de/index.json

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -1 +1 @@
1-
"broadcast.csv\nmemory.csv\nencon/\nkromschroeder/\nochsner/\ntem/\nvaillant/\nwolf/"
1+
"broadcast.csv\nencon/\nkromschroeder/\nmemory.csv\nochsner/\ntem/\nvaillant/\nwolf/"

de/vaillant/05.vd4.csv

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -2,8 +2,8 @@ type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,uni
22
*r,
33
*w,
44
*[id_sw],scan,,,,SW
5-
[id_sw>=200]r,,,ComErrorDelay,,,,b509,0d4300,value,,UIN,,Control interface,
6-
[id_sw>=200]w,,service,ComErrorDelay,,,,b509,0e4300,value,,UIN,,Control interface,
5+
[id_sw>=200]r,,,ComErrorDelay,,,,b509,0d4300,value,,UIN,,,Control interface
6+
[id_sw>=200]w,,service,ComErrorDelay,,,,b509,0e4300,value,,UIN,,,Control interface
77
r,,,SoftwareVersion,,,,b509,0d0000,value,,HEX:4,,,
88
w,,install,SoftwareVersion,,,,b509,0e0000,value,,HEX:4,,,
99
r,,,EnableMonitoring,,,,b509,0d0100,value,,HEX:5,,,

de/vaillant/06.pms.csv

Lines changed: 4 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -40,11 +40,11 @@ r,,,SolControlDiff,D_SolarControl,,,b509,0d2a00,value,,SIN,,,
4040
r,,,MonitorBufferPIDValue,MonitorBufferPIDValue,,,b509,0d2b00,value,,SIN,,,
4141
r,,,MonitorSolPIDValue,MonitorSolarPIDValue,,,b509,0d2c00,value,,SIN,,,
4242
r,,,FlowSensorFrequency,FlowSensorFrequency,,,b509,0d2d00,value,,UIN,,,
43-
r,,,CurrentFlow,Volumenstrom,,,b509,0d2e00,value,,UIN,,ml / min,Flow thru buffer circuit if loading the storage
43+
r,,,CurrentFlow,Volumenstrom,,,b509,0d2e00,value,,UIN,1000,l/min,Flow thru buffer circuit if loading the storage
4444
r,,,Variante,Variante: 1: VMS 302: VPM 20 S3: VPM 60 S,,,b509,0d3000,value,,UCH,,,
4545
r,,,CurrentSystemMode,Aktueller Systemmodus: 1 : Autonomer Modus3 : Regler Modus,,,b509,0d3300,value,,UCH,,,
46-
r,,,InternalHwcTempDesired,InternalDHWSetpoint: Temperature target for DHW loading if solar module is in stand alone appliccation without external control,,,b509,0d3500,value,,UCH,,,
47-
r,,,InternalHcTempDesired,InternalCHSetpoint: Temperature target for CW loading if solar module is in stand alone appliccation without external control,,,b509,0d3600,value,,UCH,,,
46+
r,,,InternalHwcTempDesired,InternalDHWSetpoint: Temperature target for DHW loading if solar module is in stand alone appliccation without external control,,,b509,0d3500,value,,UCH,,°C,Temperatur
47+
r,,,InternalHcTempDesired,InternalCHSetpoint: Temperature target for CW loading if solar module is in stand alone appliccation without external control,,,b509,0d3600,value,,UCH,,°C,Temperatur
4848
r,,,ASIDetected,ASIDetected,,,b509,0d3800,value,,UCH,0=off;1=on,,
4949
r,,,CountryZone,Land: Standort der für den Sonnenkalender herangezogen wird. Siehe Anleitung,,,b509,0d3900,value,,UCH,,,
5050
w,,install,CountryZone,Land: Standort der für den Sonnenkalender herangezogen wird. Siehe Anleitung,,,b509,0e3900,value,,UCH,,,
@@ -55,7 +55,7 @@ r,,,PowerOnCounter,Netz ein Zähler,,,b509,0d3f00,value,,UIN,,,
5555
r,,,RTCLowVoltageCounter,RTCLowVoltageCounter,,,b509,0d4000,value,,UIN,,,
5656
r,,,ForceStartSolPumpKick,Pumpenkick erzwingen: Startet die Kollektorpumpe für maximal 5 Minuten um die Kollektortemperatur zu überprüfen.0 = aus1 = ein,,,b509,0d4700,value,,UCH,0=off;1=on,,
5757
r,,,MonitorMatlabState,MonitorMatlabState: main states: 201: Waiting; 209: Loading; 41: Night Modus,,,b509,0d4800,value,,UCH,,,
58-
r,,,CurrentBufferTempDesired,Puffer Zieltemperatur: Zieltemperatur für den Pufferkreis am Ntc 3 Sensor,,,b509,0d4900,value,,SIN,,,
58+
r,,,CurrentBufferTempDesired,Puffer Zieltemperatur: Zieltemperatur für den Pufferkreis am Ntc 3 Sensor,,,b509,0d4900,value,,SIN,,°C,Temperatur
5959
r,,,RunTimeBufferPumpMinutes,Laufzeit Pufferpumpe: Laufzeit der Pufferpumpe (Minuten Anteil),,,b509,0d4b00,value,,UCH,,min,Minuten
6060
r,,,RunTimeBufferPumpHours,Laufzeit Pufferpumpe: Laufzeit der Pufferpumpe (Stunden Anteil),,,b509,0d4c00,value,,UIN,,h,Stunden
6161
r,,,MonitorOverheatState,MonitorOverheatState: 111: Waiting; 112 and 113: Temperature to high; 220 and 221: In Overheat protection,,,b509,0d4f00,value,,UCH,,,

de/vaillant/06.vms.csv

Lines changed: 3 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -25,11 +25,11 @@ w,,install,Time,Uhrzeit,,,b509,0e2300,value,,VTI,,,Uhrzeit
2525
r,,,Date,Datum,,,b509,0d2400,value,,HDA:3,,,Datum
2626
w,,install,Date,Datum,,,b509,0e2400,value,,HDA:3,,,Datum
2727
r,,,FlowSensorFrequency,FlowSensorFrequency,,,b509,0d2d00,value,,UIN,,,
28-
r,,,CurrentFlow,Volumenstrom,,,b509,0d2e00,value,,UIN,,ml / min,Flow thru buffer circuit if loading the storage
28+
r,,,CurrentFlow,Volumenstrom,,,b509,0d2e00,value,,UIN,1000,l/min,Flow thru buffer circuit if loading the storage
2929
r,,,Variante,Variante: 1: VMS 302: VPM 20 S3: VPM 60 S,,,b509,0d3000,value,,UCH,,,
3030
r,,,CurrentSystemMode,Aktueller Systemmodus: 1 : Autonomer Modus3 : Regler Modus,,,b509,0d3300,value,,UCH,,,
31-
r,,,InternalHwcTempDesired,InternalDHWSetpoint: Temperature target for DHW loading if solar module is in stand alone appliccation without external control,,,b509,0d3500,value,,UCH,,,
32-
r,,,InternalHcTempDesired,InternalCHSetpoint: Temperature target for CW loading if solar module is in stand alone appliccation without external control,,,b509,0d3600,value,,UCH,,,
31+
r,,,InternalHwcTempDesired,InternalDHWSetpoint: Temperature target for DHW loading if solar module is in stand alone appliccation without external control,,,b509,0d3500,value,,UCH,,°C,Temperatur
32+
r,,,InternalHcTempDesired,InternalCHSetpoint: Temperature target for CW loading if solar module is in stand alone appliccation without external control,,,b509,0d3600,value,,UCH,,°C,Temperatur
3333
r,,,ASIDetected,ASIDetected,,,b509,0d3800,value,,UCH,0=off;1=on,,
3434
r,,,CountryZone,Land: Standort der für den Sonnenkalender herangezogen wird. Siehe Anleitung,,,b509,0d3900,value,,UCH,,,
3535
w,,install,CountryZone,Land: Standort der für den Sonnenkalender herangezogen wird. Siehe Anleitung,,,b509,0e3900,value,,UCH,,,

de/vaillant/08.ehp.csv

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -88,8 +88,8 @@ type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,uni
8888
[id_sw>=403]r,,,CompRestartTimer,Kompressorrestsperrzeit: Verzögerung des nächsten Kompressorstartes. Wird nur aktualisiert wenn der Kompressor angefordert wird aber aufgrund der Laufzeitbedingungen nicht anlaufen darf.,,,b509,0dc501,value,,ULG,120,min,Minuten
8989
[id_sw>=414]r,,,HysteresisTimeDelay,hysteresis_time_delay: defined time delay until backup heater hysteresis becomes valid,,,b509,0de001,value,,UCH,,min,Minuten
9090
[id_sw>=414]w,,install,HysteresisTimeDelay,hysteresis_time_delay: defined time delay until backup heater hysteresis becomes valid,,,b509,0ee001,value,,UCH,,min,Minuten
91-
[id_sw>=414]r,,,ActualEnvironmentPowerFine,ActualEnvironmentPowerFine,,,b509,0de201,value,,UCH,,hW,environment power in higher resolution (100W)
92-
[id_sw>=414]u,,,ActualEnvironmentPowerFine,ActualEnvironmentPowerFine,,,b509,29e201,value,,IGN:2,,,,value,,UCH,,hW,environment power in higher resolution (100W)
91+
[id_sw>=414]r,,,ActualEnvironmentPowerFine,ActualEnvironmentPowerFine,,,b509,0de201,value,,UCH,10,kW,environment power in higher resolution (100W)
92+
[id_sw>=414]u,,,ActualEnvironmentPowerFine,ActualEnvironmentPowerFine,,,b509,29e201,value,,IGN:2,,,,value,,UCH,10,kW,environment power in higher resolution (100W)
9393
[id_sw>=414]r,,,BivalentMode,BivalentMode: reserved for special bivalent setting,,,b509,0de301,value,,UCH,,,
9494
[id_sw>=414]w,,install,BivalentMode,BivalentMode: reserved for special bivalent setting,,,b509,0ee301,value,,UCH,,,
9595
[id_sw>=415]r,,,SourceLimitAtMaxFlow,BrineLimitAtMaxFlow: lowest allowed brine temperature to achieve max. flow temperature,,,b509,0de401,value,,SCH,,,

de/vaillant/08.hmu.csv

Lines changed: 4 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -64,10 +64,10 @@ r,,,MaxFlowTemp,,,,b51a,05ff348f3532,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,°C
6464
r,,,MinFlowTemp,,,,b51a,05ff348f3533,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,°C,Minimum flow temperature (°C)
6565
r,,,HcModeActive,,,,b51a,05ff348f3534,value,,IGN:3,,,,ign,,IGN:3,,,,uch,,UCH,0=no;1=yes,,Central heating mode active (yes/no)
6666
r,,,HwcModeActive,,,,b51a,05ff348f3535,value,,IGN:3,,,,ign,,IGN:3,,,,uch,,UCH,0=no;1=yes,,Domestic hot water mode active (yes/no)
67-
r,,,HwcChargeHysteresis,,,,b51a,05ff348f3539,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,°K,Hysteresis Hwc charging (°K)
67+
r,,,HwcChargeHysteresis,,,,b51a,05ff348f3539,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,K,Hysteresis Hwc charging
6868
r,,,ImmersionHeaterMode,,,,b51a,05ff34c4331e,value,,IGN:3,,,,ign,,IGN:3,,,,uch,,UCH,0=off;1=on,,Immersion heater mode (on/off)
69-
r,,,CompressorHysteresisHc,,,,b51a,05ff34f83443,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,°K,Compressor hysteresis central heating (°K)
70-
r,,,CompressorHysteresisCooling,,,,b51a,05ff3486353f,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,,Compressor hysteresis cooling (°K)
69+
r,,,CompressorHysteresisHc,,,,b51a,05ff34f83443,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,K,Compressor hysteresis central heating
70+
r,,,CompressorHysteresisCooling,,,,b51a,05ff3486353f,value,,IGN:3,,,,ign,,IGN:3,,K,,d2c,,D2C,,,Compressor hysteresis cooling
7171
r,,,HwcMode,,,,b51a,05ff34523444,value,,IGN:3,,,,ign,,IGN:3,,,,uch,,UCH,0=eco;1=normal;2=balance,,Domestic hot water mod (eco/normal/balance)
7272
r,,,TargetTempHwc,,,,b51a,05ff34c63207,value,,IGN:3,,,,ign,,IGN:3,,,,d2c,,D2C,,°C,Target Hwc temperature (°C)
7373
r,,,YieldTotal,,,,b516,1801,value,,IGN:1,,,,value,,UIN,,kWh,
@@ -148,7 +148,7 @@ r,,service,TestMO3Output,MA3 output,,,b514,057f,value,,IGN:2,,,,value,,UCH,0=off
148148
r,,service,TestCondensorInletTemp,condensor inlet temperature,,,b514,0581,value,,IGN:2,,,,value,,SIN,10,°C,
149149
r,,service,TestFlowTempImmersionHeater,Vorlauftemperatur Heizstab,,,b514,0582,value,,IGN:2,,,,value,,SIN,10,°C,T1.130
150150
w,,service,EnableTestEEVTemp,read EEV temperature,,,b514,053b,ignore,,HEX:3,=000000,,,value,,HEX:3,,,
151-
r,,service,TestEEVTemp,EEV temperature,,,b514,053b000000,value,,IGN:2,,,,ign,,IGN:2,,,,sin,,SIN,10,,°C
151+
r,,service,TestEEVTemp,EEV temperature,,,b514,053b000000,value,,IGN:2,,,,ign,,IGN:2,,,,sin,,SIN,10,°C,
152152
w,,service,EnableiveMonitorMain,enable live monitor read status,,,b503,0003,
153153
u,,service,LiveMonitorMain,live monitor status,71,,b503,0003,status,,UCH,57=Controller_starting;244=Standby;245=Supply_on;246=Heating_Flow_ok;247=Heating_temperature_self_test;248=Heating_Start;250=Heating_Fan_on;252=EEV_switch;253=Compressor_starting;254=Heating_compressor_on;0=Compressor_off;2=Compressor_coast_down;3=Deicing_start;4=Deicing;5=Deicing_end;18=Cooling_Flow_on;20=Cooling_temperature_self_test;21=Cooling_starting;23=Cooling_Fan_on;19=Cooling_Flow_ok;25=Cooling_EEV;26=Cooling_compressor_starting;27=Cooling_compressor_on;29=Cooling_ending;41=Start_condition_not_met;87=Device_error;68=Flow_error_in_distribution_system,,,function,,UCH,1=Heating;2=Cooling,,
154154
r,,service,LiveMonitorDesiredSupplyTemp,desired supply temperature,,,b51a,0500321f,value,,IGN:3,,,,value,,D2C,,°C,Temperatur

de/vaillant/0a.pmw.hwc.csv

Lines changed: 21 additions & 21 deletions
Original file line numberDiff line numberDiff line change
@@ -3,20 +3,20 @@ type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,uni
33
*w,
44
*[id_sw],scan,,,,SW
55
[id_sw>=38]r,,,SingleStorageCharge,1x Speicherladung: Enable SingleTankCharge,,,b509,0d4400,value,,UCH,0=off;1=on,,
6-
[id_sw>=38]r,,,ZaehlerBetriebsStunden,ZaehlerBetriebsStunden: Working Hours,,,b509,0d4500,value,,UIN,,,
7-
[id_sw>=39]r,,,DurchflussTemp,Volumenstrom in Liter / Minute,,,b509,0d4600,value,,D2C,,°C,Temperatur
6+
[id_sw>=38]r,,,OperatingHours,ZaehlerBetriebsStunden: Working Hours,,,b509,0d4500,value,,UIN,,h,Stunden
7+
[id_sw>=39]r,,,FlowTemp,Volumenstrom in Liter / Minute,,,b509,0d4600,value,,D2C,,°C,Temperatur
88
[id_sw>=112]r,,,VPMWMode,"VPMW Typ: 1=VPM 20/25W, 2=VPM 30/35W",,,b509,0d4b00,value,,UCH,,,
99
[id_sw>=117]r,,,OverheatTimer,Overheat_timer,,,b509,0d5200,value,,UCH,,s,Sekunden
1010
[id_sw>=40]r,,,HexMonitoringCounter,HexMonitoringCounter: RO,,,b509,0d4700,value,,SIN,,,
11-
[id_sw>=40]r,,,HExThreshold,HExThreshold,,,b509,0d4800,value,,SIN,,in 1/100,RO
12-
[id_sw>=40]r,,,BigHExThreshold,BigHExThreshold,,,b509,0d4900,value,,SIN,,in 1/100,RW
13-
[id_sw>=40]r,,,HExIndex,HExIndex,,,b509,0d4a00,value,,SIN,,in 1/100,RO
14-
[id_sw>=113]r,,,ActualKrm,Actual_Krm,,,b509,0d4c00,value,,SIN,,in 1/1000,"Krm used for calculation (set in DynamicTnm), valid after 1. Tapping"
15-
[id_sw>=113]r,,,ActualTnm,Actual_Tnm,,,b509,0d4d00,value,,SIN,,in 1/1000,"Tnm used for calculation (set in DynamicTnm), valid after 1. Tapping"
16-
[id_sw>=114]r,,,KrmFaktorSmall,Krm_Faktor_Small,,,b509,0d4e00,value,,SIN,,in 1/1000,Krm Verstärkungsfaktor Small (1/1000)
17-
[id_sw>=114]r,,,KrmFaktorMiddl,Krm_Faktor_Middl,,,b509,0d4f00,value,,SIN,,in 1/1000,Krm Verstärkungsfaktor Middl (1/1000)
18-
[id_sw>=114]r,,,TnmFaktorSmall,Tnm_Faktor_Small,,,b509,0d5000,value,,SIN,,in 1/1000,Tnm Verstärkungsfaktor Small (1/1000)
19-
[id_sw>=114]r,,,TnmFaktorMiddl,Tnm_Faktor_Middl,,,b509,0d5100,value,,SIN,,in 1/1000,Tnm Verstärkungsfaktor Middl (1/1000)
11+
[id_sw>=40]r,,,HExThreshold,HExThreshold,,,b509,0d4800,value,,SIN,100,,RO
12+
[id_sw>=40]r,,,BigHExThreshold,BigHExThreshold,,,b509,0d4900,value,,SIN,100,,RW
13+
[id_sw>=40]r,,,HExIndex,HExIndex,,,b509,0d4a00,value,,SIN,100,,RO
14+
[id_sw>=113]r,,,ActualKrm,Actual_Krm,,,b509,0d4c00,value,,SIN,1000,,"Krm used for calculation (set in DynamicTnm), valid after 1. Tapping"
15+
[id_sw>=113]r,,,ActualTnm,Actual_Tnm,,,b509,0d4d00,value,,SIN,1000,,"Tnm used for calculation (set in DynamicTnm), valid after 1. Tapping"
16+
[id_sw>=114]r,,,KrmFaktorSmall,Krm_Faktor_Small,,,b509,0d4e00,value,,SIN,1000,,Krm Verstärkungsfaktor Small (1/1000)
17+
[id_sw>=114]r,,,KrmFaktorMiddl,Krm_Faktor_Middl,,,b509,0d4f00,value,,SIN,1000,,Krm Verstärkungsfaktor Middl (1/1000)
18+
[id_sw>=114]r,,,TnmFaktorSmall,Tnm_Faktor_Small,,,b509,0d5000,value,,SIN,1000,,Tnm Verstärkungsfaktor Small (1/1000)
19+
[id_sw>=114]r,,,TnmFaktorMiddl,Tnm_Faktor_Middl,,,b509,0d5100,value,,SIN,1000,,Tnm Verstärkungsfaktor Middl (1/1000)
2020
r,,,Ntc1Sensor,NTC 1 Sensor: T1 Temperature,,,b509,0d0000,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
2121
r,,,Ntc2Sensor,NTC 2 Sensor: T2 Temperature,,,b509,0d0100,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
2222
r,,,Ntc3Sensor,NTC 3 Sensor: T3 Temperature,,,b509,0d0200,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
@@ -34,24 +34,24 @@ r,,,AutoTappingTempDesired,Automatischer Zapfsollwert,,,b509,0d0c00,value,,D2C,,
3434
r,,,QuickVetoTempDesired,Quick Veto Sollwert,,,b509,0d0d00,value,,D2C,,°C,Temperatur
3535
r,,,ActualTappingTempDesired,Aktueller Zapfsollwert,,,b509,0d0e00,value,,D2C,,°C,Temperatur
3636
r,,,QuickVetoStart,Quick Veto start,,,b509,0d0f00,value,,UCH,0=off;1=on,,
37-
r,,,LegioStartDay,Starttag Legionellenschutz,,,b509,0d1000,value,,UCH,,0..8,0=Montag1 = Dienstag..6 = Sonntag7 = Legionellenschutz aus8 = täglich
37+
r,,,LegioStartDay,Starttag Legionellenschutz,,,b509,0d1000,value,,UCH,,,0=Montag1 = Dienstag..6 = Sonntag7 = Legionellenschutz aus8 = täglich
3838
r,,,LegioStartTime,Startzeit Legionellenschutz: Time when LegioProtect starts on specific day,,,b509,0d1100,value,,VTI,,,Uhrzeit
3939
r,,,PartyStart,Start Partyfunktion: Start Party Mode,,,b509,0d1200,value,,UCH,0=off;1=on,,
4040
r,,,HolidayStart,Start Ferienfunktion: Start Holiday Mode,,,b509,0d1300,value,,UCH,0=off;1=on,,
4141
r,,,ActorFernsteuerung,ActorFernsteuerung: TRUE -> RemoteControl of actors,,,b509,0d1b00,value,,UCH,0=off;1=on,,
4242
r,,,Time,Zeit: System Time,,,b509,0d2c00,value,,VTI,,,Uhrzeit
4343
r,,,Date,Datum: System Date,,,b509,0d2d00,value,,HDA:3,,,Datum
4444
r,,,Weekday,"Wochentag: System Weekday (0=Monday, 5=Saturday, 6=Sunday)",,,b509,0d2e00,value,,BDY,,,Wochentag
45-
r,,,TeleSwitch,TeleSWITCH,,,b509,0d3900,value,,UCH,,0..3,"TeleSwitch Operating Mode (0=disabled, 1=ON, 2=OFF, 3=AUTO"
45+
r,,,TeleSwitch,TeleSWITCH,,,b509,0d3900,value,,UCH,0=disabled;1=on;2=off;3=auto,,TeleSwitch Operating Mode
4646
r,,,TeleSwitchState,TeleSwitchState: Teleswitch port state (On / Off),,,b509,0d3a00,value,,UCH,0=off;1=on,,
4747
r,,,EnableHwcOperation,EnableDHWOperation: Enable DHW Ooperation,,,b509,0d4300,value,,UCH,0=off;1=on,,
48-
r,,,Krm,Krm,,,b509,0d1400,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
49-
r,,,Tm,Tm,,,b509,0d1500,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
50-
r,,,Tnm,Tnm,,,b509,0d1600,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
51-
r,,,Tvm,Tvm,,,b509,0d1700,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
52-
r,,,Krp,Krp,,,b509,0d1800,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
53-
r,,,Tvp,Tvp,,,b509,0d1900,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
54-
r,,,Tp,Tp,,,b509,0d1a00,value,,SIN,,in 1/1000,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
48+
r,,,Krm,Krm,,,b509,0d1400,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
49+
r,,,Tm,Tm,,,b509,0d1500,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
50+
r,,,Tnm,Tnm,,,b509,0d1600,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
51+
r,,,Tvm,Tvm,,,b509,0d1700,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
52+
r,,,Krp,Krp,,,b509,0d1800,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
53+
r,,,Tvp,Tvp,,,b509,0d1900,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
54+
r,,,Tp,Tp,,,b509,0d1a00,value,,SIN,1000,,"enter value in 1/1000: 25=0.025, 250=0,25, 2500=2,5"
5555
r,,,StateMainControl,State_MainControl: Aktuelle Zustandsnummer MainControl,,,b509,0d2f00,value,,UCH,,,
5656
r,,,StateMixerPumpControl,State_MixerPumpControl: Aktuelle Zustandsnummer MixerPumpControl,,,b509,0d3000,value,,UCH,,,
5757
r,,,StateCircoKick,State_CircoKick: Aktuelle Zustandsnummer CircoKickControl,,,b509,0d3100,value,,UCH,,,
@@ -68,7 +68,7 @@ w,,service,StInstallationDate,Installationsdatum: Installation Date,,,b509,0e410
6868
r,,,SteBusCheckFailedCounter,SteBusCheckFailedCounter: eBus Failed Counter,,,b509,0d4200,value,,UIN,,,
6969
w,,service,SteBusCheckFailedCounter,SteBusCheckFailedCounter: eBus Failed Counter,,,b509,0e4200,value,,UIN,,,
7070
r,,,DateTime,Datum Uhrzeit,,,b504,00,dcfstate,,UCH,0=nosignal;1=ok;2=sync;3=valid,,DCF Empfängerstatus,btime,,BTI,,,Uhrzeit,bdate,,BDA,,,Datum,temp,,D2B,,°C,Temperatur
71-
r,,,Mode,Betriebsmodus,,,b504,01,temp,,UCH,,°C,Temperatur,hwcmode,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus,ign,,IGN:2,,,,hwcmode_1,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus,mctype,,BI0:7,0=inactive;1=mixer;2=fixed;3=hwc;4=returnincr;5=pool;6=circulation,,Mischer Typ,hex,,HEX,,,,daynight,,UCH,0=night;1=day;7=floorpaving,,Tag-/Nachtmodus
71+
r,,,Mode,Betriebsmodus,,,b504,01,temp,,UCH,,°C,Temperatur,hwcmode,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus,ign,,IGN:2,,,,hwcmode_1,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus,mctype,,BI0:7,0=inactive;1=mixer;2=fixed;3=hwc;4=returnincr;5=pool;6=circulation,,Mischer Typ,hex,,HEX,,,,daynight,,UCH,0=night;1=day;4=load;7=floorpaving,,Tag-/Nachtmodus
7272
w,,,SetTempDesired,Solltemperatur setzen,,,b505,01,value,,UCH,,°C,Temperatur
7373
w,,,SetMode,Betriebsart setzen,,,b505,02,value,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus
7474
w,,,SetFlowTempMin,Minimalen Vorlaufsollwert setzen,,,b505,0e,value,,UCH,,°C,Temperatur