Notifications
You must be signed in to change notification settings - Fork 41
Feb 29th bug? #110
Copy link
Copy link
Open
Description
What did you do?
./flexlm_exporter --path.lmutil="/opt/ansys_inc/shared_files/licensing/linx64/lmutil" --path.config="/etc/flexlm-exporter/flexlm-exporter.yml" --web.telemetry-path="/metrics"
What did you expect to see?
valid data for processing in prometheus/grafana
What did you see instead? Under which circumstances?
ts=2024-02-29T12:43:32.719Z caller=lmstat.go:579 level=error collector=lmstat couldnotconvert=0001-01-01T00:00:00Z tounixtime:="parsing time "2023-02-29T13:18:00Z": day out of range"
ts=2024-02-29T12:43:32.719Z caller=lmstat.go:579 level=error collector=lmstat couldnotconvert=0001-01-01T00:00:00Z tounixtime:="parsing time "2023-02-29T12:50:00Z": day out of range"
System information
Linux 4.18.0-477.27.1.el8_8.x86_64 x86_64
FlexLM Server information
me@my-machine:/tmp # /opt/ansys_inc/shared_files/licensing/linx64/lmutil lmstat -f cfd_solve_level2 -c 1055@my-server
lmutil - Copyright (c) 1989-2009 Flexera Software, Inc. All Rights Reserved.
Flexible License Manager status on Thu 2/29/2024 14:52
License server status: 1055@my-server
License file(s) on my-server: C:\License\ANSYS\Shared Files\Licensing\license_files\ansyslmd.lic:
my-server: license server UP (MASTER) v11.19
Vendor daemon status (on my-server):
ansyslmd: UP v11.19
Feature usage info:
Users of cfd_solve_level2: (Total of 47 licenses issued; Total of 17 licenses in use)
"cfd_solve_level2" v9999.9999, vendor: ansyslmd
floating license
xxx node1.mydomain node1 114089 (v2022.1114) (my-server/1055 23401), start Thu 2/29 11:30
xxx node2.mydomain node2 457555 (v2021.0512) (my-server/1055 5701), start Thu 2/29 11:29
xxx node3.mydomain node3 30229 (v2020.0507) (my-server/1055 10602), start Thu 2/29 11:44
xxx node4.mydomain node4 11894 (v2022.1114) (my-server/1055 22008), start Thu 2/29 14:35
xxx node5.mydomain node5 11873 (v2022.1114) (my-server/1055 23217), start Thu 2/29 14:35
xxx node6.mydomain node6 30902 (v2022.1114) (my-server/1055 12213), start Thu 2/29 14:35
xxx node7.mydomain node7 42723 (v2022.1114) (my-server/1055 21811), start Thu 2/29 14:40
xxx node8.mydomain node8 91866 (v2022.1114) (my-server/1055 19907), start Thu 2/29 14:40
....
FlexLM Exporter version
flexlm_exporter, version 0.0.12-3-g4f401f9 (branch: main, revision: 4f401f91858c4843db764267364f3432f7cfbd9e)
build user: colleague@his-machine
build date: 20240229-12:35:33
go version: go1.21.6
platform: linux/amd64
tags: netgo static_build
FlexLM Exporter configuration file
licenses:
- name: app1
license_server: 1055@my-server
features_to_include: cfd_solve_level2
monitor_users: True
monitor_reservations: True
monitor_versions: FalseLogs
No response
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
No labels