AD SWIO Click

AD SWIO Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.


Click Library

  • Author : MikroE Team
  • Date : jun 2020.
  • Type : SPI type

Software Support

Example Description

This Click provides a fully integrated single chip solution for input and output operation. The AD-SWIO Click contains four 13-bit DACs, one per chanal, and 16-bit Σ-∆ ADC. These options give a lot of flexibility in choosing functionality for analog output, analog input, digital input, resistance temperature detector (RTD), and thermocouple measurements integrated into a single chip solution with a serial peripheral interface (SPI)

Example Libraries

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.AdSwio

Example Key Functions

  • adswio_cfg_setup Config Object Initialization function.
void adswio_cfg_setup ( adswio_cfg_t *cfg );
  • adswio_init Initialization function.
err_t adswio_init ( adswio_t *ctx, adswio_cfg_t *cfg );
  • adswio_default_cfg Click Default Configuration function.
void adswio_default_cfg ( adswio_t *ctx );
  • adswio_status_pin_ready This function checks the status of the ready pin.
uint8_t adswio_status_pin_ready ( adswio_t *ctx );
  • adswio_get_conv_results This function allows user to get the converted results of the selected channel.
adswio_err_t adswio_get_conv_results ( adswio_t *ctx, uint8_t channel, uint16_t *data_out );

Application Init

Performs a hardware reset of the Click board and executes a default configuration that enables channel A and sets it to measure voltage input in the range from 0V to 10V, with 4800 SPS.

void application_init ( void )
{
    log_cfg_t log_cfg;
    adswio_cfg_t cfg;

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );

    //  Click initialization.

    adswio_cfg_setup( &cfg );
    ADSWIO_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    adswio_init( &adswio, &cfg );
    Delay_ms ( 100 );

    adswio_default_cfg( &adswio );
    Delay_ms ( 1000 );

    adswio_rdy  = DUMMY;
    adswio_ch_a = DUMMY;
    adswio_res  = DUMMY;
    adswio_err  = ADSWIO_ERR_STATUS_OK;

    log_printf( &logger, " AD-SWIO Click initialization done \r\n");
    log_printf( &logger, "************************************\r\n");
}

Application Task

Waits for the data ready and then reads the results of ADC conversion from channel A and if response is ok, then prints the results on the uart console.

void application_task ( void )
{
    uint16_t timeout = 0;
    do
    {
        Delay_1ms( );
        timeout++;
        adswio_rdy = adswio_status_pin_ready( &adswio );
        if ( timeout > 3000 ) 
        {
            timeout = 0;
            log_printf( &logger, " Reinitializing...");
            adswio_default_cfg( &adswio );
            log_printf( &logger, "Done\r\n");
        }
    }
    while ( adswio_rdy != 0 );

    adswio_err = adswio_get_conv_results( &adswio, ADSWIO_SETUP_CONV_EN_CHA, &adswio_ch_a );

    if ( adswio_err == ADSWIO_ERR_STATUS_OK )
    {
        adswio_res = adswio_ch_a;
        adswio_res /= ADSWIO_RANGE_RESOLUTION;
        adswio_res *= ADSWIO_RANGE_VOLT_MV;
        adswio_ch_a = adswio_res;

        log_printf( &logger, " Voltage from channel A: %d mV\r\n", adswio_ch_a );
        
        log_printf( &logger, "-----------------------------------\r\n\r\n" );
        Delay_ms ( 200 );
    }
}

Application Output

This Click board can be interfaced and monitored in two ways:

  • Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
  • UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.

Additional Notes and Information

The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.