Variable flow rate for AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass
#10921
Labels
NewFeatureRequest
This "issue" is a new feature request, not a defect report
Triage
Issue needs to be assessed and labeled, further information on reported might be needed
General Summary
This request adds on to the list of requested improvements provided in #8122. The
AirLoopHVAC:UnitaryHeatCool:VAVChangeoverBypass
can only run at a constant flow rate. Commercially available systems can run at variable flow rates (down to a specific turndown ratio).Detailed Description
I tried using an EMS to control the fan flow rate of the existing unitary system, it worked, but the bypassed flow rate was not updated based on that new flow. As an alternative, I setup a model with a "dummy" zone (adiabatic envelope, no internal gains, and no OA requirements) served with a VAV (no reheat) terminal and controlled its minimum air flow fraction using a schedule and an EMS. It worked reasonably well, although I did notice a bit of discrepancy between the dummy zone temperature and the system supply air temperature.
Here's a publication on these systems:
https://www.trane.com/commercial/north-america/us/en/about-us/newsroom/blogs/the-evolution-of-changeover-systems.html
Possible Implementation
No response