I found an error in the NSSL-MP module (which I develop) for the 3-moment option and have some other minor updates to contribute. I assume this github is the place to submit a PR?

3-moment issue: The driver subroutine was not converting the units of the reflectivity moments back and forth between m^6/kg and m^6/m^3. This results in advection errors and incorrect units in the output. A main effect seems to be inflated reflectivity values (up to 3-5 dBZ).