diff --git a/.travis.yml b/.travis.yml index 06e46f8c1f5..ef94a471e11 100644 --- a/.travis.yml +++ b/.travis.yml @@ -17,6 +17,8 @@ services: env: - TEST_ARG="make test-documentation test-experiment-setup test-autogenerated-files" + - TEST_ARG="make test-dymola PACKAGE=Buildings.Air" + - TEST_ARG="make test-dymola PACKAGE=Buildings.Examples" - TEST_ARG="make test-dymola PACKAGE=Buildings.ThermalZones.Detailed.{BaseClasses,Constructions,Examples}" - TEST_ARG="make test-dymola PACKAGE=Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx" - TEST_ARG="make test-dymola PACKAGE=Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx" @@ -30,7 +32,6 @@ env: - TEST_ARG="make test-dymola PACKAGE=Buildings.ThermalZones.ReducedOrder" - TEST_ARG="make test-dymola PACKAGE=Buildings.Electrical" - TEST_ARG="make test-dymola PACKAGE=Buildings.{Airflow,BoundaryConditions,Controls}" - - TEST_ARG="make test-dymola PACKAGE=Buildings.{Air,Examples}" - TEST_ARG="make test-dymola PACKAGE=Buildings.HeatTransfer" - TEST_ARG="make test-dymola PACKAGE=Buildings.Media" - TEST_ARG="make test-dymola PACKAGE=Buildings.Utilities" diff --git a/Buildings/Applications/DataCenters/ChillerCooled/Examples/IntegratedPrimaryLoadSideEconomizer.mo b/Buildings/Applications/DataCenters/ChillerCooled/Examples/IntegratedPrimaryLoadSideEconomizer.mo index 014275e387e..eddd9689505 100644 --- a/Buildings/Applications/DataCenters/ChillerCooled/Examples/IntegratedPrimaryLoadSideEconomizer.mo +++ b/Buildings/Applications/DataCenters/ChillerCooled/Examples/IntegratedPrimaryLoadSideEconomizer.mo @@ -5,13 +5,13 @@ model IntegratedPrimaryLoadSideEconomizer extends Buildings.Applications.DataCenters.ChillerCooled.Examples.BaseClasses.PostProcess( freCooSig( - y=if cooModCon.y == integer(Buildings.Applications.DataCenters.Types.CoolingModes.FreeCooling) + y=if cooModCon.y == Integer(Buildings.Applications.DataCenters.Types.CoolingModes.FreeCooling) then 1 else 0), parMecCooSig( - y=if cooModCon.y == integer(Buildings.Applications.DataCenters.Types.CoolingModes.PartialMechanical) + y=if cooModCon.y == Integer(Buildings.Applications.DataCenters.Types.CoolingModes.PartialMechanical) then 1 else 0), fulMecCooSig( - y=if cooModCon.y == integer(Buildings.Applications.DataCenters.Types.CoolingModes.FullMechanical) + y=if cooModCon.y == Integer(Buildings.Applications.DataCenters.Types.CoolingModes.FullMechanical) then 1 else 0), PHVAC(y=cooTow[1].PFan + cooTow[2].PFan + pumCW[1].P + pumCW[2].P + sum( chiWSE.powChi + chiWSE.powPum) + ahu.PFan + ahu.PHea), diff --git a/Buildings/Controls/OBC/ASHRAE/G36_PR1/AHUs/MultiZone/SetPoints/VAVSupplyFan.mo b/Buildings/Controls/OBC/ASHRAE/G36_PR1/AHUs/MultiZone/SetPoints/VAVSupplyFan.mo index 38f4d21b304..3cbda72de79 100644 --- a/Buildings/Controls/OBC/ASHRAE/G36_PR1/AHUs/MultiZone/SetPoints/VAVSupplyFan.mo +++ b/Buildings/Controls/OBC/ASHRAE/G36_PR1/AHUs/MultiZone/SetPoints/VAVSupplyFan.mo @@ -413,7 +413,6 @@ Where the zone groups served by the system are small, provide multiple sets of gains that are used in the control loop as a function of a load indicator (such as supply fan airflow rate, the area of the zone groups that are occupied, etc.). -

", revisions="