diff --git a/nibe/data/s2125.csv b/nibe/data/s2125.csv index 85cee3f..c0ded7e 100755 --- a/nibe/data/s2125.csv +++ b/nibe/data/s2125.csv @@ -1,4 +1,4 @@ -Title Register type Register Division factor Unit Size of variable Min value Max value Default value +Title Register type Register Division factor Unit Size of variable Min value Max value Default value Current outdoor temperature (BT1) MODBUS_INPUT_REGISTER 1 10 °C 2 0 0 0 Supply line (EP23-BT2) MODBUS_INPUT_REGISTER 2 10 °C 2 0 0 0 Supply line (EP22-BT2) MODBUS_INPUT_REGISTER 3 10 °C 2 0 0 0 @@ -45,8 +45,6 @@ Room average temp. clim. system 2 (BT50) MODBUS_INPUT_REGISTER 115 10 °C 2 0 0 Room average temp. clim. system 1 (BT50) MODBUS_INPUT_REGISTER 116 10 °C 2 0 0 0 External cooling supply temperature (BT25) MODBUS_INPUT_REGISTER 119 10 °C 2 0 0 0 id:193 MODBUS_INPUT_REGISTER 128 1 4 0 0 0 -Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 -Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 Oper. mode shunt climate system 8 MODBUS_INPUT_REGISTER 129 1 4 0 0 0 Oper. mode shunt climate system 7 MODBUS_INPUT_REGISTER 130 1 4 0 0 0 Oper. mode shunt climate system 6 MODBUS_INPUT_REGISTER 131 1 4 0 0 0 @@ -57,6 +55,8 @@ Fan speed (AZ30-GQ2) MODBUS_INPUT_REGISTER 135 1 % 4 0 0 0 Fan speed (AZ30-GQ3) MODBUS_INPUT_REGISTER 136 1 % 4 0 0 0 Current hot water mode controlled by MODBUS_INPUT_REGISTER 137 1 1 0 0 0 Max. compressor frequency, heating MODBUS_INPUT_REGISTER 141 100 Hz 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 142 1 5 0 0 0 +Inverter alarm code MODBUS_INPUT_REGISTER 143 1 5 0 0 0 External adjustment climate system 8 MODBUS_INPUT_REGISTER 151 1 4 0 0 0 External adjustment climate system 7 MODBUS_INPUT_REGISTER 152 1 4 0 0 0 External adjustment climate system 6 MODBUS_INPUT_REGISTER 153 1 4 0 0 0 @@ -446,6 +446,7 @@ Climate system 4 MODBUS_HOLDING_REGISTER 144 1 4 0 1 0 Shunt controlled additional heat MODBUS_HOLDING_REGISTER 153 1 4 0 1 0 Wait time shunt, shunt controlled additional heat MODBUS_HOLDING_REGISTER 157 1 s 2 10 300 30 Step controlled additional heat accessory MODBUS_HOLDING_REGISTER 158 1 4 0 1 0 +DM start step controlled additional heat MODBUS_HOLDING_REGISTER 159 1 DM 2 -2000 -30 -400 Waiting time cooling/heating MODBUS_HOLDING_REGISTER 165 1 h 1 0 48 2 Heating start at under temp. MODBUS_HOLDING_REGISTER 166 10 °C 1 5 100 10 Cooling start at over temp. MODBUS_HOLDING_REGISTER 167 10 °C 1 5 100 30 @@ -454,6 +455,7 @@ Start active cooling DM MODBUS_HOLDING_REGISTER 173 1 DM 2 10 300 30 Permit additional heat, heating MODBUS_HOLDING_REGISTER 180 1 4 0 1 1 Permit heating MODBUS_HOLDING_REGISTER 181 1 4 0 1 1 Permit cooling MODBUS_HOLDING_REGISTER 182 1 4 0 1 1 +Auto mode, start temperature for cooling MODBUS_HOLDING_REGISTER 183 10 °C 2 150 400 250 Auto mode, stop temperature for heating MODBUS_HOLDING_REGISTER 184 10 °C 2 -200 400 170 Auto mode, additional heat stop temperature MODBUS_HOLDING_REGISTER 185 10 °C 2 -250 400 50 Auto mode filter time MODBUS_HOLDING_REGISTER 186 1 h 4 0 48 24 @@ -525,6 +527,7 @@ id:4710 MODBUS_HOLDING_REGISTER 5279 1 4 0 1 0 Input AUX6 MODBUS_HOLDING_REGISTER 767 1 4 0 68 0 Operating mode circulation pump heating heat pump 1 MODBUS_HOLDING_REGISTER 783 1 4 0 1 1 Operating mode circulation pump hot water heat pump 1 MODBUS_HOLDING_REGISTER 799 1 4 0 1 1 +Speed circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 823 1 % 4 1 100 70 Operating mode circulation pump cooling heat pump 1 MODBUS_HOLDING_REGISTER 832 1 4 0 1 1 Speed circulation pump waiting mode heat pump 1 MODBUS_HOLDING_REGISTER 841 1 % 4 1 100 30 Speed, circulation pump, standby mode (EB100) MODBUS_HOLDING_REGISTER 842 1 % 4 1 100 30 @@ -608,6 +611,7 @@ Flow sensor activated X22 MODBUS_HOLDING_REGISTER 1049 1 4 0 1 0 Max. internal additional heat SG Ready MODBUS_HOLDING_REGISTER 1052 100 kW 2 0 900 900 Limit humidity in the room, cooling climate system 1 MODBUS_HOLDING_REGISTER 1063 1 1 0 1 0 Hysteresis (OPT) MODBUS_HOLDING_REGISTER 1066 1 2 10 2000 100 +Activated (EME10) MODBUS_HOLDING_REGISTER 1068 1 4 0 1 0 PV panel affects heating (EME) MODBUS_HOLDING_REGISTER 1069 1 4 0 1 0 PV panel affects hot water (EME) MODBUS_HOLDING_REGISTER 1070 1 4 0 1 0 Delay timer EME MODBUS_HOLDING_REGISTER 1071 1 5 0 0 0 @@ -665,6 +669,7 @@ Start day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTE End day tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1281 1 4 1 31 31 Start month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1282 1 4 1 12 1 End month tariff, ext. step add. heat smart energy source MODBUS_HOLDING_REGISTER 1283 1 4 1 12 12 +Prioritise additional heat (AXC40) MODBUS_HOLDING_REGISTER 1320 1 4 0 1 0 Max difference, SES priority 1 energy source MODBUS_HOLDING_REGISTER 1326 10 °C 2 10 250 100 Max difference, SES lower priority energy source MODBUS_HOLDING_REGISTER 1327 10 °C 2 10 250 70 Installed (EB101) MODBUS_HOLDING_REGISTER 1550 1 4 0 1 1 @@ -772,6 +777,7 @@ Factor MODBUS_HOLDING_REGISTER 3033 1 4 1 10 5 id:10881 MODBUS_HOLDING_REGISTER 3062 1 4 0 1 0 id:10890 MODBUS_HOLDING_REGISTER 3063 1 4 0 1 0 Hot water start (BT5) MODBUS_INPUT_REGISTER 2014 10 °C 2 0 0 0 +Pump: Heating medium (GP6) MODBUS_INPUT_REGISTER 2128 1 4 0 0 0 id:12332 MODBUS_HOLDING_REGISTER 2767 1 2 -32768 32767 -32768 id:12333 MODBUS_HOLDING_REGISTER 2768 1 2 -32768 32767 -32768 id:12334 MODBUS_HOLDING_REGISTER 2769 1 2 -32768 32767 -32768 @@ -1472,6 +1478,8 @@ id:55082 MODBUS_HOLDING_REGISTER 2883 1 4 0 1 0 id:55083 MODBUS_HOLDING_REGISTER 2884 1 4 0 1 0 Immersion heater power, emergency mode MODBUS_HOLDING_REGISTER 3028 100 kW 2 0 4500 600 Disable emergency restart GP1 MODBUS_HOLDING_REGISTER 3986 1 4 0 1 0 +Return line (AZ2-BT69) MODBUS_INPUT_REGISTER 2190 10 °C 2 0 0 0 +Supply line (AZ2-BT68) MODBUS_INPUT_REGISTER 2191 10 °C 2 0 0 0 "EEV Control Mode (EB101)" MODBUS_INPUT_REGISTER 2413 1 4 0 0 0 "EEV State (EB101)" MODBUS_INPUT_REGISTER 2421 1 4 0 0 0 id:55495 MODBUS_HOLDING_REGISTER 5550 1 4 0 1 0 diff --git a/nibe/data/s2125.json b/nibe/data/s2125.json index c24dd6d..7a1c26c 100644 --- a/nibe/data/s2125.json +++ b/nibe/data/s2125.json @@ -263,18 +263,6 @@ "size": "s16", "name": "external-cooling-supply-temperature-bt25-30120" }, - "30143": { - "title": "Inverter alarm code", - "factor": 1, - "size": "u16", - "name": "inverter-alarm-code-30143" - }, - "30144": { - "title": "Inverter alarm code", - "factor": 1, - "size": "u16", - "name": "inverter-alarm-code-30144" - }, "30130": { "title": "Oper. mode shunt climate system 8", "factor": 1, @@ -332,6 +320,18 @@ "size": "u16", "name": "max-compressor-frequency-heating-30142" }, + "30143": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30143" + }, + "30144": { + "title": "Inverter alarm code", + "factor": 1, + "size": "u16", + "name": "inverter-alarm-code-30144" + }, "30152": { "title": "External adjustment climate system 8", "factor": 1, @@ -3071,6 +3071,17 @@ "name": "step-controlled-additional-heat-accessory-40159", "write": true }, + "40160": { + "title": "DM start step controlled additional heat", + "factor": 1, + "unit": "DM", + "size": "s16", + "min": -2000.0, + "max": -30.0, + "default": -400.0, + "name": "dm-start-step-controlled-additional-heat-40160", + "write": true + }, "40166": { "title": "Waiting time cooling/heating", "factor": 1, @@ -3155,6 +3166,17 @@ "name": "permit-cooling-40183", "write": true }, + "40184": { + "title": "Auto mode, start temperature for cooling", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "min": 150.0, + "max": 400.0, + "default": 250.0, + "name": "auto-mode-start-temperature-for-cooling-40184", + "write": true + }, "40185": { "title": "Auto mode, stop temperature for heating", "factor": 10, @@ -3693,6 +3715,17 @@ "name": "operating-mode-circulation-pump-hot-water-heat-pump-1-40800", "write": true }, + "40824": { + "title": "Speed circulation pump cooling heat pump 1", + "factor": 1, + "unit": "%", + "size": "u8", + "min": 1.0, + "max": 100.0, + "default": 70.0, + "name": "speed-circulation-pump-cooling-heat-pump-1-40824", + "write": true + }, "40833": { "title": "Operating mode circulation pump cooling heat pump 1", "factor": 1, @@ -4495,6 +4528,16 @@ "name": "hysteresis-opt-41067", "write": true }, + "41069": { + "title": "Activated (EME10)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "activated-eme10-41069", + "write": true + }, "41070": { "title": "PV panel affects heating (EME)", "factor": 1, @@ -5059,6 +5102,16 @@ "name": "end-month-tariff-ext-step-add-heat-smart-energy-source-41284", "write": true }, + "41321": { + "title": "Prioritise additional heat (AXC40)", + "factor": 1, + "size": "u8", + "min": 0.0, + "max": 1.0, + "default": 0.0, + "name": "prioritise-additional-heat-axc40-41321", + "write": true + }, "41327": { "title": "Max difference, SES priority 1 energy source", "factor": 10, @@ -5689,6 +5742,12 @@ "size": "s16", "name": "hot-water-start-bt5-32015" }, + "32129": { + "title": "Pump: Heating medium (GP6)", + "factor": 1, + "size": "u8", + "name": "pump-heating-medium-gp6-32129" + }, "43089": { "title": "Period", "factor": 1, @@ -7220,6 +7279,20 @@ "name": "disable-emergency-restart-gp1-43987", "write": true }, + "32191": { + "title": "Return line (AZ2-BT69)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "return-line-az2-bt69-32191" + }, + "32192": { + "title": "Supply line (AZ2-BT68)", + "factor": 10, + "unit": "\u00b0C", + "size": "s16", + "name": "supply-line-az2-bt68-32192" + }, "32414": { "title": "EEV Control Mode (EB101)", "factor": 1,