Sensor Class for TI TMP102 Temperature Sensor

1 Scope

This document defines the ECMAScript class supporting the TMP102 temperature sensor from Texas Instruments.

2 Conformance

This class specification conforms to the Temperature Sensor Class of ECMA-419, ECMAScript® Embedded Systems API Specification.

3 Normative References

4 Notational Conventions

5 TMP102 Sensor Class

Module Specifier: embedded:sensor/temperature/TMP102

The TMP102 Sensor Class extends the Temperature Sensor Class with additional properties on the option objects passed to the constructor and configure method and returned by the sample method.

Properties of constructor Options Object

Property Description
sensor An I2C class constructor options object with the I2C configuration to use for communication with the TMP102. This property is required. Its hz property defaults to 3_400_000 and its address property to 0x48.
alert A Digital class constructor options object with the configuration of the TMP102 alert pin. This property is required for instances that use the onAlert callback.
onAlert Callback that will be invoked when the alert pin is asserted. This property is required if alert is provided.

Properties of configure Options Object

All of the following properties are optional.

Most property names were chosen to reference the configuration options described in sections 7.5.3 and 7.5.4 of the data sheet.

Property Description
highTemperature Number specifying the temperature above which an alert will be asserted. Range is -40 to 125 degrees Celsius. Initial value is 80 degrees Celsius.
lowTemperature Number specifying the temperature below which an alert pin will be asserted. Range is -40 to 125 degrees Celsius. Initial value is 75 degrees Celsius.
polarity Number specifying the value to write to the alert pin when in an alert condition. Must be 0 or 1. Initial value is 0.
shutdownMode Boolean specifying if the module should turn off between requested sample operations. Initial value is false.
thermostatMode String specifying the thermostat operating mode. Must be either "comparator" or "interrupt". Initial value is "comparator".
faultQueue Number specifying the number of consecutive readings exceeding the limits of highTemperature or lowTemperature required to trigger an alert. Must be one of 1, 2, 4, or 6. Initial value is 1.
conversionRate Number specifying the TMP102 conversion rate in Hz. Must be one of 0.25, 1, 4, or 8. Initial value is 4.

Properties of Sample Object

TMP102 implements the sample object specified in the Temperature Sensor Class and extends it to include the following properties.

Property Description
alert Boolean indicating if a high temperature or low temperature alert has been asserted in the Configuration Register.

Inherited Property from Temperature

Property Description
temperature A number that represents the sampled temperature in degrees Celsius.