Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathLibvirt-command-for-virtio-scsi.txt
241 lines (229 loc) · 9.63 KB
/
Libvirt-command-for-virtio-scsi.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
1.Attach a scsi-block/scsi-hd/scsi-cd/scsi-generic device.
1.1.scsi-block device.
e.g1:...-drive file=/dev/disk/by-path/ip-10.66.33.253:3260-iscsi-iqn.2014.sluo.com:iscsi.storage.1-lun-1,if=none,id=drive-scsi0-0-0-1,format=raw,cache=none -device scsi-block,bus=scsi0.0,channel=0,scsi-id=0,lun=1,drive=drive-scsi0-0-0-1,id=scsi0-0-0-1
...
<disk type='block' device='lun' >
<driver name='qemu' type='raw' cache='none'/>
<source dev='/dev/disk/by-path/ip-10.66.33.253:3260-iscsi-iqn.2014.sluo.com:iscsi.storage.1-lun-1'/>
<target dev='sdb' bus='scsi'/>
<alias name='scsi0-0-0-1'/>
<address type='drive' controller='0' bus='0' target='0' unit='1'/>
</disk>
<controller type='scsi' index='0' model='virtio-scsi'>
<alias name='scsi0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
</controller>
...
1.2.scsi-hd device.
e.g2:...-device virtio-scsi-pci,id=scsi0,bus=pci.0,addr=0x7 -drive file=/home/my-data-disk.raw,if=none,id=drive-scsi0-0-0-1,format=raw,cache=none -device scsi-hd,bus=scsi0.0,channel=0,scsi-id=0,lun=1,drive=drive-scsi0-0-0-1,id=scsi0-0-0-1
...
<disk type='file' device='disk' >
<driver name='qemu' type='raw' cache='none'/>
<source file='/home/my-data-disk.raw'/>
<target dev='sdb' bus='scsi'/>
<alias name='scsi0-0-0-1'/>
<address type='drive' controller='0' bus='0' target='0' unit='1'/>
</disk>
<controller type='scsi' index='0' model='virtio-scsi'>
<alias name='scsi0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
</controller>
...
1.3.scsi-cd device.
e.g3:...-device virtio-scsi-pci,id=scsi0,bus=pci.0,addr=0x7 -drive file=/home/RHEL-7.0-20131030.1-Server-x86_64-dvd1.iso,if=none,id=drive-scsi0-0-0-1,readonly=on,format=raw,cache=none -device scsi-cd,bus=scsi0.0,channel=0,scsi-id=0,lun=1,drive=drive-scsi0-0-0-1,id=scsi0-0-0-1
...
<disk type='file' device='cdrom' >
<driver name='qemu' type='raw' cache='none'/>
<source file='/home/RHEL-7.0-20131030.1-Server-x86_64-dvd1.iso'/>
<target dev='hdb' bus='scsi'/>
<alias name='scsi0-0-0-1'/>
<address type='drive' controller='0' bus='0' target='0' unit='1'/>
</disk>
<controller type='scsi' index='0' model='virtio-scsi'>
<alias name='scsi0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
</controller>
...
1.4.scsi-generic device.
# sg_map | grep /dev/sdb
/dev/sg3 /dev/sdb
# virsh nodedev-list --tree
...
+- scsi_host6
|
+- scsi_target6_0_0
|
+- scsi_6_0_0_0
| |
| +- scsi_generic_sg2
|
+- scsi_6_0_0_1
|
+- block_sdb_1IET_00060001
+- scsi_generic_sg3
...
e.g4:...-drive file=/dev/sg3,if=none,id=drive-hostdev0,readonly=on -device scsi-generic,bus=scsi0.0,channel=0,scsi-id=0,lun=0,drive=drive-hostdev0,id=hostdev0
...
</controller>
<hostdev mode='subsystem' type='scsi'>
<source>
<adapter name='scsi_host6'/>
<address type='scsi' bus='0' target='0' unit='1'/>
</source>
<readonly/>
<address type='drive' controller='0' bus='0' target='0' unit='0'/>
</hostdev>
<controller type='scsi' index='0' model='virtio-scsi'>
<alias name='scsi0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
</controller>
...
2.Attach a virtio-blk device.
e.g:...-drive file=/home/my-data-disk.raw,if=none,id=drive-virtio-disk0,format=raw -device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,id=virtio-disk0
...
<disk type='file' device='disk'>
<driver name='qemu' type='raw'/>
<source file='/home/my-data-disk.raw'/>
<target dev='vda' bus='virtio'/>
<alias name='virtio-disk0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x05' function='0x0'/>
</disk>
...
3.Attach a ide-cd/ide-hd device.
3.1.ide-hd device.
e.g1:...-drive file=/home/my-data-disk.raw,if=none,id=drive-ide0-0-1,format=raw,cache=none -device ide-hd,bus=ide.0,unit=1,drive=drive-ide0-0-1,id=ide0-0-1
...
<disk type='file' device='disk'>
<driver name='qemu' type='raw' cache='none'/>
<source file='/home/my-data-disk.raw'/>
<target dev='hdb' bus='ide'/>
<address type='drive' controller='0' bus='0' target='0' unit='1'/>
</disk>
<controller type='ide' index='1'>
<alias name='ide1'/>
</controller>
...
3.2.ide-cd device.
e.g2:...-drive file=/home/RHEL-7.0-20140507.0-Server-x86_64-dvd1.iso,if=none,id=drive-ide0-0-1,readonly=on,format=raw,cache=none -device ide-cd,bus=ide.0,unit=1,drive=drive-ide0-0-1,id=ide0-0-1
...
<disk type='file' device='cdrom'>
<driver name='qemu' type='raw' cache='none'/>
<source file='/home/RHEL-7.0-20140507.0-Server-x86_64-dvd1.iso'/>
<target dev='hdb' bus='ide'/>
<address type='drive' controller='0' bus='0' target='0' unit='1'/>
</disk>
<controller type='ide' index='1'>
<alias name='ide1'/>
</controller>
...
4.Attach a ahci-cd/ahci-hd device.
4.1.ahci-hd device.
e.g1:...-device ahci,id=ahci0,bus=pci.0,addr=0x5 -drive file=/home/my-data-disk.raw,if=none,id=drive-sata0-0-0,format=raw -device ide-hd,bus=ahci0.0,drive=drive-sata0-0-0,id=sata0-0-0
...
<disk type='file' device='disk'>
<driver name='qemu' type='raw'/>
<source file='/home/my-data-disk.raw'/>
<target dev='sdb' bus='sata'/>
<alias name='ahci-disk0'/>
<address type='drive' controller='0' bus='0' target='0' unit='0'/>
</disk>
<controller type='sata' index='0'>
<alias name='sata0'/>
</controller>
...
4.2.ahci-cd device.
e.g2:...-device ahci,id=ahci0,bus=pci.0,addr=0x5 -drive file=/home/RHEL-7.0-20140507.0-Server-x86_64-dvd1.iso,if=none,media=cdrom,id=drive-sata0-0-0,readonly=on,format=raw -device ide-cd,bus=ahci0.0,drive=drive-sata0-0-0,id=sata0-0-0
...
<disk type='file' device='cdrom'>
<driver name='qemu' type='raw'/>
<source file='/home/RHEL-7.0-20140507.0-Server-x86_64-dvd1.iso'/>
<target dev='sdb' bus='sata'/>
<alias name='ahci-disk0'/>
<address type='drive' controller='0' bus='0' target='0' unit='0'/>
</disk>
<controller type='sata' index='0'>
<alias name='sata0'/>
</controller>
...
5.Attach/Detach a raw format disk device from XML file to guest.
5.1.start a domain.
# virsh create scsi-block-testing.xml
Domain scsi-block-testing created from scsi-block-testing.xml
5.2.create a disk desription file as following XML.
# cat disk-scsi-block.xml
<disk type='block' device='lun' >
<driver name='qemu' type='raw' cache='none'/>
<source dev='/dev/disk/by-path/ip-10.66.33.253:3260-iscsi-iqn.2014.sluo.com:iscsi.storage.1-lun-1'/>
<target dev='sdb' bus='scsi'/>
<alias name='scsi0-0-0-1'/>
<address type='drive' controller='0' bus='0' target='0' unit='1'/>
</disk>
5.3.# virsh attach-device scsi-block-testing disk-scsi-block.xml
Device attached successfully
5.4.# # virsh detach-disk scsi-block-testing sdb
Disk detached successfully
6.Attach/Detach a raw format disk device to guest
6.1.start a domain.
# virsh create scsi-block-testing.xml
Domain scsi-block-testing created from scsi-block-testing.xml
6.2.# virsh attach-disk scsi-block-testing /dev/disk/by-path/ip-10.66.33.253:3260-iscsi-iqn.2014.sluo.com:iscsi.storage.1-lun-1 sdb --type lun
Disk attached successfully
6.3.# virsh detach-disk scsi-block-testing sdb
Disk detached successfully
7.Migration with VM via virsh.
# virsh migrate --live $domain_name qemu+ssh://$dst_ip/system --verbose
migrate-setmaxdowntime set maximum tolerable downtime
migrate-compcache get/set compression cache size
migrate-setspeed Set the maximum migration bandwidth
migrate-getspeed Get the maximum migration bandwidth
8.Network device(rtl8139/e1000/virtio-net-pci).
e.g1:...-netdev tap,fd=23,id=hostnet0 -device virtio-net-pci,netdev=hostnet0,id=net0,mac=0a:01:38:b6:40:24,bus=pci.0,addr=0x3
...
<interface type='network'>
<mac address='0a:01:38:b6:40:24'/>
<source network='default'/>
<target dev='vnet0'/>
<model type='virtio-net-pci'/>
<alias name='net0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/>
</interface>
...
9.USB device.
# lsusb | grep CompUSA
Bus 002 Device 003: ID 1516:6221 CompUSA
# virsh attach-device $domain_name usb-disk.xml
e.g:...-device piix3-usb-uhci,id=usb,bus=pci.0,addr=0x1.0x2 -device usb-host,hostbus=2,hostaddr=3,id=hostdev0
...
<hostdev mode='subsystem' type='usb' managed='yes'>
<source>
<vendor id='0x1516'/>
<product id='0x6221'/>
<address bus='2' device='3'/>
</source>
</hostdev>
...
<controller type='usb' index='0' model='piix3-uhci'>
<alias name='usb0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x01' function='0x2'/>
</controller>
<controller type='usb' index='1' model='ich9-uhci1'>
<alias name='usb1'/>
<master startport='0'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/>
</controller>
<controller type='usb' index='1' model='ich9-uhci2'>
<alias name='usb2'/>
<master startport='2'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x07' function='0x0'/>
</controller>
<controller type='usb' index='1' model='ich9-uhci3'>
<alias name='usb3'/>
<master startport='4'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x08' function='0x0'/>
</controller>
...
<controller type='usb' index='1' model='ich9-ehci1'>
<alias name='usb4'/>
<address type='pci' domain='0x0000' bus='0x00' slot='0x09' function='0x0'/>
</controller>
...