{"Building_1":{"File_Name":"Building_1.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":120,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
},
"Building_2":{"File_Name":"Building_2.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.21, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.92},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
},
"Building_3":{"File_Name":"Building_3.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.23, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":0.0, "efficiency":0.87},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":0.0001, "loss_coefficient":0.008}
},
"Building_4":{"File_Name":"Building_4.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":40,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":0.0, "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":0.0001, "loss_coefficient":0.008}
},
"Building_5":{"File_Name":"Building_5.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":25,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.24, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
},
"Building_6":{"File_Name":"Building_6.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":20,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.20, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.85},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
},
"Building_7":{"File_Name":"Building_7.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
},
"Building_8":{"File_Name":"Building_8.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.24, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.93},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
},
"Building_9":{"File_Name":"Building_9.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":"autosize", "loss_coefficient":0.006},
"DHW_Tank":{"capacity":"autosize", "loss_coefficient":0.008}
}
}