Skip to content

Auto Detect Module 2024 Q1 #267

@Alessandro99

Description

@Alessandro99

When using the 24.5.0 release of this Custom Device with VeriStand 2024 Q1, the Auto-Detect button launches a VI that shows as broken. When clicking the broken run arrow, the indication is that nNIBlueBus_nCrioFixed_nRefnum.dll cannot be loaded.

221994944-10eace2b-ae28-4a61-a172-de7ad04b46fd

To Reproduce

  1. Create an instance of the Custom Device using VS 2024 Q1
  2. Click Auto-Detect Modules from the main page

Workaround

Navigate to: "C:\Program Files\NI\LVAddons\crio64\1\resource", copy the nNIBlueBus_nCrioFixed_nRefnum.dll (dimension 332kB).
Paste it in substitution of nNIBlueBus_nCrioFixed_nRefnum.dll (dimension 257kB) in C:\Program Files (x86)\National Instruments\Shared\LabVIEW Run-Time\2022.

Restart Veristand, try to Auto Detect module another time and check in the folder C:\Users\Public\Documents\National Instruments\NI VeriStand 2024\Custom Devices\Scan Engine\Applications\data there is nNIBlueBus_nCrioFixed_nRefnum.dll (dimension 332kB).

Screenshots
Cattura

This VI generates path of LV2022 that contains an older version of nNIBlueBus_nCrioFixed_nRefnum.dll

Cattura1

Cattura2

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't working

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions