diff --git a/Buildings/Resources/Scripts/Dymola/ConvertBuildings_from_3.0_to_4.0.mos b/Buildings/Resources/Scripts/Dymola/ConvertBuildings_from_3.0_to_4.0.mos index fc1c94e80a2..41106cdc745 100644 --- a/Buildings/Resources/Scripts/Dymola/ConvertBuildings_from_3.0_to_4.0.mos +++ b/Buildings/Resources/Scripts/Dymola/ConvertBuildings_from_3.0_to_4.0.mos @@ -10,12 +10,49 @@ convertElement("Buildings.Fluid.Movers.BaseClasses.PartialFlowMachine", "filteredSpeed", "use_inputFilter") convertElement("Buildings.Fluid.Actuators.BaseClasses.ActuatorSignal", "filteredOpening", "use_inputFilter") - +convertElement("Buildings.Fluid.Actuators.Valves.ThreeWayEqualPercentageLinear", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Valves.ThreeWayLinear", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Valves.TwoWayEqualPercentage", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Valves.TwoWayLinear", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Valves.TwoWayPressureIndependent", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Valves.TwoWayQuickOpening", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Valves.TwoWayTable", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Dampers.Exponential", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Dampers.MixingBox", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Dampers.MixingBoxMinimumFlow", + "filteredOpening", "use_inputFilter") +convertElement("Buildings.Fluid.Actuators.Dampers.VAVBoxExponential", + "filteredOpening", "use_inputFilter") // Refactoring of damper +convertModifiers("Buildings.Fluid.Actuators.Dampers.Exponential", + {"A"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBox", + {"A"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBoxMinimumFlow", + {"A"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.VAVBoxExponential", + {"A"}, fill("",0), true); convertModifiers("Buildings.Fluid.Actuators.BaseClasses.PartialDamperExponential", {"A"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.Exponential", + {"use_v_nominal"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBox", + {"use_v_nominal"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBoxMinimumFlow", + {"use_v_nominal"}, fill("",0), true); +convertModifiers("Buildings.Fluid.Actuators.Dampers.VAVBoxExponential", + {"use_v_nominal"}, fill("",0), true); convertModifiers("Buildings.Fluid.Actuators.BaseClasses.PartialDamperExponential", {"use_v_nominal"}, fill("",0), true); @@ -23,9 +60,6 @@ convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBoxMinimumFlow", {"AOutMin"}, fill("",0), true); convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBox", {"AOut", "AExh", "ARec"}, fill("",0), true); -convertModifiers("Buildings.Fluid.Actuators.Dampers.MixingBox", - {"use_v_nominal"}, fill("",0), true); - // Refactoring of DX coil class hierarchy convertClass("Buildings.Fluid.HeatExchangers.DXCoils.Data.DoubleSpeed",