Out-of-Band Management Guide

Scope: Consolidated access and monitoring for all out-of-band infrastructure management systems. Updated: 2026-04-30


Overview

This homelab has a comprehensive out-of-band (OOB) management infrastructure that enables remote access, power control, and monitoring even when the primary network or Kubernetes cluster is down.

Architecture

┌─────────────────────────────────────────────────────────────┐
│                    OOB Management Stack                      │
├─────────────────────────────────────────────────────────────┤
│                                                               │
│  ┌──────────────┐  ┌──────────────┐  ┌──────────────┐      │
│  │   PiKVM      │  │     PDUs     │  │     UPS      │      │
│  │   (kvm01)    │  │  (pdu01/02)  │  │  (ups01/02)  │      │
│  │              │  │              │  │              │      │
│  │ • Video/KVM  │  │ • Power Ctrl │  │ • Battery    │      │
│  │ • Screenshot │  │ • SNMP       │  │ • Load Mon   │      │
│  │ • OCR        │  │ • Reboot     │  │ • SNMP       │      │
│  └──────────────┘  └──────────────┘  └──────────────┘      │
│                                                               │
│  ┌──────────────┐  ┌──────────────┐                         │
│  │  ConsolePi   │  │   TESmart    │                         │
│  │  (pi02/03)   │  │  16-port KVM │                         │
│  │              │  │              │                         │
│  │ • Serial     │  │ • HDMI Sw    │                         │
│  │ • Core Sw    │  │ • GPIO       │                         │
│  └──────────────┘  └──────────────┘                         │
│                                                               │
└─────────────────────────────────────────────────────────────┘
           │                    │                    │
           ▼                    ▼                    ▼
    ┌─────────────┐     ┌──────────────┐    ┌──────────────┐
    │   Gatus     │     │  Prometheus  │    │   Grafana    │
    │ Status Page │     │   Metrics    │    │  Dashboards  │
    └─────────────┘     └──────────────┘    └──────────────┘

Components

1. PiKVM (kvm01)

Location: Rack01 (U-mounted) IP: kvm01.in.homeops.ca (192.168.99.51) Purpose: Remote keyboard/video/mouse access to any server

Features

  • Remote KVM: Full keyboard/video/mouse control over IP
  • Mass Storage: Virtual USB drive mounting for ISO/recovery
  • GPIO Control: Wake-on-LAN via GPIO outputs
  • TESmart Integration: Automated HDMI port switching
  • Screenshot/OCR: Capture and analyze screen output

Access Methods

Web UI
# Direct browser access
https://kvm01.in.homeops.ca

# Credentials in .private/pikvm.env
CLI (via scripts)
# Switch KVM to a specific node
just infra kvm-switch k8s01

# Take screenshot
just infra snapshot screenshot.jpg

# OCR text from screen
just infra ocr

# Send Wake-on-LAN
just infra wol k8s04

# Combined: switch + screenshot
just infra console k8s03

Node Mapping (TESmart Ports)

Port Node Type
0 nas01 NAS
1 k8s01 Control Plane
2 k8s02 Control Plane
3 k8s03 Control Plane
4 k8s04 Worker
5 k8s05 Worker
6 k8s06 Worker
7 pi01 Raspberry Pi
8 pi02 ConsolePi
9 pi03 ConsolePi
10 pi04 Raspberry Pi
11 pve01 Proxmox
12 fw01 OPNsense

Scripts

  • Main: /home/runner/work/home-ops/home-ops/scripts/infra-pikvm.sh
  • Justfile: just infra kvm-* recipes
  • API: HTTPS with X-KVMD-User and X-KVMD-Passwd headers

2. PDUs (Power Distribution Units)

Devices:

  • pdu01: 192.168.99.15 (CyberPower PDU41001)
  • pdu02: 192.168.99.16 (CyberPower PDU41001)

Purpose: Remote power control via SNMP

Outlet Mapping

PDU01 (192.168.99.15):

Outlet Device Purpose
1 k8s01 Control Plane Node
2 k8s02 Control Plane Node
3 k8s03 Control Plane Node
4 nas01 NAS (PSU1)
5 core01-u1 Core Switch U1
6 fw01 OPNsense Firewall

PDU02 (192.168.99.16):

Outlet Device Purpose
1 k8s04 Worker Node
2 k8s05 Worker Node
3 k8s06 Worker Node
4 nas01-psu2 NAS (PSU2)
5 core01-u2 Core Switch U2

Access Methods

CLI (Recommended)
# Power on a node
just infra pdu-on k8s05

# Power off a node (with confirmation)
just infra pdu-off k8s02

# Power cycle a node (with confirmation)
just infra pdu-reboot k8s03

# Check outlet status
just infra pdu-status k8s01

# Check all outlets
just infra pdu-status

# Hard reboot (PDU cycle + wait for boot)
just infra hard-reboot k8s04
SNMP Direct
# Check outlet status
snmpget -v 2c -c private 192.168.99.15 .1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4.1

# Power on outlet 1
snmpset -v 2c -c private 192.168.99.15 .1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4.1 integer 1

# Power off outlet 1
snmpset -v 2c -c private 192.168.99.15 .1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4.1 integer 2

# Reboot outlet 1
snmpset -v 2c -c private 192.168.99.15 .1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4.1 integer 3

SNMP Values:

  • 1 = ON
  • 2 = OFF
  • 3 = REBOOT
  • 4 = CANCEL

Scripts

  • Main: /home/runner/work/home-ops/home-ops/scripts/infra-pdu.sh
  • Justfile: just infra pdu-* recipes
  • SNMP OID: .1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4.{outlet}

Safety Features

  • Confirmation prompts for power-off/reboot
  • Visual warnings for destructive operations
  • gum integration for better UX (falls back to read)

3. UPS (Uninterruptible Power Supply)

Devices:

  • ups01: 192.168.99.11
  • ups02: 192.168.99.12

Purpose: Battery backup and power quality monitoring

Monitoring

SNMP Metrics

Monitored via SNMP Exporter in Kubernetes:

Targets:
  - ups01 (192.168.99.11)
  - ups02 (192.168.99.12)

Key Metrics:
  - upsBasicBatteryTimeOnBattery_seconds - Time running on battery
  - upsAdvBattery_needsreplacing - Battery replacement flag
  - upsAdvOutputActivePower - Current power output (watts)
  - upsAdvBatteryCapacity - Battery charge level (%)
  - upsAdvConfigRatedOutputPower - Max rated power
Alerts
  • UPSOnBattery (critical): UPS running on battery > 60 seconds
  • UPSReplaceBattery (critical): Battery needs replacement
  • UPSUnreachable (warning): SNMP monitoring unavailable
  • UPSLowBattery (warning): Battery capacity < 50%
  • UPSHighLoad (warning): Load > 80% of rated capacity
Grafana Dashboard
Power Usage Badge

Current cluster power consumption is exposed via Kromgo:

Metric: cluster_power_usage
Query: avg(upsAdvOutputActivePower)
Colors:
  - Green: 0-400w
  - Orange: 401-750w
  - Red: 751-9999w

4. ConsolePi (Serial Console)

Devices:

  • pi02: 192.168.42.22 (→ Core01-U1 serial)
  • pi03: 192.168.42.23 (→ Core01-U2 serial)

Purpose: Serial console access to core network switches

Access

# SSH to ConsolePi
ssh pi@192.168.42.22

# Connect to switch serial console
# (USB-to-serial adapters auto-detected by ConsolePi)
screen /dev/ttyUSB0 9600

# Or use ConsolePi menu
consolepi-menu

Connected Devices

  • pi02 → Core01-U1: Primary core switch (Brocade ICX 6610-48P)
  • pi03 → Core01-U2: Secondary core switch (Brocade ICX 6610-48P stack member)

Use Cases

  • Initial switch configuration
  • Recovery from network misconfigurations
  • Firmware updates
  • Stack management troubleshooting
  • Emergency access when network is down

Unified Monitoring

Gatus Status Page

All OOB devices are monitored on the unified status page:

URL: https://status.homeops.ca

OOB Management Group:

  • PiKVM (kvm01) - HTTPS health check
  • PDU01 - TCP connect to SNMP port (161)
  • PDU02 - TCP connect to SNMP port (161)
  • UPS01 - TCP connect to SNMP port (161)
  • UPS02 - TCP connect to SNMP port (161)
  • ConsolePi (pi02) - TCP connect to SSH (22)
  • ConsolePi (pi03) - TCP connect to SSH (22)

Check Intervals:

  • PiKVM: 1 minute
  • PDUs/UPS: 2 minutes
  • ConsolePi: 2 minutes

Blackbox Exporter (ICMP)

LAN connectivity probes monitor OOB devices via ICMP:

Targets:
  - kvm01.in.homeops.ca
  - pdu01.in.homeops.ca
  - pdu02.in.homeops.ca
  - ups01.in.homeops.ca
  - ups02.in.homeops.ca

Prometheus & Alertmanager

Metrics Collection:

  • SNMP Exporter → PDU/UPS SNMP data
  • Blackbox Exporter → ICMP reachability
  • Gatus → HTTP/TCP endpoint health

Alert Rules:

  • PDU/UPS unreachability
  • UPS battery status
  • UPS on battery power
  • UPS high load

Alertmanager URL: https://alertmanager.homeops.ca


Common Workflows

Emergency Server Access (Complete Failure)

If the server is completely unresponsive:

# 1. Switch KVM to the server
just infra kvm-switch k8s04

# 2. Check screen output (via PiKVM web UI or screenshot)
just infra snapshot

# 3. If hung/frozen, hard reboot via PDU
just infra hard-reboot k8s04

# 4. Monitor boot via KVM
# (screen updates visible in PiKVM web UI)

Network Switch Recovery

If network is down and you need switch console:

# 1. SSH to ConsolePi
ssh pi@192.168.42.22

# 2. Connect to serial console
screen /dev/ttyUSB0 9600

# 3. Access switch CLI
# (usually auto-connects, or press Enter)

Power Monitoring During Outage

# Check if UPS is on battery
curl -sk https://prometheus.homeops.ca/api/v1/query?query=upsBasicBatteryTimeOnBattery_seconds | jq

# Check current power draw
curl -sk https://prometheus.homeops.ca/api/v1/query?query=upsAdvOutputActivePower | jq

# Check battery capacity
curl -sk https://prometheus.homeops.ca/api/v1/query?query=upsAdvBatteryCapacity | jq

Graceful Cluster Shutdown (Extended Outage)

If UPS is on battery and runtime is limited:

# 1. Check estimated runtime
# (via Grafana UPS dashboard or SNMP)

# 2. If < 10 minutes, initiate graceful shutdown
kubectl drain k8s04 k8s05 k8s06 --ignore-daemonsets --delete-emptydir-data

# 3. Wait for workloads to drain (2-3 minutes)

# 4. Power off workers first
just infra pdu-off k8s04
just infra pdu-off k8s05
just infra pdu-off k8s06

# 5. Power off control plane (last)
just infra pdu-off k8s01
just infra pdu-off k8s02
just infra pdu-off k8s03

Firmware/BIOS Update via KVM

# 1. Switch to the target node
just infra kvm-switch k8s02

# 2. Access PiKVM web UI
# https://kvm01.in.homeops.ca

# 3. Mount ISO via Mass Storage Device
# (Upload ISO in PiKVM web UI → Drive menu)

# 4. Reboot into BIOS/UEFI
just infra pdu-reboot k8s02

# 5. Use KVM to control BIOS/boot menu
# (Full keyboard/mouse via web UI)

Network Architecture

Management VLAN

All OOB devices reside on VLAN 99 (Management):

Subnet: 192.168.99.0/24 Gateway: 192.168.99.4 (Brocade Core01)

OOB Device IPs:

Device IP MAC
ups01 192.168.99.11 (SNMP)
ups02 192.168.99.12 (SNMP)
pdu01 192.168.99.15 (SNMP)
pdu02 192.168.99.16 (SNMP)
kvm01 192.168.99.51 (HTTPS/API)
tesmart 192.168.99.92 (GPIO via PiKVM)

Note: ConsolePi devices (pi02/pi03) are on Server VLAN (192.168.42.0/24) for direct SSH access.

DNS Resolution

# Internal DNS (Unbound on fw01)
kvm01.in.homeops.ca → 192.168.99.51
pdu01.in.homeops.ca → 192.168.99.15
pdu02.in.homeops.ca → 192.168.99.16
ups01.in.homeops.ca → 192.168.99.11
ups02.in.homeops.ca → 192.168.99.12

Firewall Rules

Management VLAN (99) is accessible from:

  • Server VLAN (42) - for Kubernetes SNMP monitoring
  • Workstation VLAN (10) - for admin access

fw01 (OPNsense) rules:

  • Allow Server → Management (SNMP, HTTPS, SSH)
  • Allow Workstation → Management (all)
  • Deny all other inbound to Management

Security Considerations

Authentication

PiKVM:

  • Username: admin
  • Password: Stored in .private/pikvm.env (gitignored)
  • HTTPS only (self-signed cert, insecure: true in Gatus)

PDUs:

  • SNMP Community: Stored in .private/cyberpower.env or PDU_COMMUNITY env var
  • Default: "private" (should be changed in production)
  • SNMPv2c (plaintext - network isolation is critical)

ConsolePi:

  • SSH key-based authentication
  • User: pi
  • Direct serial access (no password on serial console)

Network Isolation

  • Management VLAN is firewalled from Guest and IoT VLANs
  • PDU/UPS use SNMPv2c (no encryption) - trust boundary at VLAN edge
  • PiKVM uses HTTPS but self-signed cert
  • Serial console has no authentication (physical security critical)

Access Control Recommendations

  1. PiKVM: Integrate with centralized auth (LDAP/SSO) when #3064 is implemented
  2. PDUs: Upgrade to SNMPv3 with authentication/encryption
  3. UPS: Consider moving to NUT (Network UPS Tools) in Kubernetes for encrypted monitoring
  4. ConsolePi: Use bastion/jump host for access, disable direct SSH from untrusted VLANs

Troubleshooting

PiKVM Unreachable

# 1. Check network connectivity
ping kvm01.in.homeops.ca

# 2. Check if PiKVM is powered
# (should be on UPS with auto-start on power restore)

# 3. Check switch port
# (Management VLAN 99 tagged on appropriate port)

# 4. Physical access to PiKVM
# (HDMI output shows local console)

PDU SNMP Not Responding

# 1. Test SNMP connectivity
snmpget -v 2c -c private pdu01.in.homeops.ca .1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4.1

# 2. Verify PDU is powered
# (check UPS dashboard for outlet status)

# 3. Check PDU management IP config
# (may need factory reset via physical button)

# 4. Verify SNMP community string
# (check .private/cyberpower.env)

UPS Metrics Missing

# 1. Check SNMP Exporter pod
kubectl get pods -n observability -l app.kubernetes.io/name=snmp-exporter

# 2. Check ServiceMonitor targets
kubectl get servicemonitor -n observability snmp-exporter -o yaml

# 3. Check Prometheus targets
# https://prometheus.homeops.ca/targets
# (look for snmp-exporter jobs)

# 4. Manual SNMP test
snmpwalk -v 2c -c public_v2 ups01.in.homeops.ca .1.3.6.1.4.1.318.1.1.1

ConsolePi Not Accessible

# 1. Check SSH connectivity
ssh -v pi@192.168.42.22

# 2. Check if ConsolePi is running
# (should auto-start on power, check via PiKVM if needed)

# 3. Verify USB-to-serial adapter detected
# (should appear as /dev/ttyUSB0 on ConsolePi)

# 4. Check switch serial cable
# (RJ45 to DB9 console cable properly connected)

Future Improvements

Planned (Dependencies)

  • #3054: VLAN interfaces for OOB network access

    • Add bond0.99 interfaces on Talos nodes for direct Management VLAN access
    • Enable node-level access to PDU/UPS without routing through fw01
  • #3064: Centralized authentication

    • Integrate PiKVM with SSO (Authelia/LLDAP)
    • Standardize credentials across all OOB devices
    • MFA for privileged operations (power control, console access)

Under Consideration

NUT (Network UPS Tools) Migration:

  • Move UPS monitoring from SNMP Exporter to dedicated NUT server
  • Run nut-server in Kubernetes (DaemonSet or Deployment)
  • Encrypted UPS protocol instead of SNMP
  • Automatic shutdown orchestration on critical battery

PDU Monitoring Enhancement:

  • Per-outlet power monitoring (if PDUs support it)
  • Outlet-level alerts (individual outlet failures)
  • Power usage trending per device

Serial Console Aggregation:

  • Consolidate ConsolePi functionality into single device or cluster-based solution
  • Serial-over-IP for all critical infrastructure (switches, firewall, NAS)

Automated Recovery Workflows:

  • Health check → Auto-remediation via PDU reboot
  • Integration with Alertmanager for power cycling failed nodes
  • Safe guards: backoff, max retries, manual approval gates

Web Dashboard:

  • Unified web UI for all OOB operations (KVM, power, serial)
  • Alternative to vendor-specific UIs (PiKVM, PDU web interfaces)
  • Audit logging for all OOB actions

Related Documentation


Quick Reference Card

Power Control

just infra pdu-status              # Check all PDU outlets
just infra pdu-on <node>           # Power on
just infra pdu-off <node>          # Power off (DANGEROUS)
just infra pdu-reboot <node>       # Power cycle
just infra hard-reboot <node>      # PDU reboot + wait

KVM Access

just infra kvm-switch <node>       # Switch HDMI
just infra wol <node>              # Wake-on-LAN
just infra snapshot [file]         # Screenshot
just infra ocr                     # OCR screen text
just infra console <node>          # Switch + screenshot

Serial Console

ssh pi@192.168.42.22               # ConsolePi (Core01-U1)
ssh pi@192.168.42.23               # ConsolePi (Core01-U2)
screen /dev/ttyUSB0 9600           # Serial session

Monitoring

https://status.homeops.ca          # Gatus unified status
https://grafana.homeops.ca/d/apc-ups # UPS dashboard
https://prometheus.homeops.ca/targets # SNMP targets
https://alertmanager.homeops.ca    # Active alerts

Last Updated: 2026-04-30 Maintainer: @osnabrugge Related Issues: #3054 (VLAN), #3064 (Auth), Current issue (Consolidation)