import json
import paho.mqtt.client as mqtt
import logging
class MQTTPublisher:
def __init__(self, config, logger):
self.logger = logger
self.client = mqtt.Client()
self.mqtt_broker = config.mqtt_broker
self.mqtt_port = config.mqtt_port
self.base_topic = config.mqtt_topic
self.device_name = "landisgyr_e360"
self.device_id = "landisgyr_e360_meter"
self.client.on_connect = self.on_connect
self.client.connect(self.mqtt_broker, self.mqtt_port, 60)
self.client.loop_start()
def on_connect(self, client, userdata, flags, rc):
self.logger.info(f"Connected with result code {rc}")
# Publish discovery messages
self.publish_discovery_messages()
# Publish online state
self.publish_availability('online')
def publish_discovery_messages(self):
discovery_prefix = "homeassistant/sensor/landisgyr_e360"
sensors = [
{"name": "Total Active Energy Import", "unique_id": "total_active_energy_fwd", "unit_of_measurement": "kWh", "icon": "mdi:flash", "state_class": "total_increasing", "device_class": "energy"},
{"name": "Total Active Energy Export", "unique_id": "total_active_energy_rev", "unit_of_measurement": "kWh", "icon": "mdi:flash", "state_class": "total_increasing", "device_class": "energy"},
{"name": "Total Reactive Energy Import", "unique_id": "reactive_energy_fwd", "unit_of_measurement": "varh", "icon": "mdi:flash", "state_class": "total_increasing", "device_class": "energy"},
{"name": "Total Reactive Energy Export", "unique_id": "rective_energy_rev", "unit_of_measurement": "varh", "icon": "mdi:flash", "state_class": "total_increasing", "device_class": "energy"},
{"name": "Active Power Import", "unique_id": "active_power_fwd", "unit_of_measurement": "kW", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Active Power Export", "unique_id": "active_power_rev", "unit_of_measurement": "kW", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Active Power L1", "unique_id": "active_power_l1_fwd", "unit_of_measurement": "kW", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Active Power L2", "unique_id": "active_power_l2_fwd", "unit_of_measurement": "kW", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Active Power L3", "unique_id": "active_power_l3_fwd", "unit_of_measurement": "kW", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Reactive Power L1", "unique_id": "reactive_power_l1_imp", "unit_of_measurement": "var", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Reactive Power L2", "unique_id": "reactive_power_l2_imp", "unit_of_measurement": "var", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Reactive Power L3", "unique_id": "reactive_power_l3_imp", "unit_of_measurement": "var", "icon": "mdi:flash", "state_class": "measurement", "device_class": "power"},
{"name": "Voltage L1", "unique_id": "voltage_rms_l1", "unit_of_measurement": "V", "icon": "mdi:flash", "state_class": "measurement", "device_class": "voltage"},
{"name": "Voltage L2", "unique_id": "voltage_rms_l2", "unit_of_measurement": "V", "icon": "mdi:flash", "state_class": "measurement", "device_class": "voltage"},
{"name": "Voltage L3", "unique_id": "voltage_rms_l3", "unit_of_measurement": "V", "icon": "mdi:flash", "state_class": "measurement", "device_class": "voltage"},
{"name": "Current L1", "unique_id": "current_rms_l1", "unit_of_measurement": "A", "icon": "mdi:flash", "state_class": "measurement", "device_class": "current"},
{"name": "Current L2", "unique_id": "current_rms_l2", "unit_of_measurement": "A", "icon": "mdi:flash", "state_class": "measurement", "device_class": "current"},
{"name": "Current L3", "unique_id": "current_rms_l3", "unit_of_measurement": "A", "icon": "mdi:flash", "state_class": "measurement", "device_class": "current"}
]
for sensor in sensors:
payload = {
"name": sensor['name'],
"state_topic": f"{self.base_topic}/state",
"unique_id": f"{self.device_id}_{sensor['unique_id']}",
"unit_of_measurement": sensor["unit_of_measurement"],
"availability_topic": f"{self.base_topic}/availability",
"device": {
"identifiers": [self.device_id],
"name": "Landis+Gyr E360",
"model": "E360",
"manufacturer": "Landis+Gyr"
},
"icon": sensor["icon"],
"value_template": f"{{{{ value_json.{sensor['unique_id']} }}}}",
"state_class": sensor["state_class"],
"device_class": sensor["device_class"]
}
topic = f"{discovery_prefix}/{sensor['unique_id']}/config"
self.client.publish(topic, json.dumps(payload), retain=True)
def publish(self, data):
json_message = json.dumps({key: value["value"] for key, value in data.items()})
self.client.publish(f"{self.base_topic}/state", json_message)
def publish_availability(self, state):
self.client.publish(f"{self.base_topic}/availability", state, 0, True)
def disconnect(self):
# Publish offline state
self.publish_availability('offline')
# Stop loop
self.client.loop_stop()
# Disconnect MQTT
self.client.disconnect()