Support ThreeWindingTransformer outages in NetworkModification #287

Description

@jd-lara

Context

PR #286 unified contingency handling around NetworkModification. Three-winding transformer outages are currently only supported via the internal ThreeWindingTransformerWinding type (individual winding arcs). Passing a full PSY.ThreeWindingTransformer component to the outage classification will error.

Current behavior

  • ThreeWindingTransformerWinding arcs are correctly classified via _resolve_branch_arc and handled in _compute_arc_ybus_delta.
  • A raw PSY.ThreeWindingTransformer passed as an outage component raises an error with a message directing users to use individual windings.

Desired behavior

  • Accept PSY.ThreeWindingTransformer directly in NetworkModification constructors and automatically decompose it into its three winding arcs.
  • Handle partial 3W transformer outages (single winding trip).