Skip to content

This issue was moved to a discussion.

You can continue the conversation there. Go to discussion →

Ladung kann nach pause nicht jedes mal gestartet werden #21293

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Closed
2 tasks done
Jrlohni opened this issue May 18, 2025 · 6 comments · May be fixed by #21513
Closed
2 tasks done

Ladung kann nach pause nicht jedes mal gestartet werden #21293

Jrlohni opened this issue May 18, 2025 · 6 comments · May be fixed by #21513

Comments

@Jrlohni
Copy link

Jrlohni commented May 18, 2025

Describe the bug

Moin zusammen,

wenn eine längere Ladepause eingelegt wird, beginnt der Dacia an mehreren Wallboxen nicht mehr zu laden.
Das Verhalten ist vor allem aufgefallen, da der Ladeplan nicht mehr absolviert wird und das Auto morgens nicht voll ist.
Soweit ich das noch weiß, war immer ein zweites Auto an einer anderen Wallbox angeschlossen, hat aber nie geladen. Außerdem ist ein Lastmanagement konfiguriert.

  1. Ladung steht auf PV, Ladeplan ist eingestellt auf 4 Uhr morgens, Ladung ist um 18 Uhr abends pausiert worden. Ladung beginnt nicht mit Ladeplan.
  2. Ladung steht auf PV, Ladung ist ca. 4 Stunden vor dem Test pausiert worden, Ladung startet nicht beim Umstellen auf "Schnell".
  3. Ladung steht auf PV, Ladung ist ca. 4 Stunden vor dem Test pausiert worden, Ladung startet bei dem Umstellen auf "Min+PV" und lädt auch auf "Schnell" weiter. (Konnte allerdings nur einmal erreicht werden.)
    Anbei ist das Log von einem der Test. Dort wird der Wake-Up-Mode vermutlich nicht lange genug aufrechterhalten, oder? Das war zumindest der einzige Unterschied, welchen ich feststellen konnte bei den Tests.

Grüße Johannes

Steps to reproduce

  1. Zwei Autos an je eine Wallbox anschließen (eventuell reicht auch eins)
  2. Laden mit dem Dacia Spring kurz starten, dann pausieren.
    3.1 Laden über Ladeplan in 8 Stunden wieder starten lassen.
    3.2 Laden nach einigen Stunden auf "Schnell" stellen

Configuration details

charger
---
db:8 {Type:template Title: Icon: Product:Juice Charger Me} map[host:192.168.178.109 port:502 template:bender]
db:13 {Type:template Title: Icon: Product:go-e Charger Gemini, HOME+, HOMEfix (V3)} map[host:192.168.178.31 template:go-e-v3]
db:14 {Type:template Title: Icon: Product:go-e Charger Gemini, HOME+, HOMEfix (V3)} map[host:192.168.178.31 template:go-e-v3]

vehicle
---
db:3 {Type:template Title: Icon: Product:} map[cache:15m capacity:28.3 icon:car maxCurrent:16 minCurrent:6 mode:pv password:***** phases:1 priority:3 template:dacia title:Gret user:*****]
db:6 {Type:template Title: Icon: Product:} map[cache:6e+11 capacity:62 icon:shuttle maxCurrent:16 minCurrent:6 mode:minpv password:***** priority:1 template:enyaq timeout:10s title:Muddi user:*****]
db:7 {Type:template Title: Icon: Product:} map[accessToken:******* cache:15m capacity:79 clientId:******* commandProxy:https://api.myteslamate.com icon:van maxCurrent:16 minCurrent:6 mode:minpv priority:2 refreshToken:******************* template:tesla title:Guido]

loadpoint
---
db:9 {Type: Title: Icon: Product:} map[charger:db:8 circuit:main defaultMode:pv limitSoc:0 maxCurrent:16 meter: mode:pv phasesConfigured:3 soc:map[estimate:true poll:map[interval:9e+11 mode:connected]] thresholds:map[disable:map[delay:3e+11 threshold:0] enable:map[delay:9e+10 threshold:-1400]] title:Hof (Schwarz) vehicle:]
db:15 {Type: Title: Icon: Product:} map[charger:db:14 circuit:main defaultMode:pv limitSoc:0 maxCurrent:16 meter: minCurrent:6 mode:pv phasesConfigured:1 priority:0 soc:map[estimate:true poll:map[interval:9e+11 mode:connected]] thresholds:map[disable:map[delay:3e+11 threshold:0] enable:map[delay:9e+10 threshold:-1400]] title:Garage (Gelb) vehicle:]

Log details

[site  ] DEBUG 2025/05/15 05:18:13 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:13 grid power: 4465W
[site  ] DEBUG 2025/05/15 05:18:13 site power: 4465W
[lp-2  ] DEBUG 2025/05/15 05:18:13 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:13 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:13 next soc poll remaining time: 11m56s
[lp-2  ] DEBUG 2025/05/15 05:18:13 plan: charge 54m21s between 2025-05-15 05:18:13 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:18:13 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:18:13 charger disable
[lp-2  ] DEBUG 2025/05/15 05:18:13 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:13 solar forecast: accumulated 619.386kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:14 ----
[lp-1  ] DEBUG 2025/05/15 05:18:14 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:15 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:15 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:15 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:15 current: 16A
[site  ] DEBUG 2025/05/15 05:18:15 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:15 grid power: 4463W
[site  ] DEBUG 2025/05/15 05:18:15 site power: 4463W
[lp-1  ] DEBUG 2025/05/15 05:18:15 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:15 next soc poll remaining time: 2m19s
[lp-1  ] DEBUG 2025/05/15 05:18:15 plan: charge 25m18s between 2025-05-15 05:18:15 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:18:15 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:18:15 charger disable
[lp-1  ] DEBUG 2025/05/15 05:18:15 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:15 solar forecast: accumulated 619.386kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:16 ----
[lp-1  ] DEBUG 2025/05/15 05:18:16 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:17 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:17 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:17 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:17 current: 0A
[site  ] DEBUG 2025/05/15 05:18:17 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:17 grid power: 4462W
[site  ] DEBUG 2025/05/15 05:18:17 site power: 4462W
[lp-2  ] DEBUG 2025/05/15 05:18:17 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:17 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:17 next soc poll remaining time: 11m51s
[lp-2  ] DEBUG 2025/05/15 05:18:17 plan: charge 54m21s between 2025-05-15 05:18:17 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:18:17 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:18:17 charger enable
[lp-2  ] DEBUG 2025/05/15 05:18:17 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:17 solar forecast: accumulated 619.386kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:18 ----
[lp-1  ] DEBUG 2025/05/15 05:18:18 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:19 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:19 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:19 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:19 current: 0A
[site  ] DEBUG 2025/05/15 05:18:19 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:19 grid power: 4457W
[site  ] DEBUG 2025/05/15 05:18:19 site power: 4457W
[lp-1  ] DEBUG 2025/05/15 05:18:19 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:19 next soc poll remaining time: 2m16s
[lp-1  ] DEBUG 2025/05/15 05:18:19 plan: charge 25m18s between 2025-05-15 05:18:19 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:18:19 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:18:19 charger enable
[lp-1  ] DEBUG 2025/05/15 05:18:19 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:19 solar forecast: accumulated 619.386kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:20 ----
[lp-1  ] DEBUG 2025/05/15 05:18:20 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:21 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:21 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:21 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:21 current: 16A
[site  ] DEBUG 2025/05/15 05:18:21 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:21 grid power: 4454W
[site  ] DEBUG 2025/05/15 05:18:21 site power: 4454W
[lp-2  ] DEBUG 2025/05/15 05:18:21 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:21 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:21 next soc poll remaining time: 11m48s
[lp-2  ] DEBUG 2025/05/15 05:18:21 plan: charge 54m21s between 2025-05-15 05:18:21 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:18:21 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:18:21 charger disable
[lp-2  ] DEBUG 2025/05/15 05:18:21 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:21 solar forecast: accumulated 619.386kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:22 ----
[lp-1  ] DEBUG 2025/05/15 05:18:22 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:23 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:23 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:23 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:23 current: 16A
[site  ] DEBUG 2025/05/15 05:18:23 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:23 grid power: 4451W
[site  ] DEBUG 2025/05/15 05:18:23 site power: 4451W
[lp-1  ] DEBUG 2025/05/15 05:18:23 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:23 next soc poll remaining time: 2m11s
[lp-1  ] DEBUG 2025/05/15 05:18:23 plan: charge 25m18s between 2025-05-15 05:18:23 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:18:23 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:18:23 charger disable
[lp-1  ] DEBUG 2025/05/15 05:18:23 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:23 solar forecast: accumulated 619.386kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:24 ----
[lp-1  ] DEBUG 2025/05/15 05:18:24 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:25 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:25 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:25 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:25 current: 0A
[site  ] DEBUG 2025/05/15 05:18:25 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:25 grid power: 4453W
[site  ] DEBUG 2025/05/15 05:18:25 site power: 4453W
[lp-2  ] DEBUG 2025/05/15 05:18:25 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:25 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:25 next soc poll remaining time: 11m43s
[lp-2  ] DEBUG 2025/05/15 05:18:25 plan: charge 54m21s between 2025-05-15 05:18:25 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:18:25 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:18:25 charger enable
[lp-2  ] DEBUG 2025/05/15 05:18:25 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:25 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:26 ----
[lp-1  ] DEBUG 2025/05/15 05:18:26 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:27 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:27 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:27 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:27 current: 0A
[site  ] DEBUG 2025/05/15 05:18:27 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:27 grid power: 4445W
[site  ] DEBUG 2025/05/15 05:18:27 site power: 4445W
[lp-1  ] DEBUG 2025/05/15 05:18:27 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:27 next soc poll remaining time: 2m8s
[lp-1  ] DEBUG 2025/05/15 05:18:27 plan: charge 25m18s between 2025-05-15 05:18:27 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:18:27 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:18:27 charger enable
[lp-1  ] DEBUG 2025/05/15 05:18:27 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:27 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:28 ----
[lp-1  ] DEBUG 2025/05/15 05:18:28 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:29 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:29 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:29 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:29 current: 16A
[site  ] DEBUG 2025/05/15 05:18:29 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:29 grid power: 4448W
[site  ] DEBUG 2025/05/15 05:18:29 site power: 4448W
[lp-2  ] DEBUG 2025/05/15 05:18:29 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:29 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:29 next soc poll remaining time: 11m39s
[lp-2  ] DEBUG 2025/05/15 05:18:29 plan: charge 54m21s between 2025-05-15 05:18:29 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:18:29 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:18:29 charger disable
[lp-2  ] DEBUG 2025/05/15 05:18:29 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:29 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:30 ----
[lp-1  ] DEBUG 2025/05/15 05:18:30 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:31 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:31 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:31 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:31 current: 16A
[site  ] DEBUG 2025/05/15 05:18:31 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:31 grid power: 4429W
[site  ] DEBUG 2025/05/15 05:18:31 site power: 4429W
[lp-1  ] DEBUG 2025/05/15 05:18:31 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:31 next soc poll remaining time: 2m3s
[lp-1  ] DEBUG 2025/05/15 05:18:31 plan: charge 25m18s between 2025-05-15 05:18:31 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:18:31 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:18:31 charger disable
[lp-1  ] DEBUG 2025/05/15 05:18:31 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:31 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:32 ----
[lp-1  ] DEBUG 2025/05/15 05:18:32 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:33 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:33 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:33 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:33 current: 0A
[site  ] DEBUG 2025/05/15 05:18:33 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:33 grid power: 4392W
[site  ] DEBUG 2025/05/15 05:18:33 site power: 4392W
[lp-2  ] DEBUG 2025/05/15 05:18:33 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:33 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:33 next soc poll remaining time: 11m35s
[lp-2  ] DEBUG 2025/05/15 05:18:33 plan: charge 54m21s between 2025-05-15 05:18:33 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:18:33 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:18:33 charger enable
[lp-2  ] DEBUG 2025/05/15 05:18:33 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:33 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:34 ----
[lp-1  ] DEBUG 2025/05/15 05:18:34 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:35 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:35 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:35 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:35 current: 0A
[site  ] DEBUG 2025/05/15 05:18:35 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:35 grid power: 4393W
[site  ] DEBUG 2025/05/15 05:18:35 site power: 4393W
[lp-1  ] DEBUG 2025/05/15 05:18:35 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:35 next soc poll remaining time: 2m0s
[lp-1  ] DEBUG 2025/05/15 05:18:35 plan: charge 25m18s between 2025-05-15 05:18:35 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:18:35 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:18:35 charger enable
[lp-1  ] DEBUG 2025/05/15 05:18:35 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:35 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:36 ----
[lp-1  ] DEBUG 2025/05/15 05:18:36 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:37 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:37 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:37 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:37 current: 16A
[site  ] DEBUG 2025/05/15 05:18:37 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:37 grid power: 4381W
[site  ] DEBUG 2025/05/15 05:18:37 site power: 4381W
[lp-2  ] DEBUG 2025/05/15 05:18:37 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:37 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:37 next soc poll remaining time: 11m32s
[lp-2  ] DEBUG 2025/05/15 05:18:37 plan: charge 54m21s between 2025-05-15 05:18:37 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:18:37 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:18:37 charger disable
[lp-2  ] DEBUG 2025/05/15 05:18:37 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:37 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:38 ----
[lp-1  ] DEBUG 2025/05/15 05:18:38 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:39 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:39 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:39 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:39 current: 16A
[site  ] DEBUG 2025/05/15 05:18:39 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:39 grid power: 4502W
[site  ] DEBUG 2025/05/15 05:18:39 site power: 4502W
[lp-1  ] DEBUG 2025/05/15 05:18:39 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:39 next soc poll remaining time: 1m56s
[lp-1  ] DEBUG 2025/05/15 05:18:39 plan: charge 25m18s between 2025-05-15 05:18:39 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:18:39 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:18:39 charger disable
[lp-1  ] DEBUG 2025/05/15 05:18:39 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:39 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:40 ----
[lp-1  ] DEBUG 2025/05/15 05:18:40 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:41 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:41 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:41 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:41 current: 0A
[site  ] DEBUG 2025/05/15 05:18:41 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:41 grid power: 4430W
[site  ] DEBUG 2025/05/15 05:18:41 site power: 4430W
[lp-2  ] DEBUG 2025/05/15 05:18:41 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:41 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:41 next soc poll remaining time: 11m27s
[lp-2  ] DEBUG 2025/05/15 05:18:41 plan: charge 54m21s between 2025-05-15 05:18:41 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:18:41 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:18:41 charger enable
[lp-2  ] DEBUG 2025/05/15 05:18:41 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:41 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:42 ----
[lp-1  ] DEBUG 2025/05/15 05:18:42 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:43 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:43 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:43 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:43 current: 0A
[site  ] DEBUG 2025/05/15 05:18:43 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:43 grid power: 4397W
[site  ] DEBUG 2025/05/15 05:18:43 site power: 4397W
[lp-1  ] DEBUG 2025/05/15 05:18:43 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:43 next soc poll remaining time: 1m51s
[lp-1  ] DEBUG 2025/05/15 05:18:43 plan: charge 25m18s between 2025-05-15 05:18:43 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:18:43 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:18:43 charger enable
[lp-1  ] DEBUG 2025/05/15 05:18:43 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:43 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:44 ----
[lp-1  ] DEBUG 2025/05/15 05:18:44 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:45 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:45 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:45 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:45 current: 16A
[site  ] DEBUG 2025/05/15 05:18:45 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:45 grid power: 4375W
[site  ] DEBUG 2025/05/15 05:18:45 site power: 4375W
[lp-2  ] DEBUG 2025/05/15 05:18:45 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:45 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:45 next soc poll remaining time: 11m23s
[lp-2  ] DEBUG 2025/05/15 05:18:45 plan: charge 54m21s between 2025-05-15 05:18:45 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:18:45 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:18:45 charger disable
[lp-2  ] DEBUG 2025/05/15 05:18:45 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:45 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:46 ----
[lp-1  ] DEBUG 2025/05/15 05:18:46 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:47 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:47 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:47 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:47 current: 16A
[site  ] DEBUG 2025/05/15 05:18:47 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:47 grid power: 4366W
[site  ] DEBUG 2025/05/15 05:18:47 site power: 4366W
[lp-1  ] DEBUG 2025/05/15 05:18:47 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:47 next soc poll remaining time: 1m48s
[lp-1  ] DEBUG 2025/05/15 05:18:47 plan: charge 25m18s between 2025-05-15 05:18:47 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:18:47 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:18:47 charger disable
[lp-1  ] DEBUG 2025/05/15 05:18:47 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:47 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:48 ----
[lp-1  ] DEBUG 2025/05/15 05:18:48 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:49 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:49 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:49 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:49 current: 0A
[site  ] DEBUG 2025/05/15 05:18:49 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:49 grid power: 4336W
[site  ] DEBUG 2025/05/15 05:18:49 site power: 4336W
[lp-2  ] DEBUG 2025/05/15 05:18:49 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:49 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:49 next soc poll remaining time: 11m20s
[lp-2  ] DEBUG 2025/05/15 05:18:49 plan: charge 54m21s between 2025-05-15 05:18:49 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:18:49 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:18:49 charger enable
[lp-2  ] DEBUG 2025/05/15 05:18:49 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:49 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:50 ----
[lp-1  ] DEBUG 2025/05/15 05:18:50 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:51 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:51 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:51 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:51 current: 0A
[site  ] DEBUG 2025/05/15 05:18:51 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:51 grid power: 4314W
[site  ] DEBUG 2025/05/15 05:18:51 site power: 4314W
[lp-1  ] DEBUG 2025/05/15 05:18:51 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:51 next soc poll remaining time: 1m44s
[lp-1  ] DEBUG 2025/05/15 05:18:51 plan: charge 25m18s between 2025-05-15 05:18:51 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:18:51 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:18:51 charger enable
[lp-1  ] DEBUG 2025/05/15 05:18:51 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:51 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:52 ----
[lp-1  ] DEBUG 2025/05/15 05:18:52 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:53 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:53 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:53 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:53 current: 16A
[site  ] DEBUG 2025/05/15 05:18:53 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:53 grid power: 4310W
[site  ] DEBUG 2025/05/15 05:18:53 site power: 4310W
[lp-2  ] DEBUG 2025/05/15 05:18:53 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:53 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:53 next soc poll remaining time: 11m15s
[lp-2  ] DEBUG 2025/05/15 05:18:53 plan: charge 54m21s between 2025-05-15 05:18:53 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:18:53 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:18:53 charger disable
[lp-2  ] DEBUG 2025/05/15 05:18:53 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:53 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:54 ----
[lp-1  ] DEBUG 2025/05/15 05:18:54 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:55 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:55 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:55 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:55 current: 16A
[site  ] DEBUG 2025/05/15 05:18:55 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:55 grid power: 4303W
[site  ] DEBUG 2025/05/15 05:18:55 site power: 4303W
[lp-1  ] DEBUG 2025/05/15 05:18:55 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:55 next soc poll remaining time: 1m40s
[lp-1  ] DEBUG 2025/05/15 05:18:55 plan: charge 25m18s between 2025-05-15 05:18:55 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:18:55 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:18:55 charger disable
[lp-1  ] DEBUG 2025/05/15 05:18:55 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:18:55 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:56 ----
[lp-1  ] DEBUG 2025/05/15 05:18:56 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:57 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:57 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:57 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:57 current: 0A
[site  ] DEBUG 2025/05/15 05:18:57 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:57 grid power: 4308W
[site  ] DEBUG 2025/05/15 05:18:57 site power: 4308W
[lp-2  ] DEBUG 2025/05/15 05:18:57 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:18:57 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:18:57 next soc poll remaining time: 11m11s
[lp-2  ] DEBUG 2025/05/15 05:18:57 plan: charge 54m21s between 2025-05-15 05:18:57 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:18:57 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:18:57 charger enable
[lp-2  ] DEBUG 2025/05/15 05:18:57 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:57 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:18:58 ----
[lp-1  ] DEBUG 2025/05/15 05:18:58 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:59 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:18:59 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:18:59 power: 0W
[circuit-main] DEBUG 2025/05/15 05:18:59 current: 0A
[site  ] DEBUG 2025/05/15 05:18:59 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:18:59 grid power: 4295W
[site  ] DEBUG 2025/05/15 05:18:59 site power: 4295W
[lp-1  ] DEBUG 2025/05/15 05:18:59 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:18:59 next soc poll remaining time: 1m36s
[lp-1  ] DEBUG 2025/05/15 05:18:59 plan: charge 25m18s between 2025-05-15 05:18:59 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:18:59 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:18:59 charger enable
[lp-1  ] DEBUG 2025/05/15 05:18:59 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:18:59 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:00 ----
[lp-1  ] DEBUG 2025/05/15 05:19:00 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:01 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:01 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:01 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:01 current: 16A
[site  ] DEBUG 2025/05/15 05:19:01 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:01 grid power: 3184W
[site  ] DEBUG 2025/05/15 05:19:01 site power: 3184W
[lp-2  ] DEBUG 2025/05/15 05:19:01 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:01 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:01 next soc poll remaining time: 11m7s
[lp-2  ] DEBUG 2025/05/15 05:19:01 plan: charge 54m21s between 2025-05-15 05:19:01 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:19:01 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:01 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:01 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:01 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:02 ----
[lp-1  ] DEBUG 2025/05/15 05:19:02 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:03 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:03 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:03 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:03 current: 16A
[site  ] DEBUG 2025/05/15 05:19:03 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:03 grid power: 2627W
[site  ] DEBUG 2025/05/15 05:19:03 site power: 2627W
[lp-1  ] DEBUG 2025/05/15 05:19:03 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:03 next soc poll remaining time: 1m32s
[lp-1  ] DEBUG 2025/05/15 05:19:03 plan: charge 25m18s between 2025-05-15 05:19:03 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:03 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:03 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:03 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:03 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:04 ----
[lp-1  ] DEBUG 2025/05/15 05:19:04 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:05 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:05 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:05 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:05 current: 0A
[site  ] DEBUG 2025/05/15 05:19:05 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:05 grid power: 2380W
[site  ] DEBUG 2025/05/15 05:19:05 site power: 2380W
[lp-2  ] DEBUG 2025/05/15 05:19:05 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:05 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:05 next soc poll remaining time: 11m4s
[lp-2  ] DEBUG 2025/05/15 05:19:05 plan: charge 54m21s between 2025-05-15 05:19:05 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:19:05 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:05 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:05 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:05 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:06 ----
[lp-1  ] DEBUG 2025/05/15 05:19:06 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:07 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:07 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:07 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:07 current: 0A
[site  ] DEBUG 2025/05/15 05:19:07 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:07 grid power: 2248W
[site  ] DEBUG 2025/05/15 05:19:07 site power: 2248W
[lp-1  ] DEBUG 2025/05/15 05:19:07 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:07 next soc poll remaining time: 1m28s
[lp-1  ] DEBUG 2025/05/15 05:19:07 plan: charge 25m18s between 2025-05-15 05:19:07 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:07 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:07 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:07 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:07 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:08 ----
[lp-1  ] DEBUG 2025/05/15 05:19:08 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:09 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:09 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:09 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:09 current: 16A
[site  ] DEBUG 2025/05/15 05:19:09 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:09 grid power: 2186W
[site  ] DEBUG 2025/05/15 05:19:09 site power: 2186W
[lp-2  ] DEBUG 2025/05/15 05:19:09 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:09 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:09 next soc poll remaining time: 10m59s
[lp-2  ] DEBUG 2025/05/15 05:19:09 plan: charge 54m21s between 2025-05-15 05:19:09 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[circuit-main] DEBUG 2025/05/15 05:19:09 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:09 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:09 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:09 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:10 ----
[lp-1  ] DEBUG 2025/05/15 05:19:10 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:11 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:11 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:11 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:11 current: 16A
[site  ] DEBUG 2025/05/15 05:19:11 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:11 grid power: 2158W
[site  ] DEBUG 2025/05/15 05:19:11 site power: 2158W
[lp-1  ] DEBUG 2025/05/15 05:19:11 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:11 next soc poll remaining time: 1m24s
[lp-1  ] DEBUG 2025/05/15 05:19:11 plan: charge 25m18s between 2025-05-15 05:19:11 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:11 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:11 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:11 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:11 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:12 ----
[lp-1  ] DEBUG 2025/05/15 05:19:12 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:13 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:13 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:13 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:13 current: 0A
[site  ] DEBUG 2025/05/15 05:19:13 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:13 grid power: 2137W
[site  ] DEBUG 2025/05/15 05:19:13 site power: 2137W
[lp-2  ] DEBUG 2025/05/15 05:19:13 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:13 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:13 next soc poll remaining time: 10m56s
[lp-2  ] DEBUG 2025/05/15 05:19:13 plan: charge 54m21s between 2025-05-15 05:19:13 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.290)
[lp-2  ] DEBUG 2025/05/15 05:19:13 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:13 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:13 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:13 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:14 ----
[lp-1  ] DEBUG 2025/05/15 05:19:14 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:15 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:15 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:15 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:15 current: 0A
[site  ] DEBUG 2025/05/15 05:19:15 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:15 grid power: 3023W
[site  ] DEBUG 2025/05/15 05:19:15 site power: 3023W
[lp-1  ] DEBUG 2025/05/15 05:19:15 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:15 next soc poll remaining time: 1m20s
[lp-1  ] DEBUG 2025/05/15 05:19:15 plan: charge 25m18s between 2025-05-15 05:19:15 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:15 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:15 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:15 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:15 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:16 ----
[lp-1  ] DEBUG 2025/05/15 05:19:16 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:17 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:17 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:17 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:17 current: 16A
[site  ] DEBUG 2025/05/15 05:19:17 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:17 grid power: 3596W
[site  ] DEBUG 2025/05/15 05:19:17 site power: 3596W
[lp-2  ] DEBUG 2025/05/15 05:19:17 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:17 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:17 next soc poll remaining time: 10m51s
[lp-2  ] DEBUG 2025/05/15 05:19:17 plan: charge 54m21s between 2025-05-15 05:19:17 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[circuit-main] DEBUG 2025/05/15 05:19:17 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:17 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:17 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:17 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:18 ----
[lp-1  ] DEBUG 2025/05/15 05:19:18 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:19 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:19 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:19 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:19 current: 16A
[site  ] DEBUG 2025/05/15 05:19:19 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:19 grid power: 3884W
[site  ] DEBUG 2025/05/15 05:19:19 site power: 3884W
[lp-1  ] DEBUG 2025/05/15 05:19:19 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:19 next soc poll remaining time: 1m16s
[lp-1  ] DEBUG 2025/05/15 05:19:19 plan: charge 25m18s between 2025-05-15 05:19:19 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:19 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:19 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:19 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:19 solar forecast: accumulated 619.387kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:20 ----
[lp-1  ] DEBUG 2025/05/15 05:19:20 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:21 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:21 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:21 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:21 current: 0A
[site  ] DEBUG 2025/05/15 05:19:21 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:21 grid power: 4026W
[site  ] DEBUG 2025/05/15 05:19:21 site power: 4026W
[lp-2  ] DEBUG 2025/05/15 05:19:21 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:21 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:21 next soc poll remaining time: 10m47s
[lp-2  ] DEBUG 2025/05/15 05:19:21 plan: charge 54m21s between 2025-05-15 05:19:21 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[lp-2  ] DEBUG 2025/05/15 05:19:21 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:21 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:21 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:21 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:22 ----
[lp-1  ] DEBUG 2025/05/15 05:19:22 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:23 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:23 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:23 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:23 current: 0A
[site  ] DEBUG 2025/05/15 05:19:23 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:23 grid power: 4100W
[site  ] DEBUG 2025/05/15 05:19:23 site power: 4100W
[lp-1  ] DEBUG 2025/05/15 05:19:23 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:23 next soc poll remaining time: 1m12s
[lp-1  ] DEBUG 2025/05/15 05:19:23 plan: charge 25m18s between 2025-05-15 05:19:23 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:23 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:23 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:23 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:23 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:24 ----
[lp-1  ] DEBUG 2025/05/15 05:19:24 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:25 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:25 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:25 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:25 current: 16A
[site  ] DEBUG 2025/05/15 05:19:25 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:25 grid power: 4145W
[site  ] DEBUG 2025/05/15 05:19:25 site power: 4145W
[lp-2  ] DEBUG 2025/05/15 05:19:25 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:25 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:25 next soc poll remaining time: 10m43s
[lp-2  ] DEBUG 2025/05/15 05:19:25 plan: charge 54m21s between 2025-05-15 05:19:25 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[circuit-main] DEBUG 2025/05/15 05:19:25 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:25 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:25 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:25 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:26 ----
[lp-1  ] DEBUG 2025/05/15 05:19:26 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:27 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:27 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:27 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:27 current: 16A
[site  ] DEBUG 2025/05/15 05:19:27 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:27 grid power: 4155W
[site  ] DEBUG 2025/05/15 05:19:27 site power: 4155W
[lp-1  ] DEBUG 2025/05/15 05:19:27 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:27 next soc poll remaining time: 1m8s
[lp-1  ] DEBUG 2025/05/15 05:19:27 plan: charge 25m18s between 2025-05-15 05:19:27 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:27 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:27 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:27 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:27 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:28 ----
[lp-1  ] DEBUG 2025/05/15 05:19:28 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:29 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:29 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:29 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:29 current: 0A
[site  ] DEBUG 2025/05/15 05:19:29 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:29 grid power: 4164W
[site  ] DEBUG 2025/05/15 05:19:29 site power: 4164W
[lp-2  ] DEBUG 2025/05/15 05:19:29 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:29 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:29 next soc poll remaining time: 10m40s
[lp-2  ] DEBUG 2025/05/15 05:19:29 plan: charge 54m21s between 2025-05-15 05:19:29 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[lp-2  ] DEBUG 2025/05/15 05:19:29 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:29 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:29 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:29 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:30 ----
[lp-1  ] DEBUG 2025/05/15 05:19:30 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:31 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:31 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:31 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:31 current: 0A
[site  ] DEBUG 2025/05/15 05:19:31 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:31 grid power: 4169W
[site  ] DEBUG 2025/05/15 05:19:31 site power: 4169W
[lp-1  ] DEBUG 2025/05/15 05:19:31 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:31 next soc poll remaining time: 1m4s
[lp-1  ] DEBUG 2025/05/15 05:19:31 plan: charge 25m18s between 2025-05-15 05:19:31 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:31 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:31 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:31 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:31 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:32 ----
[lp-1  ] DEBUG 2025/05/15 05:19:32 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:33 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:33 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:33 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:33 current: 16A
[site  ] DEBUG 2025/05/15 05:19:33 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:33 grid power: 4166W
[site  ] DEBUG 2025/05/15 05:19:33 site power: 4166W
[lp-2  ] DEBUG 2025/05/15 05:19:33 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:33 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:33 next soc poll remaining time: 10m36s
[lp-2  ] DEBUG 2025/05/15 05:19:33 plan: charge 54m21s between 2025-05-15 05:19:33 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[circuit-main] DEBUG 2025/05/15 05:19:33 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:33 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:33 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:33 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:34 ----
[lp-1  ] DEBUG 2025/05/15 05:19:34 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:35 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:35 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:35 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:35 current: 16A
[site  ] DEBUG 2025/05/15 05:19:35 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:35 grid power: 4182W
[site  ] DEBUG 2025/05/15 05:19:35 site power: 4182W
[lp-1  ] DEBUG 2025/05/15 05:19:35 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:35 next soc poll remaining time: 1m0s
[lp-1  ] DEBUG 2025/05/15 05:19:35 plan: charge 25m18s between 2025-05-15 05:19:35 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:35 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:35 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:35 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:35 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:36 ----
[lp-1  ] DEBUG 2025/05/15 05:19:36 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:37 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:37 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:37 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:37 current: 0A
[site  ] DEBUG 2025/05/15 05:19:37 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:37 grid power: 4204W
[site  ] DEBUG 2025/05/15 05:19:37 site power: 4204W
[lp-2  ] DEBUG 2025/05/15 05:19:37 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:37 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:37 next soc poll remaining time: 10m31s
[lp-2  ] DEBUG 2025/05/15 05:19:37 plan: charge 54m21s between 2025-05-15 05:19:37 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[lp-2  ] DEBUG 2025/05/15 05:19:37 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:37 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:37 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:37 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:38 ----
[lp-1  ] DEBUG 2025/05/15 05:19:38 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:39 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:39 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:39 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:39 current: 0A
[site  ] DEBUG 2025/05/15 05:19:39 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:39 grid power: 4225W
[site  ] DEBUG 2025/05/15 05:19:39 site power: 4225W
[lp-1  ] DEBUG 2025/05/15 05:19:39 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:39 next soc poll remaining time: 55s
[lp-1  ] DEBUG 2025/05/15 05:19:39 plan: charge 25m18s between 2025-05-15 05:19:39 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:39 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:39 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:39 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:39 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:40 ----
[lp-1  ] DEBUG 2025/05/15 05:19:40 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:41 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:41 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:41 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:41 current: 16A
[site  ] DEBUG 2025/05/15 05:19:41 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:41 grid power: 4229W
[site  ] DEBUG 2025/05/15 05:19:41 site power: 4229W
[lp-2  ] DEBUG 2025/05/15 05:19:41 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:41 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:41 next soc poll remaining time: 10m28s
[lp-2  ] DEBUG 2025/05/15 05:19:41 plan: charge 54m21s between 2025-05-15 05:19:41 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[circuit-main] DEBUG 2025/05/15 05:19:41 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:41 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:41 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:41 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:42 ----
[lp-1  ] DEBUG 2025/05/15 05:19:42 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:43 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:43 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:43 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:43 current: 16A
[site  ] DEBUG 2025/05/15 05:19:43 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:43 grid power: 4202W
[site  ] DEBUG 2025/05/15 05:19:43 site power: 4202W
[lp-1  ] DEBUG 2025/05/15 05:19:43 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:43 next soc poll remaining time: 52s
[lp-1  ] DEBUG 2025/05/15 05:19:43 plan: charge 25m18s between 2025-05-15 05:19:43 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:43 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:43 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:43 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:43 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:44 ----
[lp-1  ] DEBUG 2025/05/15 05:19:44 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:45 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:45 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:45 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:45 current: 0A
[site  ] DEBUG 2025/05/15 05:19:45 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:45 grid power: 4186W
[site  ] DEBUG 2025/05/15 05:19:45 site power: 4186W
[lp-2  ] DEBUG 2025/05/15 05:19:45 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:45 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:45 next soc poll remaining time: 10m23s
[lp-2  ] DEBUG 2025/05/15 05:19:45 plan: charge 54m21s between 2025-05-15 05:19:45 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[lp-2  ] DEBUG 2025/05/15 05:19:45 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:45 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:45 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:45 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:46 ----
[lp-1  ] DEBUG 2025/05/15 05:19:46 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:47 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:47 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:47 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:47 current: 0A
[site  ] DEBUG 2025/05/15 05:19:47 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:47 grid power: 4201W
[site  ] DEBUG 2025/05/15 05:19:47 site power: 4201W
[lp-1  ] DEBUG 2025/05/15 05:19:47 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:47 next soc poll remaining time: 48s
[lp-1  ] DEBUG 2025/05/15 05:19:47 plan: charge 25m18s between 2025-05-15 05:19:47 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:47 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:47 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:47 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:47 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:48 ----
[lp-1  ] DEBUG 2025/05/15 05:19:48 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:49 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:49 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:49 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:49 current: 16A
[site  ] DEBUG 2025/05/15 05:19:49 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:49 grid power: 4182W
[site  ] DEBUG 2025/05/15 05:19:49 site power: 4182W
[lp-2  ] DEBUG 2025/05/15 05:19:49 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:49 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:49 next soc poll remaining time: 10m20s
[lp-2  ] DEBUG 2025/05/15 05:19:49 plan: charge 54m21s between 2025-05-15 05:19:49 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[circuit-main] DEBUG 2025/05/15 05:19:49 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:49 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:49 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:49 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:50 ----
[lp-1  ] DEBUG 2025/05/15 05:19:50 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:51 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:51 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:51 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:51 current: 16A
[site  ] DEBUG 2025/05/15 05:19:51 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:51 grid power: 4171W
[site  ] DEBUG 2025/05/15 05:19:51 site power: 4171W
[lp-1  ] DEBUG 2025/05/15 05:19:51 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:51 next soc poll remaining time: 44s
[lp-1  ] DEBUG 2025/05/15 05:19:51 plan: charge 25m18s between 2025-05-15 05:19:51 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:51 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:51 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:51 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:51 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:52 ----
[lp-1  ] DEBUG 2025/05/15 05:19:52 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:53 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:53 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:53 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:53 current: 0A
[site  ] DEBUG 2025/05/15 05:19:53 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:53 grid power: 4195W
[site  ] DEBUG 2025/05/15 05:19:53 site power: 4195W
[lp-2  ] DEBUG 2025/05/15 05:19:53 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:53 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:53 next soc poll remaining time: 10m15s
[lp-2  ] DEBUG 2025/05/15 05:19:53 plan: charge 54m21s between 2025-05-15 05:19:53 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[lp-2  ] DEBUG 2025/05/15 05:19:53 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:19:53 charger enable
[lp-2  ] DEBUG 2025/05/15 05:19:53 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:53 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:54 ----
[lp-1  ] DEBUG 2025/05/15 05:19:54 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:55 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:55 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:55 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:55 current: 0A
[site  ] DEBUG 2025/05/15 05:19:55 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:55 grid power: 4211W
[site  ] DEBUG 2025/05/15 05:19:55 site power: 4211W
[lp-1  ] DEBUG 2025/05/15 05:19:55 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:55 next soc poll remaining time: 40s
[lp-1  ] DEBUG 2025/05/15 05:19:55 plan: charge 25m18s between 2025-05-15 05:19:55 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/15 05:19:55 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/15 05:19:55 charger enable
[lp-1  ] DEBUG 2025/05/15 05:19:55 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:19:55 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:56 ----
[lp-1  ] DEBUG 2025/05/15 05:19:56 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:57 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:57 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:57 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:57 current: 16A
[site  ] DEBUG 2025/05/15 05:19:57 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:57 grid power: 4217W
[site  ] DEBUG 2025/05/15 05:19:57 site power: 4217W
[lp-2  ] DEBUG 2025/05/15 05:19:57 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:19:57 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:19:57 next soc poll remaining time: 10m11s
[lp-2  ] DEBUG 2025/05/15 05:19:57 plan: charge 54m21s between 2025-05-15 05:19:57 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[circuit-main] DEBUG 2025/05/15 05:19:57 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-2  ] DEBUG 2025/05/15 05:19:57 charger disable
[lp-2  ] DEBUG 2025/05/15 05:19:57 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:57 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:19:58 ----
[lp-1  ] DEBUG 2025/05/15 05:19:58 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:59 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:19:59 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:19:59 power: 0W
[circuit-main] DEBUG 2025/05/15 05:19:59 current: 16A
[site  ] DEBUG 2025/05/15 05:19:59 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:19:59 grid power: 4218W
[site  ] DEBUG 2025/05/15 05:19:59 site power: 4218W
[lp-1  ] DEBUG 2025/05/15 05:19:59 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:19:59 next soc poll remaining time: 36s
[lp-1  ] DEBUG 2025/05/15 05:19:59 plan: charge 25m18s between 2025-05-15 05:19:59 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/15 05:19:59 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/15 05:19:59 charger disable
[lp-1  ] DEBUG 2025/05/15 05:19:59 wake-up timer: stop
[site  ] DEBUG 2025/05/15 05:19:59 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:20:00 ----
[lp-1  ] DEBUG 2025/05/15 05:20:00 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:20:01 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:20:01 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:20:01 power: 0W
[circuit-main] DEBUG 2025/05/15 05:20:01 current: 0A
[site  ] DEBUG 2025/05/15 05:20:01 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:20:01 grid power: 4214W
[site  ] DEBUG 2025/05/15 05:20:01 site power: 4214W
[lp-2  ] DEBUG 2025/05/15 05:20:01 charge total import: 18685.901kWh
[lp-2  ] DEBUG 2025/05/15 05:20:01 charger status: B
[lp-2  ] DEBUG 2025/05/15 05:20:01 next soc poll remaining time: 10m7s
[lp-2  ] DEBUG 2025/05/15 05:20:01 plan: charge 54m21s between 2025-05-15 05:20:01 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)
[lp-2  ] DEBUG 2025/05/15 05:20:01 set charge current limit: 16A
[lp-2  ] DEBUG 2025/05/15 05:20:01 charger enable
[lp-2  ] DEBUG 2025/05/15 05:20:01 wake-up timer: start
[site  ] DEBUG 2025/05/15 05:20:01 solar forecast: accumulated 619.388kWh, produced 997.883kWh, scale 1.611
[site  ] DEBUG 2025/05/15 05:20:02 ----
[lp-1  ] DEBUG 2025/05/15 05:20:02 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:20:03 charge power: 0W
[lp-2  ] DEBUG 2025/05/15 05:20:03 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/15 05:20:03 power: 0W
[circuit-main] DEBUG 2025/05/15 05:20:03 current: 0A
[site  ] DEBUG 2025/05/15 05:20:03 pv 1 power: 0W
[site  ] DEBUG 2025/05/15 05:20:03 grid power: 4220W
[site  ] DEBUG 2025/05/15 05:20:03 site power: 4220W
[lp-1  ] DEBUG 2025/05/15 05:20:03 charger status: B
[lp-1  ] DEBUG 2025/05/15 05:20:03 next soc poll remaining time: 32s
[lp-1  ] DEBUG 2025/05/15 05:20:03 plan: charge 25m18s between 2025-05-15 05:20:03 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)

What type of operating system or environment does evcc run on?

Docker container

External automation

  • I have made sure that no external automation like HomeAssistant or Node-RED is active or accessing any of the mentioned devices when this issue occurs.

Nightly build

  • I have verified that the issue is reproducible with the latest nightly build

Version

203.5

@Jrlohni
Copy link
Author

Jrlohni commented May 18, 2025

Ich hätte noch eine größere Konfigurationsdatei, welche ich direkt im Issue nicht Posten konnte. Leider bekomme ich die Formatierung hier auch nicht vernünftig hin, damit Sie hier gut zu lesen ist (nicht als "Code", nicht sonst wie...) daher hier als Datei.

Konfig_EVCC.txt

@mfuchs1984
Copy link
Contributor

Du hast wie es aussieht ein interval von 2 Sekunden. So schnell reagiert keine Wallbox. Stell das mal auf 30 wie empfohlen.

@Jrlohni
Copy link
Author

Jrlohni commented May 18, 2025

Guter Hinweis! Das teste ich mal!
Jedoch hat es jetzt ein Jahr ohne Probleme auf 2 Sekunden und auch einer Sekunde funktioniert. Außerdem funktioniert es auch jetzt immer wieder so, nur nach einer längeren Ladepause nicht mehr.

@VolkerK62
Copy link
Contributor

VolkerK62 commented May 18, 2025

Für beide Loadpoints ist ein Ladeplan hinterlegt

[lp-1  ] DEBUG 2025/05/15 05:19:55 plan: charge 25m18s between 2025-05-15 05:19:55 +0200 CEST until 2025-05-15 06:00:00 +0200 CEST (power: 3680W, avg cost: 0.284)
[lp-2  ] DEBUG 2025/05/15 05:19:57 plan: charge 54m21s between 2025-05-15 05:19:57 +0200 CEST until 2025-05-15 06:30:00 +0200 CEST (power: 11040W, avg cost: 0.291)

Beide wollen laden, können aber nicht, wegen Lastmanagement.
[circuit-main] DEBUG 2025/05/15 05:19:57 validate current: 16A + (0A -> 16A) > 17A capped at 1A

Dadurch wird auch immer der wake-up beendet.

@Jrlohni
Copy link
Author

Jrlohni commented May 18, 2025

Oh sorry Leute, da hab ich ein Log zu spät gegriffen... Dort habe ich weitere Tests durchgeführt.

Hier ist eins, wo nur der LP-1 einen Plan hat. Gleiches Verhalten in EVCC natürlich.

[site  ] DEBUG 2025/05/07 22:42:40 ----
[lp-1  ] DEBUG 2025/05/07 22:42:40 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:41 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:41 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:41 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:41 current: 0A
[site  ] DEBUG 2025/05/07 22:42:41 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:41 grid power: 1564W
[site  ] DEBUG 2025/05/07 22:42:41 site power: 1564W
[lp-2  ] DEBUG 2025/05/07 22:42:41 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:42:41 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:42:41 pv charge current: 0A = 0A + -6.8A (1564W @ 1p)
[site  ] DEBUG 2025/05/07 22:42:41 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:42 ----
[lp-1  ] DEBUG 2025/05/07 22:42:42 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:43 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:43 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:43 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:43 current: 0A
[site  ] DEBUG 2025/05/07 22:42:43 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:43 grid power: 1583W
[site  ] DEBUG 2025/05/07 22:42:43 site power: 1583W
[lp-1  ] DEBUG 2025/05/07 22:42:43 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:42:43 next soc poll remaining time: 14m15s
[lp-1  ] DEBUG 2025/05/07 22:42:43 plan: charge 1h1m31s between 2025-05-07 22:42:43 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m14s, power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/07 22:42:43 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/07 22:42:43 charger enable
[lp-1  ] DEBUG 2025/05/07 22:42:43 wake-up timer: start
[lp-1  ] DEBUG 2025/05/07 22:42:43 pv timer elapse
[lp-1  ] DEBUG 2025/05/07 22:42:43 pv timer inactive
[site  ] DEBUG 2025/05/07 22:42:43 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:44 ----
[lp-1  ] DEBUG 2025/05/07 22:42:44 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:45 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:45 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:45 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:45 current: 16A
[site  ] DEBUG 2025/05/07 22:42:45 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:45 grid power: 1571W
[site  ] DEBUG 2025/05/07 22:42:45 site power: 1571W
[lp-2  ] DEBUG 2025/05/07 22:42:45 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:42:45 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:42:45 pv charge current: 0A = 0A + -6.83A (1571W @ 1p)
[site  ] DEBUG 2025/05/07 22:42:45 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:46 ----
[lp-1  ] DEBUG 2025/05/07 22:42:46 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:47 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:47 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:47 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:47 current: 16A
[site  ] DEBUG 2025/05/07 22:42:47 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:47 grid power: 1583W
[site  ] DEBUG 2025/05/07 22:42:47 site power: 1583W
[lp-1  ] DEBUG 2025/05/07 22:42:47 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:42:47 next soc poll remaining time: 14m11s
[lp-1  ] DEBUG 2025/05/07 22:42:47 plan: charge 1h1m31s between 2025-05-07 22:42:47 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m18s, power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/07 22:42:47 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/07 22:42:47 charger disable
[lp-1  ] DEBUG 2025/05/07 22:42:47 wake-up timer: stop
[site  ] DEBUG 2025/05/07 22:42:47 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:48 ----
[lp-1  ] DEBUG 2025/05/07 22:42:48 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:49 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:49 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:49 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:49 current: 0A
[site  ] DEBUG 2025/05/07 22:42:49 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:49 grid power: 1611W
[site  ] DEBUG 2025/05/07 22:42:49 site power: 1611W
[lp-2  ] DEBUG 2025/05/07 22:42:49 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:42:49 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:42:49 pv charge current: 0A = 0A + -7A (1611W @ 1p)
[site  ] DEBUG 2025/05/07 22:42:49 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:50 ----
[lp-1  ] DEBUG 2025/05/07 22:42:50 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:51 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:51 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:51 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:51 current: 0A
[site  ] DEBUG 2025/05/07 22:42:51 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:51 grid power: 1645W
[site  ] DEBUG 2025/05/07 22:42:51 site power: 1645W
[lp-1  ] DEBUG 2025/05/07 22:42:51 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:42:51 next soc poll remaining time: 14m7s
[lp-1  ] DEBUG 2025/05/07 22:42:51 plan: charge 1h1m31s between 2025-05-07 22:42:51 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m22s, power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/07 22:42:51 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/07 22:42:51 charger enable
[lp-1  ] DEBUG 2025/05/07 22:42:51 wake-up timer: start
[site  ] DEBUG 2025/05/07 22:42:51 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:52 ----
[lp-1  ] DEBUG 2025/05/07 22:42:52 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:53 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:53 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:53 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:53 current: 16A
[site  ] DEBUG 2025/05/07 22:42:53 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:53 grid power: 1668W
[site  ] DEBUG 2025/05/07 22:42:53 site power: 1668W
[lp-2  ] DEBUG 2025/05/07 22:42:53 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:42:53 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:42:53 pv charge current: 0A = 0A + -7.25A (1668W @ 1p)
[site  ] DEBUG 2025/05/07 22:42:53 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:54 ----
[lp-1  ] DEBUG 2025/05/07 22:42:54 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:55 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:55 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:55 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:55 current: 16A
[site  ] DEBUG 2025/05/07 22:42:55 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:55 grid power: 1678W
[site  ] DEBUG 2025/05/07 22:42:55 site power: 1678W
[lp-1  ] DEBUG 2025/05/07 22:42:55 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:42:55 next soc poll remaining time: 14m3s
[lp-1  ] DEBUG 2025/05/07 22:42:55 plan: charge 1h1m31s between 2025-05-07 22:42:55 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m26s, power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/07 22:42:55 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/07 22:42:55 charger disable
[lp-1  ] DEBUG 2025/05/07 22:42:55 wake-up timer: stop
[site  ] DEBUG 2025/05/07 22:42:55 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:56 ----
[lp-1  ] DEBUG 2025/05/07 22:42:56 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:57 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:57 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:57 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:57 current: 0A
[site  ] DEBUG 2025/05/07 22:42:57 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:57 grid power: 1682W
[site  ] DEBUG 2025/05/07 22:42:57 site power: 1682W
[lp-2  ] DEBUG 2025/05/07 22:42:57 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:42:57 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:42:57 pv charge current: 0A = 0A + -7.31A (1682W @ 1p)
[site  ] DEBUG 2025/05/07 22:42:57 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:42:58 ----
[lp-1  ] DEBUG 2025/05/07 22:42:58 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:59 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:42:59 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:42:59 power: 0W
[circuit-main] DEBUG 2025/05/07 22:42:59 current: 0A
[site  ] DEBUG 2025/05/07 22:42:59 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:42:59 grid power: 1656W
[site  ] DEBUG 2025/05/07 22:42:59 site power: 1656W
[lp-1  ] DEBUG 2025/05/07 22:42:59 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:42:59 next soc poll remaining time: 14m0s
[lp-1  ] DEBUG 2025/05/07 22:42:59 plan: charge 1h1m31s between 2025-05-07 22:42:59 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m30s, power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/07 22:42:59 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/07 22:42:59 charger enable
[lp-1  ] DEBUG 2025/05/07 22:42:59 wake-up timer: start
[site  ] DEBUG 2025/05/07 22:42:59 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:00 ----
[lp-1  ] DEBUG 2025/05/07 22:43:00 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:01 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:01 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:01 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:01 current: 16A
[site  ] DEBUG 2025/05/07 22:43:01 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:01 grid power: 1645W
[site  ] DEBUG 2025/05/07 22:43:01 site power: 1645W
[lp-2  ] DEBUG 2025/05/07 22:43:01 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:43:01 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:43:01 pv charge current: 0A = 0A + -7.15A (1645W @ 1p)
[site  ] DEBUG 2025/05/07 22:43:01 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:02 ----
[lp-1  ] DEBUG 2025/05/07 22:43:02 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:03 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:03 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:03 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:03 current: 16A
[site  ] DEBUG 2025/05/07 22:43:03 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:03 grid power: 1640W
[site  ] DEBUG 2025/05/07 22:43:03 site power: 1640W
[lp-1  ] DEBUG 2025/05/07 22:43:03 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:43:03 next soc poll remaining time: 13m55s
[lp-1  ] DEBUG 2025/05/07 22:43:03 plan: charge 1h1m31s between 2025-05-07 22:43:03 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m34s, power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/07 22:43:03 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/07 22:43:03 charger disable
[lp-1  ] DEBUG 2025/05/07 22:43:03 wake-up timer: stop
[site  ] DEBUG 2025/05/07 22:43:03 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:04 ----
[lp-1  ] DEBUG 2025/05/07 22:43:04 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:05 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:05 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:05 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:05 current: 0A
[site  ] DEBUG 2025/05/07 22:43:05 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:05 grid power: 1678W
[site  ] DEBUG 2025/05/07 22:43:05 site power: 1678W
[lp-2  ] DEBUG 2025/05/07 22:43:05 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:43:05 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:43:05 pv charge current: 0A = 0A + -7.3A (1678W @ 1p)
[site  ] DEBUG 2025/05/07 22:43:05 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:06 ----
[lp-1  ] DEBUG 2025/05/07 22:43:06 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:07 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:07 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:07 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:07 current: 0A
[site  ] DEBUG 2025/05/07 22:43:07 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:07 grid power: 1688W
[site  ] DEBUG 2025/05/07 22:43:07 site power: 1688W
[lp-1  ] DEBUG 2025/05/07 22:43:07 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:43:07 next soc poll remaining time: 13m51s
[lp-1  ] DEBUG 2025/05/07 22:43:07 plan: charge 1h1m31s between 2025-05-07 22:43:07 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m38s, power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/07 22:43:07 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/07 22:43:07 charger enable
[lp-1  ] DEBUG 2025/05/07 22:43:07 wake-up timer: start
[site  ] DEBUG 2025/05/07 22:43:07 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:08 ----
[lp-1  ] DEBUG 2025/05/07 22:43:08 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:09 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:09 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:09 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:09 current: 16A
[site  ] DEBUG 2025/05/07 22:43:09 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:09 grid power: 1685W
[site  ] DEBUG 2025/05/07 22:43:09 site power: 1685W
[lp-2  ] DEBUG 2025/05/07 22:43:09 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:43:09 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:43:09 pv charge current: 0A = 0A + -7.32A (1685W @ 1p)
[site  ] DEBUG 2025/05/07 22:43:09 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:10 ----
[lp-1  ] DEBUG 2025/05/07 22:43:10 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:11 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:11 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:11 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:11 current: 16A
[site  ] DEBUG 2025/05/07 22:43:11 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:11 grid power: 1681W
[site  ] DEBUG 2025/05/07 22:43:11 site power: 1681W
[lp-1  ] DEBUG 2025/05/07 22:43:11 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:43:11 next soc poll remaining time: 13m47s
[lp-1  ] DEBUG 2025/05/07 22:43:11 plan: charge 1h1m31s between 2025-05-07 22:43:11 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m42s, power: 3680W, avg cost: 0.284)
[circuit-main] DEBUG 2025/05/07 22:43:11 validate current: 16A + (0A -> 16A) > 17A capped at 1A
[lp-1  ] DEBUG 2025/05/07 22:43:11 charger disable
[lp-1  ] DEBUG 2025/05/07 22:43:11 wake-up timer: stop
[site  ] DEBUG 2025/05/07 22:43:11 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:12 ----
[lp-1  ] DEBUG 2025/05/07 22:43:12 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:13 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:13 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:13 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:13 current: 0A
[site  ] DEBUG 2025/05/07 22:43:13 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:13 grid power: 1681W
[site  ] DEBUG 2025/05/07 22:43:13 site power: 1681W
[lp-2  ] DEBUG 2025/05/07 22:43:13 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:43:13 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:43:13 pv charge current: 0A = 0A + -7.31A (1681W @ 1p)
[site  ] DEBUG 2025/05/07 22:43:13 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:14 ----
[lp-1  ] DEBUG 2025/05/07 22:43:14 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:15 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:15 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:15 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:15 current: 0A
[site  ] DEBUG 2025/05/07 22:43:15 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:15 grid power: 1676W
[site  ] DEBUG 2025/05/07 22:43:15 site power: 1676W
[lp-1  ] DEBUG 2025/05/07 22:43:15 charger status: B
[lp-1  ] DEBUG 2025/05/07 22:43:15 next soc poll remaining time: 13m43s
[lp-1  ] DEBUG 2025/05/07 22:43:15 plan: charge 1h1m31s between 2025-05-07 22:43:15 +0200 CEST until 2025-05-07 23:12:00 +0200 CEST (overruns by 32m46s, power: 3680W, avg cost: 0.284)
[lp-1  ] DEBUG 2025/05/07 22:43:15 set charge current limit: 16A
[lp-1  ] DEBUG 2025/05/07 22:43:15 charger enable
[lp-1  ] DEBUG 2025/05/07 22:43:15 wake-up timer: start
[site  ] DEBUG 2025/05/07 22:43:15 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877
[site  ] DEBUG 2025/05/07 22:43:16 ----
[lp-1  ] DEBUG 2025/05/07 22:43:16 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:17 charge power: 0W
[lp-2  ] DEBUG 2025/05/07 22:43:17 charge currents: [0 0 0]A
[circuit-main] DEBUG 2025/05/07 22:43:17 power: 0W
[circuit-main] DEBUG 2025/05/07 22:43:17 current: 16A
[site  ] DEBUG 2025/05/07 22:43:17 pv 1 power: 0W
[site  ] DEBUG 2025/05/07 22:43:17 grid power: 1674W
[site  ] DEBUG 2025/05/07 22:43:17 site power: 1674W
[lp-2  ] DEBUG 2025/05/07 22:43:17 charge total import: 18589.852kWh
[lp-2  ] DEBUG 2025/05/07 22:43:17 charger status: B
[lp-2  ] DEBUG 2025/05/07 22:43:17 pv charge current: 0A = 0A + -7.28A (1674W @ 1p)
[site  ] DEBUG 2025/05/07 22:43:17 solar forecast: accumulated 97.240kWh, produced 182.542kWh, scale 1.877

@mfuchs1984
Copy link
Contributor

Hier spuckt auch das Lastmanagement rein, ich denke weil dein charger kein meter hat. Stell erstmal auf 30 Sekunden um und mach dann nochmal ein Log.

@evcc-io evcc-io locked and limited conversation to collaborators May 19, 2025
@andig andig converted this issue into discussion #21303 May 19, 2025

This issue was moved to a discussion.

You can continue the conversation there. Go to discussion →

Labels
None yet
Projects
None yet
Development

Successfully merging a pull request may close this issue.

3 participants