Notifications
You must be signed in to change notification settings - Fork 38
/
Copy pathgrblError.py
64 lines (62 loc) · 4.75 KB
/
grblError.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
# -*- coding: UTF-8 -*-
'''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
' '
' Copyright 2018-2024 Gauthier Brière (gauthier.briere "at" gmail.com) '
' '
' This file is part of cn5X++ '
' '
' cn5X++ is free software: you can redistribute it and/or modify it '
' under the terms of the GNU General Public License as published by '
' the Free Software Foundation, either version 3 of the License, or '
' (at your option) any later version. '
' '
' cn5X++ is distributed in the hope that it will be useful, but '
' WITHOUT ANY WARRANTY; without even the implied warranty of '
' MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the '
' GNU General Public License for more details. '
' '
' You should have received a copy of the GNU General Public License '
' along with this program. If not, see <http://www.gnu.org/licenses/>. '
' '
'''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
grblError = [
[0, "No error."],
[1, "Expected command letter","G-code words consist of a letter and a value. Letter was not found."],
[2, "Bad number format","Missing the expected G-code word value or numeric value format is not valid."],
[3, "Invalid statement","Grbl '$' system command was not recognized or supported."],
[4, "Value < 0","Negative value received for an expected positive value."],
[5, "Setting disabled","Homing cycle failure. Homing is not enabled via settings."],
[6, "Value < 3 usec","Minimum step pulse time must be greater than 3usec."],
[7, "EEPROM read fail. Using defaults","An EEPROM read failed. Auto-restoring affected EEPROM to default values."],
[8, "Not idle","Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job."],
[9, "G-code lock","G-code commands are locked out during alarm or jog state."],
[10, "Homing not enabled","Soft limits cannot be enabled without homing also enabled."],
[11, "Line overflow","Max characters per line exceeded. Received command line was not executed."],
[12, "Step rate > 30kHz","Grbl '$' setting value cause the step rate to exceed the maximum supported."],
[13, "Check Door","Safety door detected as opened and door state initiated."],
[14, "Line length exceeded","Build info or startup line exceeded EEPROM line length limit. Line not stored."],
[15, "Travel exceeded","Jog target exceeds machine travel. Jog command has been ignored."],
[16, "Invalid jog command","Jog command has no ' = ' or contains prohibited g-code."],
[17, "Setting disabled","Laser mode requires PWM output."],
[18, "Unknown error."],
[19, "Unknown error."],
[20, "Unsupported command","Unsupported or invalid g-code command found in block."],
[21, "Modal group violation","More than one g-code command from same modal group found in block."],
[22, "Undefined feed rate","Feed rate has not yet been set or is undefined."],
[23, "Invalid gcode ID:23","G-code command in block requires an integer value."],
[24, "Invalid gcode ID:24","More than one g-code command that requires axis words found in block."],
[25, "Invalid gcode ID:25","Repeated g-code word found in block."],
[26, "Invalid gcode ID:26","No axis words found in block for g-code command or current modal state which requires them."],
[27, "Invalid gcode ID:27","Line number value is invalid."],
[28, "Invalid gcode ID:28","G-code command is missing a required value word."],
[29, "Invalid gcode ID:29","G59.x work coordinate systems are not supported."],
[30, "Invalid gcode ID:30","G53 only allowed with G0 and G1 motion modes."],
[31, "Invalid gcode ID:31","Axis words found in block when no command or current modal state uses them."],
[32, "Invalid gcode ID:32","G2 and G3 arcs require at least one in-plane axis word."],
[33, "Invalid gcode ID:33","Motion command target is invalid."],
[34, "Invalid gcode ID:34","Arc radius value is invalid."],
[35, "Invalid gcode ID:35","G2 and G3 arcs require at least one in-plane offset word."],
[36, "Invalid gcode ID:36","Unused value words found in block."],
[37, "Invalid gcode ID:37","G43.1 dynamic tool length offset is not assigned to configured tool length axis."],
[38, "Invalid gcode ID:38","Tool number greater than max supported value."]
]