32", + "name": "current-status-31121" + }, + "31123": { + "title": "Functionality, heat pump (EP14)", + "factor": 1, + "size": "u32", + "name": "functionality-heat-pump-ep14-31123" + }, + "31125": { + "title": "Active heat pumps", + "factor": 1, + "size": "u16", + "name": "active-heat-pumps-31125" + }, + "31126": { + "title": "Functionality, heat pump (EP15)", + "factor": 1, + "size": "u32", + "name": "functionality-heat-pump-ep15-31126" + }, + "31130": { + "title": "Operating mode HW comfort", + "factor": 1, + "size": "u8", + "name": "operating-mode-hw-comfort-31130" + }, + "31131": { + "title": "Operating mode HW comfort additional heat", + "factor": 1, + "size": "u8", + "name": "operating-mode-hw-comfort-additional-heat-31131" + }, + "31132": { + "title": "Blocked", + "factor": 1, + "size": "u8", + "name": "blocked-31132" + }, + "31133": { + "title": "Blocked", + "factor": 1, + "size": "u8", + "name": "blocked-31133" + }, + "31134": { + "title": "Pool 2 (QN19)", + "factor": 1, + "size": "u8", + "name": "pool-2-qn19-31134" + }, + "31135": { + "title": "Pool 1 (QN19)", + "factor": 1, + "size": "u8", + "name": "pool-1-qn19-31135" + }, + "31136": { + "title": "Docked compressors pool 2", + "factor": 1, + "size": "u8", + "name": "docked-compressors-pool-2-31136" + }, + "31497": { + "title": "Version (EB100)", + "factor": 1, + "size": "u16", + "name": "version-eb100-31497" + }, + "31498": { + "title": "Heat pump type (EB100)", + "factor": 1, + "size": "u8", + "name": "heat-pump-type-eb100-31498" + }, + "31499": { + "title": "Compressor size (EB100)", + "factor": 1, + "size": "u8", + "name": "compressor-size-eb100-31499" + }, + "31516": { + "title": "Compressor, oper. time, total (EB100-EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-oper-time-total-eb100-ep15-31516" + }, + "31518": { + "title": "Compressor, oper. time, hot water (EB100-EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-oper-time-hot-water-eb100-ep15-31518" + }, + "31521": { + "title": "Return line (EB100-BT3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-eb100-bt3-31521" + }, + "31522": { + "title": "Brine in (EB100-BT10)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "brine-in-eb100-bt10-31522" + }, + "31523": { + "title": "Brine out (EB100-BT11)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "brine-out-eb100-bt11-31523" + }, + "31524": { + "title": "Condenser (EB100-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "condenser-eb100-bt2-31524" + }, + "31525": { + "title": "Discharge (EB100-BT14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "discharge-eb100-bt14-31525" + }, + "31526": { + "title": "Liquid line (EB100-BT15)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "liquid-line-eb100-bt15-31526" + }, + "31527": { + "title": "Suction gas (EB100-BT17)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "suction-gas-eb100-bt17-31527" + }, + "31528": { + "title": "Compressor sensor (EB100-BT29)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "compressor-sensor-eb100-bt29-31528" + }, + "31529": { + "title": "Low press (EB100-BP8)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-press-eb100-bp8-31529" + }, + "31530": { + "title": "Compressor status (EB100)", + "factor": 1, + "size": "u8", + "name": "compressor-status-eb100-31530" + }, + "31531": { + "title": "Compressor, time to start (EB100-EP14)", + "factor": 1, + "unit": "min", + "size": "u8", + "name": "compressor-time-to-start-eb100-ep14-31531" + }, + "31532": { + "title": "Relay status (EB100-EP14)", + "factor": 1, + "size": "u16", + "name": "relay-status-eb100-ep14-31532" + }, + "31533": { + "title": "Heating medium pump (EB100)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "heating-medium-pump-eb100-31533" + }, + "31534": { + "title": "Brine pump (EB100)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "brine-pump-eb100-31534" + }, + "31535": { + "title": "Compressor, number of starts (EB100-EP14)", + "factor": 1, + "size": "u32", + "name": "compressor-number-of-starts-eb100-ep14-31535" + }, + "31537": { + "title": "Compressor, oper. time, total (EB100-EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-oper-time-total-eb100-ep14-31537" + }, + "31539": { + "title": "Compressor, oper. time, hot water (EB100-EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "name": "compressor-oper-time-hot-water-eb100-ep14-31539" + }, + "31542": { + "title": "Compressor, requested (EB108-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb108-ep15-31542" + }, + "31543": { + "title": "Compressor, requested (EB108-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb108-ep14-31543" + }, + "31544": { + "title": "Compressor, requested (EB107-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb107-ep15-31544" + }, + "31545": { + "title": "Compressor, requested (EB107-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb107-ep14-31545" + }, + "31546": { + "title": "Compressor, requested (EB106-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb106-ep15-31546" + }, + "31547": { + "title": "Compressor, requested (EB106-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb106-ep14-31547" + }, + "31548": { + "title": "Compressor, requested (EB105-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb105-ep15-31548" + }, + "31549": { + "title": "Compressor, requested (EB105-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb105-ep14-31549" + }, + "31550": { + "title": "Compressor, requested (EB104-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb104-ep15-31550" + }, + "31551": { + "title": "Compressor, requested (EB104-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb104-ep14-31551" + }, + "31552": { + "title": "Compressor, requested (EB103-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb103-ep15-31552" + }, + "31553": { + "title": "Compressor, requested (EB103-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb103-ep14-31553" + }, + "31554": { + "title": "Compressor, requested (EB102-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb102-ep15-31554" + }, + "31555": { + "title": "Compressor, requested (EB102-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb102-ep14-31555" + }, + "31556": { + "title": "Compressor, requested (EB101-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb101-ep15-31556" + }, + "31557": { + "title": "Compressor, requested (EB101-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-requested-eb101-ep14-31557" + }, + "31562": { + "title": "Date, periodic hot water", + "factor": 1, + "size": "u16", + "name": "date-periodic-hot-water-31562" + }, + "32175": { + "title": "Blocked compressors", + "factor": 1, + "size": "u32", + "name": "blocked-compressors-32175" + }, + "40021": { + "title": "Cooling degree minutes", + "factor": 10, + "unit": "DM", + "size": "s16", + "min": -30000.0, + "max": 30000.0, + "default": 0.0, + "name": "cooling-degree-minutes-40021", + "write": true + }, + "31567": { + "title": "Calculated cooling supply climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "calculated-cooling-supply-climate-system-2-31567" + }, + "31568": { + "title": "Calculated cooling supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "calculated-cooling-supply-climate-system-1-31568" + }, + "31569": { + "title": "Status (ACS)", + "factor": 1, + "size": "u8", + "name": "status-acs-31569" + }, + "31570": { + "title": "Status, heating dumping (ACS)", + "factor": 1, + "size": "u8", + "name": "status-heating-dumping-acs-31570" + }, + "31571": { + "title": "Status, cooling dumping (ACS)", + "factor": 1, + "size": "u8", + "name": "status-cooling-dumping-acs-31571" + }, + "31572": { + "title": "Used compressors hot water", + "factor": 1, + "size": "u8", + "name": "used-compressors-hot-water-31572" + }, + "31573": { + "title": "Used compressors heating", + "factor": 1, + "size": "u8", + "name": "used-compressors-heating-31573" + }, + "31574": { + "title": "Used compressors pool 1", + "factor": 1, + "size": "u8", + "name": "used-compressors-pool-1-31574" + }, + "31575": { + "title": "Used compressors pool 2", + "factor": 1, + "size": "u8", + "name": "used-compressors-pool-2-31575" + }, + "31589": { + "title": "Used compressors cooling", + "factor": 1, + "size": "u8", + "name": "used-compressors-cooling-31589" + }, + "31624": { + "title": "(EB100-EP15-BT28)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eb100-ep15-bt28-31624" + }, + "31625": { + "title": "(EB100-EP15-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eb100-ep15-bt16-31625" + }, + "31626": { + "title": "(EB100-EP14-BT28)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eb100-ep14-bt28-31626" + }, + "31627": { + "title": "(EB100-EP14-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "eb100-ep14-bt16-31627" + }, + "31629": { + "title": "Docked compressors external control", + "factor": 1, + "size": "u8", + "name": "docked-compressors-external-control-31629" + }, + "31688": { + "title": "Bit register (EB100)", + "factor": 1, + "size": "u8", + "name": "bit-register-eb100-31688" + }, + "31689": { + "title": "Controlling hot water sensor (EB100-BT6)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "controlling-hot-water-sensor-eb100-bt6-31689" + }, + "31690": { + "title": "Display hot water sensor (EB100-BT7)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "display-hot-water-sensor-eb100-bt7-31690" + }, + "31691": { + "title": "Supply temperature sensor (EB100-BT2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-temperature-sensor-eb100-bt2-31691" + }, + "31692": { + "title": "Compressor status (EB100-EP15)", + "factor": 1, + "size": "u8", + "name": "compressor-status-eb100-ep15-31692" + }, + "31693": { + "title": "Compressor status (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "compressor-status-eb100-ep14-31693" + }, + "31695": { + "title": "Docked compressors cooling", + "factor": 1, + "size": "u8", + "name": "docked-compressors-cooling-31695" + }, + "31696": { + "title": "BP4, unprocessed (EB108-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb108-ep15-31696" + }, + "31698": { + "title": "Low pressure (EB108-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb108-ep15-bp8-31698" + }, + "31700": { + "title": "Prot. status (EB108-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb108-ep15-31700" + }, + "31701": { + "title": "Defrosting (EB108-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb108-ep15-31701" + }, + "31703": { + "title": "BP4, unprocessed (EB108-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb108-ep14-31703" + }, + "31708": { + "title": "Defrosting (EB108)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb108-31708" + }, + "31710": { + "title": "BP4, unprocessed (EB107-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb107-ep15-31710" + }, + "31712": { + "title": "Low pressure (EB107-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb107-ep15-bp8-31712" + }, + "31714": { + "title": "Prot. status (EB107-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb107-ep15-31714" + }, + "31715": { + "title": "Defrosting (EB107-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb107-ep15-31715" + }, + "31716": { + "title": "Power (EB107-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb107-ep15-31716" + }, + "31717": { + "title": "BP4, unprocessed (EB107-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb107-ep14-31717" + }, + "31722": { + "title": "Defrosting (EB107)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb107-31722" + }, + "31723": { + "title": "Power (EB107-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb107-ep14-31723" + }, + "31724": { + "title": "BP4, unprocessed (EB106-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb106-ep15-31724" + }, + "31726": { + "title": "Low pressure (EB106-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb106-ep15-bp8-31726" + }, + "31728": { + "title": "Prot. status (EB106-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb106-ep15-31728" + }, + "31729": { + "title": "Defrosting (EB106-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb106-ep15-31729" + }, + "31730": { + "title": "Power (EB106-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb106-ep15-31730" + }, + "31731": { + "title": "BP4, unprocessed (EB106-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb106-ep14-31731" + }, + "31736": { + "title": "Defrosting (EB106)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb106-31736" + }, + "31737": { + "title": "Power (EB106-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb106-ep14-31737" + }, + "31738": { + "title": "BP4, unprocessed (EB105-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb105-ep15-31738" + }, + "31740": { + "title": "Low pressure (EB105-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb105-ep15-bp8-31740" + }, + "31742": { + "title": "Prot. status (EB105-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb105-ep15-31742" + }, + "31743": { + "title": "Defrosting (EB105-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb105-ep15-31743" + }, + "31744": { + "title": "Power (EB105-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb105-ep15-31744" + }, + "31745": { + "title": "BP4, unprocessed (EB105-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb105-ep14-31745" + }, + "31750": { + "title": "Defrosting (EB105)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb105-31750" + }, + "31751": { + "title": "Power (EB105-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb105-ep15-31751" + }, + "31752": { + "title": "BP4, unprocessed (EB104-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb104-ep15-31752" + }, + "31754": { + "title": "Low pressure (EB104-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb104-ep15-bp8-31754" + }, + "31756": { + "title": "Prot. status (EB104-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb104-ep15-31756" + }, + "31768": { + "title": "Low pressure (EB103-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb103-ep15-bp8-31768" + }, + "31773": { + "title": "BP4, unprocessed (EB103-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb103-ep14-31773" + }, + "31778": { + "title": "Defrosting (EB103)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb103-31778" + }, + "31779": { + "title": "Power (EB103-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb103-ep14-31779" + }, + "31780": { + "title": "BP4, unprocessed (EB102-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb102-ep15-31780" + }, + "31782": { + "title": "Low pressure (EB102-EP15--BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb102-ep15-bp8-31782" + }, + "31784": { + "title": "Prot. status (EB102-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb102-ep15-31784" + }, + "31785": { + "title": "Defrosting (EB102-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb102-ep15-31785" + }, + "31786": { + "title": "Power (EB102-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb102-ep15-31786" + }, + "31787": { + "title": "BP4, unprocessed (EB102-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb102-ep14-31787" + }, + "31792": { + "title": "Defrosting (EB102)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb102-31792" + }, + "31793": { + "title": "Power (EB102-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb102-ep14-31793" + }, + "31794": { + "title": "BP4, unprocessed (EB101-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb101-ep15-31794" + }, + "31796": { + "title": "Low pressure (EB101-EP15-BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb101-ep15-bp8-31796" + }, + "31798": { + "title": "Prot. status (EB101-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb101-ep15-31798" + }, + "31799": { + "title": "Defrosting (EB101-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb101-ep15-31799" + }, + "31800": { + "title": "Power (EB101-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb101-ep15-31800" + }, + "31801": { + "title": "BP4, unprocessed (EB101-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb101-ep14-31801" + }, + "31806": { + "title": "Defrosting (EB101)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb101-31806" + }, + "31807": { + "title": "Power (EB101-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb101-ep14-31807" + }, + "31808": { + "title": "BP4, unprocessed (EB100-EP15)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb100-ep15-31808" + }, + "31809": { + "title": "Pressure sensor, condenser (EB100-EP15-BP4)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "pressure-sensor-condenser-eb100-ep15-bp4-31809" + }, + "31810": { + "title": "Low pressure (EB100-EP15-BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb100-ep15-bp8-31810" + }, + "31812": { + "title": "Prot. status (EB100-EP15)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb100-ep15-31812" + }, + "31813": { + "title": "Defrosting (EB100-EP15)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb100-ep15-31813" + }, + "31814": { + "title": "Power (EB100-EP15)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb100-ep15-31814" + }, + "31815": { + "title": "BP4, unprocessed (EB100-EP14)", + "factor": 1, + "size": "s16", + "name": "bp4-unprocessed-eb100-ep14-31815" + }, + "31816": { + "title": "Pressure sensor, condenser (EB100-EP14-BP4)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "pressure-sensor-condenser-eb100-ep14-bp4-31816" + }, + "31817": { + "title": "Low pressure (EB100-EP14-BP8)", + "factor": 10, + "unit": "bar", + "size": "s16", + "name": "low-pressure-eb100-ep14-bp8-31817" + }, + "31819": { + "title": "Prot. status (EB100-EP14)", + "factor": 1, + "size": "u16", + "name": "prot-status-eb100-ep14-31819" + }, + "31820": { + "title": "Defrosting (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "defrosting-eb100-ep14-31820" + }, + "31821": { + "title": "Power (EB100-EP14)", + "factor": 1, + "unit": "kW", + "size": "u8", + "name": "power-eb100-ep14-31821" + }, + "31824": { + "title": "Climate system 4", + "factor": 1, + "size": "u8", + "name": "climate-system-4-31824" + }, + "31825": { + "title": "Climate system 3", + "factor": 1, + "size": "u8", + "name": "climate-system-3-31825" + }, + "31826": { + "title": "Climate system 2", + "factor": 1, + "size": "u8", + "name": "climate-system-2-31826" + }, + "31827": { + "title": "Climate system 1 (HMP)", + "factor": 1, + "size": "u8", + "name": "climate-system-1-hmp-31827" + }, + "31828": { + "title": "Pool 2 pump status", + "factor": 1, + "size": "u8", + "name": "pool-2-pump-status-31828" + }, + "31829": { + "title": "Pool 1 pump status", + "factor": 1, + "size": "u8", + "name": "pool-1-pump-status-31829" + }, + "31831": { + "title": "ACS EQ1-QN12", + "factor": 1, + "size": "u8", + "name": "acs-eq1-qn12-31831" + }, + "31832": { + "title": "ACS EQ1-GP20", + "factor": 1, + "size": "u8", + "name": "acs-eq1-gp20-31832" + }, + "31833": { + "title": "Passive cooling shunt", + "factor": 1, + "size": "u8", + "name": "passive-cooling-shunt-31833" + }, + "31834": { + "title": "Passive cooling pump (GP13)", + "factor": 1, + "size": "u8", + "name": "passive-cooling-pump-gp13-31834" + }, + "31836": { + "title": "Oper. mode groundwater pump", + "factor": 1, + "size": "u8", + "name": "oper-mode-groundwater-pump-31836" + }, + "31838": { + "title": "Alarm number (EB100-EP15)", + "factor": 1, + "size": "u16", + "name": "alarm-number-eb100-ep15-31838" + }, + "31839": { + "title": "Alarm number (EB100-EP14)", + "factor": 1, + "size": "u16", + "name": "alarm-number-eb100-ep14-31839" + }, + "31840": { + "title": "Requested compressor frequency (EB108-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb108-ep15-31840" + }, + "31842": { + "title": "Requested compressor frequency (EB107-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb107-ep15-31842" + }, + "31844": { + "title": "Requested compressor frequency (EB106-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb106-ep15-31844" + }, + "31846": { + "title": "Requested compressor frequency (EB105-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb105-ep15-31846" + }, + "31848": { + "title": "Requested compressor frequency (EB104-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb104-ep15-31848" + }, + "31850": { + "title": "Requested compressor frequency (EB103-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb103-ep15-31850" + }, + "31852": { + "title": "Requested compressor frequency (EB102-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb102-ep15-31852" + }, + "31854": { + "title": "Requested compressor frequency (EB101-EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-eb101-ep15-31854" + }, + "31856": { + "title": "Requested compressor frequency (EP15)", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-ep15-31856" + }, + "31857": { + "title": "Requested compressor frequency", + "factor": 1, + "unit": "Hz", + "size": "u8", + "name": "requested-compressor-frequency-31857" + }, + "32411": { + "title": "Operating mode, shunt controlled brine (QN41)", + "factor": 1, + "size": "u8", + "name": "operating-mode-shunt-controlled-brine-qn41-32411" + }, + "31906": { + "title": "Low press. sensor, unprocessed (EB100-EP15)", + "factor": 1, + "size": "s16", + "name": "low-press-sensor-unprocessed-eb100-ep15-31906" + }, + "31907": { + "title": "Current sensor (EB100-EP15)", + "factor": 10, + "unit": "A", + "size": "s16", + "name": "current-sensor-eb100-ep15-31907" + }, + "31909": { + "title": "Low press. sensor, unprocessed (EB100-EP14)", + "factor": 1, + "size": "s16", + "name": "low-press-sensor-unprocessed-eb100-ep14-31909" + }, + "31910": { + "title": "Current sensor (EB100-EP14)", + "factor": 10, + "unit": "A", + "size": "s16", + "name": "current-sensor-eb100-ep14-31910" + }, + "31912": { + "title": "Operating mode (SG Ready)", + "factor": 1, + "size": "u8", + "name": "operating-mode-sg-ready-31912" + }, + "31913": { + "title": "SG ready, input A", + "factor": 1, + "size": "u8", + "name": "sg-ready-input-a-31913" + }, + "31914": { + "title": "SG ready, input B", + "factor": 1, + "size": "u8", + "name": "sg-ready-input-b-31914" + }, + "31916": { + "title": "Hot water comfort mode (SPA)", + "factor": 1, + "size": "s8", + "name": "hot-water-comfort-mode-spa-31916" + }, + "31917": { + "title": "Pool offset (SPA)", + "factor": 1, + "size": "s8", + "name": "pool-offset-spa-31917" + }, + "31918": { + "title": "Cooling offset (SPA)", + "factor": 1, + "size": "s8", + "name": "cooling-offset-spa-31918" + }, + "31919": { + "title": "Operating mode (Smart Price Adaption)", + "factor": 1, + "size": "u8", + "name": "operating-mode-smart-price-adaption-31919" + }, + "31920": { + "title": "Brine pump dT current", + "factor": 10, + "size": "s16", + "name": "brine-pump-dt-current-31920" + }, + "31921": { + "title": "Brine pump dT set point value", + "factor": 10, + "size": "s16", + "name": "brine-pump-dt-set-point-value-31921" + }, + "31970": { + "title": "Evaporator 2 (EB100-EP15-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-2-eb100-ep15-bt16-31970" + }, + "31971": { + "title": "Temperature, inverter (EB100-EP15)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-inverter-eb100-ep15-31971" + }, + "31972": { + "title": "fan speed (EB100-EP15)", + "factor": 1, + "size": "u8", + "name": "fan-speed-eb100-ep15-31972" + }, + "31973": { + "title": "Evaporator 2 (EB100-EP14-BT16)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-2-eb100-ep14-bt16-31973" + }, + "31974": { + "title": "Temperature, inverter (EB100-EP14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "temperature-inverter-eb100-ep14-31974" + }, + "31975": { + "title": "fan speed (EB100-EP14)", + "factor": 1, + "size": "u8", + "name": "fan-speed-eb100-ep14-31975" + }, + "31976": { + "title": "Alarm number", + "factor": 1, + "size": "s16", + "name": "alarm-number-31976" + }, + "40023": { + "title": "Reset alarm", + "factor": 1, + "size": "u8", + "name": "reset-alarm-40023", + "write": true + }, + "31977": { + "title": "Non module-specific alarm numbers", + "factor": 1, + "size": "s16", + "name": "non-module-specific-alarm-numbers-31977" + }, + "40026": { + "title": "Heating curve climate system 2", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 15.0, + "default": 9.0, + "name": "heating-curve-climate-system-2-40026", + "write": true + }, + "40027": { + "title": "Heating curve climate system 1", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 15.0, + "default": 9.0, + "name": "heating-curve-climate-system-1-40027", + "write": true + }, + "40030": { + "title": "Heating offset climate system 2", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "heating-offset-climate-system-2-40030", + "write": true + }, + "40031": { + "title": "Heating offset climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "heating-offset-climate-system-1-40031", + "write": true + }, + "40034": { + "title": "Min supply climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 800.0, + "default": 200.0, + "name": "min-supply-climate-system-2-40034", + "write": true + }, + "40035": { + "title": "Min supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 800.0, + "default": 200.0, + "name": "min-supply-climate-system-1-40035", + "write": true + }, + "40038": { + "title": "Max supply climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 800.0, + "default": 600.0, + "name": "max-supply-climate-system-2-40038", + "write": true + }, + "40039": { + "title": "Max supply climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 800.0, + "default": 600.0, + "name": "max-supply-climate-system-1-40039", + "write": true + }, + "40040": { + "title": "Own curve, heating P7", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 15.0, + "name": "own-curve-heating-p7-40040", + "write": true + }, + "40041": { + "title": "Own curve, heating P6", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 15.0, + "name": "own-curve-heating-p6-40041", + "write": true + }, + "40042": { + "title": "Own curve, heating P5", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 26.0, + "name": "own-curve-heating-p5-40042", + "write": true + }, + "40043": { + "title": "Own curve, heating P4", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 32.0, + "name": "own-curve-heating-p4-40043", + "write": true + }, + "40044": { + "title": "Own curve, heating P3", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 35.0, + "name": "own-curve-heating-p3-40044", + "write": true + }, + "40045": { + "title": "Own curve, heating P2", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 40.0, + "name": "own-curve-heating-p2-40045", + "write": true + }, + "40046": { + "title": "Own curve, heating P1", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 80.0, + "default": 45.0, + "name": "own-curve-heating-p1-40046", + "write": true + }, + "40047": { + "title": "Point offset outdoor temperature", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -40.0, + "max": 30.0, + "default": 0.0, + "name": "point-offset-outdoor-temperature-40047", + "write": true + }, + "40048": { + "title": "Point offset", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "point-offset-40048", + "write": true + }, + "40051": { + "title": "External adjustment climate system 2", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-2-40051", + "write": true + }, + "40052": { + "title": "External adjustment climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-1-40052", + "write": true + }, + "40055": { + "title": "External adjustment with room sensor climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-2-40055", + "write": true + }, + "40056": { + "title": "External adjustment with room sensor climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-1-40056", + "write": true + }, + "40057": { + "title": "Hot water demand mode", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 4.0, + "default": 1.0, + "name": "hot-water-demand-mode-40057", + "write": true + }, + "40059": { + "title": "Start temperature HW high temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 530.0, + "name": "start-temperature-hw-high-temperature-40059", + "write": true + }, + "40060": { + "title": "Start temperature HW normal temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 600.0, + "default": 480.0, + "name": "start-temperature-hw-normal-temperature-40060", + "write": true + }, + "40061": { + "title": "Start temperature HW low temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 550.0, + "default": 450.0, + "name": "start-temperature-hw-low-temperature-40061", + "write": true + }, + "40062": { + "title": "Stop temperature HW periodic increase", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 550.0, + "max": 700.0, + "default": 550.0, + "name": "stop-temperature-hw-periodic-increase-40062", + "write": true + }, + "40063": { + "title": "Stop temperature HW high temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 700.0, + "default": 550.0, + "name": "stop-temperature-hw-high-temperature-40063", + "write": true + }, + "40064": { + "title": "Stop temperature HW normal temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 650.0, + "default": 510.0, + "name": "stop-temperature-hw-normal-temperature-40064", + "write": true + }, + "40065": { + "title": "Stop temperature HW low temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 600.0, + "default": 480.0, + "name": "stop-temperature-hw-low-temperature-40065", + "write": true + }, + "40066": { + "title": "Periodic hot water", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "periodic-hot-water-40066", + "write": true + }, + "40067": { + "title": "Periodic hot water interval", + "factor": 1, + "unit": "days", + "size": "s8", + "min": 1.0, + "max": 90.0, + "default": 7.0, + "name": "periodic-hot-water-interval-40067", + "write": true + }, + "40068": { + "title": "Start time periodic hot water", + "factor": 1, + "size": "u16", + "name": "start-time-periodic-hot-water-40068", + "write": true + }, + "42755": { + "title": "Hot water circulation", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hot-water-circulation-42755", + "write": true + }, + "40092": { + "title": "Language", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 24.0, + "default": 0.0, + "name": "language-40092", + "write": true + }, + "40093": { + "title": "Period time hot water", + "factor": 1, + "unit": "min", + "size": "u8", + "min": 0.0, + "max": 180.0, + "default": 30.0, + "name": "period-time-hot-water-40093", + "write": true + }, + "40094": { + "title": "Period time heating", + "factor": 1, + "unit": "min", + "size": "u8", + "min": 0.0, + "max": 180.0, + "default": 30.0, + "name": "period-time-heating-40094", + "write": true + }, + "42744": { + "title": "Operating mode", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 0.0, + "name": "operating-mode-42744", + "write": true + }, + "40096": { + "title": "Operating mode heating medium pump", + "factor": 1, + "size": "u8", + "min": 10.0, + "max": 40.0, + "default": 40.0, + "name": "operating-mode-heating-medium-pump-40096", + "write": true + }, + "40097": { + "title": "Operating mode brine pump", + "factor": 1, + "size": "u8", + "min": 10.0, + "max": 30.0, + "default": 10.0, + "name": "operating-mode-brine-pump-40097", + "write": true + }, + "45001": { + "title": "Activate forced control", + "factor": 1, + "size": "u8", + "name": "activate-forced-control-45001", + "write": true + }, + "40098": { + "title": "DM start heating", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": -1000.0, + "max": -30.0, + "default": -60.0, + "name": "dm-start-heating-40098", + "write": true + }, + "40101": { + "title": "DM between additional heat step", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 10.0, + "max": 1000.0, + "default": 100.0, + "name": "dm-between-additional-heat-step-40101", + "write": true + }, + "40103": { + "title": "Max. internal additional heat", + "factor": 100, + "unit": "kW", + "size": "s16", + "min": 0.0, + "max": 4500.0, + "default": 700.0, + "name": "max-internal-additional-heat-40103", + "write": true + }, + "40104": { + "title": "Fuse", + "factor": 1, + "unit": "A", + "size": "u16", + "min": 1.0, + "max": 400.0, + "default": 16.0, + "name": "fuse-40104", + "write": true + }, + "40121": { + "title": "Floor drying", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "floor-drying-40121", + "write": true + }, + "40122": { + "title": "Floor drying period 7", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-7-40122", + "write": true + }, + "40123": { + "title": "Floor drying period 6", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-6-40123", + "write": true + }, + "40124": { + "title": "Floor drying period 5", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-5-40124", + "write": true + }, + "40125": { + "title": "Floor drying period 4", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 3.0, + "name": "floor-drying-period-4-40125", + "write": true + }, + "40126": { + "title": "Floor drying period 3", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-3-40126", + "write": true + }, + "40127": { + "title": "Floor drying period 2", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-2-40127", + "write": true + }, + "40128": { + "title": "Floor drying period 1", + "factor": 1, + "unit": "days", + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 2.0, + "name": "floor-drying-period-1-40128", + "write": true + }, + "40129": { + "title": "Floor drying temp. 7", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 20.0, + "name": "floor-drying-temp-7-40129", + "write": true + }, + "40130": { + "title": "Floor drying temp. 6", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 30.0, + "name": "floor-drying-temp-6-40130", + "write": true + }, + "40131": { + "title": "Floor drying temp. 5", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 40.0, + "name": "floor-drying-temp-5-40131", + "write": true + }, + "40132": { + "title": "Floor drying temp. 4", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 45.0, + "name": "floor-drying-temp-4-40132", + "write": true + }, + "40133": { + "title": "Floor drying temp. 3", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 40.0, + "name": "floor-drying-temp-3-40133", + "write": true + }, + "40134": { + "title": "Floor drying temp. 2", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 30.0, + "name": "floor-drying-temp-2-40134", + "write": true + }, + "40135": { + "title": "Floor drying temp. 1", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 15.0, + "max": 70.0, + "default": 20.0, + "name": "floor-drying-temp-1-40135", + "write": true + }, + "31978": { + "title": "Floor drying ongoing time.", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 0.0, + "name": "floor-drying-ongoing-time-31978" + }, + "40141": { + "title": "Dimensioned outdoor temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -400.0, + "max": 200.0, + "default": -180.0, + "name": "dimensioned-outdoor-temperature-40141", + "write": true + }, + "40142": { + "title": "Delta T for DOT", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 100.0, + "name": "delta-t-for-dot-40142", + "write": true + }, + "40143": { + "title": "Climate system 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-2-40143", + "write": true + }, + "40144": { + "title": "Climate system 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-3-40144", + "write": true + }, + "40145": { + "title": "Climate system 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-4-40145", + "write": true + }, + "40148": { + "title": "Climate system 2 shunt amplification", + "factor": 10, + "size": "s8", + "min": 1.0, + "max": 100.0, + "default": 10.0, + "name": "climate-system-2-shunt-amplification-40148", + "write": true + }, + "40151": { + "title": "Climate system 2 shunt wait time", + "factor": 1, + "unit": "s", + "size": "s16", + "min": 10.0, + "max": 300.0, + "default": 30.0, + "name": "climate-system-2-shunt-wait-time-40151", + "write": true + }, + "40154": { + "title": "Shunt controlled additional heat", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "shunt-controlled-additional-heat-40154", + "write": true + }, + "40158": { + "title": "Wait time shunt, shunt controlled additional heat", + "factor": 1, + "unit": "s", + "size": "s16", + "min": 10.0, + "max": 300.0, + "default": 30.0, + "name": "wait-time-shunt-shunt-controlled-additional-heat-40158", + "write": true + }, + "40159": { + "title": "Step controlled additional heat accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "step-controlled-additional-heat-accessory-40159", + "write": true + }, + "40163": { + "title": "Ground water pump accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ground-water-pump-accessory-40163", + "write": true + }, + "41981": { + "title": "PCI accessories", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pci-accessories-41981", + "write": true + }, + "40166": { + "title": "Waiting time cooling/heating", + "factor": 1, + "unit": "h", + "size": "s8", + "min": 0.0, + "max": 48.0, + "default": 2.0, + "name": "waiting-time-cooling-heating-40166", + "write": true + }, + "40167": { + "title": "Heating start at under temp.", + "factor": 10, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 100.0, + "default": 10.0, + "name": "heating-start-at-under-temp-40167", + "write": true + }, + "40168": { + "title": "Cooling start at over temp.", + "factor": 10, + "unit": "\u00b0C", + "size": "s8", + "min": 5.0, + "max": 100.0, + "default": 30.0, + "name": "cooling-start-at-over-temp-40168", + "write": true + }, + "40169": { + "title": "Cooling shunt amplification", + "factor": 10, + "size": "s8", + "min": 1.0, + "max": 100.0, + "default": 10.0, + "name": "cooling-shunt-amplification-40169", + "write": true + }, + "40170": { + "title": "Cooling shunt waiting time", + "factor": 1, + "unit": "s", + "size": "s16", + "min": 10.0, + "max": 300.0, + "default": 30.0, + "name": "cooling-shunt-waiting-time-40170", + "write": true + }, + "40171": { + "title": "Cooling with room sensors", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 41.0, + "default": 0.0, + "name": "cooling-with-room-sensors-40171", + "write": true + }, + "40173": { + "title": "Start passive cooling DM", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 10.0, + "max": 500.0, + "default": 30.0, + "name": "start-passive-cooling-dm-40173", + "write": true + }, + "40174": { + "title": "Start active cooling DM", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 10.0, + "max": 300.0, + "default": 90.0, + "name": "start-active-cooling-dm-40174", + "write": true + }, + "42745": { + "title": "Changes have been made", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "changes-have-been-made-42745", + "write": true + }, + "40181": { + "title": "Permit additional heat, heating", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "permit-additional-heat-heating-40181", + "write": true + }, + "40182": { + "title": "Permit heating", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "permit-heating-40182", + "write": true + }, + "40183": { + "title": "Permit cooling", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "permit-cooling-40183", + "write": true + }, + "40185": { + "title": "Auto mode, stop temperature for heating", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -200.0, + "max": 400.0, + "default": 170.0, + "name": "auto-mode-stop-temperature-for-heating-40185", + "write": true + }, + "40186": { + "title": "Auto mode, additional heat stop temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -250.0, + "max": 400.0, + "default": 50.0, + "name": "auto-mode-additional-heat-stop-temperature-40186", + "write": true + }, + "40187": { + "title": "Auto mode filter time", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 0.0, + "max": 48.0, + "default": 24.0, + "name": "auto-mode-filter-time-40187", + "write": true + }, + "40188": { + "title": "Max difference supply, compressor", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 100.0, + "name": "max-difference-supply-compressor-40188", + "write": true + }, + "40189": { + "title": "Max difference supply, additional heat", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 240.0, + "default": 30.0, + "name": "max-difference-supply-additional-heat-40189", + "write": true + }, + "40190": { + "title": "Low brine alarm auto reset", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "low-brine-alarm-auto-reset-40190", + "write": true + }, + "40191": { + "title": "Low brine out alarm temperature (EP14)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -120.0, + "max": 150.0, + "default": -80.0, + "name": "low-brine-out-alarm-temperature-ep14-40191", + "write": true + }, + "40192": { + "title": "High brine in alarm active", + "factor": 1, + "size": "u8", + "name": "high-brine-in-alarm-active-40192", + "write": true + }, + "40193": { + "title": "High brine in alarm temperature", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 100.0, + "max": 350.0, + "default": 350.0, + "name": "high-brine-in-alarm-temperature-40193", + "write": true + }, + "40195": { + "title": "Time format", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "time-format-40195", + "write": true + }, + "40196": { + "title": "Hot water permitted", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hot-water-permitted-40196", + "write": true + }, + "40197": { + "title": "Alarm action, lower room temperature", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "alarm-action-lower-room-temperature-40197", + "write": true + }, + "40198": { + "title": "Alarm action lower HW temperature", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "alarm-action-lower-hw-temperature-40198", + "write": true + }, + "40199": { + "title": "Auxiliary operation on alarm", + "factor": 1, + "size": "u8", + "name": "auxiliary-operation-on-alarm-40199", + "write": true + }, + "40200": { + "title": "Use room sensor climate system 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-4-40200", + "write": true + }, + "40201": { + "title": "Use room sensor climate system 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-3-40201", + "write": true + }, + "40202": { + "title": "Use room sensor climate system 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-2-40202", + "write": true + }, + "40203": { + "title": "Use room sensor climate system 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-1-40203", + "write": true + }, + "40204": { + "title": "Room sensor set point value climate system 4", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-4-40204", + "write": true + }, + "40205": { + "title": "Room sensor set point value climate system 3", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-3-40205", + "write": true + }, + "40206": { + "title": "Room sensor set point value climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-2-40206", + "write": true + }, + "40207": { + "title": "Room sensor set point value climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-1-40207", + "write": true + }, + "40208": { + "title": "Room sensor factor climate system 4", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-4-40208", + "write": true + }, + "40209": { + "title": "Room sensor factor climate system 3", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-3-40209", + "write": true + }, + "40210": { + "title": "Room sensor factor climate system 2", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-2-40210", + "write": true + }, + "40211": { + "title": "Room sensor factor climate system 1", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-1-40211", + "write": true + }, + "40212": { + "title": "Input AUX5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux5-40212", + "write": true + }, + "40213": { + "title": "Input AUX4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux4-40213", + "write": true + }, + "40214": { + "title": "Input AUX3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux3-40214", + "write": true + }, + "40215": { + "title": "Input AUX2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux2-40215", + "write": true + }, + "40216": { + "title": "Input AUX1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux1-40216", + "write": true + }, + "40217": { + "title": "Output AUX1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 30.0, + "default": 0.0, + "name": "output-aux1-40217", + "write": true + }, + "40218": { + "title": "Speed of circulation pump for hot water", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-of-circulation-pump-for-hot-water-40218", + "write": true + }, + "40219": { + "title": "Speed of circulation pump for heating", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-of-circulation-pump-for-heating-40219", + "write": true + }, + "40220": { + "title": "Speed, heating medium pump for pool", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-heating-medium-pump-for-pool-40220", + "write": true + }, + "40221": { + "title": "Speed heating medium pump waiting mode", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 30.0, + "name": "speed-heating-medium-pump-waiting-mode-40221", + "write": true + }, + "40222": { + "title": "Speed of circulation pump passive cooling (EP14)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-of-circulation-pump-passive-cooling-ep14-40222", + "write": true + }, + "40223": { + "title": "Speed, brine pump", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "speed-brine-pump-40223", + "write": true + }, + "40224": { + "title": "Preset flow setting for climate system", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 3.0, + "default": 1.0, + "name": "preset-flow-setting-for-climate-system-40224", + "write": true + }, + "40226": { + "title": "More hot water (Number of minutes)", + "factor": 1, + "size": "u16", + "name": "more-hot-water-number-of-minutes-40226", + "write": true + }, + "40238": { + "title": "Oper. mode", + "factor": 1, + "size": "u8", + "name": "oper-mode-40238", + "write": true + }, + "40676": { + "title": "FLM 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "flm-4-40676", + "write": true + }, + "40677": { + "title": "FLM 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "flm-3-40677", + "write": true + }, + "40678": { + "title": "FLM 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "flm-2-40678", + "write": true + }, + "40679": { + "title": "FLM 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "flm-1-40679", + "write": true + }, + "40680": { + "title": "DM diff. start additional heat", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-diff-start-additional-heat-40680", + "write": true + }, + "40682": { + "title": "Cooling heat sensor set point value", + "factor": 10, + "size": "s16", + "min": 50.0, + "max": 400.0, + "default": 210.0, + "name": "cooling-heat-sensor-set-point-value-40682", + "write": true + }, + "40685": { + "title": "Pool 2 accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pool-2-accessory-40685", + "write": true + }, + "40686": { + "title": "Pool 1 accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pool-1-accessory-40686", + "write": true + }, + "40695": { + "title": "Hot water comfort", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hot-water-comfort-40695", + "write": true + }, + "40696": { + "title": "Manual heating medium pump speed", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "manual-heating-medium-pump-speed-40696", + "write": true + }, + "40698": { + "title": "More hot water", + "factor": 1, + "size": "s8", + "name": "more-hot-water-40698", + "write": true + }, + "40704": { + "title": "Start diff. DM, step-controlled add. heat", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 0.0, + "max": 2000.0, + "default": 400.0, + "name": "start-diff-dm-step-controlled-add-heat-40704", + "write": true + }, + "40706": { + "title": "HW comfort shunt on/off", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hw-comfort-shunt-on-off-40706", + "write": true + }, + "40711": { + "title": "HW comfort additional heat", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hw-comfort-additional-heat-40711", + "write": true + }, + "40712": { + "title": "Supp. air curve SAM, outd. temp. (T3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -400.0, + "max": 200.0, + "default": 150.0, + "name": "supp-air-curve-sam-outd-temp-t3-40712", + "write": true + }, + "40713": { + "title": "Supp. air curve SAM, outd. temp. (T2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -390.0, + "max": 190.0, + "default": 0.0, + "name": "supp-air-curve-sam-outd-temp-t2-40713", + "write": true + }, + "40714": { + "title": "Supp. air curve SAM, outd. temp. (T1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -400.0, + "max": 200.0, + "default": -150.0, + "name": "supp-air-curve-sam-outd-temp-t1-40714", + "write": true + }, + "40715": { + "title": "Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 160.0, + "max": 220.0, + "default": 180.0, + "name": "supp-air-curve-sam-desired-supp-air-temp-at-given-outd-temp-t3-40715", + "write": true + }, + "40716": { + "title": "Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 160.0, + "max": 220.0, + "default": 180.0, + "name": "supp-air-curve-sam-desired-supp-air-temp-at-given-outd-temp-t2-40716", + "write": true + }, + "40717": { + "title": "Supp. air curve SAM, desired supp. air temp. at given outd. temp. (T1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 160.0, + "max": 220.0, + "default": 180.0, + "name": "supp-air-curve-sam-desired-supp-air-temp-at-given-outd-temp-t1-40717", + "write": true + }, + "40720": { + "title": "Min. supply temp. cooling climate system 2", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 30.0, + "default": 18.0, + "name": "min-supply-temp-cooling-climate-system-2-40720", + "write": true + }, + "40721": { + "title": "Min. supply temp. cooling climate system 1", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 30.0, + "default": 18.0, + "name": "min-supply-temp-cooling-climate-system-1-40721", + "write": true + }, + "40722": { + "title": "Own curve, cooling P3", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 40.0, + "default": 20.0, + "name": "own-curve-cooling-p3-40722", + "write": true + }, + "40723": { + "title": "Own curve, cooling P5", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 40.0, + "default": 20.0, + "name": "own-curve-cooling-p5-40723", + "write": true + }, + "40726": { + "title": "Cooling connected, climate system 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "cooling-connected-climate-system-2-40726", + "write": true + }, + "40727": { + "title": "Cooling connected, climate system 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "cooling-connected-climate-system-1-40727", + "write": true + }, + "40732": { + "title": "ACS", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "acs-40732", + "write": true + }, + "40741": { + "title": "Max speed, regulator, charge/heating medium pump (EB100)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 50.0, + "max": 100.0, + "default": 100.0, + "name": "max-speed-regulator-charge-heating-medium-pump-eb100-40741", + "write": true + }, + "45269": { + "title": "Shunted brine, accessory", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "shunted-brine-accessory-45269", + "write": true + }, + "45272": { + "title": "Shunted brine max. temp.", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 35.0, + "default": 20.0, + "name": "shunted-brine-max-temp-45272", + "write": true + }, + "40759": { + "title": "Additional heat after reversing valve", + "factor": 1, + "size": "u8", + "name": "additional-heat-after-reversing-valve-40759", + "write": true + }, + "40761": { + "title": "Heating (SG Ready)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-sg-ready-40761", + "write": true + }, + "40767": { + "title": "Set compressor frequency, cooling", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 1.0, + "name": "set-compressor-frequency-cooling-40767", + "write": true + }, + "40768": { + "title": "Input AUX6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux6-40768", + "write": true + }, + "40843": { + "title": "Speed, circulation pump, standby mode (EB100)", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "speed-circulation-pump-standby-mode-eb100-40843", + "write": true + }, + "40844": { + "title": "Activated (Smart Price Adaption)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "activated-smart-price-adaption-40844", + "write": true + }, + "40850": { + "title": "(SPA), cooling activated", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "spa-cooling-activated-40850", + "write": true + }, + "40852": { + "title": "(SPA), area", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 255.0, + "default": 255.0, + "name": "spa-area-40852", + "write": true + }, + "40853": { + "title": "Automatic speed heating medium pump, hot water", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "automatic-speed-heating-medium-pump-hot-water-40853", + "write": true + }, + "40854": { + "title": "Automatic speed heating medium pump, heating", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "automatic-speed-heating-medium-pump-heating-40854", + "write": true + }, + "40855": { + "title": "Automatic speed heating medium pump, pool", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "automatic-speed-heating-medium-pump-pool-40855", + "write": true + }, + "40859": { + "title": "Maximum speed of circulation pump for heating", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 50.0, + "max": 100.0, + "default": 100.0, + "name": "maximum-speed-of-circulation-pump-for-heating-40859", + "write": true + }, + "40860": { + "title": "Speed, brine pump, passive cooling mode", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 75.0, + "name": "speed-brine-pump-passive-cooling-mode-40860", + "write": true + }, + "40894": { + "title": "External adjustment climate system 8", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-8-40894", + "write": true + }, + "40895": { + "title": "External adjustment climate system 7", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-7-40895", + "write": true + }, + "40896": { + "title": "External adjustment climate system 6", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-6-40896", + "write": true + }, + "40897": { + "title": "External adjustment climate system 5", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-climate-system-5-40897", + "write": true + }, + "40898": { + "title": "External adjustment with room sensor climate system 8", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-8-40898", + "write": true + }, + "40899": { + "title": "External adjustment with room sensor climate system 7", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-7-40899", + "write": true + }, + "40900": { + "title": "External adjustment with room sensor climate system 6", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-6-40900", + "write": true + }, + "40901": { + "title": "External adjustment with room sensor climate system 5", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-climate-system-5-40901", + "write": true + }, + "40904": { + "title": "Initiate inverter", + "factor": 1, + "size": "u8", + "name": "initiate-inverter-40904", + "write": true + }, + "40905": { + "title": "Force initiated inverter", + "factor": 1, + "size": "u8", + "name": "force-initiated-inverter-40905", + "write": true + }, + "40906": { + "title": "Climate system 5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-5-40906", + "write": true + }, + "40907": { + "title": "Climate system 6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-6-40907", + "write": true + }, + "40908": { + "title": "Climate system 7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-7-40908", + "write": true + }, + "40909": { + "title": "Climate system 8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "climate-system-8-40909", + "write": true + }, + "40932": { + "title": "Heating connected, climate system 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-connected-climate-system-2-40932", + "write": true + }, + "40933": { + "title": "Heating connected, climate system 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-connected-climate-system-1-40933", + "write": true + }, + "40934": { + "title": "ERS 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-1-40934", + "write": true + }, + "40940": { + "title": "EB103/104-GP12", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eb103-104-gp12-40940", + "write": true + }, + "40941": { + "title": "EB105/106-GP12", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eb105-106-gp12-40941", + "write": true + }, + "40942": { + "title": "EB107/108-GP12", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eb107-108-gp12-40942", + "write": true + }, + "40943": { + "title": "BlockFreq 2 activated", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-2-activated-40943", + "write": true + }, + "40944": { + "title": "BlockFreq 1 activated", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-activated-40944", + "write": true + }, + "40949": { + "title": "Use room sensor climate system 8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-8-40949", + "write": true + }, + "40950": { + "title": "Use room sensor climate system 7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-7-40950", + "write": true + }, + "40951": { + "title": "Use room sensor climate system 6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-6-40951", + "write": true + }, + "40952": { + "title": "Use room sensor climate system 5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "use-room-sensor-climate-system-5-40952", + "write": true + }, + "40953": { + "title": "Room sensor set point value climate system 8", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-8-40953", + "write": true + }, + "40954": { + "title": "Room sensor set point value climate system 7", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-7-40954", + "write": true + }, + "40955": { + "title": "Room sensor set point value climate system 6", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-6-40955", + "write": true + }, + "40956": { + "title": "Room sensor set point value climate system 5", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "room-sensor-set-point-value-climate-system-5-40956", + "write": true + }, + "40957": { + "title": "Room sensor factor climate system 8", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-8-40957", + "write": true + }, + "40958": { + "title": "Room sensor factor climate system 7", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-7-40958", + "write": true + }, + "40959": { + "title": "Room sensor factor climate system 6", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-6-40959", + "write": true + }, + "40960": { + "title": "Room sensor factor climate system 5", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 20.0, + "name": "room-sensor-factor-climate-system-5-40960", + "write": true + }, + "40967": { + "title": "Cooling curve climate system 2", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 9.0, + "default": 0.0, + "name": "cooling-curve-climate-system-2-40967", + "write": true + }, + "40968": { + "title": "Cooling curve climate system 1", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 9.0, + "default": 0.0, + "name": "cooling-curve-climate-system-1-40968", + "write": true + }, + "40975": { + "title": "Cooling offset climate system 2", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "cooling-offset-climate-system-2-40975", + "write": true + }, + "40976": { + "title": "Cooling offset climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "cooling-offset-climate-system-1-40976", + "write": true + }, + "40977": { + "title": "Own curve, cooling P4", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 40.0, + "default": 20.0, + "name": "own-curve-cooling-p4-40977", + "write": true + }, + "40978": { + "title": "Own curve, cooling P2", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 40.0, + "default": 20.0, + "name": "own-curve-cooling-p2-40978", + "write": true + }, + "40979": { + "title": "Own curve, cooling P1", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -5.0, + "max": 40.0, + "default": 20.0, + "name": "own-curve-cooling-p1-40979", + "write": true + }, + "40981": { + "title": "Current transformer ratio", + "factor": 1, + "size": "u16", + "min": 300.0, + "max": 3000.0, + "default": 300.0, + "name": "current-transformer-ratio-40981", + "write": true + }, + "40982": { + "title": "Room sensor set point value climate system 8, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-8-cooling-40982", + "write": true + }, + "40983": { + "title": "Room sensor set point value climate system 7, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-7-cooling-40983", + "write": true + }, + "40984": { + "title": "Room sensor set point value climate system 6, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-6-cooling-40984", + "write": true + }, + "40985": { + "title": "Room sensor set point value climate system 5, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-5-cooling-40985", + "write": true + }, + "40986": { + "title": "Room sensor set point value climate system 4, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-4-cooling-40986", + "write": true + }, + "40987": { + "title": "Room sensor set point value climate system 3, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-3-cooling-40987", + "write": true + }, + "40988": { + "title": "Room sensor set point value climate system 2, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-2-cooling-40988", + "write": true + }, + "40989": { + "title": "Room sensor set point value climate system 1, cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 350.0, + "default": 250.0, + "name": "room-sensor-set-point-value-climate-system-1-cooling-40989", + "write": true + }, + "40990": { + "title": "Room sensor factor climate system 8, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-8-cooling-40990", + "write": true + }, + "40991": { + "title": "Room sensor factor climate system 7, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-7-cooling-40991", + "write": true + }, + "40992": { + "title": "Room sensor factor climate system 6, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-6-cooling-40992", + "write": true + }, + "40993": { + "title": "Room sensor factor climate system 5, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-5-cooling-40993", + "write": true + }, + "40994": { + "title": "Room sensor factor climate system 4, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-4-cooling-40994", + "write": true + }, + "40995": { + "title": "Room sensor factor climate system 3, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-3-cooling-40995", + "write": true + }, + "40996": { + "title": "Room sensor factor climate system 2, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-2-cooling-40996", + "write": true + }, + "40997": { + "title": "Room sensor factor climate system 1, cooling", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 60.0, + "default": 10.0, + "name": "room-sensor-factor-climate-system-1-cooling-40997", + "write": true + }, + "40998": { + "title": "Set point value (RH)", + "factor": 1, + "unit": "%", + "size": "s8", + "min": 30.0, + "max": 90.0, + "default": 60.0, + "name": "set-point-value-rh-40998", + "write": true + }, + "40999": { + "title": "HTS 1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-1-40999", + "write": true + }, + "41007": { + "title": "Prevent condensation climate system 1", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "prevent-condensation-climate-system-1-41007", + "write": true + }, + "41016": { + "title": "OPT", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "opt-41016", + "write": true + }, + "41017": { + "title": "DM start difference (OPT)", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": 10.0, + "max": 2000.0, + "default": 700.0, + "name": "dm-start-difference-opt-41017", + "write": true + }, + "41022": { + "title": "Exhaust air fan speed 4 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 100.0, + "name": "exhaust-air-fan-speed-4-ers-1-41022", + "write": true + }, + "41023": { + "title": "Exhaust air fan speed 3 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 80.0, + "name": "exhaust-air-fan-speed-3-ers-1-41023", + "write": true + }, + "41024": { + "title": "Exhaust air fan speed 2 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 30.0, + "name": "exhaust-air-fan-speed-2-ers-1-41024", + "write": true + }, + "41025": { + "title": "Exhaust air fan speed 1 (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 0.0, + "name": "exhaust-air-fan-speed-1-ers-1-41025", + "write": true + }, + "41026": { + "title": "Exhaust air fan speed normal (ERS 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 75.0, + "name": "exhaust-air-fan-speed-normal-ers-1-41026", + "write": true + }, + "41027": { + "title": "Thermostat (ACS)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "thermostat-acs-41027", + "write": true + }, + "41028": { + "title": "Filtering time (BT64)", + "factor": 1, + "unit": "min", + "size": "u8", + "min": 5.0, + "max": 30.0, + "default": 5.0, + "name": "filtering-time-bt64-41028", + "write": true + }, + "41029": { + "title": "(ACS) - Thermostat, hysteresis between compressors", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": 1.0, + "max": 10.0, + "default": 2.0, + "name": "acs-thermostat-hysteresis-between-compressors-41029", + "write": true + }, + "41030": { + "title": "Start temperature (BT64)", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -8.0, + "max": 30.0, + "default": 10.0, + "name": "start-temperature-bt64-41030", + "write": true + }, + "41031": { + "title": "Temperature to transfer to borehole", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -8.0, + "max": 30.0, + "default": 0.0, + "name": "temperature-to-transfer-to-borehole-41031", + "write": true + }, + "41045": { + "title": "Bypass temp. (ERS 1)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 2.0, + "max": 10.0, + "default": 4.0, + "name": "bypass-temp-ers-1-41045", + "write": true + }, + "41050": { + "title": "Flow sensor activated X22", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "flow-sensor-activated-x22-41050", + "write": true + }, + "41053": { + "title": "Max. internal additional heat SG Ready", + "factor": 100, + "unit": "kW", + "size": "s16", + "min": 0.0, + "max": 900.0, + "default": 700.0, + "name": "max-internal-additional-heat-sg-ready-41053", + "write": true + }, + "41064": { + "title": "Limit humidity in the room, cooling climate system 1", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "limit-humidity-in-the-room-cooling-climate-system-1-41064", + "write": true + }, + "41067": { + "title": "Hysteresis (OPT)", + "factor": 1, + "size": "s16", + "min": 10.0, + "max": 2000.0, + "default": 100.0, + "name": "hysteresis-opt-41067", + "write": true + }, + "41070": { + "title": "PV panel affects heating (EME)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pv-panel-affects-heating-eme-41070", + "write": true + }, + "41071": { + "title": "PV panel affects hot water (EME)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pv-panel-affects-hot-water-eme-41071", + "write": true + }, + "41072": { + "title": "Delay timer EME", + "factor": 1, + "size": "u16", + "name": "delay-timer-eme-41072", + "write": true + }, + "41073": { + "title": "Low brine out alarm temperature (EP15)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -120.0, + "max": 150.0, + "default": -80.0, + "name": "low-brine-out-alarm-temperature-ep15-41073", + "write": true + }, + "41075": { + "title": "Pump 4 (FLM)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pump-4-flm-41075", + "write": true + }, + "41076": { + "title": "Pump 3 (FLM)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pump-3-flm-41076", + "write": true + }, + "41077": { + "title": "Pump 2 (FLM)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "pump-2-flm-41077", + "write": true + }, + "41078": { + "title": "Defrosting time (FLM 4)", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 30.0, + "default": 10.0, + "name": "defrosting-time-flm-4-41078", + "write": true + }, + "41079": { + "title": "Defrosting time (FLM 3)", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 30.0, + "default": 10.0, + "name": "defrosting-time-flm-3-41079", + "write": true + }, + "41080": { + "title": "Defrosting time (FLM 2)", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 30.0, + "default": 10.0, + "name": "defrosting-time-flm-2-41080", + "write": true + }, + "41081": { + "title": "Cooling (FLM 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "cooling-flm-4-41081", + "write": true + }, + "41082": { + "title": "Cooling (FLM 3)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "cooling-flm-3-41082", + "write": true + }, + "41083": { + "title": "Cooling (FLM 2)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "cooling-flm-2-41083", + "write": true + }, + "41084": { + "title": "Pump speed (FLM 4)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "pump-speed-flm-4-41084", + "write": true + }, + "41085": { + "title": "Pump speed (FLM 3)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "pump-speed-flm-3-41085", + "write": true + }, + "41086": { + "title": "Pump speed (FLM 2)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "pump-speed-flm-2-41086", + "write": true + }, + "41087": { + "title": "Pump speed (FLM 1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 100.0, + "name": "pump-speed-flm-1-41087", + "write": true + }, + "41088": { + "title": "Excess temperature (FLM 4)", + "factor": 10, + "unit": "\u00b0C", + "size": "u8", + "min": 10.0, + "max": 100.0, + "default": 30.0, + "name": "excess-temperature-flm-4-41088", + "write": true + }, + "41089": { + "title": "Excess temperature (FLM 3)", + "factor": 10, + "unit": "\u00b0C", + "size": "u8", + "min": 10.0, + "max": 100.0, + "default": 30.0, + "name": "excess-temperature-flm-3-41089", + "write": true + }, + "41090": { + "title": "Excess temperature (FLM 2)", + "factor": 10, + "unit": "\u00b0C", + "size": "u8", + "min": 10.0, + "max": 100.0, + "default": 30.0, + "name": "excess-temperature-flm-2-41090", + "write": true + }, + "41091": { + "title": "Excess temperature (FLM 1)", + "factor": 10, + "unit": "\u00b0C", + "size": "u8", + "min": 10.0, + "max": 100.0, + "default": 30.0, + "name": "excess-temperature-flm-1-41091", + "write": true + }, + "41092": { + "title": "Set point value, cooling (FLM 4)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 400.0, + "default": 210.0, + "name": "set-point-value-cooling-flm-4-41092", + "write": true + }, + "41093": { + "title": "Set point value, cooling (FLM 3)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 400.0, + "default": 210.0, + "name": "set-point-value-cooling-flm-3-41093", + "write": true + }, + "41094": { + "title": "Set point value, cooling (FLM 2)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 400.0, + "default": 210.0, + "name": "set-point-value-cooling-flm-2-41094", + "write": true + }, + "41095": { + "title": "Set point value, cooling (FLM 1)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 400.0, + "default": 210.0, + "name": "set-point-value-cooling-flm-1-41095", + "write": true + }, + "41096": { + "title": "AUX blocking (OPT)", + "factor": 1, + "size": "u8", + "name": "aux-blocking-opt-41096", + "write": true + }, + "41097": { + "title": "Outdoor air mixing", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "outdoor-air-mixing-41097", + "write": true + }, + "41103": { + "title": "Smart home room control", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "smart-home-room-control-41103", + "write": true + }, + "41104": { + "title": "Speed, brine pump, standby mode (EP14)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 0.0, + "max": 100.0, + "default": 30.0, + "name": "speed-brine-pump-standby-mode-ep14-41104", + "write": true + }, + "41106": { + "title": "Smart Energy Source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "smart-energy-source-41106", + "write": true + }, + "41107": { + "title": "Control method, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "control-method-smart-energy-source-41107", + "write": true + }, + "41108": { + "title": "El. price, special, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 0.0, + "name": "el-price-special-smart-energy-source-41108", + "write": true + }, + "41109": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41109", + "write": true + }, + "41110": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41110", + "write": true + }, + "41111": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41111", + "write": true + }, + "41112": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 3.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41112", + "write": true + }, + "41113": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41113", + "write": true + }, + "41114": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41114", + "write": true + }, + "41115": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41115", + "write": true + }, + "41116": { + "title": "El. price, smart energy source", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "el-price-smart-energy-source-41116", + "write": true + }, + "41117": { + "title": "El. price, fixed, smart energy source", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-smart-energy-source-41117", + "write": true + }, + "41118": { + "title": "Prim. factor, smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 25.0, + "name": "prim-factor-smart-energy-source-41118", + "write": true + }, + "41119": { + "title": "Prim. factor, shunt add. heat smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 10.0, + "name": "prim-factor-shunt-add-heat-smart-energy-source-41119", + "write": true + }, + "41120": { + "title": "Prim. factor, ext. step add. heat smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 10.0, + "name": "prim-factor-ext-step-add-heat-smart-energy-source-41120", + "write": true + }, + "41121": { + "title": "Prim. factor, OPT10 smart energy source", + "factor": 10, + "size": "u8", + "min": 0.0, + "max": 50.0, + "default": 10.0, + "name": "prim-factor-opt10-smart-energy-source-41121", + "write": true + }, + "41122": { + "title": "OPT10, high tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "opt10-high-tariff-price-smart-energy-source-41122", + "write": true + }, + "41123": { + "title": "OPT10, low tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "opt10-low-tariff-price-smart-energy-source-41123", + "write": true + }, + "41124": { + "title": "ext. step add. heat, high tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "ext-step-add-heat-high-tariff-price-smart-energy-source-41124", + "write": true + }, + "41125": { + "title": "ext. step add. heat, low tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "ext-step-add-heat-low-tariff-price-smart-energy-source-41125", + "write": true + }, + "41126": { + "title": "Shunt add. heat, high tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "shunt-add-heat-high-tariff-price-smart-energy-source-41126", + "write": true + }, + "41127": { + "title": "Shunt add. heat, low tariff price smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "shunt-add-heat-low-tariff-price-smart-energy-source-41127", + "write": true + }, + "41128": { + "title": "El. price, fixed, high tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-high-tariff-smart-energy-source-41128", + "write": true + }, + "41129": { + "title": "El. price, fixed, low tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-fixed-low-tariff-smart-energy-source-41129", + "write": true + }, + "41130": { + "title": "El. price, variable, high tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-variable-high-tariff-smart-energy-source-41130", + "write": true + }, + "41131": { + "title": "El. price, variable, low tariff smart energy source", + "factor": 1, + "size": "u16", + "min": 1.0, + "max": 10000.0, + "default": 100.0, + "name": "el-price-variable-low-tariff-smart-energy-source-41131", + "write": true + }, + "41132": { + "title": "DM start source, priority 5 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-5-smart-energy-source-41132", + "write": true + }, + "41133": { + "title": "DM start source, priority 4 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-4-smart-energy-source-41133", + "write": true + }, + "41134": { + "title": "DM start source, priority 3 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-3-smart-energy-source-41134", + "write": true + }, + "41135": { + "title": "DM start source, priority 2 smart energy source", + "factor": 1, + "size": "s16", + "min": 100.0, + "max": 2000.0, + "default": 400.0, + "name": "dm-start-source-priority-2-smart-energy-source-41135", + "write": true + }, + "41136": { + "title": "DM start source, priority 1 smart energy source", + "factor": 1, + "size": "s16", + "min": -2000.0, + "max": -10.0, + "default": -60.0, + "name": "dm-start-source-priority-1-smart-energy-source-41136", + "write": true + }, + "41137": { + "title": "Start day, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-smart-energy-source-41137", + "write": true + }, + "41138": { + "title": "End day, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-smart-energy-source-41138", + "write": true + }, + "41139": { + "title": "Start month, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-smart-energy-source-41139", + "write": true + }, + "41140": { + "title": "End month, tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-smart-energy-source-41140", + "write": true + }, + "41173": { + "title": "Start day, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-fixed-tariff-smart-energy-source-41173", + "write": true + }, + "41174": { + "title": "End day, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-fixed-tariff-smart-energy-source-41174", + "write": true + }, + "41175": { + "title": "Start month, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-fixed-tariff-smart-energy-source-41175", + "write": true + }, + "41176": { + "title": "End month, fixed tariff smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-fixed-tariff-smart-energy-source-41176", + "write": true + }, + "41209": { + "title": "Start day, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-opt10-smart-energy-source-41209", + "write": true + }, + "41210": { + "title": "End day, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-opt10-smart-energy-source-41210", + "write": true + }, + "41211": { + "title": "Start month, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-opt10-smart-energy-source-41211", + "write": true + }, + "41212": { + "title": "End month, tariff OPT10 smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-opt10-smart-energy-source-41212", + "write": true + }, + "41245": { + "title": "Start day tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-shunt-additional-heat-smart-energy-source-41245", + "write": true + }, + "41246": { + "title": "End day tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-shunt-additional-heat-smart-energy-source-41246", + "write": true + }, + "41247": { + "title": "Start month tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-shunt-additional-heat-smart-energy-source-41247", + "write": true + }, + "41248": { + "title": "End month tariff, shunt additional heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-shunt-additional-heat-smart-energy-source-41248", + "write": true + }, + "41281": { + "title": "Start day tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 1.0, + "name": "start-day-tariff-ext-step-add-heat-smart-energy-source-41281", + "write": true + }, + "41282": { + "title": "End day tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 31.0, + "default": 31.0, + "name": "end-day-tariff-ext-step-add-heat-smart-energy-source-41282", + "write": true + }, + "41283": { + "title": "Start month tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 1.0, + "name": "start-month-tariff-ext-step-add-heat-smart-energy-source-41283", + "write": true + }, + "41284": { + "title": "End month tariff, ext. step add. heat smart energy source", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 12.0, + "default": 12.0, + "name": "end-month-tariff-ext-step-add-heat-smart-energy-source-41284", + "write": true + }, + "41317": { + "title": "Ground water pump temperature alarm", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ground-water-pump-temperature-alarm-41317", + "write": true + }, + "41318": { + "title": "Ground water pump temperature alarm level", + "factor": 1, + "unit": "\u00b0C", + "size": "s8", + "min": -15.0, + "max": 20.0, + "default": 3.0, + "name": "ground-water-pump-temperature-alarm-level-41318", + "write": true + }, + "41319": { + "title": "Constant delta T, brine pump", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 2.0, + "max": 10.0, + "default": 4.0, + "name": "constant-delta-t-brine-pump-41319", + "write": true + }, + "41320": { + "title": "Brine pump auto mode", + "factor": 1, + "size": "s8", + "min": 0.0, + "max": 2.0, + "default": 1.0, + "name": "brine-pump-auto-mode-41320", + "write": true + }, + "41327": { + "title": "Max difference, SES priority 1 energy source", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 100.0, + "name": "max-difference-ses-priority-1-energy-source-41327", + "write": true + }, + "41328": { + "title": "Max difference, SES lower priority energy source", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 10.0, + "max": 250.0, + "default": 70.0, + "name": "max-difference-ses-lower-priority-energy-source-41328", + "write": true + }, + "41329": { + "title": "Delta brine pump passive cooling", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 1.0, + "max": 15.0, + "default": 4.0, + "name": "delta-brine-pump-passive-cooling-41329", + "write": true + }, + "41551": { + "title": "Installed (EB101)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "installed-eb101-41551", + "write": true + }, + "44001": { + "title": "EME20", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eme20-44001", + "write": true + }, + "32177": { + "title": "Current power", + "factor": 1, + "unit": "W", + "size": "u32", + "name": "current-power-32177" + }, + "44007": { + "title": "Speed of circulation pump passive cooling (EP15)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-of-circulation-pump-passive-cooling-ep15-44007", + "write": true + }, + "44008": { + "title": "Speed of circulation pump active cooling (EP15)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-of-circulation-pump-active-cooling-ep15-44008", + "write": true + }, + "44013": { + "title": "Ground water pump's control signal", + "factor": 1, + "size": "s8", + "name": "ground-water-pump-s-control-signal-44013", + "write": true + }, + "44015": { + "title": "BT12 offset", + "factor": 10, + "unit": "\u00b0C", + "size": "s8", + "min": -50.0, + "max": 50.0, + "default": 0.0, + "name": "bt12-offset-44015", + "write": true + }, + "32179": { + "title": "Total average power (EME 20)", + "factor": 100, + "unit": "kW", + "size": "u32", + "name": "total-average-power-eme-20-32179" + }, + "32181": { + "title": "Total energy", + "factor": 10, + "unit": "kWh", + "size": "s32", + "name": "total-energy-32181" + }, + "44077": { + "title": "ERS 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-2-44077", + "write": true + }, + "44078": { + "title": "ERS 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-3-44078", + "write": true + }, + "44079": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-4-44079", + "write": true + }, + "41982": { + "title": "HTS 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-2-41982", + "write": true + }, + "41983": { + "title": "HTS 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-3-41983", + "write": true + }, + "41984": { + "title": "HTS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "hts-4-41984", + "write": true + }, + "44139": { + "title": "External adjustment, cooling climate system 8", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-8-44139", + "write": true + }, + "44140": { + "title": "External adjustment, cooling climate system 7", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-7-44140", + "write": true + }, + "44141": { + "title": "External adjustment, cooling climate system 6", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-6-44141", + "write": true + }, + "44142": { + "title": "External adjustment, cooling climate system 5", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-5-44142", + "write": true + }, + "44143": { + "title": "External adjustment, cooling climate system 4", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-4-44143", + "write": true + }, + "44144": { + "title": "External adjustment, cooling climate system 3", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-3-44144", + "write": true + }, + "44145": { + "title": "External adjustment, cooling climate system 2", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-2-44145", + "write": true + }, + "44146": { + "title": "External adjustment, cooling climate system 1", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 10.0, + "default": 0.0, + "name": "external-adjustment-cooling-climate-system-1-44146", + "write": true + }, + "44147": { + "title": "External adjustment with room sensor, cooling climate system 8", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-8-44147", + "write": true + }, + "44148": { + "title": "External adjustment with room sensor, cooling climate system 7", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-7-44148", + "write": true + }, + "44149": { + "title": "External adjustment with room sensor, cooling climate system 6", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-6-44149", + "write": true + }, + "44150": { + "title": "External adjustment with room sensor, cooling climate system 5", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-5-44150", + "write": true + }, + "44151": { + "title": "External adjustment with room sensor, cooling climate system 4", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-4-44151", + "write": true + }, + "44152": { + "title": "External adjustment with room sensor, cooling climate system 3", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-3-44152", + "write": true + }, + "44153": { + "title": "External adjustment with room sensor, cooling climate system 2", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-2-44153", + "write": true + }, + "44154": { + "title": "External adjustment with room sensor, cooling climate system 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 50.0, + "max": 300.0, + "default": 200.0, + "name": "external-adjustment-with-room-sensor-cooling-climate-system-1-44154", + "write": true + }, + "32728": { + "title": "Current power", + "factor": 100, + "unit": "kW", + "size": "u32", + "name": "current-power-32728" + }, + "44165": { + "title": "blockFreq 1 (EB102)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb102-44165", + "write": true + }, + "44166": { + "title": "blockFreq 1 (EB103)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb103-44166", + "write": true + }, + "44167": { + "title": "blockFreq 1 (EB104)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb104-44167", + "write": true + }, + "44168": { + "title": "blockFreq 1 (EB105)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb105-44168", + "write": true + }, + "44169": { + "title": "blockFreq 1 (EB106)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb106-44169", + "write": true + }, + "44170": { + "title": "blockFreq 1 (EB107)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb107-44170", + "write": true + }, + "44171": { + "title": "blockFreq 1 (EB108)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "blockfreq-1-eb108-44171", + "write": true + }, + "44201": { + "title": "Power at DOT, manual value", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "power-at-dot-manual-value-44201", + "write": true + }, + "32133": { + "title": "Hi press (BP9)", + "factor": 100, + "unit": "bar", + "size": "s16", + "name": "hi-press-bp9-32133" + }, + "44101": { + "title": "Blocking actions (ERS 3)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-3-44101", + "write": true + }, + "44102": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-44102", + "write": true + }, + "32130": { + "title": "Evaporator (BT84)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "evaporator-bt84-32130" + }, + "45455": { + "title": "EB103/104-GP12", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eb103-104-gp12-45455", + "write": true + }, + "45352": { + "title": "Minimum permitted speed (EB100 GP1)", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 50.0, + "default": 1.0, + "name": "minimum-permitted-speed-eb100-gp1-45352", + "write": true + }, + "32127": { + "title": "High pressure (BP9 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "high-pressure-bp9-dew-32127" + }, + "32128": { + "title": "Low pressure (BP8 dew)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "low-pressure-bp8-dew-32128" + }, + "40177": { + "title": "System 1 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-1-rmu-40177", + "write": true + }, + "40178": { + "title": "System 2 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-2-rmu-40178", + "write": true + }, + "40179": { + "title": "System 3 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-3-rmu-40179", + "write": true + }, + "40180": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-40180", + "write": true + }, + "41999": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-41999", + "write": true + }, + "42000": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-42000", + "write": true + }, + "42001": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-42001", + "write": true + }, + "42002": { + "title": "System 4 (RMU)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "system-4-rmu-42002", + "write": true + }, + "42743": { + "title": "The start guide has been run", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "the-start-guide-has-been-run-42743", + "write": true + }, + "45327": { + "title": "Audio signal on alarm", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "audio-signal-on-alarm-45327", + "write": true + }, + "45328": { + "title": "Sound when pressing button", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "sound-when-pressing-button-45328", + "write": true + }, + "43058": { + "title": "ERS S40 7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-s40-7-43058", + "write": true + }, + "43032": { + "title": "Alarm room sens cool oper", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "alarm-room-sens-cool-oper-43032", + "write": true + }, + "43060": { + "title": "Heating, auto", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "heating-auto-43060", + "write": true + }, + "43034": { + "title": "Factor", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 10.0, + "default": 5.0, + "name": "factor-43034", + "write": true + }, + "43089": { + "title": "Period", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "period-43089", + "write": true + }, + "43090": { + "title": "Number of years", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 10.0, + "default": 1.0, + "name": "number-of-years-43090", + "write": true + }, + "43091": { + "title": "Months", + "factor": 1, + "size": "u32", + "min": 0.0, + "max": 4095.0, + "default": 4095.0, + "name": "months-43091", + "write": true + }, + "43067": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43067", + "write": true + }, + "43068": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43068", + "write": true + }, + "43069": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43069", + "write": true + }, + "43070": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43070", + "write": true + }, + "43071": { + "title": "Active days", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 127.0, + "default": 0.0, + "name": "active-days-43071", + "write": true + }, + "45394": { + "title": "Start time", + "factor": 1, + "size": "u16", + "name": "start-time-45394", + "write": true + }, + "45398": { + "title": "Start time", + "factor": 1, + "size": "u16", + "name": "start-time-45398", + "write": true + }, + "45402": { + "title": "Stop time", + "factor": 1, + "size": "u16", + "name": "stop-time-45402", + "write": true + }, + "42767": { + "title": "Allow add. heat during defrosting", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "allow-add-heat-during-defrosting-42767", + "write": true + }, + "42765": { + "title": "K4 relay is Normally Closed", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "k4-relay-is-normally-closed-42765", + "write": true + }, + "42668": { + "title": "Offset cooling (EME20)", + "factor": 1, + "size": "s8", + "min": -10.0, + "max": 0.0, + "default": -1.0, + "name": "offset-cooling-eme20-42668", + "write": true + }, + "42669": { + "title": "Offset heating (EME20)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 1.0, + "name": "offset-heating-eme20-42669", + "write": true + }, + "42670": { + "title": "Offset pool (EME20)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 10.0, + "name": "offset-pool-eme20-42670", + "write": true + }, + "42667": { + "title": "Cooling (EME20)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "cooling-eme20-42667", + "write": true + }, + "42676": { + "title": "AUX (EME20)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "aux-eme20-42676", + "write": true + }, + "40001": { + "title": "Temperature, Overload, pool", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 1.0, + "max": 50.0, + "default": 1.0, + "name": "temperature-overload-pool-40001", + "write": true + }, + "42108": { + "title": "EME20 API", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eme20-api-42108", + "write": true + }, + "42109": { + "title": "EME20 API Include own consumption", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "eme20-api-include-own-consumption-42109", + "write": true + }, + "42110": { + "title": "EME20 API Available power", + "factor": 1, + "size": "u16", + "min": 0.0, + "max": 65535.0, + "default": 0.0, + "name": "eme20-api-available-power-42110", + "write": true + }, + "42112": { + "title": "External adjustment input, main unit (ECS1)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-main-unit-ecs1-42112", + "write": true + }, + "42113": { + "title": "External adjustment input (ECS2)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs2-42113", + "write": true + }, + "42114": { + "title": "External adjustment input (ECS3)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs3-42114", + "write": true + }, + "42115": { + "title": "External adjustment input (ECS4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs4-42115", + "write": true + }, + "42116": { + "title": "External adjustment input (ECS5)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs5-42116", + "write": true + }, + "42117": { + "title": "External adjustment input (ECS6)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs6-42117", + "write": true + }, + "42118": { + "title": "External adjustment input (ECS7)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs7-42118", + "write": true + }, + "42119": { + "title": "External adjustment input (ECS8)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-adjustment-input-ecs8-42119", + "write": true + }, + "42120": { + "title": "Zone 1 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-1-affected-by-ecs1-42120", + "write": true + }, + "42121": { + "title": "Zone 2 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-2-affected-by-ecs1-42121", + "write": true + }, + "42122": { + "title": "Zone 3 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-3-affected-by-ecs1-42122", + "write": true + }, + "42123": { + "title": "Zone 4 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-4-affected-by-ecs1-42123", + "write": true + }, + "42124": { + "title": "Zone 5 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-5-affected-by-ecs1-42124", + "write": true + }, + "42125": { + "title": "Zone 6 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-6-affected-by-ecs1-42125", + "write": true + }, + "42126": { + "title": "Zone 7 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-7-affected-by-ecs1-42126", + "write": true + }, + "42127": { + "title": "Zone 8 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-8-affected-by-ecs1-42127", + "write": true + }, + "42128": { + "title": "Zone 9 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-9-affected-by-ecs1-42128", + "write": true + }, + "42129": { + "title": "Zone 10 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-10-affected-by-ecs1-42129", + "write": true + }, + "42130": { + "title": "Zone 11 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-11-affected-by-ecs1-42130", + "write": true + }, + "42131": { + "title": "Zone 12 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-12-affected-by-ecs1-42131", + "write": true + }, + "42132": { + "title": "Zone 13 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-13-affected-by-ecs1-42132", + "write": true + }, + "42133": { + "title": "Zone 14 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-14-affected-by-ecs1-42133", + "write": true + }, + "42134": { + "title": "Zone 15 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-15-affected-by-ecs1-42134", + "write": true + }, + "42135": { + "title": "Zone 16 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-16-affected-by-ecs1-42135", + "write": true + }, + "42136": { + "title": "Zone 17 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-17-affected-by-ecs1-42136", + "write": true + }, + "42137": { + "title": "Zone 18 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-18-affected-by-ecs1-42137", + "write": true + }, + "42138": { + "title": "Zone 19 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-19-affected-by-ecs1-42138", + "write": true + }, + "42139": { + "title": "Zone 20 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-20-affected-by-ecs1-42139", + "write": true + }, + "42140": { + "title": "Zone 21 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-21-affected-by-ecs1-42140", + "write": true + }, + "42141": { + "title": "Zone 22 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-22-affected-by-ecs1-42141", + "write": true + }, + "42142": { + "title": "Zone 23 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-23-affected-by-ecs1-42142", + "write": true + }, + "42143": { + "title": "Zone 24 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-24-affected-by-ecs1-42143", + "write": true + }, + "42144": { + "title": "Zone 25 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-25-affected-by-ecs1-42144", + "write": true + }, + "42145": { + "title": "Zone 26 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-26-affected-by-ecs1-42145", + "write": true + }, + "42146": { + "title": "Zone 27 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-27-affected-by-ecs1-42146", + "write": true + }, + "42147": { + "title": "Zone 28 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-28-affected-by-ecs1-42147", + "write": true + }, + "42148": { + "title": "Zone 29 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-29-affected-by-ecs1-42148", + "write": true + }, + "42149": { + "title": "Zone 30 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-30-affected-by-ecs1-42149", + "write": true + }, + "42150": { + "title": "Zone 31 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-31-affected-by-ecs1-42150", + "write": true + }, + "42151": { + "title": "Zone 32 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-32-affected-by-ecs1-42151", + "write": true + }, + "42152": { + "title": "Zone 33 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-33-affected-by-ecs1-42152", + "write": true + }, + "42153": { + "title": "Zone 34 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-34-affected-by-ecs1-42153", + "write": true + }, + "42154": { + "title": "Zone 35 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-35-affected-by-ecs1-42154", + "write": true + }, + "42155": { + "title": "Zone 36 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-36-affected-by-ecs1-42155", + "write": true + }, + "42156": { + "title": "Zone 37 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-37-affected-by-ecs1-42156", + "write": true + }, + "42157": { + "title": "Zone 38 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-38-affected-by-ecs1-42157", + "write": true + }, + "42158": { + "title": "Zone 39 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-39-affected-by-ecs1-42158", + "write": true + }, + "42159": { + "title": "Zone 40 affected by ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-40-affected-by-ecs1-42159", + "write": true + }, + "42160": { + "title": "Zone 1 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-1-affected-by-ecs2-42160", + "write": true + }, + "42161": { + "title": "Zone 2 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-2-affected-by-ecs2-42161", + "write": true + }, + "42162": { + "title": "Zone 3 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-3-affected-by-ecs2-42162", + "write": true + }, + "42163": { + "title": "Zone 4 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-4-affected-by-ecs2-42163", + "write": true + }, + "42164": { + "title": "Zone 5 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-5-affected-by-ecs2-42164", + "write": true + }, + "42165": { + "title": "Zone 6 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-6-affected-by-ecs2-42165", + "write": true + }, + "42166": { + "title": "Zone 7 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-7-affected-by-ecs2-42166", + "write": true + }, + "42167": { + "title": "Zone 8 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-8-affected-by-ecs2-42167", + "write": true + }, + "42168": { + "title": "Zone 9 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-9-affected-by-ecs2-42168", + "write": true + }, + "42169": { + "title": "Zone 10 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-10-affected-by-ecs2-42169", + "write": true + }, + "42170": { + "title": "Zone 11 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-11-affected-by-ecs2-42170", + "write": true + }, + "42171": { + "title": "Zone 12 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-12-affected-by-ecs2-42171", + "write": true + }, + "42172": { + "title": "Zone 13 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-13-affected-by-ecs2-42172", + "write": true + }, + "42173": { + "title": "Zone 14 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-14-affected-by-ecs2-42173", + "write": true + }, + "42174": { + "title": "Zone 15 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-15-affected-by-ecs2-42174", + "write": true + }, + "42175": { + "title": "Zone 16 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-16-affected-by-ecs2-42175", + "write": true + }, + "42176": { + "title": "Zone 17 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-17-affected-by-ecs2-42176", + "write": true + }, + "42177": { + "title": "Zone 18 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-18-affected-by-ecs2-42177", + "write": true + }, + "42178": { + "title": "Zone 19 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-19-affected-by-ecs2-42178", + "write": true + }, + "42179": { + "title": "Zone 20 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-20-affected-by-ecs2-42179", + "write": true + }, + "42180": { + "title": "Zone 21 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-21-affected-by-ecs2-42180", + "write": true + }, + "42181": { + "title": "Zone 22 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-22-affected-by-ecs2-42181", + "write": true + }, + "42182": { + "title": "Zone 23 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-23-affected-by-ecs2-42182", + "write": true + }, + "42183": { + "title": "Zone 24 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-24-affected-by-ecs2-42183", + "write": true + }, + "42184": { + "title": "Zone 25 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-25-affected-by-ecs2-42184", + "write": true + }, + "42185": { + "title": "Zone 26 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-26-affected-by-ecs2-42185", + "write": true + }, + "42186": { + "title": "Zone 27 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-27-affected-by-ecs2-42186", + "write": true + }, + "42187": { + "title": "Zone 28 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-28-affected-by-ecs2-42187", + "write": true + }, + "42188": { + "title": "Zone 29 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-29-affected-by-ecs2-42188", + "write": true + }, + "42189": { + "title": "Zone 30 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-30-affected-by-ecs2-42189", + "write": true + }, + "42190": { + "title": "Zone 31 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-31-affected-by-ecs2-42190", + "write": true + }, + "42191": { + "title": "Zone 32 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-32-affected-by-ecs2-42191", + "write": true + }, + "42192": { + "title": "Zone 33 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-33-affected-by-ecs2-42192", + "write": true + }, + "42193": { + "title": "Zone 34 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-34-affected-by-ecs2-42193", + "write": true + }, + "42194": { + "title": "Zone 35 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-35-affected-by-ecs2-42194", + "write": true + }, + "42195": { + "title": "Zone 36 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-36-affected-by-ecs2-42195", + "write": true + }, + "42196": { + "title": "Zone 37 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-37-affected-by-ecs2-42196", + "write": true + }, + "42197": { + "title": "Zone 38 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-38-affected-by-ecs2-42197", + "write": true + }, + "42198": { + "title": "Zone 39 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-39-affected-by-ecs2-42198", + "write": true + }, + "42199": { + "title": "Zone 40 affected by ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "zone-40-affected-by-ecs2-42199", + "write": true + }, + "42440": { + "title": "Input on ECS1 affects ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs1-42440", + "write": true + }, + "42441": { + "title": "Input on ECS1 affects ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs2-42441", + "write": true + }, + "42442": { + "title": "Input on ECS1 affects ECS3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs3-42442", + "write": true + }, + "42443": { + "title": "Input on ECS1 affects ECS4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs4-42443", + "write": true + }, + "42444": { + "title": "Input on ECS1 affects ECS5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs5-42444", + "write": true + }, + "42445": { + "title": "Input on ECS1 affects ECS6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs6-42445", + "write": true + }, + "42446": { + "title": "Input on ECS1 affects ECS7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs7-42446", + "write": true + }, + "42447": { + "title": "Input on ECS1 affects ECS8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs1-affects-ecs8-42447", + "write": true + }, + "42448": { + "title": "Input on ECS2 affects ECS1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs1-42448", + "write": true + }, + "42449": { + "title": "Input on ECS2 affects ECS2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs2-42449", + "write": true + }, + "42450": { + "title": "Input on ECS2 affects ECS3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs3-42450", + "write": true + }, + "42451": { + "title": "Input on ECS2 affects ECS4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs4-42451", + "write": true + }, + "42452": { + "title": "Input on ECS2 affects ECS5", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs5-42452", + "write": true + }, + "42453": { + "title": "Input on ECS2 affects ECS6", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs6-42453", + "write": true + }, + "42454": { + "title": "Input on ECS2 affects ECS7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs7-42454", + "write": true + }, + "42455": { + "title": "Input on ECS2 affects ECS8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "input-on-ecs2-affects-ecs8-42455", + "write": true + }, + "42504": { + "title": "External setting for adjustment migrated", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "external-setting-for-adjustment-migrated-42504", + "write": true + }, + "42677": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42677", + "write": true + }, + "42678": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42678", + "write": true + }, + "42679": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42679", + "write": true + }, + "42680": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42680", + "write": true + }, + "32020": { + "title": "Cooling, passive", + "factor": 10, + "unit": "kWh", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "cooling-passive-32020" + }, + "42701": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42701", + "write": true + }, + "42702": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42702", + "write": true + }, + "42703": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42703", + "write": true + }, + "42704": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42704", + "write": true + }, + "42705": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42705", + "write": true + }, + "42706": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42706", + "write": true + }, + "42707": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42707", + "write": true + }, + "42708": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42708", + "write": true + }, + "42709": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42709", + "write": true + }, + "42710": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42710", + "write": true + }, + "42711": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42711", + "write": true + }, + "42712": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42712", + "write": true + }, + "42713": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42713", + "write": true + }, + "42714": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42714", + "write": true + }, + "42715": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42715", + "write": true + }, + "42716": { + "title": "Return time fan 4", + "factor": 1, + "unit": "h", + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 4.0, + "name": "return-time-fan-4-42716", + "write": true + }, + "42729": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42729", + "write": true + }, + "42730": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42730", + "write": true + }, + "42731": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42731", + "write": true + }, + "42732": { + "title": "Time between filter replacement", + "factor": 1, + "size": "u8", + "min": 1.0, + "max": 24.0, + "default": 3.0, + "name": "time-between-filter-replacement-42732", + "write": true + }, + "42741": { + "title": "AUX from Modbus", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "aux-from-modbus-42741", + "write": true + }, + "42742": { + "title": "AUX from Modbus", + "factor": 1, + "size": "s16", + "name": "aux-from-modbus-42742", + "write": true + }, + "32167": { + "title": "Instantaneous used power", + "factor": 1, + "unit": "W", + "size": "u32", + "min": 0.0, + "max": 9999999.0, + "default": 0.0, + "name": "instantaneous-used-power-32167" + }, + "45102": { + "title": "Heat pump test - Silent mode (EB101/EB102)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "heat-pump-test-silent-mode-eb101-eb102-45102", + "write": true + }, + "42821": { + "title": "ERS 2", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-2-42821", + "write": true + }, + "42822": { + "title": "ERS 3", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-3-42822", + "write": true + }, + "42823": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-4-42823", + "write": true + }, + "42824": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "ers-4-42824", + "write": true + }, + "42825": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42825", + "write": true + }, + "42826": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42826", + "write": true + }, + "42827": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42827", + "write": true + }, + "42828": { + "title": "ERS 4", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 1.0, + "name": "ers-4-42828", + "write": true + }, + "42858": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42858", + "write": true + }, + "42859": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42859", + "write": true + }, + "42860": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42860", + "write": true + }, + "42861": { + "title": "Min. vent temp. (ERS 4)", + "factor": 1, + "unit": "\u00b0C", + "size": "u8", + "min": 0.0, + "max": 10.0, + "default": 3.0, + "name": "min-vent-temp-ers-4-42861", + "write": true + }, + "42829": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42829", + "write": true + }, + "42830": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42830", + "write": true + }, + "42831": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42831", + "write": true + }, + "42832": { + "title": "Blocking actions (ERS 4)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 2.0, + "default": 2.0, + "name": "blocking-actions-ers-4-42832", + "write": true + }, + "32169": { + "title": "Fan mode 5", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-5-32169" + }, + "32170": { + "title": "Fan mode 6", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-6-32170" + }, + "32171": { + "title": "Fan mode 7", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-7-32171" + }, + "32172": { + "title": "Fan mode 8", + "factor": 1, + "unit": "%", + "size": "u8", + "name": "fan-mode-8-32172" + }, + "45393": { + "title": "Disable emergency restart GP1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "disable-emergency-restart-gp1-45393", + "write": true + }, + "45026": { + "title": "Disable emergency restart GP1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "disable-emergency-restart-gp1-45026", + "write": true + }, + "45009": { + "title": "Modbus external control", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "modbus-external-control-45009", + "write": true + }, + "32284": { + "title": "Energy log - Produced energy for heating over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-produced-energy-for-heating-over-the-past-hour-32284" + }, + "32286": { + "title": "Energy log - Produced energy for hot water over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-produced-energy-for-hot-water-over-the-past-hour-32286" + }, + "32290": { + "title": "Energy log - Produced energy for cooling over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-produced-energy-for-cooling-over-the-past-hour-32290" + }, + "32292": { + "title": "Energy log - Used energy for heating over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-used-energy-for-heating-over-the-past-hour-32292" + }, + "32294": { + "title": "Energy log - Used energy for hot water over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-used-energy-for-hot-water-over-the-past-hour-32294" + }, + "32298": { + "title": "Energy log - Used energy for cooling over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-used-energy-for-cooling-over-the-past-hour-32298" + }, + "32300": { + "title": "Energy log - Used energy by additional heater for heating over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-used-energy-by-additional-heater-for-heating-over-the-past-hour-32300" + }, + "32302": { + "title": "Energy log - Used energy by additional heater for hot water over the past hour", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-used-energy-by-additional-heater-for-hot-water-over-the-past-hour-32302" + }, + "32306": { + "title": "Energy log - Current power consumption", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-current-power-consumption-32306" + }, + "32409": { + "title": "Energy log - Current power consumption, components", + "factor": 100, + "unit": "kWh", + "size": "u32", + "name": "energy-log-current-power-consumption-components-32409" + }, + "32336": { + "title": "Compressor, total time energy storage, main unit (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-main-unit-ep14-32336" + }, + "32338": { + "title": "Compressor, total time energy storage, main unit (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-main-unit-ep15-32338" + }, + "32340": { + "title": "Compressor, total time energy storage, heat pump 1 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-1-ep14-32340" + }, + "32342": { + "title": "Compressor, total time energy storage, heat pump 1 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-1-ep15-32342" + }, + "32344": { + "title": "Compressor, total time energy storage, heat pump 2 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-2-ep14-32344" + }, + "32346": { + "title": "Compressor, total time energy storage, heat pump 2 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-2-ep15-32346" + }, + "32348": { + "title": "Compressor, total time energy storage, heat pump 3 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-3-ep14-32348" + }, + "32350": { + "title": "Compressor, total time energy storage, heat pump 3 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-3-ep15-32350" + }, + "32352": { + "title": "Compressor, total time energy storage, heat pump 4 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-4-ep14-32352" + }, + "32354": { + "title": "Compressor, total time energy storage, heat pump 4 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-4-ep15-32354" + }, + "32356": { + "title": "Compressor, total time energy storage, heat pump 5 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-5-ep14-32356" + }, + "32358": { + "title": "Compressor, total time energy storage, heat pump 5 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-5-ep15-32358" + }, + "32360": { + "title": "Compressor, total time energy storage, heat pump 6 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-6-ep14-32360" + }, + "32362": { + "title": "Compressor, total time energy storage, heat pump 6 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-6-ep15-32362" + }, + "32364": { + "title": "Compressor, total time energy storage, heat pump 7 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-7-ep14-32364" + }, + "32366": { + "title": "Compressor, total time energy storage, heat pump 7 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-7-ep15-32366" + }, + "32368": { + "title": "Compressor, total time energy storage, heat pump 8 (EP14)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-8-ep14-32368" + }, + "32370": { + "title": "Compressor, total time energy storage, heat pump 8 (EP15)", + "factor": 1, + "unit": "h", + "size": "u32", + "min": 0.0, + "max": 2147483647.0, + "default": 0.0, + "name": "compressor-total-time-energy-storage-heat-pump-8-ep15-32370" + }, + "45078": { + "title": "Freeze protection with LP-Dew", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "freeze-protection-with-lp-dew-45078", + "write": true + }, + "45077": { + "title": "Use LP as freeze protection", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -100.0, + "max": 200.0, + "default": 0.0, + "name": "use-lp-as-freeze-protection-45077", + "write": true + }, + "44206": { + "title": "Auto mode, start temperature for passive cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": -200.0, + "max": 400.0, + "default": 250.0, + "name": "auto-mode-start-temperature-for-passive-cooling-44206", + "write": true + }, + "31586": { + "title": "Heating, compressor only", + "factor": 10, + "unit": "kWh", + "size": "u32", + "name": "heating-compressor-only-31586" + }, + "31584": { + "title": "Hot water, compressor only", + "factor": 10, + "unit": "kWh", + "size": "u32", + "name": "hot-water-compressor-only-31584" + }, + "31578": { + "title": "Heating, including int. add. heat", + "factor": 10, + "unit": "kWh", + "size": "u32", + "name": "heating-including-int-add-heat-31578" + }, + "31576": { + "title": "Hot water, including int. add. heat", + "factor": 10, + "unit": "kWh", + "size": "u32", + "name": "hot-water-including-int-add-heat-31576" + }, + "33801": { + "title": "Boiler temperature (BT52)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "boiler-temperature-bt52-33801" + }, + "32801": { + "title": "Temperature: HTS 1", + "factor": 10, + "unit": "\u00b0C", + "size": "s32", + "name": "temperature-hts-1-32801" + }, + "33131": { + "title": "Humidity: HTS 1", + "factor": 10, + "unit": "%RH", + "size": "s32", + "name": "humidity-hts-1-33131" + }, + "41556": { + "title": "Input AUX7", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux7-41556", + "write": true + }, + "41557": { + "title": "Input AUX8", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux8-41557", + "write": true + }, + "41558": { + "title": "Input AUX9", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 67.0, + "default": 0.0, + "name": "input-aux9-41558", + "write": true + }, + "43029": { + "title": "Immersion heater power, emergency mode", + "factor": 100, + "unit": "kW", + "size": "s16", + "min": 0.0, + "max": 4500.0, + "default": 600.0, + "name": "immersion-heater-power-emergency-mode-43029", + "write": true + }, + "43987": { + "title": "Disable emergency restart GP1", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "disable-emergency-restart-gp1-43987", + "write": true + } +} From 2a41278bfce998ac426c2a68f44883ed48e71c1d Mon Sep 17 00:00:00 2001 From: Jevgeni Kiski Date: Sat, 4 Jan 2025 17:54:27 +0200 Subject: [PATCH 2/2] Merging S1156 with S1256 (has now less registers because of that) --- nibe/data/{s1156.csv => s1156_s1256.csv} | 2 +- nibe/data/{s1156.json => s1156_s1256.json} | 0 nibe/heatpump.py | 3 ++- tests/test_heatpump.py | 5 +++++ 4 files changed, 8 insertions(+), 2 deletions(-) rename nibe/data/{s1156.csv => s1156_s1256.csv} (99%) rename nibe/data/{s1156.json => s1156_s1256.json} (100%) diff --git a/nibe/data/s1156.csv b/nibe/data/s1156_s1256.csv similarity index 99% rename from nibe/data/s1156.csv rename to nibe/data/s1156_s1256.csv index aa02585..f603361 100755 --- a/nibe/data/s1156.csv +++ b/nibe/data/s1156_s1256.csv @@ -1,4 +1,4 @@ -Title Register type Register Division factor Unit Size of variable Min value Max value Default value +Title Register type Register Division factor Unit Size of variable Min value Max value Default value Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0 Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0 Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0 diff --git a/nibe/data/s1156.json b/nibe/data/s1156_s1256.json similarity index 100% rename from nibe/data/s1156.json rename to nibe/data/s1156_s1256.json diff --git a/nibe/heatpump.py b/nibe/heatpump.py index 3631fe6..87b4d41 100644 --- a/nibe/heatpump.py +++ b/nibe/heatpump.py @@ -31,7 +31,8 @@ class Model(Enum): S1155 = "s1155_s1255", Series.S S1255 = "s1155_s1255", Series.S - S1256 = "s1155_s1255", Series.S + S1156 = "s1156_s1256", Series.S + S1256 = "s1156_s1256", Series.S F1145 = "f1145_f1245", Series.F F1245 = "f1145_f1245", Series.F diff --git a/tests/test_heatpump.py b/tests/test_heatpump.py index 77cf743..4a6576e 100644 --- a/tests/test_heatpump.py +++ b/tests/test_heatpump.py @@ -89,11 +89,14 @@ async def test_initalization_failed(self): "model,series", [ (Model.F370, Series.F), + (Model.F470, Series.F), (Model.F730, Series.F), + (Model.F750, Series.F), (Model.F1145, Series.F), (Model.F1245, Series.F), (Model.F1155, Series.F), (Model.F1255, Series.F), + (Model.F1345, Series.F), (Model.F1355, Series.F), (Model.SMO20, Series.F), (Model.SMO40, Series.F), @@ -108,7 +111,9 @@ async def test_initalization_failed(self): (Model.S735, Series.S), (Model.S1155, Series.S), (Model.S1255, Series.S), + (Model.S1156, Series.S), (Model.S1256, Series.S), + (Model.S2125, Series.S), ], ) def test_series(model: Model, series: Series):